Plan Review Details - Permit 18080365
Plan Review Stops For Permit 18080365
Review Stop AD ADDRESSING
Rev No 3 Status P Date 2019-02-21 Cont ID  
Sent By shill Date 2019-02-21 Time 12:19 Rev Time 0.00
Received By shill Date 2019-02-21 Time 12:19 Sent To  
Notes
***NONE***

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2019-01-22 Cont ID  
Sent By shill Date 2019-01-22 Time 11:29 Rev Time 0.00
Received By shill Date 2019-01-22 Time 11:29 Sent To  
Notes
2019-01-22 11:30:24FOR ADDRESSING, PLEASE CONTACT (PREFERABLY VIA EMAIL):
  
 MICHAEL ORIO
 GIS SUPPORT SPECIALIST
 [email protected]
 CITY OF WEST PALM BEACH
 INFORMATION TECHNOLOGY DEPARTMENT
 401 CLEMATIS STREET, WEST PALM BEACH, FLORIDA 33401
 P: 561.494.1080
  
  

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2018-09-21 Cont ID  
Sent By dbattles Date 2018-09-21 Time 13:40 Rev Time 0.00
Received By dbattles Date 2018-09-21 Time 13:40 Sent To  
Notes
2018-09-21 13:41:37THE PERMIT CANNOT BE ISSUED UNTIL AND ADDRESS HAS BEEN
 ASSIGNED TO THE PROPERTY. PLEASE CALL MICHAEL ORIO BY
 PHONE AT 561-494-1080, OR BY E-MAIL [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-01-04 Cont ID  
Sent By dbattles Date 2019-01-04 Time 08:03 Rev Time 0.00
Received By dbattles Date 2018-12-26 Time 12:30 Sent To  
Notes
2019-01-04 08:14:24PROVISO:
 1. PROVIDE PRODUCT APPROVALS FOR WINDOWS AND DOORS.
 2. PROVIDE PRODUCT APPROVALS FOR ROOFING.
 3. TRUSS SHOP DRAWINGS TO BUILDING INSPECTOR PRIOR TO
 INSTALL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-09-21 Cont ID  
Sent By dbattles Date 2018-09-21 Time 13:31 Rev Time 0.00
Received By dbattles Date 2018-09-20 Time 08:56 Sent To  
Notes
2018-09-21 13:32:41****CORRECTIONS****
 W.P.B. PERMIT: 18080365
 1ST REVIEW: SEPTEMBER 21, 2018
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER I
 [email protected]
 561-805-6718
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC AMENDED = FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC ENERGY = FBC ENERGY CONSERVATION
  
 1.[FBC AMENDED 107.2.5]REMOVE SHEET A-1.1.01
 ARCHITECTURAL SITE PLAN. THE UDK PLAN IS THE APPROVED
 SITE PLAN FOR THIS PROJECT AND IT IS ALREADY UPLOADED.
  
 2.[FL. STATUTE 472.025]SURVEY TO BE SEALED BY THE
 SURVEYOR OF RECORD (SEE SIGNATURE REVIEW)
  
 3.[FBC AMENDED 110.3(A)1.1]A FOUNDATION/FORM BOARD
 SURVEY PREPARED AND CERTIFIED BY A REGISTERED SURVEYOR
 MAY BE REQUIRED, PRIOR TO APPROVAL OF THE SLAB
 INSPECTION. THE SURVEY SHALL CERTIFY PLACEMENT OF THE
 BUILDING ON THE SITE, ILLUSTRATE ALL SURROUNDING
 SETBACK DIMENSIONS AND SHALL BE AVAILABLE AT THE JOB
 SITE FOR REVIEW BY THE BUILDING INSPECTOR.
 FL. PLAN A-1.3.01 SHOWS 19.00 F.F.E. CIVIL PLANS ARE IN
 NGVD29.
 IF THE FLOOR PLAN IS IN NAVD88 THAN USE CONVERSION FROM
 NGVD29 TO NAVD88.
  
 4.[FBC AMENDED 109]COST EVALUATION IS LOW FOR THE
 SQUARE FOOT COST OF CONSTRUCTION. PLEASE PROVIDE
 DOCUMENTATION OF HOW THIS NUMBER WAS DERIVED. CURRENT
 ICC COST EVALUATION FOR VB CONSTRUCTION IS $133.67 PER
 SQ. FT. FOR BUSINESS AND $127.52 FOR A-3 ASSEMBLY.
  
