| Plan Review Stops For Permit 18080351 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-08-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-08-28 |
Time |
18:58 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-08-28 |
Time |
18:50 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-08-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-08-15 |
Time |
07:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-08-15 |
Time |
07:41 |
Sent To |
I |
|
| Notes |
| 2018-08-15 07:51:45 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE PLANS HAVE SEVERAL REFERENCES TO THE FBC FIFTH | | | EDITION (2014). THE FBC SIXTH EDITION (2017) WENT INTO | | | EFFECT ON JANUARY 1, 2018. ALL NEW PERMITS APPLIED FOR | | | ON OR AFTER THAT DATE ARE REQUIRED TO COMPLY WITH AND | | | REFERENCE THE FBC SIXTH EDITION (2017). | | | FS CHAPTER 553 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-08-30 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-08-30 |
Time |
17:17 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-08-30 |
Time |
17:17 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-08-11 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-08-11 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-08-11 |
Time |
12:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2018-08-13 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-08-13 |
Time |
18:17 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-08-13 |
Time |
18:17 |
Sent To |
|
|
| Notes |
| 2018-08-13 18:17:30 | HEATER IS ELECTRIC TYPE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-08-31 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-08-31 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-08-21 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2018-08-22 14:19:16 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-08-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-08-15 |
Time |
07:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-08-07 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2018-08-08 10:58:39 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-08-31 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-08-31 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-08-31 |
Time |
16:23 |
Sent To |
|
|
| Notes |
| 2018-08-31 16:24:20 | 08/31/18 REVIEWED FOR CODE COMPLIANCE (PLUMBING/POOL) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVE PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-08-13 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-08-13 |
Time |
18:17 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-08-13 |
Time |
18:17 |
Sent To |
|
|
| Notes |
| 2018-08-13 18:18:21 | 08/13/2018 1ST PLUMBING/POOL REVIEW **DENIED** WITH | | | COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. SUBMIT TOTAL DYNAMIC HEAD CALCULATIONS FOR THE | | | MAXIMUM SYSTEM FLOW. THE MAXIMUM FLOW OF THE PUMP FROM | | | ITS PUMP CURVE IS NO LONGER ALLOWED TO BE USED IN | | | DETERMINING THE MAXIMUM SYSTEM FLOW RATE PER | | | ANSI/APSP/ICC 7 - 2013 SECS. 4.4.9, 4.4.9.1. THE 2013 | | | EDITION ADDRESSES FLOW RATE IN GALLONS PER MINUTE | | | (GPM). IT REQUIRES THAT MAXIMUM SYSTEM FLOW RATE DOES | | | NOT EXCEED THE LISTED MAXIMUM FLOW RATE OF THE SUCTION | | | OUTLET FITTING ASSEMBLY (DRAIN COVER).THE TDH | | | CALCULATIONS MUST INCLUDE ALL OF THE SYSTEM COMPONENTS | | | IN THE PIPING SYSTEM INCLUDING THE FILTER. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | | [email protected] | | | 561-805-6720 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-08-28 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-08-28 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-08-28 |
Time |
08:46 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-08-10 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-08-10 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-08-10 |
Time |
15:13 |
Sent To |
B |
|
| Notes |
|
|