| Plan Review Stops For Permit 18080384 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-12-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-12-08 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-12-08 |
Time |
10:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2018-09-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-02 |
Time |
18:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-02 |
Time |
18:07 |
Sent To |
|
|
| Notes |
| 2018-09-02 18:08:07 | FOR ADDRESSING, PLEASE CONTACT (PREFERABLY VIA EMAIL): | | | | | | MICHAEL ORIO | | | GIS SUPPORT SPECIALIST | | | [email protected] | | | CITY OF WEST PALM BEACH | | | INFORMATION TECHNOLOGY DEPARTMENT | | | 401 CLEMATIS STREET, WEST PALM BEACH, FLORIDA 33401 | | | P: 561.494.1080 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-12-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-12-08 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-11-15 |
Time |
17:13 |
Sent To |
|
|
| Notes |
| 2018-12-08 10:06:30 | PROVISO | | | | | | 1. RESOLVE EXPIRED PERMITS FOR THIS ADDRESS. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-09-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-09-02 |
Time |
18:06 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-02 |
Time |
18:06 |
Sent To |
|
|
| Notes |
| 2018-09-02 18:07:08 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. THIS ADDRESS HAS SEVERAL EXPIRED PERMITS, INCLUDING | | | PERMITS FOR THIS UNIT. WORK IS NOT CONSIDERED | | | "EXISTING" UNLESS IT IS PERMITTED, INSPECTED, AND | | | FINALED. PLEASE RESOLVE EXPIRED PERMITS. | | | | | | 2. A.1, THE ISSUED PERMIT STATED THIS IS ASSEMBLY, IT | | | IS NOW BUSINESS. IS THIS A CHANGE OF OCCUPANCY? IF THIS | | | IS A CHANGE OF OCCUPANCY, PLEASE SEE FBC EB CHAPTER 10; | | | REVISE PLAN TO SHOW COMPLIANCE WITH ALL REQUIREMENTS. | | | PLEASE CONTACT ME IF YOU WISH TO DISCUSS. | | | | | | 3. A.2, A "PLYWOOD PLATFORM" WAS ADDED IN ROOM 107 | | | SUPPORT SPACE. SEE FBC A 202.1.1, EITHER PROVIDE | | | VERTICAL ACCESSIBLITY OR REVISE PLAN TO SHOW APPLICABLE | | | EXCEPTION. | | | | | | 4. A.2, FBC B 1009.15, NO HANDRAILS ARE SHOWN AT THE | | | PLYWOOD PLATFORM WHICH HAS TWO RISERS. EITHER ADD | | | HANDRAILS OR REVISE PLAN TO INCLUDE APPLICABLE | | | EXCEPTION. | | | | | | 5. A.2, FBC A 202.1.1, OPEN OFFICE 101, RAMP WAS | | | REMOVED FROM THE PLAN. IT APPEARS THAT VERTICAL | | | ACCESSIBLITY IS REQUIRED. SEE ALSO FBC A 202.4, AN | | | ACCESSIBLE ROUTE IS REQUIRED. | | | | | | REVISE TO INCLUDE OR PROVIDE RATIONALE VIA EMAIL PRIOR | | | TO RESUBMITTING. | | | | | | 6. FBC 109, VALUE APPEARS LOW. THIS REVISION APPEARS TO | | | ADD SEVERAL OFFICES, $2500 VALUE WAS SUBMITTED. PROVIDE | | | A COST BREAKDOWN. | | | | | | 7. THE ISSUED PERMIT WAS FOR THE INTERIOR OF SUITE 102. | | | THE PLAN REFERRED TO THE SPACE AS "SPACE A". THE | | | REVISION NOW LABELS THIS SPACE "101". PLEASE CORRELATE. | | | AN ADDRESS STOP HAS BEEN ADDED; PLEASE RESOLVE PRIOR TO | | | RESUBMITTING. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-08-27 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-08-27 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-08-24 |
Time |
17:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-08-20 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-08-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-08-20 |
Time |
11:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-12-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-12-08 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-10-12 |
Time |
14:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-09-18 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-09-18 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-08-08 |
Time |
14:50 |
Sent To |
|
|
| Notes |
| 2018-09-18 13:38:49 | TO LMARCHAN. ALL REVIEWS COMPLETED. | | 2018-08-10 14:50:28 | C13 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-11-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-11-08 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-11-08 |
Time |
08:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-09-04 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-09-04 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-09-04 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2018-09-04 14:52:10 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #18080384 | | | 9/4/18 | | | | | | CODES IN EFFECT: | | | | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE NEW 15 TON AC SYSTEMS ARE OVERSIZED. THE | | | CALCULATED SENSIBLE LOADS OF 103.6 MBH (RTU-1) AND | | | 104.4 MBH (RTU-2) INDICATE THAT THE ORIGINAL 12.5 TON | | | UNITS WITH CAPACITIES OF 111.5 MBH ARE CAPABLE OF | | | HANDLING THE LOADS- SECTION C403.2.2 FBC EC. PLEASE | | | NOTE THAT THE SQUARE FOOTAGE CALCULATIONS SHOWN IN THE | | | REVISED AC AND ENERGY CALCULATIONS DO NOT MATCH THE | | | CALCULATIONS SHOWN IN THE ORIGINAL CALCULATIONS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2018-09-11 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-09-11 |
Time |
17:14 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-09-11 |
Time |
17:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-11-14 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2018-11-14 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2018-11-14 |
Time |
13:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-09-18 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2018-09-18 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2018-09-18 |
Time |
13:38 |
Sent To |
|
|
| Notes |
|
|