| Plan Review Stops For Permit 18080276 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-11-01 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-11-01 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-11-01 |
Time |
09:44 |
Sent To |
|
|
| Notes |
| 2018-11-01 09:49:39 | PROVISO: | | | 1. TRUSS SUBMITTAL TO INSPECTOR PRIOR TO INSTALL. | | | 2. STAIRS, GUARD RAILS ENGINEERING SUBMITTAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-09-14 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-09-14 |
Time |
08:01 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-09-12 |
Time |
13:15 |
Sent To |
|
|
| Notes |
| 2018-09-14 08:03:01 | W.P.B. PERMIT: 18080276 (GARAGE) | | | REVIEWED: SEPTEMBER 13, 2018 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER I | | | [email protected] | | | 561-805-6718 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC A = AMENDMENTS TO THE FLORIDA BUILDING CODE,6TH | | | EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | [FBC AMENDED 105]SEPARATE PERMIT THROUGH ENGINEERING | | | FOR DRIVEWAY ACCESS. CONTACT 561-494-1040, OR ON THE | | | WEB: HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC- | | | WORKS/ENGINEERING-SERVICES | | | | | | 1. [FBC 107.2.5]SHEET 1 WIND INFORMATION-REMOVE LEVEL | | | OF ALTERATION 2. THIS WOULD BE NEW CONSTRUCTION R-3. | | | | | | 2. [FBC R301.4]DEAD LOAD AND[FBC R301.5]LIVE LOAD | | | PROVIDE LOADS FOR FLOORING AND LOADS FOR ROOFING ON | | | SHEET 4. | | | | | | 3. [FBC AMENDED 107.2.1.2]PROVIDE TWO COPIES OF PRODUCT | | | APPROVAL FOR GARAGE DOOR. | | | | | | 4. [FBC 107.3.4.1]A CONSTRUCTION GUARDRAIL DETAIL, | | | PREPARED BY A DESIGN PROFESSIONAL LICENSED UNDER FS471 | | | OR FS481, IS REQUIRED TO BE SUBMITTED, REVIEWED AND | | | ISSUED BY THE CITY OF WEST PALM BEACH, OR INDICATE THAT | | | IT WILL BE DEFERRED. | | | *SUBJECT TO THE INSPECTOR'S DISCRETION, THIS MAY BE | | | ACCEPTED IN THE FIELD AT TIME OF INSPECTION. | | | | | | 5. [FBC AMENDED 107.3.4.1]SUBMIT TRUSS SHOP DRAWINGS, | | | OR INDICATE THAT THE SUBMITTAL WILL BE DEFERRED. | | | DEFERRED SUBMITTALS TO BE REVIEWED PRIOR TO | | | INSTALLATION. | | | | | | 6. [FBC R3-1.2(6)]PROVIDE ROOFING WIND DIAGRAM THAT | | | MATCHES THE ROOF CONDITION OF THIS HOUSE FOR ZONES | | | 1,2,& 3. | | | | | | 7. [FBC R304.2]MINIMUM DIMENSIONS. | | | HABITABLE ROOMS SHALL BE NOT LESS THAN 7 FEET (2134 MM) | | | IN ANY HORIZONTAL DIMENSION. ALSO, LABEL EGRESS WINDOW | | | FOR THE BEDROOM. | | | | | | 8. [FBC 107.2.5]SHEET 2: 1/2 STAIR DETAIL. WITH THE | | | WEIGHT OF WOOD STAIRCASE VERIFY IF THE 4? SLAB IS | | | SUFFICIENT BEARING. | | | | | | 9. [FBC 107.2.5]SHEET 4: | | | A.UPDATE CONNECTOR H10A TO REFERENCE CURRENT FL 10456.2 | | | B.FLOOR FRAMING PLAN REFERANCES SECTION 2/5 AT BALCONY, | | | BUT THIS DETAIL IS FOR STAIRS WITH POSTS. PROVIDE | | | DETAIL FOR CANTILEVER BALCONY INSTEAD OF STAIR LANDING. | | | | | | 10. [FBC 107.2.5]SHEET 5: SECTION 2/5 SECOND FLOOR | | | BALCONY. 5/8 CDX PLYWOOD IS CALLED OUT UNDER THE | | | DECKING MATERIAL. ID THIS EXTERIOR GRADE AND HOW ARE | | | EDGES PROTECTED FROM WATER? | | | | | | 11. [FBC R309.1]FLOOR SURFACE. | | | THE AREA OF FLOOR USED FOR PARKING OF AUTOMOBILES OR | | | OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE | | | MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE MAIN | | | VEHICLE ENTRY DOORWAY. | | | | | | 12. [FBC ENERGY R401.2]PROVIDE ENERGY CALCULATIONS TO | | | MEET REQUIREMENTS IN R401.2 RESIDENTIAL ENERGY CODE. | | | CHOOSE METHOD IN R401.2 AND SUPPLY DOCUMENTATION. | | | | | | NOTE: | | | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | | OF MATERIALS REQUESTED. | | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2018-11-20 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-11-20 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-11-20 |
