Plan Review Details - Permit 18080198
| Plan Review Stops For Permit 18080198 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-11-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-11-07 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-11-07 |
Time |
14:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-08-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-08-17 |
Time |
07:38 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-08-17 |
Time |
07:36 |
Sent To |
E |
|
| Notes |
| 2018-08-17 07:42:10 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE DESIGN WIND LOADS FOR PROPOSED SIGN. | | | FBC 107.3.5.1.1(8) ? PROVIDE WIND DESIGN LOADS/DESIGN | | | PRESSURES PURSUANT TO FBC-CHAPTER 16 | | | | | | 1603.1.4 WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | | STRUCTURE: | | | 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | | MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED, | | | VASD, AS DETERMINED IN ACCORDANCE WITH SECTION | | | 1609.3.1. | | | 2. RISK CATEGORY. | | | 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | | THAN ONE WIND EXPOSURE IS UTILIZED. | | | 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | | 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | | COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY | | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL | | | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/ | | | M2). | | | | | | 2. PROVIDE FASTNER SCHEDULE WITH WALL TYPE. | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE | | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED AND MARK VOID. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-11-28 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-11-28 |
Time |
05:55 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-11-28 |
Time |
05:34 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-11-07 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-11-07 |
Time |
06:50 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-11-07 |
Time |
06:15 |
Sent To |
|
|
| Notes |
| 2018-11-07 06:50:07 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. SEAL BY ENGINEER UNREADABLE AND IS NOT VALID. PHOTO | | | COPIES OF SEALS ARE NOT ACCEPTABLE. PLEASE SEE | | | REQUIREMENTS FOR SEALS BELOW: | | | | | | PHYSICALLY TRANSMITTED DOCUMENTS REQUIRE THAT THE | | | LICENSEE CREATE BY HAND AN ORIGINAL OF THE LICENSEE'S | | | SIGNATURE. A SCANNED, FACSIMILE, DIGITALLY CREATED OR | | | COPIED IMAGE OF THE LICENSEE'S SIGNATURE IS NOT ALLOWED | | | ON PHYSICALLY TRANSMITTED DOCUMENTS. | | | CHAPTER 61G15-23.003(1), F.A.C., THE LICENSEE SHALL | | | SIGN BY HAND AN ORIGINAL OF THE LICENSEE'S SIGNATURE ON | | | EACH PAGE REQUIRED TO BE SEALED. A SCANNED, FACSIMILE, | | | DIGITALLY CREATED OR COPIED IMAGE OF THE LICENSEE'S | | | SIGNATURE SHALL NOT BE USED. | | | | | | AS FOR CREATING THE SEAL, PHYSICALLY TRANSMITTED | | | DOCUMENTS ARE ALLOWED TO BE EMBOSSED, SEALED USING A | | | WET STAMP, OR CONTAIN A DIGITALLY CREATED SEAL (AS PART | | | OF THE BORDER). IN EACH OF THESE CASES THE SEAL IS TO | | | PARTIALLY OVERLAP THE LICENSEE'S SIGNATURE SUCH THAT | | | THE SIGNATURE IS NOT MADE ILLEGIBLE. | | | CHAPTER 61G15-23.003(2), F.A.C., THE LICENSEE MUST THEN | | | USE A WET SEAL, A DIGITALLY CREATED SEAL, OR AN | | | EMBOSSING SEAL PLACED PARTIALLY OVERLAPPING THE | | | LICENSEE'S SIGNATURE ON EACH PAGE REQUIRED TO BE | | | SEALED. THE PLACEMENT OF THE SEAL SHALL NOT RENDER THE | | | SIGNATURE ILLEGIBLE. | | | | | | 2. LICENSED ELECTRICIAN NEEDED TO PULL ELEC PERMIT FOR | | | SIGN FOR REQUIRED ELECTRICAL WORK. MUST BE EC OR ER | | | REGISTERED IN PALM BEACH COUNTY. NEW DISCONNECT | | | REQUIRED BY 600.6A1 NEC AND BRANCH CIRCUIT REQUIRED BY | | | 600.5 NEC OUT OF SCOPE OF WORK FOR ES LICENSE. PLEASE | | | SEE SCOPE OF ES LICENSE BELOW: | | | | | | SIGN CONTRACTORS F.S. 489.505 (#19) AND F.A.C. | | | 61G6-7.001 SPECIALTY