| Plan Review Stops For Permit 18080398 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-12-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-12-21 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-12-21 |
Time |
07:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-09-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-09-18 |
Time |
19:40 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-09-18 |
Time |
10:42 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-12-13 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-12-13 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-12-13 |
Time |
07:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-08-30 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-08-30 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-08-30 |
Time |
09:00 |
Sent To |
|
|
| Notes |
| 2018-08-30 12:59:01 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. LOAD CALCULATION IS NOT ACCURATE. PROVIDE ACCURATE | | | LOAD CALCULATION INCLUDING ALL LOADS. NEC 220; FBC RE | | | E3602.2 | | | | | | 10KW @100%= 5000KW FOR A/C? | | | | | | APPLIANCE (NOT LABLED) 3000KW? | | | | | | 2. I AM NOT AWARE OF A COOKTOP UNIT THAT IS 20AMP @ | | | 1500WATTS. PLEASE PROVIDE UL OR OTHER NRTL LISTING AND | | | ADJUST LOAD CALC ACCORDINGLY. NEC 110.3B | | | | | | 3. JACUZZI TUB RECEPTACLE NEEDS GFCI PROTECTION. | | | 680.43A3 NEC | | | | | | 4. KITCHEN REQUIRES MINIMUM OF 2-20AMP SMALL APPLIANCE | | | CIRCUITS, ONLY ONE ON PLANS. PLEASE PROVIDE CORRECTION. | | | 210.52B1 NEC | | | | | | 5. SMOKE DETECTOR OUTSIDE OF BEDROOM MUST ALSO BE A | | | CARBON MONOXIDE DETECTOR. FBC R315.1 | | | | | | 6. NO LOCATION FOR SERVICE EQUIPMENT ON PLAN, PLEASE | | | PROVIDE CORRECTION. FBC 107.2.1 INFORMATIONAL NOTE: | | | SERVICE RECEPTACLE REQUIRED WITHIN 50' OF SERVICE. | | | 210.64 NEC | | | | | | 7. POWER UTILITY NORMALLY DOESNT INSTALL RIGID STEEL | | | CONDUIT TO METER, USUALLY IT IS PVC TYPE CONDUIT. | | | PLEASE CONFIRM WITH POWER UTILITY AND PROVIDE | | | CORRECTION. FBC 107.2.1 | | | | | | 8. DISHWASHER MUST BE ARC-FAULT AND GFCI PROTECTED | | | 210.8D, 210.12A NEC | | | | | | 9. PROVIDE ACCURATE PANEL SCHEDULE INDICATING ANY NEW | | | OR ALTERED CIRCUITS, THE WIRE AND BREAKER SIZE FOR | | | THESE CIRCUITS, AND AFCI OR GFCI PROTECTION WHERE | | | APPLICABLE TO COMPLY WITH CODE. NEC 210.8, 210.12, | | | 215.5, 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 | | | | | | 10. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE. | | | FBC EC R404.1 | | | | | | | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WPB | | | [email protected] | | | CELL: 561-657-1653 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2018-08-15 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-08-15 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-08-15 |
Time |
15:14 |
Sent To |
|
|
| Notes |
| 2018-08-15 15:15:01 | GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN | | | THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN | | | PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS | | | WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE | | | RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT | | | REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE. AT | | | THIS TIME. WPB AMENDMENTS TO FBC SEC. 107.2.1. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-01-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-08 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-08 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2019-01-08 14:44:45 | IMPACT FEES ROUTED TO CTHROOP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-12-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-12-21 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-11-28 |
Time |
15:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-09-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-09-18 |
Time |
19:41 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-08-08 |
Time |
15:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2019-01-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-08 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-08 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2019-01-08 15:15:31 | IMPACT FEES $0.00, MU-2019-411. CT |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2018-09-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-09-18 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-09-18 |
Time |
10:42 |
Sent To |
|
|
| Notes |
| 2018-09-18 10:43:12 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2018-09-07 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-09-07 |
Time |
06:20 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-09-05 |
Time |
14:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-12-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-12-21 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-12-21 |
Time |
10:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-08-15 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-08-15 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-08-15 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2018-08-15 15:13:42 | 08/15/2018 1ST PLUMBING REVIEW **DENIED** WITH COMMENTS | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. ON FORM R405-2017 OF THE FLORIDA ENERGY EFFICIENCY | | | CODE HAS A ELECTRIC HEATER EF 0.92 BUT ON YOUR SHEET 02 | | | IT SHOW A TANKLESS AND ON E-1 IT REFERS IT AS A GAS | | | TANKLESS, PLEASE CLARIFY. WPB AMENDMENTS TO THE FBC | | | SEC.107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | 2. THE HOME HAS A GAS APPLIANCE, AS FOR THE COOK TOP IT | | | HAS A 20 AMP CIRCUIT TO IT, IT?S ON ELECTRICAL LEGEND | | | ON PAGE E-1, AND WILL THE COOK TOP BE GAS OR ELECTRIC, | | | PLEASE CLARIFY. WPB AMENDMENTS TO THE FBC SEC. 107.2.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS. | | | 3. A SEPARATE PERMIT WILL BE REQUIRED FOR GAS AND A | | | REVIEW, WPB AMENDMENTS TO THE FBC SEC. 105.1 REQUIRED | | | APPLICATION FOR PERMIT | | | 4. NO CLEAN OUT REQUIRED AT BASE OF STACK, IF | | | PREFERENCE YOU MAY REQUIRE IT BUT NOT IN THE CODE ONLY | | | OUTSIDE IS REQUIRED. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | | [email protected] | | | 561-805-6720 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2018-12-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-12-21 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-12-21 |
Time |
07:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-09-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-09-18 |
Time |
18:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-09-18 |
Time |
18:26 |
Sent To |
|
|
| Notes |
| 2018-09-18 18:43:50 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE ENERGY EFFICIENCY COMPLIANCE FORM R-405 CONTAINS | | | SEVERAL ERRORS. PLEASE CORRECT. FBC ENERGY CONSERVATION | | | R103.3 | | | | | | A) THE EXTERIOR WALLS ARE LISTED AS WOOD FRAME (R-11) | | | AND THE PLANS SHOW CONCRETE BLOCK (R- 4.1). | | | B) THE EXTERIOR WALLS ARE NOT ALL 8 FEET IN HEIGHT. | | | ONLY THE NORTH WALL IS 8 FEET IN HEIGHT. SEE PLANS. | | | C) THE NORTH WALL HAS ONE 10' X 6'-8" SLIDING GLASS | | | DOOR (WHICH COUNTS AS A WINDOW) AND NOT TWO WINDOWS AS | | | LISTED ON THE FORM. | | | D) THE PLANS SPECIFY A TANKLESS WATER HEATER NOT A 40 | | | GALLON TANK WATER HEATER. | | | E) THE FORM LISTS NO ATTIC AND ALSO A VENTED ATTIC. | | | PLEASE CLARIFY. | | | | | | 2) PROVIDE A NORTH CARDINAL DIRECTIONAL ARROW ON THE | | | PLANS THAT INDICATES THE ORIENTATION OF THE STRUCTURE. | | | FBC 107.2.1 & FBC ENERGY CONSERVATION R405.4.2.1 | | | | | | 3) PROVIDE A CROSS SECTION OF THE ENTIRE STRUCTURE THAT | | | SHOWS A PERPENDICULAR VIEW OF THE ROOF TRUSSES. FBC | | | 107.2.1 | | | | | | 5) SHOW COMPLIANCE WITH FBC-R807 FOR ATTIC ACCESS. | | | | | | 6) THE FLOOR PLAN ON SHEET 1 AND THE SLAB, BEAM AND | | | COLUMN PLAN ON SHEET 02 SPECIFIES A 10' TOP OF BEAM | | | HEIGHT AT THE FRONT OF THE STRUCTURE. THE ELEVATION | | | SHOWS A 14' ELEVATION AT THE FRONT OF THE BUILDING. | | | PLEASE CLARIFY. FBC 107.2.1 | | | | | | 7) PROVIDE A TRUSS BRACING DETAIL. FBC-R802.10.3 | | | | | | 8) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC | | | 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE | | | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER | | | OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH | | | FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS | | | AND MAXIMUM DESIGN PRESSURES FOR EACH OF THE DIFFERENT | | | ROOFING MATERIALS AND EXTERIOR EGRESS ENTRY DOOR. | | | | | | 9) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A | | | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE | | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. DUE TO MISSING | | | INFORMATION FROM THE CONSTRUCTION DOCUMENTS, ADDITIONAL | | | PLAN REVIEW COMMENTS MAY BE GENERATED DURING PLAN | | | RESUBMISSION. | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-12-12 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2018-12-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2018-12-12 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-08-22 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2018-08-22 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2018-08-20 |
Time |
17:15 |
Sent To |
|
|
| Notes |
| 2018-08-22 11:08:10 | *************************************ZONING REVIEW | | | FAILED******************************************* | | | | | | THIS PROPERTY IS ZONED SF-7. THIS IS A SINGLE FAMILY | | | DISTRICT WHICH ONLY PERMITS ONE SINGLE FAMILY HOUSE PER | | | LOT. THERE IS AN EXISTING HOME ON THIS PROPERTY. | | | | | | I SPOKE WITH OWNER, DAVID JUHE, AND HE ADVISED ME THAT | | | THE EXISTING HOME WILL BE DEMOLISHED PRIOR TO RECEIVING | | | CERTIFICATE OF OCCUPANY (CO) FOR THE NEW HOME. HE WROTE | | | A LETTER STATING SUCH, ADDING TO THE FILE. I AM ALSO | | | PLACING A HOLD ON THE CO UNTIL DEMOLITION PERMIT HAS | | | BEEN ISSUED. | | | | | | NEW RESIDENTIAL DEVELOPMENT REQUIRES LANDSCAPING. | | | | | | PLEASE SUBMIT A SEPARATE LANDSCAPE AND IRRIGATION | | | PERMIT. SHOWING THE FOLLOWING: | | | RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM | | | BEACH | | | SECTION 94-442(C)(2)A. SINGLE FAMILY DWELLING UNITS | | | | | | O GROSS LOT SQUARE FOOTAGE MINUS | | | O BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS | | | O OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA) | | | O ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE | | | OR PORTION THEREOF | | | O ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE | | | OR PORTION THEREOF | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] |
|
|