| Plan Review Stops For Permit 18080655 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2019-04-03 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-04-03 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-04-03 |
Time |
14:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2019-03-29 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-03-29 |
Time |
17:07 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-03-29 |
Time |
16:56 |
Sent To |
|
|
| Notes |
| 2019-03-29 17:09:33 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | JOSEAN A. DUPREY E.I., BN, PX | | | BUILDING PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6716 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 5TH REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | | | | SEE PREVIOUS LIST. NO NEW DOCUMENTS WERE SUBMITTED FOR | | | THIS REVIEW. | | | | | | FBC 107. PLEASE PROVIDE MORE INFORMATION: | | | | | | 1. THE INFORMATION PROVIDED ON THE SCHEDULE FOR | | | INSTALLATION OF OPENING PROTECTIVE DEVICES, SHOWS THE | | | SHUTTERS IN A HORIZONTAL SPAN, THIS SHOULD BE IN A | | | VERTICAL AS PER THE IDENTIFIED DETAILS IN THE PRODUCT | | | APPROVAL. | | | | | | | | | 2. SEVERAL DOCUMENTS WERE SUBMITTED MULTIPLE TIMES. FOR | | | EXAMPLE; DESIGN PRESSURE PAGE WAS UPLOADED TWICE, FLOOR | | | PLAN TWICE, TWO DIFFERENT FILES FOR THE INSTALLATION | | | SCHEDULE. PLEASE REFER TO THE PROJECTDOX NAMING | | | CONVENTION OR, IN THE FUTURE, SUBMIT PAPER RATHER THAN | | | DIGITAL. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2019-02-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-02-26 |
Time |
06:48 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-02-26 |
Time |
06:48 |
Sent To |
|
|
| Notes |
| 2019-02-26 06:51:07 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | 561 805 6724 | | | [email protected] | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | SEE PREVIOUS LIST. NO NEW DOCUMENTS WERE SUBMITTED FOR | | | THIS REVIEW. | | | | | | FBC 107. PLEASE PROVIDE MORE INFORMATION: | | | | | | 1. THE INFORMATION PROVIDED ON THE SCHEDULE FOR | | | INSTALLATION OF OPENING PROTECTIVE DEVICES, SHOWS THE | | | SHUTTERS IN A HORIZONTAL SPAN, THIS SHOULD BE IN A | | | VERTICAL AS PER THE IDENTIFIED DETAILS IN THE PRODUCT | | | APPROVAL. | | | 2. USING THE ALTERNATE 8 ANCHORS NEEDS TO HAVE A | | | GREATER EDGE DISTANCE THAN USING THE TAPCONS. THERE MAY | | | NOT BE ENOUGH WOOD SUBSTRATE TO MEET THE EDGE DISTANCE | | | REQUIREMENTS, CONSIDERING THE WOOD FRAMED EXISTING | | | CONDITION. | | | | | | PLEASE REVIEW THE SUBMITTED INFORMATION AND RE-SUBMIT | | | CLARIFYING THE ORIENTATION AND ANCHORING OF THE PANELS | | | AT OPENING #1. | | | | | | NEW COMMENT: | | | | | | 2. SEVERAL DOCUMENTS WERE SUBMITTED MULTIPLE TIMES. FOR | | | EXAMPLE; DESIGN PRESSURE PAGE WAS UPLOADED TWICE, FLOOR | | | PLAN TWICE, TWO DIFFERENT FILES FOR THE INSTALLATION | | | SCHEDULE. PLEASE REFER TO THE PROJECTDOX NAMING | | | CONVENTION OR, IN THE FUTURE, SUBMIT PAPER RATHER THAN | | | DIGITAL. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2018-12-17 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2018-12-17 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2018-12-17 |
Time |
16:51 |
Sent To |
|
|
| Notes |
| 2018-12-17 17:03:47 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | FBC 107. PLEASE PROVIDE MORE INFORMATION: | | | | | | 1. THE INFORMATION PROVIDED ON THE SCHEDULE FOR | | | INSTALLATION OF OPENING PROTECTIVE DEVICES, SHOWS THE | | | SHUTTERS IN A HORIZONTAL SPAN, THIS SHOULD BE IN A | | | VERTICAL AS PER THE IDENTIFIED DETAILS IN THE PRODUCT | | | APPROVAL. | | | 2. USING THE ALTERNATE 8 ANCHORS NEEDS TO HAVE A | | | GREATER EDGE DISTANCE THAN USING THE TAPCONS. THERE MAY | | | NOT BE ENOUGH WOOD SUBSTRATE TO MEET THE EDGE DISTANCE | | | REQUIREMENTS, CONSIDERING THE WOOD FRAMED EXISTING | | | CONDITION. | | | | | | PLEASE REVIEW THE SUBMITTED INFORMATION AND RE-SUBMIT | | | CLARIFYING THE ORIENTATION AND ANCHORING OF THE PANELS | | | AT OPENING #1. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-10-19 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-10-19 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-10-19 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2018-10-19 16:54:33 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 18080655 | | | 2 ND REVIEW: OCTOBER 19, 2018 | | | | | | IS OPENING NUMBER 1 REALLY BEING INSTALLED | | | HORIZONTALLY? | | | THAT WOULD MEAN THAT THE PANEL IS 15' LONG. | | | THE PRODUCT APPROVAL DOESN'T ACCOMODATE PANELS THAT | | | SIZE. | | | | | | TO CLEAR THIS UP ARE YOUR PANELMATES BEING INSTALLED ON | | | THE SIDES, OR ON THE TOP AND BOTTOM OF OPENINGS? | | | THE SPAN IS EQUIVELANT TO THE LENTH OF PANEL. | | | | | | IF THE PANELS FOR OPENING 1 ARE INSTALLED WITH | | | PANELMATES TOP AND BOTTOM THAN THE PANELS ARE BEING | | | INSTALLED VERTICAL AND THE SPAN IS DISTANCE BETWEEN | | | ANCHORS. | | | SPECIFY THE ALTERNATIVE ANCHOR BEING USED FOR WOOD | | | CONNECTION. IF IT IS ALTERNATIVE 8 THAN SEE HOW TOP | | | REQUIRES MINIMUM 2" EDGE DISTANCE AND EQUAL SPACING ON | | | BOTTOM PLATE. | | | | | | PLEASE CALL IF ANY QUESTIONS BEFORE RE-SUBMITTING. | | | I WILL GO OVER THE DETAILS OF PRODUCT APPROVAL WITH YOU | | | BY PHONE, OR COME INTO BUILDING DEPARTMENT FOR CONSULT. | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER I | | | [email protected] | | | 561-805-6718 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-09-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-05 |
Time |
18:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-05 |
Time |
18:03 |
Sent To |
|
|
| Notes |
| 2018-09-05 18:07:58 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. REVISE PLAN TO SHOW MEANS OF ESCAPE REQUIRED BY FBC | | | R 310.4; INCLUDE ROOM DESIGNATION. | | | | | | 2. SEE THE INSTALLATION SCHEDULE; IT IS NOT CLEAR HOW | | | SPANS WERE DETERMINED. FOR INSTANCE, OPENING 1, W X H, | | | 183 X 57, SPAN IS 93 BUT SHOULD BE 185.5" (FOR | | | HORIZONTAL INSTALLATION, ANCHOR TO ANCHOR WHICH WOULD | | | BE WIDTH + EDGE DISTANCE ON EACH SIDE). | | | | | | SEE ALSO OPENING 5, 33 X 32, SPAN IS 31.5. | | | | | | THESE ARE TWO EXAMPLES BUT THERE ARE OTHER ERRORS, | | | PLEASE REVISE. | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-03-25 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-03-25 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-03-25 |
Time |
11:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-12-18 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-12-18 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-12-18 |
Time |
15:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-10-05 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-10-05 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-10-05 |
Time |
13:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2019-03-29 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-03-29 |
Time |
17:09 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-03-12 |
Time |
12:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-02-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-02-26 |
Time |
06:51 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-02-15 |
Time |
09:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-12-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-12-21 |
Time |
17:14 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-12-07 |
Time |
14:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-10-19 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-10-19 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-10-09 |
Time |
14:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-10-05 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-10-05 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-08-29 |
Time |
13:05 |
Sent To |
|
|
| Notes |
|
|