 5.[FBC ENERGY C401.2]APPLICATION.
 COMMERCIAL BUILDINGS SHALL COMPLY WITH ONE OF THE
 FOLLOWING:
 1)THE REQUIREMENTS OF ANSI/ASHRAE/IESNA 90.1, EXCLUDING
 SECTION 9.4.1.1(G) OF THE STANDARD.
 2)THE REQUIREMENTS OF SECTIONS C402 THROUGH C405. IN
 ADDITION, COMMERCIAL BUILDINGS SHALL COMPLY WITH
 SECTION C406 AND TENANT SPACES SHALL COMPLY WITH
 SECTION C406.1.1.
 3)THE REQUIREMENTS OF SECTIONS C402.5, C403.2, C404,
 C405.2, C405.3, C405.5, C405.6 AND C407. THE BUILDING
 ENERGY COST SHALL BE EQUAL TO OR LESS THAN 85 PERCENT
 OF THE STANDARD REFERENCE DESIGN BUILDING.
  
 6.[FBC 107.2.5]ADD SHEET A-0.0.02 TO INDEX. THIS SHEET
 WILL RECEIVE DIGITAL STAMP FOR BUILDING REVIEW AND I
 WOULD LIKE ALL SHEETS PROVIDED TO BE LISTED ON THAT
 PAGE.
  
 7.[FBC TABLE 1017.2]UPDATE MAX. TRAVEL DISTANCE CHART
 FOR THE OCCUPANCIES FOR B-BUSINESS AND A-3 ASSEMBLY.
 ALSO, UPDATE GENERAL NOTES AND LIFE SAFETY NOTES TO
 REFLECT LIFE SAFETY SYSTEMS TO BE USED IN THIS
 BUILDING.
  
 8.[FBC 1609.6.4.4.1]COMPONENTS AND CLADDING.
 SHEET S-4.01 UPDATE CODE REFERENCES TO FBC 2017 6TH
 EDITION.
 PROVIDE +/- PRESSURES FOR EACH OPENING.
  
 9.SHEET A-3.2.01 SHOWS 3X10 WOOD RAFTERS AND CALLS OUT
 TO SEE STRUCTURAL FOR ATTACHMENT. SHEET S-3.01 SHOWS
 CONCRETE PORTION. PLEASE SHOW STRUCTURAL CONNECTIONS OF
 THE 3X10?S.
  
 10.SHEET A-3.2.02 CALLS OUT 5/8 PLYWOOD, BUT STRUCTURAL
 SHEET S-2.02 IS CALLING 3/4. PLEASE CO-ORDINATE THE
 PLYWOOD SIZE.
  
 11.[FBC TABLE 1604.3]PROVIDE DEFLECTION LIMITS OF
 TRUSSES.
  
 12.[FBC 1507.4.2]DECK SLOPE. THE MINIMUM SLOPE FOR
 LAPPED, NONSOLDERED SEAM METAL ROOF PANELS WITHOUT
 APPLIED LAP SEALANT SHALL BE THREE UNITS VERTICAL IN 12
 UNITS HORIZONTAL (25-PERCENT SLOPE).
 ADD NOTE THAT METAL PANELS ON 2/12 PITCH WILL HAVE
 APPLIED LAP SEALANT.
  
 PRODUCT APPROVALS:
  
 13.[FBC AMENDED 107.2.1.2]PROVIDE PRODUCT APPROVALS FOR
 WINDOWS AND DOORS, OR INDICATE THAT YOU WOULD LIKE THEM
 DEFFERED.
  
 14.[FBC AMENDED 107.2.1.2]PROVIDE PRODUCT APPROVALS FOR
 ROOFING, OR INDICATE THAT YOU WOULD LIKE THEM DEFFERED.
  
