Plan Review Details - Permit 18080490
| Plan Review Stops For Permit 18080490 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-08-25 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2018-08-25 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
|
Time |
|
Sent To |
FIRE |
|
| Notes |
| 2018-08-25 09:02:48 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC (ACCESSIBILITY) 404.2/TABLE 404.2.4.1. AS PER | | | THE INFORMATION PROVIDED IT APPEARS THAT THE NEW 13' | | | LONG WALL WILL CONFLICT WITH THE REAR DOOR REQUIREMENTS | | | (12 " OF SPACE PARALLEL TO DOORWAY BEYOND THE LATCH | | | SIDE). | | | | | | 2. FBC 1016.2 LABEL EACH AREA FOR ROOM DESIGNATION, | | | OCCUPANT LOAD, AND OCCUPANCY CLASSIFICATION. | | | | | | 3. FBC 107. PLEASE PROVIDE AN ELECTRIC SUB PERMIT FOR | | | THE ELECTRIC WORK OF NEW WALLS. | | | | | | NOTE: AT TIME OF INSPECTION THE FIELD INSPECTOR WILL | | | NEED ACCESS TO ALL AREAS OF BUILDING CONNECTIONS FOR | | | VERIFICATION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-08-18 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2018-08-18 |
Time |
15:22 |
Rev Time |
|
| Received By |
pvalenti |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
| 2018-08-18 15:30:02 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC 107. PLEASE PROVIDE A COMPLETE FLOOR PLAN OF | | | BUILDING SPECIFICALLY SHOWING INTERIOR DIMENSIONS, EXIT | | | DOORS, PATHS OF EGRESS, & EXIT SIGN LOCATIONS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-08-30 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-08-30 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-08-30 |
Time |
12:02 |
Sent To |
|
|
| Notes |
| 2018-08-30 12:03:53 | NEW ROOM REQUIRES A LIGHT AND SWITCH JLEAHY 210.70 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2018-08-28 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-08-28 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-08-28 |
Time |
09:58 |
Sent To |
E |
|
| Notes |
| 2018-08-28 10:02:46 | PERMIT #18080490 | | | FIRE REVIEW COMMENTS | | | | | | 1) PLEASE REVIEW AND RESPOND TO ALL PLAN REVIEW | | | COMMENTS. (SEE BLDG REVIEW.) | | | 2) DRAWINGS WILL BE STAMPED, INITIALED, AND DATED BY | | | THE FIRE DEPARTMENT AFTER ALL PLAN REVIEWER COMMENTS | | | HAVE BEEN SATISFIED. | | | | | | SUE ELLEN CALDERON | | | ASST. FIRE MARSHAL | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-08-27 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2018-08-25 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2018-08-23 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2018-08-24 13:51:03 | RESUB ROUTED TO PVALENTI |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-08-18 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2018-08-18 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2018-08-10 |
Time |
12:39 |
Sent To |
I |
|
| Notes |
| 2018-08-14 12:40:05 | BLDG <5K |
|
|
|