 |
Plan Review Details - Permit 18080202
| Plan Review Stops For Permit 18080202 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-10-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-10-19 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-10-19 |
Time |
10:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-09-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-09-05 |
Time |
07:37 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-09-05 |
Time |
07:34 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-08-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-08-16 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-08-16 |
Time |
14:35 |
Sent To |
E |
|
| Notes |
| 2018-08-16 14:53:34 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE DESIGN WIND LOADS FOR PROPOSED SIGN. | | | | | | FBC 107.3.5.1.1(8) ? PROVIDE WIND DESIGN LOADS/DESIGN | | | PRESSURES PURSUANT TO FBC-CHAPTER 16 | | | | | | 1603.1.4 WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | | STRUCTURE: | | | 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | | MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED, | | | VASD, AS DETERMINED IN ACCORDANCE WITH SECTION | | | 1609.3.1. | | | 2. RISK CATEGORY. | | | 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | | THAN ONE WIND EXPOSURE IS UTILIZED. | | | 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | | 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | | COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY | | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL | | | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/ | | | M2). | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2018-10-23 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-10-23 |
Time |
08:23 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-10-23 |
Time |
08:23 |
Sent To |
I |
|
| Notes |
| 2018-10-23 08:23:08 | REQUIRED ELECTRICAL WORK SPECIFIED IN PREVIOUS PLAN | | | REVIEW COMMENTS BEING PERFORMED BY DAVCO ELECTRIC | | | PERMIT # 18100603 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2018-10-18 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-10-18 |
Time |
06:42 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-10-18 |
Time |
06:22 |
Sent To |
B |
|
| Notes |
| 2018-10-18 06:42:16 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. SEE PREVIOUS PLAN REVIEW COMMENTS. IF NEXT PLAN | | | REVIEW FAILS FOR THE SAME VIOLATIONS AS PREVIOUS PLAN | | | REVIEW COMMENTS A 4X PERMIT FEE WILL BE ASSESSED TO THE | | | PERMIT APPLICATION. PLEASE CALL MY CELL PHONE DIRECTLY | | | WITH ANY QUESTIONS AT 561-657-1653 | | | | | | FLORIDA STATUTE 553.80(2)(B) DESIGN OF PROFESSIONAL | | | DOCUMENTS | | | | | | WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONAL?S | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRE BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED TO PURSUANT TO CHAPTER 120, THE | | | LOCAL GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE | | | THIRD SUCH REVIEW THE PLANS ARE REJECTED FOR THAT CODE | | | VIOLATION A FEE OF FOUR TIMES THE AMOUNT OF THE PORTION | | | OF PERMIT FEE ATTRIBUTED TO PLAN REVIEW. | | | | | | PLAN REVIEW FEES IN THE CITY OF WEST PALM BEACH ARE 30% | | | OF THE PROJECTS PERMIT FEE WITH A MINIMUM PLAN REVIEW | | | FEE OF $50. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO III | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WPB | | | [email protected] | | | CELL: 561-657-1653 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-09-04 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-09-04 |
Time |
12:11 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-09-04 |
Time |
12:10 |
Sent To |
B |
|
| Notes |
| 2018-09-04 12:11:06 | SEE ORIGINAL COMMENTS ON FIRST REVIEW JLEAHY |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-08-22 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-08-22 |
Time |
