Plan Review Details - Permit 18080716
| Plan Review Stops For Permit 18080716 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-10-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-10-11 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-10-11 |
Time |
11:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-10-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-10-04 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-10-04 |
Time |
16:02 |
Sent To |
I |
|
| Notes |
| 2018-10-04 16:34:24 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. WIND LOAD CALCULATIONS REQUIRE SIGNATURE AND SEAL OF | | | DESIGNER. | | | PLANS THAT HAVE BEEN PREPARED BY AN ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD SHALL BEAR THE SIGNATURE, | | | DATE AND SEAL OF THE ENGINEER PER FL ADMIN. CODE RULE | | | 61G15-23.001. | | | | | | 2. SUBMITTAL DOCUMENTS SHALL BE IN DUPLICATE. | | | FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF | | | CONSTRUCTION DOCUMENTS, STATEMENT OF SPECIAL | | | INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL | | | BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT | | | APPLICATION. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED AND MARK VOID. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-08-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-08-27 |
Time |
08:11 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-08-27 |
Time |
07:32 |
Sent To |
I |
|
| Notes |
| 2018-08-27 08:13:10 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE DESIGN WIND LOADS FOR PROPOSED SIGN. | | | | | | FBC 107.3.5.1.1(8) ? PROVIDE WIND DESIGN LOADS/DESIGN | | | PRESSURES PURSUANT TO FBC-CHAPTER 16 | | | | | | 1603.1.4 WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | | STRUCTURE: | | | 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | | MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED, | | | VASD, AS DETERMINED IN ACCORDANCE WITH SECTION | | | 1609.3.1. | | | 2. RISK CATEGORY. | | | 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | | THAN ONE WIND EXPOSURE IS UTILIZED. | | | 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | | 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | | COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY | | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL | | | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/ | | | M2). | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED AND MARK VOID | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-10-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-10-04 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-09-27 |
Time |
15:17 |
Sent To |
|
|
| Notes |
| 2018-09-28 15:18:12 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-08-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-08-27 |
Time |
08:11 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-08-14 |
Time |
13:46 |
Sent To |
|
|
| Notes |
| 2018-08-15 13:46:23 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-10-03 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-10-03 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-10-03 |
Time |
11:21 |
Sent To |
B |
|
| Notes |
| 2018-10-03 11:22:11 | SIGN SHALL BE SERTBACK FROM PROPERTY LINE 5'. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-08-22 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-08-22 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-08-22 |
Time |
14:48 |
Sent To |
B |
|
| Notes |
| 2018-08-22 14:59:29 | ZONING REVIEW FAILED, DUE TO THE FOLLOWING: | | | | | | 1) PROVIDE A SURVEY/SITE PLAN DEPICTING THE FOLLOWING | | | INFORMATION: | | | PURSUANT TO SEC. 94-408(A)(2)B-E | | | B. MAXIMUM SUM TOTAL AREA OF ALL LOW FREESTANDING SIGNS | | | ON FRONT STREET: ONE SQUARE FOOT FOR EACH ONE LINEAR | | | FOOT OF FRONT STREET FRONTAGE OF THE LOTS ON WHICH | | | LOCATED. | | | C. MAXIMUM SUM TOTAL AREA OF ALL LOW FREESTANDING SIGNS | | | ON SIDE STREET FRONTAGE: 0.50 SQUARE FEET FOR EACH ONE | | | LINEAR FOOT OF FRONT STREET FRONTAGE OF THE LOTS ON | | | WHICH LOCATED. | | | D. MAXIMUM NUMBER OF ALL LOW FREESTANDING SIGNS ON EACH | | | LOT: ONE SIGN FOR EACH INDIVIDUAL BUSINESS OCCUPANT ON | | | THE LOT TO A MAXIMUM OF THREE SIGNS. | | | E. MINIMUM SETBACKS: | | | 1. FROM LOT LINE OF ANOTHER LOT: 24 FEET. | | | 2. FROM PUBLIC RIGHT-OF-WAY LINE: FIVE FEET. | | | 3. FROM INTERSECTIONS OF STREETS WITH OTHER STREETS AND | | | WITH ACCESS DRIVES: AS REQUIRED BY SUBSECTION | | | 94-305(E). | | | 4. MAXIMUM HEIGHT: TEN FEET. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ | | | ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: 561-822-1442 | | | E-MAIL: [email protected] |
|
|
|