 -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
 -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW
 OF MATERIALS REQUESTED.
 -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-01-02 Cont ID  
Sent By jpearson Date 2019-01-02 Time 15:45 Rev Time 0.00
Received By jpearson Date 2019-01-02 Time 15:45 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2018-09-18 Cont ID  
Sent By jpearson Date 2018-09-18 Time 14:40 Rev Time 0.00
Received By jpearson Date 2018-09-18 Time 14:40 Sent To  
Notes
***NONE***

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2019-01-02 Cont ID  
Sent By jpearson Date 2019-01-02 Time 15:45 Rev Time 0.00
Received By jpearson Date 2019-01-02 Time 15:45 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 3 Status N Date 2019-02-21 Cont ID  
Sent By rrossano Date 2019-02-21 Time   Rev Time 0.00
Received By rrossano Date 2019-02-21 Time   Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2019-01-22 Cont ID  
Sent By shill Date 2019-01-22 Time 11:30 Rev Time 0.00
Received By shill Date 2019-01-22 Time 11:30 Sent To  
Notes
2019-01-22 11:30:59UNDER ENGINEERING REVIEW.
  
 FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR
 CONCERNS, THANKS.
  
 RICK ROSSANO
 PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1098
 FAX: (561) 494-1116
 MOBILE: (561) 246-9525
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
 MANNY GONZALEZ
 SENIOR ENGINEERING PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2018-09-12 Cont ID  
Sent By RRossano Date 2018-09-12 Time   Rev Time 1.00
Received By rrossano Date 2018-09-12 Time   Sent To I
Notes
2018-09-12 12:35:37UNDER ENGINEERING REVIEW.
  
 FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR
 CONCERNS, THANKS.
  
 RICK ROSSANO
 PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1098
 FAX: (561) 494-1116
 MOBILE: (561) 246-9525
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
 MANNY GONZALEZ
 SENIOR ENGINEERING PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2018-12-17 Cont ID  
Sent By scaldero Date 2018-12-17 Time 09:34 Rev Time 0.00
Received By scaldero Date 2018-12-17 Time 09:14 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2018-08-16 Cont ID  
Sent By scaldero Date 2018-08-16 Time 10:26 Rev Time 0.00
Received By scaldero Date 2018-08-14 Time 11:40 Sent To  
Notes
2018-08-16 10:26:42PERMIT # 18080365
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 FAILED REVIEW COMMENTS:
  
 1) UPDATE THE CODE LIST TO REFERENCE THE 6TH EDITION OF
 THE FLORIDA FIRE PREVENTION CODE WHICH CONTAINS THE
 2015 EDITION OF BOTH NFPA 1 AND NFPA 101 WITH FLORIDA
 AMENDMENTS.
  
 2) STRUCTURES WITH LIGHT FRAME FLOOR/ROOF TRUSS
 CONSTRUCTION SHALL BE IDENTIFIED WITH A SIGN AFFIXED TO
 THE BUILDING. THE SIGN SHALL FEATURE A MALTESE CROSS
 8-INCHES WIDE AND 8-INCHES TALL AND BE OF A BRIGHT RED
 REFLECTIVE COLOR AND BEAR THE APPROPRIATE LETTER R/F/RF
 DESIGNATION PER FLORIDA STATUTE 633.027 AND FLORIDA
 ADMINISTRATIVE CODE 69A-60.0081.
  
 3) THE BUILDING IS FUNCTIONING AS A MULTIUSE OCCUPANCY.
 INDICATE IF THE BUILDING IS DESIGNED FOR MIXED USE
 (NON-SEPARATED) OR SEPARATED USE PER SECTION 6.1.14.3
 OF NFPA 101 FLORIDA EDITION 2015. FOR NON-SEPARATED
 MIXED USE OCCUPANCIES, THE MOST STRINGENT FIRE AND LIFE
 SAFETY REQUIREMENTS OF EACH OCCUPANCY SHALL APPLY TO
 THE BUILDING.
  
 4) SHEET A-1.2.01: PLEASE INDICATE THE COMMON THE PATH
 OF TRAVEL FOR THE CARD ROOM AREA.
  
 5) PROJECT DATA SHEET STATES THAT THIS IS AN
 UNSPRINKLED BUILDING, HOWEVER THE LIFE SAFETY SHEET
 REFERS YOU TO THE FIRE PROTECTION AND FIRE ALARM
 DRAWINGS FOR DEVICE AND SPRINKLER HEAD PLACEMENT.
 PLEASE VERIFY AND CORRECT INFORMATION. WILL THE
 BUILDING HAVE A FULL FIRE SPRINKLER AND/OR FIRE ALARM
 SYSTEM.
 NOTE: SPRINKLER AND ALARM DRAWINGS NOT PROVIDED WITH
 THIS SUBMISSION.
  