Time |
09:23 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2018-11-09 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-11-09 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-11-09 |
Time |
08:56 |
Sent To |
|
|
| Notes |
| 2018-11-09 08:56:03 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. CORRECTED. | | | 2. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10; FBC RE E3603.3 (NOT PROVIDED, NOTED | | | THAT WILL BE PROVIDED BEFORE INSPECTION.) | | | 3. PROVIDE AIC RATING OF SERVICE DISCONNECT AND PANEL. | | | NEC 110.3, 110.9; FBC RE E3603.3 (NOT PROVIDED AS NOTED | | | ON RESPONSE LETTER.) | | | 4. CORRECTED. | | | 5. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | | 210.8(D); FBC RE E3902.10 (NOT PROVIDED.) | | | 6. CORRECTED. | | | 7. CORRECTED. | | | 8. CORRECTED. | | | 9. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS. NEC 220; FBC RE E3602.2 (LOAD CALCULATION | | | PROVIDED DOES NOT INCLUDE ALL LOADS, DOES NOT INCLUDE | | | GARAGE PANEL, LOAD FOR TANKLESS HEATER NOT INCLUDED. | | | PROVIDE LOAD CALCULATION FOR ENTIRE SERVICE AS | | | REQUESTED.) | | | 10. CORRECTED. | | | 11. RECEPTACLE OUTLETS INSTALLED IN LAUNDRY AREAS SHALL | | | HAVE GFCI PROTECTION. PROVIDE CORRECTION. NEC | | | 210.8(A)(9); FBC RE E3902.9 (NOT PROVIDED.) | | | 12. LIGHTING MUST MAINTAIN PROPER CLEARANCES FROM THE | | | NEAREST POINT OF STORAGE SPACE IN A CLOTHES CLOSET. | | | PROVIDE CORRECTION. NEC 410.16; FBC RE E4003.12 (NOT | | | CORRECTED.) | | | 13. CORRECTED. | | | 14. CORRECTED. | | | 15. CORRECTED. | | | 16. CORRECTED. | | | 17. CORRECTED. | | | 18. CORRECTED. | | | 19. CORRECTED. | | | 20. CORRECTED. | | | 21. CORRECTED. | | | 22. CORRECTED. | | | 23. NEW RISER PROVIDED SHOWS 4/0 ALUMINUM WIRE FROM | | | METER TO SERVICE DISCONNECT AND FROM SERVICE DISCONNECT | | | TO INTERIOR PANELS. THIS WIRE SIZE IS NOT RATED FOR 200 | | | AMPS. PROVIDE CORRECTION. NEC 310.15(B)(16); FBC RE | | | E3705.1 (NOT CORRECTED.) | | | 24. FEED TO INTERIOR PANELS FROM SERVICE DISCONNECT IS | | | REQUIRED TO HAVE AN EQUIPMENT GROUNDING CONDUCTOR, | | | SIZED PER CODE. PROVIDE CORRECTION. NEC 250.122; FBC RE | | | E3704.6, 3607.3.1 (ATTEMPTED CORRECTION IS NOT CODE | | | COMPLIANT.) | | | 25. SPECIFY WIRE AND CONDUIT SIZE FOR OVERHEAD MAST TO | | | FPL. WPB FBC 107.2.1; NEC 310.15(B)(7); FBC RE E3603.1 | | | (WIRE SIZE SPECIFIED IS NOT TO CODE.) | | | 26. GROUNDING ELECTRODE CONDUCTOR SHOULD NOT BE WIRED | | | TO METER CAN AND SERVICE DISCONNECT AND INTERIOR PANEL. | | | IT IS CONNECTED AT EITHER THE METER CAN OF THE FIRST | | | MEANS OF DISCONNECT. PROVIDE CORRECTION. NEC 250.6 (NOT | | | CORRECTED.) | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD | | | SHEETS?. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-10-11 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-10-11 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-10-11 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2018-10-11 09:54:43 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. AFCI PROTECTION SHOWN IN NOT CODE COMPLIANT. ALL | | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | | SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND | | | POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH | | | AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC | | | 210.8, 210.12; FBC RE E3902 (NOT CORRECTED. HAND | | | WRITTEN NOTES ARE NOT ACCEPTABLE. THE HAND WRITTEN NOTE | | | IS NOT CODE COMPLIANT.) | | | 2. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10; FBC RE E3603.3 (NOT PROVIDED, TO BE | | | PROVIDED PRIOR TO INSPECTION.) | | | 3. PROVIDE AIC RATING OF SERVICE DISCONNECT AND PANEL. | | | NEC 110.3, 110.9; FBC RE E3603.3 (NOT PROVIDED.) | | | 4. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | | FBC EC C405.1, R404.1 (NOT PROVIDED.) | | | 5. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | | 210.8(D); FBC RE E3902.10 (NOT PROVIDED.) | | | 6. CORRECTED. | | | 7. CORRECTED. | | | 8. A GROUNDING ELECTRODE SYSTEM IS REQUIRED TO BE | | | ESTABLISHED AT EACH SEPARATE BUILDING OR STRUCTURE AND | | | CONNECTED TOGETHER. PROVIDE DETAILS ON PLAN OF | | | GROUNDING ELECTRODE SYSTEM AND WIRING. NEC 250.32; FBC | | | RE E3607.3 (GROUNDING ELECTRODE CONDUCTOR SHOULD NOT BE | | | INSTALLED TO SUB-PANEL AT MAIN SERVICE. THE CONDUITS | | | FEEDING EACH OF THE SUB-PANELS AFTER THE FIRST MEANS OF | | | DISCONNECT SHOULD INCLUDE AN EQUIPMENT GROUNDING | | | CONDUCTOR SIZED PER NEC 250.122. PROVIDE CORRECTION.) | | | 9. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS. NEC 220; FBC RE E3602.2 (LOAD CALCULATION | | | PROVIDED DOES NOT INCLUDE ALL LOADS, DOES NOT INCLUDE | | | GARAGE PANEL, LOAD FOR TANKLESS HEATER NOT INCLUDED. | | | PROVIDE LOAD CALCULATION FOR ENTIRE SERVICE AS | | | REQUESTED. HAND WRITTEN CORRECTIONS ARE NOT | | | ACCEPTABLE.) | | | 10. CORRECTED. | | | 11. CORRECTED. | | | 12. NOT ON THIS PLAN. | | | 13. PROVIDE LOCATION OF METER CAN AND PANEL ON PLAN. | | | WPB FBC 107.2.1 (LOCATION OF METER AND SERVICE | | | DISCONNECTS NOT SHOWN.) | | | 14. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR | | | ALTERED CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE | | | CIRCUITS, AND AFCI OR GFCI PROTECTION WHERE APPLICABLE | | | TO COMPLY WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, | | | 215.5, 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 | | | (NOT PROVIDED.) | | | 15. ELECTRICAL PLAN IS REQUIRED TO BE SIGNED BY PERSON | | | RESPONSIBLE FOR THE DESIGN. PROVIDE CORRECTION. FS | | | 481.229; WPB FBC 107.2.1, 107.3.5.1.2 (NOT PROVIDED. | | | EACH SHEET SUPPLIED AS PART OF PLAN MUST BEAR THE | | | PRINTED NAME AND SIGNATURE OF THE PERSON RESPONSIBLE | | | FOR THE DESIGN. IF THAT PERSON IS LICENSED, IT MUST | | | ALSO INCLUDE THAT LICENSE NUMBER.) | | | 16. CORRECTED. | | | 17. CORRECTED. | | | 18. CORRECTED. | | | 19. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 (NOT | | | PROVIDED.) | | | 20. NOT ON THIS PLAN. | | | 21. A GFCI PROTECTED RECEPTACLE OUTLET ON A 20 AMP | | | CIRCUIT IS REQUIRED WITHIN 3 FEET OF EACH BASIN. | | | PROVIDE CORRECTION. NEC 210.11(C)(3), 210.52(D); FBC RE | | | E3703.4, E3901.6 (NOT CORRECTED.) | | | 22. GFCI PROTECTION IS REQUIRED FOR ALL RECEPTACLE | | | OUTLETS IN GARAGE. PROVIDE CORRECTION. NEC 210.8; FBC | | | RE E3902.2 (INCLUDES GARAGE DOOR OPENER, NOT | | | CORRECTED.) | | | 23. PROVIDE WEATHER PROOF GFCI PROTECTED RECEPTACLE | | | OUTLET FOR EACH BALCONY ACCESSIBLE FROM THE DWELLING | | | UNIT. NEC 210.52(E)(3); FBC RE E3901.7 (NOT PROVIDED.) | | | | | | NEW COMMENTS: | | | | | | 24. NEW RISER PROVIDED SHOWS 4/0 ALUMINUM WIRE FROM | | | METER TO SERVICE DISCONNECT AND FROM SERVICE DISCONNECT | | | TO INTERIOR PANELS. THIS WIRE SIZE IS NOT RATED FOR 200 | | | AMPS. PROVIDE CORRECTION. NEC 310.15(B)(16); FBC RE | | | E3705.1 | | | 25. FEED TO INTERIOR PANELS FROM SERVICE DISCONNECT IS | | | REQUIRED TO HAVE AN EQUIPMENT GROUNDING CONDUCTOR, | | | SIZED PER CODE. PROVIDE CORRECTION. NEC 250.122; FBC RE | | | E3704.6, 3607.3.1 | | | 26. SPECIFY WIRE AND CONDUIT SIZE FOR OVERHEAD MAST TO | | | FPL. WPB FBC 107.2.1; NEC 310.15(B)(7); FBC RE E3603.1 | | | 27. GROUNDING ELECTRODE CONDUCTOR SHOULD NOT BE WIRED | | | TO METER CAN AND SERVICE DISCONNECT AND INTERIOR PANEL. | | | IT IS CONNECTED AT EITHER THE METER CAN OF THE FIRST | | | MEANS OF DISCONNECT. PROVIDE CORRECTION. NEC 250.6 | | | | | | | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD | | | SHEETS?. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-08-28 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-08-28 |
Time |
17:26 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-08-28 |
Time |
17:26 |
Sent To |
|
|
| Notes |
| 2018-08-28 17:26:21 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. AFCI PROTECTION SHOWN IN NOT CODE COMPLIANT. ALL | | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | | SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND | | | POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH | | | AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC | | | 210.8, 210.12; FBC RE E3902 | | | 2. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10; FBC RE E3603.3 | | | 3. PROVIDE AIC RATING OF SERVICE DISCONNECT AND PANEL. | | | NEC 110.3, 110.9; FBC RE E3603.3 | | | 4. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | | FBC EC C405.1, R404.1 | | | 5. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | | 210.8(D); FBC RE E3902.10 | | | 6. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | | SERVICE. SHOW ON PLAN. NEC 250.94; FBC RE E3609.3 | | | 7. RISER DIAGRAM SHOWS A SINGLE GROUND ROD AS A | | | SUPPLEMENTAL GROUNDING ELECTRODE. THIS SUPPLEMENTAL | | | GROUNDING ELECTRODE NEEDS TO BE AUGMENTED BY AN | | | ADDITIONAL ELECTRODE AT LEAST 6 FEET AWAY OR PROVIDE | | | EVIDENCE OF RESISTANCE TO GROUND OF 25 OHMS OR LESS. | | | NEC 250.53(A)(2); FBC RE E3608.4 | | | 8. A GROUNDING ELECTRODE SYSTEM IS REQUIRED TO BE | | | ESTABLISHED AT EACH SEPARATE BUILDING OR STRUCTURE AND | | | CONNECTED TOGETHER. PROVIDE DETAILS ON PLAN OF | | | GROUNDING ELECTRODE SYSTEM AND WIRING. NEC 250.32; FBC | | | RE E3607.3 | | | 9. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS. NEC 220; FBC RE E3602.2 | | | 10. RECEPTACLES INSTALLED TO SERVE THE COUNTER TOP IN | | | KITCHEN REQUIRE GFCI PROTECTION. PROVIDE CORRECTION. | | | NEC 210.8; FBC RE E3902.6 | | | 11. RECEPTACLE OUTLETS INSTALLED IN LAUNDRY AREAS SHALL | | | HAVE GFCI PROTECTION. PROVIDE CORRECTION. NEC | | | 210.8(A)(9); FBC RE E3902.9 | | | 12. LIGHTING MUST MAINTAIN PROPER CLEARANCES FROM THE | | | NEAREST POINT OF STORAGE SPACE IN A CLOTHES CLOSET. | | | PROVIDE CORRECTION. NEC 410.16; FBC RE E4003.12 | | | 13. PROVIDE LOCATION OF METER CAN AND PANEL ON PLAN. | | | WPB FBC 107.2.1 | | | 14. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR | | | ALTERED CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE | | | CIRCUITS, AND AFCI OR GFCI PROTECTION WHERE APPLICABLE | | | TO COMPLY WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, | | | 215.5, 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 | | | 15. ELECTRICAL PLAN IS REQUIRED TO BE SIGNED BY PERSON | | | RESPONSIBLE FOR THE DESIGN. PROVIDE CORRECTION. FS | | | 481.229; WPB FBC 107.2.1, 107.3.5.1.2 | | | 16. ONLY ONE SERVICE PER RESIDENTIAL ADDRESS IS | | | PERMITTED. PROVIDE CORRECTION. WPB FBC 107.2.1; NEC | | | 230.2; FBC RE E3601.2 | | | 17. A BUILDING OR OTHER STRUCTURE THAT IS SERVED BY A | | | BRANCH CIRCUIT OR FEEDER ON THE LOAD SIDE OF A SERVICE | | | DISCONNECTING MEANS SHALL BE SUPPLIED BY ONLY ONE | | | FEEDER OR BRANCH CIRCUIT. NEC 225.30 | | | 18. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | | STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR | | | MAIN BREAKER AT THE PANEL FOR PANEL A. NEC 225.31, | | | 225.32 | | | 19. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 | | | 20. PLAN SHOWS ONE SMALL APPLIANCE CIRCUIT FOR KITCHEN | | | RECEPTACLE OUTLETS. A MINIMUM OF TWO 20 AMPERE BRANCH | | | CIRCUIT SHALL BE PROVIDED TO SUPPLY KITCHEN COUNTERTOP | | | RECEPTACLE OUTLET(S). PROVIDE CORRECTION. NEC | | | 210.11(C)(1) , FBC RE E3703.2 | | | 21. A GFCI PROTECTED RECEPTACLE OUTLET ON A 20 AMP | | | CIRCUIT IS REQUIRED WITHIN 3 FEET OF EACH BASIN. | | | PROVIDE CORRECTION. NEC 210.11(C)(3), 210.52(D); FBC RE | | | E3703.4, E3901.6 | | | 22. GFCI PROTECTION IS REQUIRED FOR ALL RECEPTACLE | | | OUTLETS IN GARAGE. PROVIDE CORRECTION. NEC 210.8; FBC | | | RE E3902.2 | | | 23. PROVIDE WEATHER PROOF GFCI PROTECTED RECEPTACLE | | | OUTLET FOR EACH BALCONY ACCESSIBLE FROM THE DWELLING | | | UNIT. NEC 210.52(E)(3); FBC RE E3901.7 | | | | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD | | | SHEETS?. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-10-29 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-10-29 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-10-29 |
Time |
16:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-08-24 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-08-24 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-08-24 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2018-08-24 16:14:10 | REQUIRES HPB APPROVAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-11-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-11-14 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2018-11-15 15:24:00 | RESUB ROUTED TO JPEARSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-11-14 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-11-14 |
Time |
06:34 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-11-14 |
Time |
06:34 |
Sent To |
|
|
| Notes |
| 2018-11-06 12:58:59 | R32 | | | **TRAVELLING WITH 18070946** |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-11-01 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-11-01 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-10-04 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2018-10-05 15:31:08 | LIBRARY | | | **TRAVELLING WITH 18070946** |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-09-25 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-09-25 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-08-06 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2018-09-25 13:40:50 | SEE REVIEW ON 18070496 | | 2018-09-14 08:03:30 | STILL NEED MECH AND PLUMB | | 2018-08-07 15:08:51 | R30 | | | **TRAVELLING WITH 18070946** |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2018-11-21 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-11-21 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-11-21 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2018-11-21 15:55:05 | MU-2018-039114-0000 | | | PAID ON 11/20/18 | | | STAMP ON PLANS-OK |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2018-11-01 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-11-01 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-11-01 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2018-11-01 09:46:38 | UPON APPROVAL OF ZONING, PLUMBING AND ELECTRICAL PLEASE | | | CHACK OUT ONE COPY TO TAKE TO COUNTY. | | | | | | [FBC AMENDED 109]PLANS REQUIRE REVIEW BY THE PBC IMPACT | | | FEE OFFICE. CALL (561) 233-5025. UPON APPROVAL, YOU MAY | | | CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR | | | REVIEW. PLEASE RETURNED STAMPED AND WITH A COPY OF THE | | | RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE | | | OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO | | | V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN | | | AIRE.PDF | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2018-09-14 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-09-14 |
Time |
08:07 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-09-14 |
Time |
08:07 |
Sent To |
|
|
| Notes |
| 2018-09-14 08:07:09 | [FBC AMENDED 109]PLANS REQUIRE REVIEW BY THE PBC IMPACT | | | FEE OFFICE. CALL (561) 233-5025. UPON APPROVAL, YOU MAY | | | CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR | | | REVIEW. PLEASE RETURNED STAMPED AND WITH A COPY OF THE | | | RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE | | | OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO | | | V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN | | | AIRE.PDF |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2018-11-14 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-11-14 |
Time |
06:29 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-11-14 |
Time |
06:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2018-10-31 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-10-31 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-10-31 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2018-10-31 14:57:37 | NO PLANS |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2018-09-25 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-09-25 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-09-25 |
Time |
13:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-11-13 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-11-13 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-11-13 |
Time |
16:42 |
Sent To |
|
|
| Notes |
| 2018-11-13 16:43:32 | 11/13/18 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVE PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-10-30 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2018-10-30 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-10-30 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2018-10-30 11:42:16 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 2ND REVIEW: | | | PLUMBING COMMENTS: DENIED | | | | | | 1. PLAN SHEET 2 OF 7 SHOWS A 30? WIDE SPACE BETWEEN THE | | | TWO WALLS AT THE WATER CLOSET, BUT TWO OTHER DIMENSIONS | | | BETWEEN THE TWO WALLS SHOW A 2?