Plan Review Details - Permit 18080384
Plan Review Stops For Permit 18080384
Review Stop AD ADDRESSING
Rev No 2 Status N Date 2018-12-08 Cont ID  
Sent By shill Date 2018-12-08 Time 10:05 Rev Time 0.00
Received By shill Date 2018-12-08 Time 10:05 Sent To  
Notes
***NONE***

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2018-09-02 Cont ID  
Sent By shill Date 2018-09-02 Time 18:07 Rev Time 0.00
Received By shill Date 2018-09-02 Time 18:07 Sent To  
Notes
2018-09-02 18:08:07FOR ADDRESSING, PLEASE CONTACT (PREFERABLY VIA EMAIL):
  
 MICHAEL ORIO
 GIS SUPPORT SPECIALIST
 [email protected]
 CITY OF WEST PALM BEACH
 INFORMATION TECHNOLOGY DEPARTMENT
 401 CLEMATIS STREET, WEST PALM BEACH, FLORIDA 33401
 P: 561.494.1080
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-12-08 Cont ID  
Sent By shill Date 2018-12-08 Time 10:05 Rev Time 0.00
Received By shill Date 2018-11-15 Time 17:13 Sent To  
Notes
2018-12-08 10:06:30PROVISO
  
 1. RESOLVE EXPIRED PERMITS FOR THIS ADDRESS.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-09-02 Cont ID  
Sent By jwitmer Date 2018-09-02 Time 18:06 Rev Time 0.00
Received By shill Date 2018-09-02 Time 18:06 Sent To  
Notes
2018-09-02 18:07:08****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. THIS ADDRESS HAS SEVERAL EXPIRED PERMITS, INCLUDING
 PERMITS FOR THIS UNIT. WORK IS NOT CONSIDERED
 "EXISTING" UNLESS IT IS PERMITTED, INSPECTED, AND
 FINALED. PLEASE RESOLVE EXPIRED PERMITS.
  
 2. A.1, THE ISSUED PERMIT STATED THIS IS ASSEMBLY, IT
 IS NOW BUSINESS. IS THIS A CHANGE OF OCCUPANCY? IF THIS
 IS A CHANGE OF OCCUPANCY, PLEASE SEE FBC EB CHAPTER 10;
 REVISE PLAN TO SHOW COMPLIANCE WITH ALL REQUIREMENTS.
 PLEASE CONTACT ME IF YOU WISH TO DISCUSS.
  
 3. A.2, A "PLYWOOD PLATFORM" WAS ADDED IN ROOM 107
 SUPPORT SPACE. SEE FBC A 202.1.1, EITHER PROVIDE
 VERTICAL ACCESSIBLITY OR REVISE PLAN TO SHOW APPLICABLE
 EXCEPTION.
  
 4. A.2, FBC B 1009.15, NO HANDRAILS ARE SHOWN AT THE
 PLYWOOD PLATFORM WHICH HAS TWO RISERS. EITHER ADD
 HANDRAILS OR REVISE PLAN TO INCLUDE APPLICABLE
 EXCEPTION.
  
 5. A.2, FBC A 202.1.1, OPEN OFFICE 101, RAMP WAS
 REMOVED FROM THE PLAN. IT APPEARS THAT VERTICAL
 ACCESSIBLITY IS REQUIRED. SEE ALSO FBC A 202.4, AN
 ACCESSIBLE ROUTE IS REQUIRED.
  
 REVISE TO INCLUDE OR PROVIDE RATIONALE VIA EMAIL PRIOR
 TO RESUBMITTING.
  
 6. FBC 109, VALUE APPEARS LOW. THIS REVISION APPEARS TO
 ADD SEVERAL OFFICES, $2500 VALUE WAS SUBMITTED. PROVIDE
 A COST BREAKDOWN.
  
 7. THE ISSUED PERMIT WAS FOR THE INTERIOR OF SUITE 102.
 THE PLAN REFERRED TO THE SPACE AS "SPACE A". THE
 REVISION NOW LABELS THIS SPACE "101". PLEASE CORRELATE.
 AN ADDRESS STOP HAS BEEN ADDED; PLEASE RESOLVE PRIOR TO
 RESUBMITTING.
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2018-08-27 Cont ID  
Sent By jleahy Date 2018-08-27 Time 08:39 Rev Time 0.00
Received By jleahy Date 2018-08-24 Time 17:02 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2018-08-20 Cont ID  
Sent By pleduc Date 2018-08-20 Time   Rev Time 0.00
Received By pleduc Date 2018-08-20 Time 11:58 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-12-08 Cont ID  
Sent By shill Date 2018-12-08 Time 10:06 Rev Time 0.00
Received By shill Date 2018-10-12 Time 14:32 Sent To  
Notes
2018-10-15 14:32:46C16

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-09-18 Cont ID  
Sent By cpuell Date 2018-09-18 Time 15:23 Rev Time 0.00
Received By cpuell Date 2018-08-08 Time 14:50 Sent To  
Notes
2018-09-18 13:38:49TO LMARCHAN. ALL REVIEWS COMPLETED.
2018-08-10 14:50:28C13

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2018-11-08 Cont ID  
Sent By ccole Date 2018-11-08 Time 09:14 Rev Time 0.00
Received By cmontell Date 2018-11-08 Time 08:40 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-09-04 Cont ID  
Sent By ccole Date 2018-09-04 Time 14:30 Rev Time 0.00
Received By ccole Date 2018-09-04 Time 14:30 Sent To  
Notes
2018-09-04 14:52:101ST REVIEW FBC-2017 MECHANICAL
 PERMIT #18080384
 9/4/18
  
 CODES IN EFFECT:
  
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE NEW 15 TON AC SYSTEMS ARE OVERSIZED. THE
 CALCULATED SENSIBLE LOADS OF 103.6 MBH (RTU-1) AND
 104.4 MBH (RTU-2) INDICATE THAT THE ORIGINAL 12.5 TON
 UNITS WITH CAPACITIES OF 111.5 MBH ARE CAPABLE OF
 HANDLING THE LOADS- SECTION C403.2.2 FBC EC. PLEASE
 NOTE THAT THE SQUARE FOOTAGE CALCULATIONS SHOWN IN THE
 REVISED AC AND ENERGY CALCULATIONS DO NOT MATCH THE
 CALCULATIONS SHOWN IN THE ORIGINAL CALCULATIONS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2018-09-11 Cont ID  
Sent By gjohnson Date 2018-09-11 Time 17:14 Rev Time 0.00
Received By gjohnson Date 2018-09-11 Time 17:14 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2018-11-14 Cont ID  
Sent By aaponte Date 2018-11-14 Time 13:28 Rev Time 0.00
Received By aaponte Date 2018-11-14 Time 13:28 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2018-09-18 Cont ID  
Sent By aaponte Date 2018-09-18 Time 13:38 Rev Time 0.00
Received By aaponte Date 2018-09-18 Time 13:38 Sent To  
Notes
***NONE***