 6) IF THE BUILDING WILL HAVE A FULL FIRE SPRINKLER
 AND/OR FIRE ALARM SYSTEM: ENGINEERED FIRE ALARM AND
 FIRE SPRINKLER CONSTRUCTION DOCUMENTS ARE REQUIRED FOR
 A GENERAL BUILDING PERMIT. AFTER THE BUILDING PERMIT
 HAS BEEN ISSUED, THE SUBCONTRACTORS CAN THEN SUBMIT
 SHOP DRAWINGS (CONFORMING TO THE ENGINEERED
 CONSTRUCTION DOCUMENTS) FOR A SUB-PERMIT.
  
 7) A THOROUGH AND COMPLETE PLAN REVIEW CANNOT BE
 COMPLETED AT THIS TIME DUE TO LACK OF INFORMATION
 SUBMITTED ON THE PLANS. ADDITIONAL PLAN REVIEW COMMENTS
 MAY BE GENERATED DURING PLAN RESUBMISSION.
  
  
 SUE ELLEN CALDERON
 ASSISTANT FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-02-12 Cont ID  
Sent By lmarchan Date 2019-02-12 Time 13:36 Rev Time 0.00
Received By lmarchan Date 2018-12-13 Time 08:18 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-10-11 Cont ID  
Sent By cpuell Date 2018-10-11 Time 09:23 Rev Time 0.00
Received By cpuell Date 2018-08-10 Time 12:36 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By lmarchan Date 2019-03-06 Time 10:27 Sent To  
Notes
2019-03-06 10:27:593/6/19 EMAILED IMPACT FEE OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2018-09-20 Cont ID  
Sent By dbattles Date 2018-09-20 Time 13:02 Rev Time 0.00
Received By dbattles Date 2018-09-20 Time 13:02 Sent To  
Notes
2018-09-20 13:02:44[FBC AMENDED 109]PLANS WILL BE REVIEWED BY THE PBC
 IMPACT FEE OFFICE DIGITALLY VIA PROJECTDOX UPON
 NOTIFICATION BY THIS OFFICE. NOTIFICATION MAY OCCUR
 WHEN PLANS ARE NEAREST FINAL FORM. YOU MAY COORDINATE
 WITH THE IMPACT FEE OFFICE AT (561) 233-5025 OR SIMPLY
 UPLOAD THE MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO
 YOUR PROJECT AND NAME THE FILE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE. THE FORM CAN BE FOUND AT: HTTP://DISCOVE
 R.PBCGOV.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QU
 ESTIONNAIRE.PDF UPON APPROVAL AND FEE PAYMENT, PLEASE
 UPLOAD THE RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-01-07 Cont ID  
Sent By ccole Date 2019-01-07 Time 14:10 Rev Time 0.00
Received By ccole Date 2019-01-07 Time 14:01 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-09-19 Cont ID  
Sent By ccole Date 2018-09-19 Time 08:29 Rev Time 0.00
Received By ccole Date 2018-09-18 Time 17:25 Sent To  
Notes
2018-09-19 09:43:511ST REVIEW FBC-2017 MECHANICAL
 PERMIT #18080365
 9/19/18
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SUBMIT AN ENERGY COMPLIANCE REPORT- SEE SECTIONS
 C101.2, C101.5.1 AND C401.2 FBC EC.
  
 2) PROVIDE AC COOLING AND HEATING CALCULATIONS IN
 ACCORDANCE WITH SECTION C403.2.1 FBC EC.
  
 3) SHEET M-1.3.01: IT APPEARS THAT FIRE DAMPERS ARE
 MISSING FOR THE 24X20 AND 26X18 DUCTS PENETRATING THE
 MECHANICAL ROOM WALLS- SECTION 607.5.2 FBC M. PLEASE
 CLARIFY THESE WHY THE MECHANICAL AND ELECTRICAL ROOM
 WALLS ARE NOT SHOWN AS FIRE-RATED IN THE LIFE SAFETY,
 AND ARCHITECTURAL PLANS INCLUDING SHEET A-6.6.01 WALL
 TYPES.
  