06:33 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-08-22 |
Time |
06:24 |
Sent To |
I |
|
| Notes |
| 2018-08-22 06:33:02 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE AN ELECTRICAL PLAN FOR SIGN, AND SHOW | | | LOCATION OF SIGNS ON BUILDING, NOT A PLAN THAT SAYS | | | "L.E.D." FBC 107.2.1-NOT ENOUGH INFORMATION. | | | | | | 2. NO DISCONNECT WITHIN SIGHT OF SIGN TO DISCONNECT ALL | | | UNGROUNDED CONDUCTORS OF BRANCH CIRCUIT AT POINT WHICH | | | CONDUCTORS ENTER SIGN AS PER 600.6A1 NEC 2014. | | | | | | 3. ELECTRICA SUB-PERMIT MUST BE PULLED BY LICENSED | | | ELECTRICIAN, (EC) OR (ER) REGISTERED TO PALM BEACH | | | COUNTY, BECAUSE NEW DISCONNECT REQUIREMENTS OF 600.6A1 | | | NEC AND INSTALLATION OF ASTRONOMICAL TIME CLOCK (FBC CE | | | 405.2.4) ARE OUT OF SCOPE FOR ES LICENSE. PLEASE SEE | | | SCOPE OF AN ES LICENSE BELOW: | | | | | | SIGN CONTRACTORS F.S. 489.505 (#19) AND F.A.C. | | | 61G6-7.001 SPECIALTY ELECTRICAL CONTRACTORS (#2 SIGN | | | SPECIALTY CONTRACTOR) | | | | | | THE SCOPE OF CERTIFICATION INCLUDES THE STRUCTURAL | | | FABRICATION INCLUDING CONCRETE FOUNDATION, ERECTION, | | | INSTALLATION, ALTERATION, REPAIR, SERVICE AND WIRING OF | | | ELECTRICAL SIGNS AND OUTLINE LIGHTING. THE SCOPE OF | | | CERTIFICATION SHALL NOT INCLUDE THE PROVISION OF, OR | | | ANY ELECTRICAL WORK BEYOND, THE LAST DISCONNECT MEAN OR | | | TERMINAL POINTS. HOWEVER, A CONTRACTOR CERTIFIED UNDER | | | THIS SECTION MAY PROVIDE THE ELECTRICAL ENTRANCE | | | REQUIREMENTS FOR METERING AND MAIN DISCONNECT OF REMOTE | | | BILLBOARDS OR SIGNS WHICH ARE INDEPENDENT OF ANY | | | STRUCTURE OR BUILDING AND WHICH REQUIRE NO MORE THAN | | | TWENTY-FIVE (25) KILOWATTS AT TWO HUNDRED FIFTY (250) | | | VOLTS MAXIMUM. | | | | | | | | | HAVE QUALIFIER CALL ME IF THERE ARE ANY QUESTIONS | | | PLEASE. CELL PHONE IS BEST AS I AM NORMALLY IN THE | | | FIELD PERFORMING INSPECTIONS. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WPB | | | [email protected] | | | CELL: 561-657-1653 | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2018-10-23 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-10-23 |
Time |
08:23 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-10-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-10-19 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-10-12 |
Time |
12:32 |
Sent To |
|
|
| Notes |
| 2018-10-15 12:33:06 | RESUB ROUTED TO JLEAHY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-09-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-09-05 |
Time |
07:38 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-08-27 |
Time |
12:46 |
Sent To |
|
|
| Notes |
| 2018-08-29 12:46:38 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-08-22 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-08-22 |
Time |
06:33 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-08-03 |
Time |
14:41 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-08-30 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
2018-08-30 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2018-08-30 |
Time |
16:27 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-08-15 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-08-22 |
Time |
06:33 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2018-08-08 |
Time |
11:43 |
Sent To |
B |
|
| Notes |
| 2018-08-15 13:12:20 | PER RESOLUTION 132-17, TWO BUILDING IDENTITY SIGNS | | | PERMITTED WITH SAME IDENTIY ABOVE 5TH FLOOR. | | | | | | MAY NOT EXCEED 200 SF. PER SECTION 94-405, OCMPUTATION | | | INCLUDES ALL CONTENT, BACKGROUND AND STRUCTURAL | | | ELEMENTS OF SIGN. SIGN EXCEEDS 200 SF WITH BACK PANEL. | | | PLEASE REVISE. | | | | | | PLEASE PROVIDE IMAGE OF FULL BUILDING WITH SIGN | | | PLACEMENT. | | | | | | CALL LIZ LEVESQUE, URBAN DESIGN PLANNER WITH ANY | | | QUESTIONS 561 822 1426. EMAIL IS BEST WAY OF | | | CONTACTING,[email protected] |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |