Plan Review Details - Permit 18080279
| Plan Review Stops For Permit 18080279 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-10-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-10-16 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-10-16 |
Time |
15:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-10-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-10-15 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-10-12 |
Time |
16:20 |
Sent To |
|
|
| Notes |
| 2018-10-15 10:03:30 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1-2. OK | | | | | | 3. COMMENT FROM PREVIOUS LIST - THI SINFORMATION MAY BE | | | SENT VIA EMAIL. | | | | | | FBC 109, VALUE IS TO INCLUDE ALL LABOR, MATERIALS, | | | OVERHEAD, PROFIT, DESIGN FEES, INCLUDING ITEMS PROVIDED | | | BY OTHERS. | | | | | | 4. COMMENT FROM PREVIOUS LIST - THIS INFORMATION MAY BE | | | SENT VIA EMAIL. | | | | | | PLEASE ADVISE, WHAT FLOORING AND UNDERLAYMENT ARE | | | PROPOSED? PLEASE ADVISE VIA EMAIL PRIOR TO | | | RESUBMITTING. IF THE UNDERLAYMENT PRODUCT PROPOSED IS | | | NOT ONE FOR WHICH WE HAVE TEST REPORTS ON FILE, THE | | | FOLLOWING REPORTS ARE REQUIRED: | | | | | | MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO | | | DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST | | | REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE | | | MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT) | | | | | | A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90. | | | THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM | | | CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | | ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED | | | GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | | OR UL 723. | | | | | | 5. OK - PER CONTRACTOR, WINDOWS/DOORS ARE NOT WITHIN | | | THE SCOPE OF THIS PERMIT. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-09-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-02 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-02 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2018-09-02 16:01:10 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC B 1609, NEW SLIDERS AND WINDOW ARE PROPOSED, BUT | | | NO DESIGN PRESSURES SPECIFIED. | | | | | | 2. FBC B 1609, CONSTRUCTION NOTES STATE THIS IS | | | EXPOSURE B, REVISE. | | | | | | 3. FBC 109, VALUE IS TO INCLUDE ALL LABOR, MATERIALS, | | | OVERHEAD, PROFIT, DESIGN FEES, INCLUDING ITEMS PROVIDED | | | BY OTHERS. | | | | | | 4. PLEASE ADVISE, WHAT FLOORING AND UNDERLAYMENT ARE | | | PROPOSED? PLEASE ADVISE VIA EMAIL PRIOR TO | | | RESUBMITTING. IF THE UNDERLAYMENT PRODUCT PROPOSED IS | | | NOT ONE FOR WHICH WE HAVE TEST REPORTS ON FILE, THE | | | FOLLOWING REPORTS ARE REQUIRED: | | | | | | MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO | | | DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST | | | REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE | | | MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT) | | | | | | A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90. | | | THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM | | | CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | | ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED | | | GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | | OR UL 723. | | | | | | 5. ARE THE WINDOW AND SLIDER PRODUCTS PROPOSED KNOWN AT | | | THIS TIME? IF YES, PROVIDE PRODUCT APPROVALS REVIEWED | | | BY DESIGNER OF RECORD. IF NO, THIS WILL BE A PROVISO | | | ITEM, SUBMIT FOR REVIEW PRIOR TO INSTALLATION. | | | | | | ON THE PRODUCT APPROVALS, INDICATE METHOD OF | | | INSTALLATION TO SHOW COMPLIANCE WITH DESIGN PRESSURES | | | SPECIFIED. | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-10-01 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-10-01 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-10-01 |
Time |
08:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-08-29 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-08-29 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-08-29 |
Time |
06:43 |
Sent To |
|
|
| Notes |
| 2018-08-29 11:12:08 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. ELECTRICAL PERMIT APPLICATION STATES THAT THE | | | ELECTRICAL PANEL WILL BE CHANGED. PROVIDE LOCATION OF | | | PANEL ON PLANS. WPB FBC 107.2.1 | | | 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | | 408.4 | | | 3. SHOW REQUIRED RECEPTACLE OUTLETS PER NEC 210.52 IN | | | AREAS REMODELED. NEC 210.52; WPB FBC 107.2.1 | | | 4. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS | | | INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES. | | | SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION. | | | PROVIDE CORRECTION. NEC 210.8, 210.12 | | | 5. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC 210.8(D) | | | 6. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD | | | SHEETS?. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-09-18 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-09-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-09-18 |
Time |
11:59 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-08-09 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-08-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-08-08 |
Time |
12:16 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-10-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-10-15 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-14 |
Time |
11:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-09-04 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-09-04 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-08-06 |
Time |
16:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-10-04 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2018-10-04 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-10-04 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2018-10-04 10:27:53 | 2ND REVIEW: | | | PLUMBING COMMENTS: APPROVED | | | | | | 1. REVIEWED REVISED PLAN FOR WHICH PLUMBING HAD BEEN | | | PREVIOUSLY APPROVED BY GEORGE JOHNSON. THERE WAS NO | | | CHANGE THAT APPLIED TO PLUMBING. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2018-09-04 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-09-04 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-09-04 |
Time |
15:02 |
Sent To |
|
|
| Notes |
|
|
|