 4) PROVIDE WIND LOAD ENGINEERING FOR TIE DOWN OF THE AC
 CONDENSERS- SECTION 301.15 FBC M.
  
 5) SUBMIT A MANUFACTURER'S SPEC SHEET AND A MIAMI-DADE
 NOA AND/OR A FL. PRODUCT APPROVAL FOR THE O/A INTAKE
 LOUVER- SEE SECTION 401.5 FBC M. VERIFY COMPLIANCE WITH
 SECTION 401.4 FOR INTAKE CLEARANCES TO LOT LINES, DRIVE
 AREAS ETC.
  
 6) M-1.3.01: DEMAND CONTROLLED VENTILATION FOR THE CARD
 ROOM IS REQUIRED PER SECTION C403.2.6.1 FBC EC.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-01-15 Cont ID  
Sent By gjohnson Date 2019-01-15 Time 11:27 Rev Time 0.00
Received By gjohnson Date 2019-01-15 Time 11:27 Sent To  
Notes
2019-01-15 11:27:28PROVISO:
  
 SHALL COMPLY BY FINAL INSPECTION.
  
 1. PROVIDE A DETAIL SHOWING THE BACKING AND ATTACHMENT
 OF THE WATER HEATER SHELF AND A SIGNED AND SEALED
 LETTER FROM ENGINEER OF RECORD STATING THE SHELF IS
 DESIGNED TO CARRY THE LOAD OF THE WATER HEATER. PER WPB
 AMEND TO FBC 107.2.1

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-09-26 Cont ID  
Sent By gjohnson Date 2018-09-26 Time 15:01 Rev Time 0.00
Received By gjohnson Date 2018-09-26 Time 15:01 Sent To  
Notes
2018-09-26 15:32:301ST REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. THE SINKS IN THE BREAKROOM AND THE CARD ROOM SHALL
 COMPLY WITH FBC ACC WHERE SINKS ARE PROVIDED, AT LEAST
 5 PERCENT, BUT NO FEWER THAN ONE, OF EACH TYPE PROVIDED
 IN EACH ACCESSIBLE ROOM OR SPACE SHALL COMPLY WITH 606.
 606.2 CLEAR FLOOR SPACE.A CLEAR FLOOR SPACE COMPLYING
 WITH 305, POSITIONED FOR A FORWARD APPROACH, AND KNEE
 AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE PROVIDED
 606.3 HEIGHT.LAVATORIES AND SINKS SHALL BE INSTALLED
 WITH THE FRONT OF THE HIGHER OF THE RIM OR COUNTER
 SURFACE 34 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR
 GROUND.
  
 2. SHT. P-1.3.01 THE 3" HUB DRAIN IN THE MECHANICAL
 RECEIVING DISCHARGE FROM THE AC UNITS IS A CODE
 VIOLATION CONDENSATE SHALL NOT DISCHARGE INTO THE
 SANITY SYSTEM. PER WPB CODE OF ORDINANCES SEC.
 90-126(5)
  
 3. PROVIDE AN ENGINEERED DETAIL FOR WATER HEATER SHELF
 . WPB AMEND TO FBC 107.2.1
  
 4. TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES
 AND GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET
 FACILITIES PROVIDED FOR CUSTOMERS, PATRONS AND
 VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN
 APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT
 CONFORMS TO ASSE 1070 OR CSA B125.3. PER FBC PL 416.5
  
 5. PLEASE PROVIDE A WATER AND SANITARY ISOMETRIC
 DRAWINGS. PER WPB AMEND TO FBC 107.3.5.1.3(13)
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2019-01-04 Cont ID  
Sent By dbattles Date 2019-01-04 Time 08:17 Rev Time 0.00
Received By dbattles Date 2019-01-04 Time 08:16 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2019-03-14 Cont ID  
Sent By shill Date 2019-03-14 Time 09:52 Rev Time 0.00
Received By shill Date 2019-03-14 Time 09:52 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2019-01-22 Cont ID  
Sent By shill Date 2019-01-22 Time 11:31 Rev Time 0.00
Received By shill Date 2018-12-26 Time 12:28 Sent To  
Notes
2019-01-22 11:32:01NEW PAGES SUBMITTED NEED VERIFICATION - A & S SHEETS OK
 NEED PAPER ORIGINAL FOR CIVIL SHEETS
  