-8? SPACE. PLEASE | | | CLARIFY IN ACCORDANCE WITH WPB FBC 107.2.1. | | | 2. PROVIDE DIMENSIONS ON PLAN SHEET 2 OF 7 FOR THE | | | FOLLOWING AS REQUIRED BY WPB FBC 107.2.1. SECOND | | | REQUEST | | | A. SHOW THE SHOWER COMPARTMENT ACCESS AND EGRESS | | | OPENING SHALL HAVE A CLEAR AND UNOBSTRUCTED FINISHED | | | WIDTH OF NOT LESS THAN 22 INCHES PER FBC RES P2708.1.1 | | | B. PLEASE NOTE ON THE PLAN WHAT TYPE OF COVERING OVER | | | THE SHOWER OPENING A DOOR OR SHOWER CURTAIN IT SHALL | | | COMPLY WITH FBC RES P2705.1(4)(5); NOTE THAT A SHOWER | | | DOOR MUST OPEN OUTWARD PER P2708.1 AND MUST BE | | | CONSIDERED WHEN PROVIDING CLEARANCE | | | C. SHOW A CLEARANCE OF NOT LESS THAN 21 INCHES IN FRONT | | | OF A WATER CLOSET OR LAVATORY TO ANY WALL, FIXTURE OR | | | DOOR PER FBC RES P2705.1, (4) (5). IT MAY BE NECESSARY | | | TO PROVIDE A CUT SHEET FOR LAVATORY SHOWING PHYSICAL | | | DIMENSIONS AND THAT IT WILL FIT IN THE SPACE WHILE | | | PROVIDING THE REQUIRED CLEARANCES. | | | | | | | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | (STAMPED/SEALED AND SIGNED BY DESIGNER OF RECORD IN | | | ACCORDANCE WITH FS 471, 481 & FAC 61G15) INTO THE | | | ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED | | | SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS | | | SHOULD REMAIN IN PACKAGE AND BE MARKED "VOID". | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-09-14 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-09-14 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-09-14 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2018-09-14 12:29:36 | 1ST REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE LAVATORY OVER THE TOILET IS PROHIBITED THE | | | FIXTURE SHALL BE MOUNTED ADJACENT TO EACH OTHER. PER | | | FBC RES P2705.1(4)(5) | | | | | | 2. THE WASHING MACHINE ON GROUND FLOOR IS NOT VENTED | | | PROPERLY IT CANNOT CONNECT TO SOIL STACK WITHOUT | | | SEPARATE VENT IT SHALL COMPLY WITH ONE OF THE VENTING | | | SYSTEMS SHOWN IN FBC RES CH 31 PER FBC RES P3101.2.1 | | | | | | 3. THE WASHING MACHINE STAND PIPE, P-TRAP AND FIXTURE | | | DRAIN SHALL BE A MIN OF 2" PER FBC RES P2601.1 AND FBC | | | PL SAC 406.2 AND TABLE 709.1 | | | | | | 4. PROVIDE MANUFACTURE SPECIFICATIONS AND SIZING | | | CALCULATIONS FOR THE ELECTRIC TANKLESS HEATER. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | 5. PLEASE PROVIDE ALL DIMENSIONS FOR BATHROOM INCLUDING | | | BETWEEN THE FRONT OF THE TOILET AND THE SHOWERR TO | | | COMPLY WITH FBC RES P2705.1(4)(5) | | | | | | 6. PLEASE NOTE ON THE PLAN WHAT TYPE OF COVERING OVER | | | THE SHOWE OPENING A DOOR OR SHOWER CURTAIN IT SHALL | | | COMPLY WITH FBC RES P2705.1(4)(5) | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2018-11-01 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-11-01 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-11-01 |
Time |
09:47 |
Sent To |
|
|
| Notes |
| 2018-11-01 09:48:26 | PRODUCT APPROVALS APPROVED | | | 5V METAL ROOF |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2018-11-13 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-11-13 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-11-13 |
Time |
15:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2018-10-29 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-10-29 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-10-29 |
Time |
16:31 |
Sent To |
|
|
| Notes |
| 2018-10-29 16:45:23 | REQUIRES SEPARATE LANDSCAPE PERMIT AND MASTER PERMIT | | | SHALL INCLUDE SITE PLAN (SURVEY PROVIDED INDICATES 2 | | | STORY MAIN HOUSE). |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-08-24 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-08-24 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-08-24 |
Time |
16:14 |
Sent To |
|
|
| Notes |
| 2018-08-24 16:14:40 | REQUIRES HPB APPROVAL |
|
|