Plan Review Details - Permit 18080119
Plan Review Stops For Permit 18080119
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-10-25 Cont ID  
Sent By cthroop Date 2018-10-25 Time 16:23 Rev Time 0.00
Received By cthroop Date 2018-10-25 Time 16:21 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-09-02 Cont ID  
Sent By shill Date 2018-09-02 Time 15:11 Rev Time 0.00
Received By shill Date 2018-09-02 Time 15:11 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-10-26 Cont ID  
Sent By jpearson Date 2018-10-26 Time 07:42 Rev Time 0.00
Received By jpearson Date 2018-10-26 Time 07:42 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-08-27 Cont ID  
Sent By jpearson Date 2018-08-27 Time 10:38 Rev Time 0.00
Received By jpearson Date 2018-08-27 Time 07:09 Sent To  
Notes
2018-08-27 10:38:21CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. ELECTRICAL PLAN IS REQUIRED TO BE SIGNED BY PERSON
 RESPONSIBLE FOR THE DESIGN. PROVIDE CORRECTION. FS
 481.229; WPB FBC 107.2.1, 107.3.5.1.2
 2. ALL RECEPTACLE OUTLETS IN BATHROOM REQUIRE GFCI
 PROTECTION. PROVIDE CORRECTION. NEC 210.8; FBC RE
 E3902.1
 3. LIGHTING IN BATHTUB OR SHOWER AREAS SHALL BE
 SUITABLE FOR DAMP LOCATIONS. NO PARTS OF CORD-CONNECTED
 LUMINAIRES, CHAIN-, CABLE-, OR CORD-SUSPENDED
 LUMINAIRES, LIGHTING TRACK, PENDANTS, OR
 CEILING-SUSPENDED (PADDLE) FANS SHALL BE LOCATED WITHIN
 A ZONE MEASURED 3 FEET HORIZONTALLY AND 8 FEET
 VERTICALLY FROM THE TOP OF THE BATHTUB RIM OR SHOWER
 STALL THRESHOLD. PROVIDE CORRECTION. NEC 410.10(D); FBC
 RE E4003.11; NEC 410.10(D); FBC RE E4003.11
 4. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED
 CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS,
 AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY
 WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5,
 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902
 5. IF ANY ADDITIONAL LOADS ARE BEING ADDED, PROVIDE
 LOAD CALCULATION FOR SERVICE, INCLUDE EXISTING AND NEW
 LOADS TO CONFIRM CAPACITY OF SERVICE IS ADEQUATE. NEC
 215.2, 220, 408.30; FBC RE E3602.2
 6. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED
 PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING
 ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS
 NEW INSTALLATIONS. FBC RE R314.3, R315.1; WPB FBC
 107.2.1
 7. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A
 NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD
 SHEETS?.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-10-26 Cont ID  
Sent By jpearson Date 2018-10-26 Time 09:17 Rev Time 0.00
Received By hmoser Date 2018-10-26 Time 09:19 Sent To  
Notes
2018-10-25 15:14:09ROUTED TO PLUMBING, JERRY SMITH.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-09-04 Cont ID  
Sent By shill Date 2018-09-04 Time 16:38 Rev Time 0.00
Received By shill Date 2018-08-02 Time 11:54 Sent To  
Notes
2018-08-03 11:54:26R26

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2018-10-26 Cont ID  
Sent By hmoser Date 2018-10-26 Time 07:49 Rev Time 0.00
Received By hmoser Date 2018-10-26 Time 07:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-09-04 Cont ID  
Sent By cmontell Date 2018-09-04 Time 12:54 Rev Time 0.00
Received By cmontell Date 2018-09-04 Time 12:51 Sent To  
Notes
2018-09-04 12:54:46MECHANICAL PLAN IS REQUIRED TO BE SIGNED BY PERSON
 RESPONSIBLE FOR THE DESIGN.
  
  
  
 CHRIS MONTELLO
 561-805-6733
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-10-25 Cont ID  
Sent By jesmith Date 2018-10-25 Time 15:42 Rev Time 0.00
Received By jesmith Date 2018-10-25 Time 15:17 Sent To  
Notes
2018-10-25 15:18:05PLUMBING COMMENTS: APPROVED
  
 PROVISO
  
 1. TUB/SHOWER CONTROL VALVE(S) SHALL BE PRESSURE
 BALANCED PB, THERMOSTATIC MIXING (TM) OR COMBINATION
 PB/TM VALVE TYPES WITH HIGH TEMPERATURE LIMITING STOP.
 FBC RES P2708.4
 2. ACCESSIBLE TEMPERATURE LIMITING DEVICE REQUIRED ON
 HOT WATER TO MASTER BATH BATHTUB(S) IS REQUIRED. FBC
 RES P2713.3
 3. HAND HELD SHOWER REQUIRES AN ATMOSPHERIC VACUUM
 BREAKER AT SHOWER ARM OUTLET. FBC RES P2708.5
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711

Review Stop P PLUMBING
Rev No 1 Status P Date 2018-09-04 Cont ID  
Sent By shill Date 2018-09-04 Time 16:38 Rev Time 0.00
Received By jesmith Date 2018-09-04 Time 16:37 Sent To  
Notes
2018-09-07 13:07:50REVIEW COMPLETED BY JERALD SMITH 0017-P
2018-09-04 16:38:231ST REVIEW: FBC 2017 6TH EDITION
 PERMIT 18080119
 PLUMBING COMMENTS: APPROVED; SEE NOTES ON PLAN WHICH
 ARE ALSO NOTED BELOW
  
 1. HAND HELD SHOWER REQUIRES AN ATMOSPHERIC VACUUM
 BREAKER AT SHOWER ARM OUTLET FBC RES 2708.5
 2. SHOWER CONTROL VALVE(S) SHALL BE PRESSURE BALANCED
 PB,THERMOSTATIC MIXING (TM) OR COMBINATION PB/TM VALVE
 TYPES WITH HIGH TEMPERATURE LIMITING STOP FBC RES
 2708.4
 3. ACCESSIBLE TEMPERATURE LIMITING CONTROL DEVICE
 REQUIRED ON HOT WATER TO BATHTUB IS REQUIRED. FBC RES
 2713.3
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711