  
  
2019-01-15 11:45:511/15/19 DIGITAL SIGNATURE ON PLUMBING SHEETS OK/GPJ
2019-01-02 15:26:57ELECTRICAL SHEETS OK.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2018-09-20 Cont ID  
Sent By dbattles Date 2018-09-20 Time 12:54 Rev Time 0.00
Received By dbattles Date 2018-09-20 Time 12:54 Sent To  
Notes
2018-09-20 13:02:02001-029 A-SHEETS - OK
 030-048 CIVIL SHEETS - NO DIGITAL SIGNATURE. DWG'S SHOW
 THERE WAS A DIGITAL SIGNATURE, BUT IT DOESN'T HAVE
 ELECTRONIC FINGERPRINT.
 049-055 L-SHEETS - OK
 056-062 S-SHEETS - OK
 063-065 SURVEY - DIGITAL SIGNATURE BY SURVEY COMPANY,
 BUT NO SEAL ON DWG.
 066-077 E-SHEETS - OK
 078-082 M-SHEETS - OK
 083-089 M-SHEETS - OK
  
 FINAL SIGNATURE APPROVAL PENDING RE-SUBMITTAL.
 1. UPLOAD CIVIL WITH DIGITAL SIGNATURE, OR PROVIDE HARD
 COPY WITH RAISED SEAL ONCE APPROVED.
 2. UPLOAD SURVEY WITH SEAL TO INCLUDE NAME OF SURYEYOR
 OF RECORD AND LICENSE NUMBER, OR PROVIDE HARD COPY WITH
 RAISED SEAL ONCE APPROVED.
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2019-02-12 Cont ID  
Sent By jroach Date 2019-02-12 Time 13:23 Rev Time 0.00
Received By jroach Date 2019-02-12 Time 13:23 Sent To  
Notes
2019-02-12 13:27:43ZONING PLAN REVIEW
 ___________________________________________
  
 DATE OF REVIEW: 02.12.2019
 PERMIT NO.: 18080365
 ___________________________________________
  
 REVIEW STATUS: PASSED WITH PROVISOS
 ___________________________________________
  
 THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING
 PROVISOS:
  
 1. CONSTRUCTION OF THE ADMIN BUILDING IS SUBJECT TO THE
 BANYAN CAY RPD/CPD DEVELOPMENT ORDER, APPROVED VIA
 RESOLUTION NO. 307-17 (AS AMENDED), AND ALL OF THE
 CONDITIONS CONTAINED THEREIN.
  
 2. SEPARATE PERMITS REQUIRED FOR SITE WORK,
 LANDSCAPING, IRRIGATION, ETC.
  
 3. ALL SITE IMPROVEMENTS, LANDSCAPING, ETC. SHALL BE
 COMPLETED PRIOR TO THE ISSUANCE OF A CERTIFICATE OF
 OCCUPANCY.
 ___________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
  
 E: [email protected]
  
 W: WPB.ORG
  

Review Stop Z ZONING
Rev No 1 Status F Date 2018-10-11 Cont ID  
Sent By jroach Date 2018-10-11 Time 09:03 Rev Time 0.00
Received By jroach Date 2018-10-11 Time 08:46 Sent To  
Notes
2018-10-11 09:03:20REVIEW STATUS: FAILED
 ___________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. THE PERMIT SUBMITTAL INCLUDES MULTIPLE SITE PLANS.
 PLEASE PROVIDE ONLY ONE SITE PLAN THAT INCLUDES ALL FO
 THE REQUIRE DATA, DIMENSIONS, ETC. THE SITE PLAN
 PROVIDED SHOULD BE THE MOST RECENT UDKS PLAN
 SUBMITTED/APPROVED. THE SITE PLANS INCLUDED WITH THIS
 PERMIT APPLICATION DO NOT MATCH THE MOST RECENT UDKS
 PLAN AS THE BUILDING HAS BEEN ROTATED.
  
 2. LANDSCAPING SHALL BE SUBMITTED AS A SEPARATE PERMIT.
 ENSURE THAT THE LANDSCAPE PLANS MATCH THE MOST RECENT
 SUBMITTAL/APPROVAL BY UDKS.
 ___________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 F: 561.822.1460
  
 E: [email protected]
  
 W: WPB.ORG
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved