Plan Review Details - Permit 18080548
Plan Review Stops For Permit 18080548
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-12-19 Cont ID  
Sent By cthroop Date 2018-12-11 Time 16:40 Rev Time 0.00
Received By cthroop Date 2018-12-10 Time 13:44 Sent To  
Notes
2018-12-11 16:44:23NO NOTES
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-09-27 Cont ID  
Sent By cthroop Date 2018-09-27 Time 12:41 Rev Time 0.00
Received By cthroop Date 2018-09-27 Time 08:50 Sent To  
Notes
2018-09-27 12:59:29BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. SOILS REPORT -
 A. PROVIDE TWO COPIES OF ALL SUBMITTAL DOCUMENTS.
 B. ENGINEER'S SIGNATURE AND SEAL TO BE ORIGINAL.
 FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF
 CONSTRUCTION DOCUMENTS, STATEMENT OF SPECIAL
 INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL
 BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT
 APPLICATION.
 PLANS THAT HAVE BEEN PREPARED BY AN ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD SHALL BEAR THE SIGNATURE,
 DATE AND SEAL OF THE ENGINEER PER FL ADMIN. CODE RULE
 61G15-23.001.
  
 2. PROVIDE SITE DRAINAGE PLAN -
 FBC R401.3 SITE DRAINAGE
 PROVIDE TWO SETS OF A SITE DRAINAGE PLAN SHOWING
 COMPLIANCE WITH FBC R401.3 DRAINAGE.
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT
 DOES NOT CREATE A HAZARD.
 LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM
 FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6
 INCHES WITHIN THE FIRST 10 FEET.
 EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER
 PHYSICAL BARRIERS PROHIBIT 6 INCHES OF FALL WITHIN 10
 FEET, DRAINS OR SWALES SHALL BE CONSTRUCTED TO ENSURE
 DRAINAGE AWAY FROM THE STRUCTURE.
 IMPERVIOUS SURFACES WITHIN 10 FEET OF THE BUILDING
 FOUNDATION SHALL BE SLOPED A MINIMUM OF
 2 PERCENT AWAY FROM THE BUILDING.
 FBC R 401.3 (DRAINAGE)
 FBC 107.2.5 (SITE PLAN)
 FBC 110.9 (IMPACT OF CONSTRUCTION)
  
 3. ROOFING PERMIT IS REQUIRED -
 A. SUBMITTAL NOA 17-1120.01 IS DIFFERENT THAN THA NOA
 11-0307.04 LISTED ON PLAN. PLEASE CLARIFY.
 B. SUBMITTAL'S SHALL BE REVIEWED AND APPROVED INWRITING
 BY DESIGNER.
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING SUBMITTALS.
  
 4. PROVIDE PRODUCT APPROVALS FOR WINDOW MULLIONS.
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE WINDOW SUBMITTALS.
  
 5. PALM BEACH COUNTY IMPACT FEES MAY BE REQUIRED.
 PLEASE SEE COMMENTS UNDER IMPACT REVIEW.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED AND MARK VOID.
  
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE DOOR SUBMITTALS.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-11-13 Cont ID  
Sent By jpearson Date 2018-11-13 Time 15:19 Rev Time 0.00
Received By jpearson Date 2018-11-13 Time 12:33 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-09-05 Cont ID  
Sent By jpearson Date 2018-09-05 Time 14:33 Rev Time 0.00
Received By jpearson Date 2018-09-05 Time 14:33 Sent To  
Notes
2018-09-05 14:32:58CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. ARCHITECT SEAL IS ILLEGIBLE AND DOES NOT APPEAR TO
 COMPLY WITH THE REQUIREMENTS OF FLORIDA ADMINISTRATIVE
 CODE, FAC 61G1-16.002. PROVIDE CORRECTION.
 2. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF
 SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE,
 WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY
 SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW
 INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230,
 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1,
 E3609.3; WPB FBC 107.2.1
 3. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE
 EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE
 IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2
 4. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT,
 SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN
 KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS,
 PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS,
 RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND
 SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. PROVIDE
 CORRECTION. NEC 210.12; FBC RE E3902.16
 5. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE
 LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF
 THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE.
 FBC EC C405.1, R404.1
 6. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED
 PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING
 ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS
 NEW INSTALLATIONS. FBC RE R314.3, R315.1; WPB FBC
 107.2.1
 7. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A
 NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14
 8. PROVIDE GFCI PROTECTED OUTLET FOR SERVICING OF A/C
 EQUIPMENT WITHIN 25 FEET OF THE EQUIPMENT PER CODE. NEC
 210.63; FBC RE E3901.12
 9. NOTE 1 STATES THAT INSTALLATION SHALL COMPLY WITH
 NEC 2012, WHICH DOES'T EXIST. PROVIDE CORRECTION. FBC
 PREFACE (ALSO SEE CURRENT CODES ABOVE)
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD
 SHEETS?.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2018-11-13 Cont ID  
Sent By fmittner Date 2018-11-13 Time 15:51 Rev Time 0.00
Received By fmittner Date 2018-11-13 Time 15:51 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2018-08-21 Cont ID  
Sent By destabro Date 2018-08-21 Time 15:22 Rev Time 0.00
Received By destabro Date 2018-08-21 Time 15:22 Sent To Z
Notes
2018-08-21 15:23:368/21/2018 - MEETS CONDITIONS REQUIRED PER LEVEL 2
 REVIEW HPB CASE NO. 18-50. DLE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-12-18 Cont ID  
Sent By jesmith Date 2018-12-18 Time 15:00 Rev Time 0.00
Received By jesmith Date 2018-12-18 Time 15:00 Sent To  
Notes
2018-10-25 15:05:18R13

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-09-27 Cont ID  
Sent By hmoser Date 2018-09-27 Time 15:03 Rev Time 0.00
Received By hmoser Date 2018-08-10 Time 12:42 Sent To  
Notes
2018-08-14 12:42:17R31

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2019-01-02 Cont ID  
Sent By cthroop Date 2019-01-02 Time 12:41 Rev Time 0.00
Received By cthroop Date 2019-01-02 Time 12:41 Sent To  
Notes
2019-01-02 12:43:31IMPACT FEES $0, MU - 2018-042244-0000. CT

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2018-09-27 Cont ID  
Sent By cthroop Date 2018-09-27 Time 12:39 Rev Time 0.00
Received By cthroop Date 2018-09-27 Time 12:38 Sent To  
Notes
2018-09-27 12:41:13BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. COUNTY IMPACT FEES MAY BE REQUIRED.
  
 PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE
 PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE
 RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS
 APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2018-11-16 Cont ID  
Sent By cmontell Date 2018-11-16 Time 09:13 Rev Time 0.00
Received By cmontell Date 2018-11-16 Time 09:09 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2018-09-27 Cont ID  
Sent By hmoser Date 2018-09-27 Time 15:03 Rev Time 0.00
Received By hmoser Date 2018-09-27 Time 15:03 Sent To I
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-12-18 Cont ID  
Sent By jesmith Date 2018-12-18 Time 14:59 Rev Time 0.00
Received By jesmith Date 2018-12-18 Time 14:58 Sent To  
Notes
2018-12-18 14:59:20PLUMBING COMMEMTS: APPROVED
  
 PLUMBING PROVISO
 1. ALL WORK PER CITY CODES SUBJECT TO FIELD INSPECTOR'S
 APPROVAL
 2. HOT AND COLD WATER TO WASHER TO CONNECT TO EXISTING.
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-09-18 Cont ID  
Sent By shill Date 2018-09-18 Time 14:59 Rev Time 0.00
Received By jesmith Date 2018-09-18 Time 14:54 Sent To  
Notes
2018-09-18 14:59:331ST REVIEW: FBC 2017 6TH EDITION
 PERMIT 18080548
 PLUMBING COMMENTS: DENIED
  
 1. RE: PLAN SHEET ME.1
 A. PER FBC WPB AMEND 107.3.5.3 (12), PROVIDE SANITARY
 RISER DIAGRAM FOR 2" WASHER DRAIN PIPE SHOWING THE TRAP
 TO VENT IN ACCORDANCE WITH FBC RES P3105.1, VENT SIZED
 IN ACCCORDANCE WITH FBC RES P3113.1 TO THE OUTSIDE IN
 ACCORDANCE WITH FBC RES P3102.1 AND CONNECTION TO
 EXISTING SANITARY SEWER USING A COMPLIANT FITTING SUCH
 AS A WYE OR COMBINATION WYE AND 1/8 BEND IN ACCORDANCE
 WITH FBC PLUMBING TABLE 706.3 PER FBC RES P2601.1.
 B. PROVIDE NOTE "ACCESSIBLE SHUTOFF VALVES REQUIRED"
 PER FBC RES P2903.9.3.
 C. PROVIDE NOTE "PROVIDE WATER HAMMER ARRESTORS " PER
 FBC RES P2903.5.
 2. PLUMBING SCOPE ON PLAN CALLS ONLY TO FURNISH
 HOT,COLD WATER AND DRAIN FOR NEW WASHER. IF A NEW WATER
 HEATER IS REQUIRED TO ACCOMPLISH THE HOT WATER
 REQUIREMENTS IT WILL NEED TO BE ADDED TO THE PLANS ON
 THE RESUBMITTAL.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6715

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2018-12-19 Cont ID  
Sent By cthroop Date 2018-12-11 Time 15:37 Rev Time 0.00
Received By cthroop Date 2018-12-10 Time 13:44 Sent To  
Notes
2018-12-11 15:39:55NO NOTES
  
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2018-09-27 Cont ID  
Sent By cthroop Date 2018-09-27 Time 12:59 Rev Time 0.00
Received By cthroop Date 2018-09-27 Time 12:59 Sent To  
Notes
2018-09-27 13:01:39BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. ROOFING PERMIT REQUIRED.
 2. PROVIDE PRODUCT APPROVALS REVIEWED AND APPROVED IN
 WRITING BY DESIGNER.
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING SUBMITTALS.

Review Stop Z ZONING
Rev No 2 Status P Date 2018-11-13 Cont ID  
Sent By fmittner Date 2018-11-13 Time 15:51 Rev Time 0.00
Received By fmittner Date 2018-11-13 Time 15:51 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2018-08-21 Cont ID  
Sent By destabro Date 2018-08-21 Time 15:23 Rev Time 0.00
Received By destabro Date 2018-08-21 Time 15:23 Sent To I
Notes
2018-08-21 15:24:128/21/2018 - MEETS SETBACK AND ACCESSORY STRUCTURE
 SIZING REQUIREMENTS. DLE