Plan Review Details - Permit 18071467
| Plan Review Stops For Permit 18071467 |
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2018-08-10 |
|
|
Cont ID |
|
| Sent By |
RRossano |
Date |
2018-08-10 |
Time |
|
Rev Time |
1.00 |
| Received By |
rrossano |
Date |
2018-08-09 |
Time |
|
Sent To |
I |
|
| Notes |
| 2018-08-10 07:43:19 | 1) PLEASE PROVIDE 3000 PSI CONCRETE PER CITY GENERAL | | | CONSTRUCTION STANDARD DETAIL GC-6. | | | 2) PLEASE CLARIFY IF DRIVEWAY IS BEING WIDENED. WORK | | | DESCRIPTION ON APPLICATION IS SHOWN AS "SIDEWALK". | | | 3) SUBMITTED DRAWING APPEARS TO SHOW A PROPOSED | | | EXPANDED DRIVEWAY (25 FEET? NOT CALLED OUT) WITH A | | | FINAL PROPOSED WIDTH OF 29 FEET INCLUDING FLARES. CITY | | | GENERAL CONSTRUCTION STANDARD DETAIL GC-6 ALLOWS FOR 20 | | | FOOT MAX. DRIVEWAY WIDTH WITH ADDITIONAL 3 FT. FLARE ON | | | EACH SIDE. | | | 4) CALL 811 FOR UTILITY LOCATES PROIR TO CONSTRUCTION | | | 48 HOURS BEFORE DIGGING. | | | 5) STREETVIEW SHOWS A TREE TO THE EAST OF THE EXISTING | | | DRIVEWAY THAT MAY BE IMPACTED BY THE PROPOSED DRIVEWAY | | | WIDENING. PLEASE ADVISE. | | | | | | PLEASE RESPOND TO COMMENTS IN WRITING. | | | | | | RICK ROSSANO | | | PROJECT COORDINATOR | | | WPB ENGINEERING SERVICES | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1098 | | | CELL: (561) 246-9525 | | | FAX: (561) 494-1116 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-08-13 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2018-08-13 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-07-31 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2018-08-01 14:19:23 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-08-02 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-08-02 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-08-02 |
Time |
15:54 |
Sent To |
ENG |
|
| Notes |
| 2018-08-02 16:32:03 | ZONING REVIEW FAILED, DUE TO THE FOLLOWING: | | | | | | 1) PURSUANT TO THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS (ZLDR), SECTION 94-312.C.1 - ACCESS TO | | | STREETS. PARKING FOR LESS THAN THREE RESIDENTIAL | | | DWELLING UNITS MAY BE ACHIEVED BY INSTALLING ACCESS | | | POINTS IN ONE OF THE FOLLOWING WAYS: A SINGLE DRIVEWAY | | | WITH A WIDTH OF NO GREATER THAN 20 FEET AT THE PROPERTY | | | LINE OR WHERE THE DRIVEWAY ADJOINS THE APRON IF THE | | | APRON IS NOT LOCATED WHOLLY WITHIN THE RIGHT-OF-WAY. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ | | | ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: 561-822-1442 | | | E-MAIL: [email protected] |
|
|
|
Account Summary | Usage Policy | Privacy Policy