Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-09-05 Cont ID  
Sent By cthroop Date 2018-09-05 Time 07:33 Rev Time 0.00
Received By cthroop Date 2018-09-05 Time 07:33 Sent To I
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-08-16 Cont ID  
Sent By cthroop Date 2018-08-16 Time 14:56 Rev Time 0.00
Received By cthroop Date 2018-08-16 Time 14:55 Sent To E
Notes
2018-08-16 14:57:09BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE DESIGN WIND LOADS FOR PROPOSED SIGN.
  
 FBC 107.3.5.1.1(8) ? PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-CHAPTER 16
  
 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED,
 VASD, AS DETERMINED IN ACCORDANCE WITH SECTION
 1609.3.1.
 2. RISK CATEGORY.
 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED.
 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY
 DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL
 RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/
 M2).
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2018-10-23 Cont ID  
Sent By fgiaquin Date 2018-10-23 Time 08:19 Rev Time 0.00
Received By fgiaquin Date 2018-10-23 Time 08:18 Sent To I
Notes
2018-10-23 08:19:20REQUIRED ELECTRICAL WORK SPECIFIED IN PREVIOUS PLAN
 REVIEW COMMENTS BEING PERFORMED BY DAVCO ELECTRIC
 PERMIT # 18100603

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2018-09-04 Cont ID  
Sent By jleahy Date 2018-09-04 Time 12:12 Rev Time 0.00
Received By jleahy Date 2018-09-04 Time 12:12 Sent To B
Notes
2018-09-04 12:13:25SEE COMMENT FROM FIRST PLAN REVIEW JLEAHY

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-08-22 Cont ID  
Sent By fgiaquin Date 2018-08-22 Time 07:07 Rev Time 0.00
Received By fgiaquin Date 2018-08-22 Time 06:53 Sent To I
Notes
2018-08-22 06:54:18ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE AN ELECTRICAL PLAN FOR SIGN, AND SHOW
 LOCATION OF SIGNS ON BUILDING, NOT A PLAN THAT SAYS
 "L.E.D." FBC 107.2.1-NOT ENOUGH INFORMATION.
  
 2. NO DISCONNECT WITHIN SIGHT OF SIGN TO DISCONNECT ALL
 UNGROUNDED CONDUCTORS OF BRANCH CIRCUIT/FEEDER AT POINT
 WHICH CONDUCTORS ENTER SIGN AS PER 600.6A1 NEC 2014.
  
 3. ELECTRICAL SUB-PERMIT MUST BE PULLED BY LICENSED
 ELECTRICIAN, (EC) OR (ER) REGISTERED TO PALM BEACH
 COUNTY, BECAUSE NEW DISCONNECT REQUIREMENTS OF 600.6A1
 NEC AND INSTALLATION OF ASTRONOMICAL TIME CLOCK (FBC CE
 405.2.4) ARE OUT OF SCOPE FOR ES LICENSE. PLEASE SEE
 SCOPE OF AN ES LICENSE BELOW:
  
 SIGN CONTRACTORS F.S. 489.505 (#19) AND F.A.C.
 61G6-7.001 SPECIALTY ELECTRICAL CONTRACTORS (#2 SIGN
 SPECIALTY CONTRACTOR)
  
 THE SCOPE OF CERTIFICATION INCLUDES THE STRUCTURAL
 FABRICATION INCLUDING CONCRETE FOUNDATION, ERECTION,
 INSTALLATION, ALTERATION, REPAIR, SERVICE AND WIRING OF
 ELECTRICAL SIGNS AND OUTLINE LIGHTING. THE SCOPE OF
 CERTIFICATION SHALL NOT INCLUDE THE PROVISION OF, OR
 ANY ELECTRICAL WORK BEYOND, THE LAST DISCONNECT MEAN OR
 TERMINAL POINTS. HOWEVER, A CONTRACTOR CERTIFIED UNDER
 THIS SECTION MAY PROVIDE THE ELECTRICAL ENTRANCE
 REQUIREMENTS FOR METERING AND MAIN DISCONNECT OF REMOTE
 BILLBOARDS OR SIGNS WHICH ARE INDEPENDENT OF ANY
 STRUCTURE OR BUILDING AND WHICH REQUIRE NO MORE THAN
 TWENTY-FIVE (25) KILOWATTS AT TWO HUNDRED FIFTY (250)
 VOLTS MAXIMUM.
  
  
 HAVE QUALIFIER CALL ME IF THERE ARE ANY QUESTIONS
 PLEASE. CELL PHONE IS BEST AS I AM NORMALLY IN THE
 FIELD PERFORMING INSPECTIONS.
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2017 6TH ED.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WPB
 [email protected]
 CELL: 561-657-1653
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-10-23 Cont ID  
Sent By fgiaquin Date 2018-10-23 Time 08:19 Rev Time 0.00
Received By fgiaquin Date   Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-09-05 Cont ID  
Sent By cthroop Date 2018-09-05 Time 07:33 Rev Time 0.00
Received By cthroop Date 2018-08-27 Time 12:47 Sent To  
Notes
2018-08-29 12:47:42RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-08-22 Cont ID  
Sent By fgiaquin Date 2018-08-22 Time 07:07 Rev Time 0.00
Received By fgiaquin Date 2018-08-03 Time 14:40 Sent To Z
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2018-08-30 Cont ID  
Sent By elevesqu Date 2018-08-30 Time 16:27 Rev Time 0.00
Received By elevesqu Date 2018-08-30 Time 16:27 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2018-08-15 Cont ID  
Sent By fgiaquin Date 2018-08-22 Time 07:07 Rev Time 0.00
Received By elevesqu Date 2018-08-15 Time 13:12 Sent To B
Notes
2018-08-15 13:13:22PER RESOLUTION 132-17, TWO BUILDING IDENTITY SIGNS
 PERMITTED WITH SAME IDENTIY ABOVE 5TH FLOOR.
  
 MAY NOT EXCEED 200 SF. PER SECTION 94-405, OCMPUTATION
 INCLUDES ALL CONTENT, BACKGROUND AND STRUCTURAL
 ELEMENTS OF SIGN. SIGN EXCEEDS 200 SF WITH BACK PANEL.
 PLEASE REVISE.
  
 CALL LIZ LEVESQUE, URBAN DESIGN PLANNER WITH ANY
 QUESTIONS 561 822 1426. EMAIL IS BEST WAY OF
 CONTACTING,[email protected]


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved