Plan Review Details - Permit 18080664
| Plan Review Stops For Permit 18080664 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-09-21 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-09-21 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-09-20 |
Time |
08:54 |
Sent To |
|
|
| Notes |
| 2018-09-21 08:26:59 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 18080664 | | | REVIEWED: SEPTEMBER 21, 2018 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER I | | | [email protected] | | | 561-805-6718 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC AMENDED = FLORIDA BUILDING CODE,6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC ENERGY = FBC ENERGY CONSERVATION | | | | | | PLEASE CO-ORDINATE ELEVATIONS BETWEEN ARCHITECTURAL AND | | | CIVIL. ORIGINAL CIVIL PLANS ARE IN NVGD29 AND SHOW THE | | | F.F.E. AT 18.00. THE REVISION HERE SHOWS THE F.F.E. AT | | | NAVD 18.00. THERE IS A 1.55 MOIFIER BETWEEN THE TWO. | | | ALSO, ORIGINAL CIVIL SUBMITTED WITH GUARDHOUSE PERMIT | | | 16110574 SHOWS F.F.E. AT 18.00 THEN STEP DOWN TO 17.50 | | | FOR SIDE WALK AND STREET LEVEL IS 17.00. IF YOU NOW | | | HAVE F.F.E INTERIOR AND EXTERIOS SIDEWALK AT 18.00 THE | | | STREET WOULD BE AT 17.50. PLEASE PROVIDE UPDATED CIVIL | | | TO ACCOUNT FOR ELEVATION CHANGES. | | | | | | I WILL SEND TWO CLIPS OF ORIGINAL CIVIL PLANS VIA | | | E-MAIL FROM 16110574 TO ERIKA OLIVO TO HELP CLARIFY. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-10-01 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-10-01 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-08-14 |
Time |
08:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2018-09-21 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-09-21 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-09-21 |
Time |
08:29 |
Sent To |
|
|
| Notes |
| 2018-09-21 08:32:19 | 1ST REVIEW OK. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-10-01 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2018-10-01 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2018-10-01 |
Time |
11:34 |
Sent To |
|
|
| Notes |
| 2018-10-01 11:36:22 | 1. THIS PERMIT IS APPROVED FOR THE STRUCTURE ONLY. | | | | | | 2. SEPARATE PERMIT(S) REQUIRED FOR LANDSCAPING AND | | | IRRIGATION. | | | | | | 3. SITE WORK SHALL BE COVERED UNDER SEPARATE CIVIL | | | PERMIT(S). PLEASE NOTE THAT THE PARKING SPACE/REJECTION | | | LANE SHOWN ON THIS PARTIAL SITE PLAN DOES NOT CONFORM | | | TO THE MINIMUM REQUIREMENTS - A MINIMUM OF 24 FEET | | | SHALL BE PROVIDED BEHIND THE PARKING SPACE TO ALLOW FOR | | | BACK OUT. |
|
|
|