ELECTRICAL CONTRACTORS (#2 SIGN | | | SPECIALTY CONTRACTOR) | | | | | | THE SCOPE OF CERTIFICATION INCLUDES THE STRUCTURAL | | | FABRICATION INCLUDING CONCRETE FOUNDATION, ERECTION, | | | INSTALLATION, ALTERATION, REPAIR, SERVICE AND WIRING OF | | | ELECTRICAL SIGNS AND OUTLINE LIGHTING. THE SCOPE OF | | | CERTIFICATION SHALL NOT INCLUDE THE PROVISION OF, OR | | | ANY ELECTRICAL WORK BEYOND, THE LAST DISCONNECT MEAN OR | | | TERMINAL POINTS. HOWEVER, A CONTRACTOR CERTIFIED UNDER | | | THIS SECTION MAY PROVIDE THE ELECTRICAL ENTRANCE | | | REQUIREMENTS FOR METERING AND MAIN DISCONNECT OF REMOTE | | | BILLBOARDS OR SIGNS WHICH ARE INDEPENDENT OF ANY | | | STRUCTURE OR BUILDING AND WHICH REQUIRE NO MORE THAN | | | TWENTY-FIVE (25) KILOWATTS AT TWO HUNDRED FIFTY (250) | | | VOLTS MAXIMUM. | | | | | | PROVIDE LETTER WHEN RESUBMITTING WITH PERMIT # OF | | | PERMIT FOR ADDITIONAL ELECTRICAL WORK REQUIRED FOR SIGN | | | INSTALLATION BY LICENSED ELECTRICIAN. | | | | | | HAVE QUALIFIER CALL ME IF THERE ARE ANY QUESTIONS. | | | CONTACT INFORMATION IS BELOW. CELL PHONE IS BEST. | | | | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO III | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WPB | | | [email protected] | | | CELL: 561-657-1653 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-08-22 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-08-22 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-08-22 |
Time |
16:55 |
Sent To |
B |
|
| Notes |
| 2018-08-22 16:56:01 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SHOWING | | | DISCONNECT REQUIRED BY 600.6A1 AND ALL OTHER ELECTRICAL | | | ASSOCIATED WITH INSTALLATION OF THE SIGN, SIGNED AND | | | SEALED BY A LICENSED DESIGN PROFESSIONAL OR THE | | | ELECTRICAL CONTRACTOR QUALIFIER. FS 471.003(2)(H); | | | 471.025; WPB FBC 107.2.1, 107.3.5 | | | | | | 2. SEAL BY ENGINEER UNREADABLE AND IS NOT VALID. PHOTO | | | COPIES OF SEALS ARE NOT ACCEPTABLE. PLEASE SEE | | | REQUIREMENTS FOR SEALS BELOW: | | | | | | PHYSICALLY TRANSMITTED DOCUMENTS REQUIRE THAT THE | | | LICENSEE CREATE BY HAND AN ORIGINAL OF THE LICENSEE'S | | | SIGNATURE. A SCANNED, FACSIMILE, DIGITALLY CREATED OR | | | COPIED IMAGE OF THE LICENSEE'S SIGNATURE IS NOT ALLOWED | | | ON PHYSICALLY TRANSMITTED DOCUMENTS. | | | CHAPTER 61G15-23.003(1), F.A.C., THE LICENSEE SHALL | | | SIGN BY HAND AN ORIGINAL OF THE LICENSEE'S SIGNATURE ON | | | EACH PAGE REQUIRED TO BE SEALED. A SCANNED, FACSIMILE, | | | DIGITALLY CREATED OR COPIED IMAGE OF THE LICENSEE'S | | | SIGNATURE SHALL NOT BE USED. | | | | | | AS FOR CREATING THE SEAL, PHYSICALLY TRANSMITTED | | | DOCUMENTS ARE ALLOWED TO BE EMBOSSED, SEALED USING A | | | WET STAMP, OR CONTAIN A DIGITALLY CREATED SEAL (AS PART | | | OF THE BORDER). IN EACH OF THESE CASES THE SEAL IS TO | | | PARTIALLY OVERLAP THE LICENSEE'S SIGNATURE SUCH THAT | | | THE SIGNATURE IS NOT MADE ILLEGIBLE. | | | CHAPTER 61G15-23.003(2), F.A.C., THE LICENSEE MUST THEN | | | USE A WET SEAL, A DIGITALLY CREATED SEAL, OR AN | | | EMBOSSING SEAL PLACED PARTIALLY OVERLAPPING THE | | | LICENSEE'S SIGNATURE ON EACH PAGE REQUIRED TO BE | | | SEALED. THE PLACEMENT OF THE SEAL SHALL NOT RENDER THE | | | SIGNATURE ILLEGIBLE. | | | | | | 3. LICENSED ELECTRICIAN NEEDED TO PULL SUB-ELEC PERMIT | | | FOR SIGN, CANNOT ISSUE TO ES LICENSE. MUST BE EC OR ER | | | REGISTERED IN PALM BEACH COUNTY. NEW DISCONNECT | | | REQUIRED BY 600.6A1 AND TIMECLOCK REQUIRED BY FBC CE | | | 405.2.4 ARE OUT OF SCOPE OF WORK FOR ES LICENSE. PLEASE | | | SEE SCOPE OF ES LICENSE BELOW: | | | | | | SIGN CONTRACTORS F.S. 489.505 (#19) AND F.A.C. | | | 61G6-7.001 SPECIALTY ELECTRICAL CONTRACTORS (#2 SIGN | | | SPECIALTY CONTRACTOR) | | | | | | THE SCOPE OF CERTIFICATION INCLUDES THE STRUCTURAL | | | FABRICATION INCLUDING CONCRETE FOUNDATION, ERECTION, | | | INSTALLATION, ALTERATION, REPAIR, SERVICE AND WIRING OF | | | ELECTRICAL SIGNS AND OUTLINE LIGHTING. THE SCOPE OF | | | CERTIFICATION SHALL NOT INCLUDE THE PROVISION OF, OR | | | ANY ELECTRICAL WORK BEYOND, THE LAST DISCONNECT MEAN OR | | | TERMINAL POINTS. HOWEVER, A CONTRACTOR CERTIFIED UNDER | | | THIS SECTION MAY PROVIDE THE ELECTRICAL ENTRANCE | | | REQUIREMENTS FOR METERING AND MAIN DISCONNECT OF REMOTE | | | BILLBOARDS OR SIGNS WHICH ARE INDEPENDENT OF ANY | | | STRUCTURE OR BUILDING AND WHICH REQUIRE NO MORE THAN | | | TWENTY-FIVE (25) KILOWATTS AT TWO HUNDRED FIFTY (250) | | | VOLTS MAXIMUM. | | | | | | | | | HAVE QUALIFIER CALL ME IF THERE ARE ANY QUESTIONS. | | | CONTACT INFORMATION IS BELOW. CELL PHONE IS BEST. | | | | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WPB | | | [email protected] | | | CELL: 561-657-1653 | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-11-28 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-11-28 |
Time |
05:55 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-11-13 |
Time |
12:51 |
Sent To |
|
|
| Notes |
| 2018-11-14 12:51:19 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-11-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-11-07 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-10-25 |
Time |
12:42 |
Sent To |
|
|
| Notes |
| 2018-10-26 12:42:29 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-08-22 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-08-22 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-08-03 |
Time |
14:42 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2018-11-29 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-11-29 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-11-29 |
Time |
10:11 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2018-11-27 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-11-27 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-11-19 |
Time |
15:10 |
Sent To |
E |
|
| Notes |
| 2018-11-27 13:26:14 | ZONING REVIEW FAILED, DUE TO THE FOLLOWING: | | | | | | 1) REPEAT COMMENT - AS THE ALLOWABLE SQUARE FOOTAGE OF | | | THE SIGN IS BASED ON THE SQUARE FOOTAGE OF THE BUILDING | | | FACADE, PLEASE INDICATE THE HEIGHT AND WIDTH OF THE | | | FACADE ON WHICH THE SIGN IS TO BE MOUNTED. IF LEASING A | | | SPACE, PROVIDE HEIGHT AND WIDTH OF LEASED SPACE. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ | | | ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: 561-822-1442 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2018-11-05 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-11-05 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-11-05 |
Time |
15:42 |
Sent To |
E |
|
| Notes |
| 2018-11-05 15:42:55 | ZONING REVIEW FAILED, DUE TO THE FOLLOWING: | | | | | | 1) 3 EXISTING SIGNS AND 2 PROPOSED NEW WALL SIGNS UNDER | | | TWO DIFFERENT PERMIT NUMBERS THAT ARE LISTED IN THE | | | SUBJECT. ONLY 1 SIGN IS PERMITTED FOR NEW BUSINESS. THE | | | CODE ALLOWS 1 SIGN PER BUSINESS PLUS 2 ADDITIONAL SIGNS | | | PER BUILDING. SO IF 1 BUSINESS HAS THREE SIGNS ALREADY | | | THEN A NEW BUSINESS IS ONLY ALLOWED 1 SIGN MAXIMUM. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ | | | ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: 561-822-1442 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-08-08 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-08-22 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-08-08 |
Time |
16:18 |
Sent To |
B |
|
| Notes |
| 2018-08-08 16:28:09 | ZONING REVIEW FAILED, DUE TO THE FOLLOWING: | | | | | | 1) AS THE ALLOWABLE SQUARE FOOTAGE OF THE SIGN IS BASED | | | ON THE SQUARE FOOTAGE OF THE BUILDING FACADE, PLEASE | | | INDICATE THE HEIGHT AND WIDTH OF THE FACADE ON WHICH | | | THE SIGN IS TO BE MOUNTED. IF LEASING A SPACE, PROVIDE | | | HEIGHT AND WIDTH OF LEASED SPACE. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ | | | ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: 561-822-1442 | | | E-MAIL: [email protected] | | | |
|
|
|