| Plan Review Stops For Permit 18080548 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-12-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-12-11 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-12-10 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2018-12-11 16:44:23 | NO NOTES | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-09-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-09-27 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-09-27 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2018-09-27 12:59:29 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. SOILS REPORT - | | | A. PROVIDE TWO COPIES OF ALL SUBMITTAL DOCUMENTS. | | | B. ENGINEER'S SIGNATURE AND SEAL TO BE ORIGINAL. | | | FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF | | | CONSTRUCTION DOCUMENTS, STATEMENT OF SPECIAL | | | INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL | | | BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT | | | APPLICATION. | | | PLANS THAT HAVE BEEN PREPARED BY AN ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD SHALL BEAR THE SIGNATURE, | | | DATE AND SEAL OF THE ENGINEER PER FL ADMIN. CODE RULE | | | 61G15-23.001. | | | | | | 2. PROVIDE SITE DRAINAGE PLAN - | | | FBC R401.3 SITE DRAINAGE | | | PROVIDE TWO SETS OF A SITE DRAINAGE PLAN SHOWING | | | COMPLIANCE WITH FBC R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. | | | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM | | | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 | | | INCHES WITHIN THE FIRST 10 FEET. | | | EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER | | | PHYSICAL BARRIERS PROHIBIT 6 INCHES OF FALL WITHIN 10 | | | FEET, DRAINS OR SWALES SHALL BE CONSTRUCTED TO ENSURE | | | DRAINAGE AWAY FROM THE STRUCTURE. | | | IMPERVIOUS SURFACES WITHIN 10 FEET OF THE BUILDING | | | FOUNDATION SHALL BE SLOPED A MINIMUM OF | | | 2 PERCENT AWAY FROM THE BUILDING. | | | FBC R 401.3 (DRAINAGE) | | | FBC 107.2.5 (SITE PLAN) | | | FBC 110.9 (IMPACT OF CONSTRUCTION) | | | | | | 3. ROOFING PERMIT IS REQUIRED - | | | A. SUBMITTAL NOA 17-1120.01 IS DIFFERENT THAN THA NOA | | | 11-0307.04 LISTED ON PLAN. PLEASE CLARIFY. | | | B. SUBMITTAL'S SHALL BE REVIEWED AND APPROVED INWRITING | | | BY DESIGNER. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | 4. PROVIDE PRODUCT APPROVALS FOR WINDOW MULLIONS. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW SUBMITTALS. | | | | | | 5. PALM BEACH COUNTY IMPACT FEES MAY BE REQUIRED. | | | PLEASE SEE COMMENTS UNDER IMPACT REVIEW. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED AND MARK VOID. | | | | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE DOOR SUBMITTALS. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-11-13 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-11-13 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-11-13 |
Time |
12:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-09-05 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-09-05 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-09-05 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2018-09-05 14:32:58 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. ARCHITECT SEAL IS ILLEGIBLE AND DOES NOT APPEAR TO | | | COMPLY WITH THE REQUIREMENTS OF FLORIDA ADMINISTRATIVE | | | CODE, FAC 61G1-16.002. PROVIDE CORRECTION. | | | 2. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | | 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1, | | | E3609.3; WPB FBC 107.2.1 | | | 3. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | 4. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. PROVIDE | | | CORRECTION. NEC 210.12; FBC RE E3902.16 | | | 5. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | | FBC EC C405.1, R404.1 | | | 6. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING | | | ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS | | | NEW INSTALLATIONS. FBC RE R314.3, R315.1; WPB FBC | | | 107.2.1 | | | 7. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 | | | 8. PROVIDE GFCI PROTECTED OUTLET FOR SERVICING OF A/C | | | EQUIPMENT WITHIN 25 FEET OF THE EQUIPMENT PER CODE. NEC | | | 210.63; FBC RE E3901.12 | | | 9. NOTE 1 STATES THAT INSTALLATION SHALL COMPLY WITH | | | NEC 2012, WHICH DOES'T EXIST. PROVIDE CORRECTION. FBC | | | PREFACE (ALSO SEE CURRENT CODES ABOVE) | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD | | | SHEETS?. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-11-13 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-11-13 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-11-13 |
Time |
15:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-08-21 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2018-08-21 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2018-08-21 |
Time |
15:22 |
Sent To |
Z |
|
| Notes |
| 2018-08-21 15:23:36 | 8/21/2018 - MEETS CONDITIONS REQUIRED PER LEVEL 2 | | | REVIEW HPB CASE NO. 18-50. DLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-12-18 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2018-12-18 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-12-18 |
Time |
15:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-09-27 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-09-27 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-08-10 |
Time |
12:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2019-01-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-02 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-02 |
Time |
12:41 |
Sent To |
|
|
| Notes |
| 2019-01-02 12:43:31 | IMPACT FEES $0, MU - 2018-042244-0000. CT |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2018-09-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-09-27 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-09-27 |
Time |
12:38 |
Sent To |
|
|
| Notes |
| 2018-09-27 12:41:13 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. COUNTY IMPACT FEES MAY BE REQUIRED. | | | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-11-16 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-11-16 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-11-16 |
Time |
09:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2018-09-27 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-09-27 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-09-27 |
Time |
15:03 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-12-18 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2018-12-18 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-12-18 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2018-12-18 14:59:20 | PLUMBING COMMEMTS: APPROVED | | | | | | PLUMBING PROVISO | | | 1. ALL WORK PER CITY CODES SUBJECT TO FIELD INSPECTOR'S | | | APPROVAL | | | 2. HOT AND COLD WATER TO WASHER TO CONNECT TO EXISTING. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-09-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-18 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-09-18 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2018-09-18 14:59:33 | 1ST REVIEW: FBC 2017 6TH EDITION | | | PERMIT 18080548 | | | PLUMBING COMMENTS: DENIED | | | | | | 1. RE: PLAN SHEET ME.1 | | | A. PER FBC WPB AMEND 107.3.5.3 (12), PROVIDE SANITARY | | | RISER DIAGRAM FOR 2" WASHER DRAIN PIPE SHOWING THE TRAP | | | TO VENT IN ACCORDANCE WITH FBC RES P3105.1, VENT SIZED | | | IN ACCCORDANCE WITH FBC RES P3113.1 TO THE OUTSIDE IN | | | ACCORDANCE WITH FBC RES P3102.1 AND CONNECTION TO | | | EXISTING SANITARY SEWER USING A COMPLIANT FITTING SUCH | | | AS A WYE OR COMBINATION WYE AND 1/8 BEND IN ACCORDANCE | | | WITH FBC PLUMBING TABLE 706.3 PER FBC RES P2601.1. | | | B. PROVIDE NOTE "ACCESSIBLE SHUTOFF VALVES REQUIRED" | | | PER FBC RES P2903.9.3. | | | C. PROVIDE NOTE "PROVIDE WATER HAMMER ARRESTORS " PER | | | FBC RES P2903.5. | | | 2. PLUMBING SCOPE ON PLAN CALLS ONLY TO FURNISH | | | HOT,COLD WATER AND DRAIN FOR NEW WASHER. IF A NEW WATER | | | HEATER IS REQUIRED TO ACCOMPLISH THE HOT WATER | | | REQUIREMENTS IT WILL NEED TO BE ADDED TO THE PLANS ON | | | THE RESUBMITTAL. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6715 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2018-12-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-12-11 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-12-10 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2018-12-11 15:39:55 | NO NOTES | | | | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-09-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-09-27 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-09-27 |
Time |
12:59 |
Sent To |
|
|
| Notes |
| 2018-09-27 13:01:39 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. ROOFING PERMIT REQUIRED. | | | 2. PROVIDE PRODUCT APPROVALS REVIEWED AND APPROVED IN | | | WRITING BY DESIGNER. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-11-13 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-11-13 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-11-13 |
Time |
15:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-08-21 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2018-08-21 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2018-08-21 |
Time |
15:23 |
Sent To |
I |
|
| Notes |
| 2018-08-21 15:24:12 | 8/21/2018 - MEETS SETBACK AND ACCESSORY STRUCTURE | | | SIZING REQUIREMENTS. DLE |
|
|