| Plan Review Stops For Permit 18071384 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-10-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-10-26 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-10-26 |
Time |
15:18 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-08-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-08-29 |
Time |
18:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-08-29 |
Time |
10:44 |
Sent To |
B |
|
| Notes |
| 2018-08-29 15:04:15 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SHEET ID-1.3 OF THE PLANS REFERENCES TO THE 2014 FBC | | | UNDER GENERAL NOTES. UNDER THE BUILDING CODE IN EFFECT | | | SECTION THE FIFTH EDITION IS SPECIFIED FOR THE 2017 FBC | | | AND IT SHOULD BE THE SIXTH EDITION. THE FBC SIXTH | | | EDITION (2017) WENT INTO EFFECT ON JANUARY 1, 2018. ALL | | | NEW PERMITS APPLIED FOR ON OR AFTER THAT DATE ARE | | | REQUIRED TO COMPLY WITH AND REFERENCE THE FBC SIXTH | | | EDITION (2017). | | | FS CHAPTER 553 | | | | | | 2) SPECIFY THE FOLLOWING DESIGN CRITERIA: 1) TYPE OF | | | CONSTRUCTION, 2) OCCUPANCY TYPE 3) FIRE SPRINKLERED, 4) | | | WIND SPEED AND 5) EXPOSURE CATEGORY FBC 107.2.1 | | | | | | 3) IT DOES NOT APPEAR THAT THE KITCHEN AREA WOULD BE | | | REQUIRED TO HAVE ONE HOUR FIRE RATED WALLS AND | | | CEILINGS. PLEASE EXPLAIN. FBC 107.2.1 | | | | | | 4) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A | | | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE | | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-10-03 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-10-03 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-10-03 |
Time |
09:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-08-20 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-08-20 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-08-20 |
Time |
14:41 |
Sent To |
|
|
| Notes |
| 2018-08-20 14:41:43 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE CHART OF INTERIOR LIGHTING POWER ALLOWANCES | | | EXPRESSED IN WATTAGE PER THE FBC ENERGY CODE IN | | | RELATION TO THE WATTAGE OF THE CONNECTED INTERIOR | | | LIGHTING PROPOSED TO COMPLY WITH CODE. FBC EC C405.4.2 | | | 2. PROVIDE THE ADDITIONAL AUTOMATIC LIGHTING CONTROLS | | | STIPULATED IN THE FBC ENERGY CODE. FBC EC C405.2 | | | 3. PROVIDE LOAD CALCULATION FOR PANEL AC, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD | | | SHEETS?. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-09-26 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-09-26 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-09-26 |
Time |
10:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-08-06 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-08-06 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-08-06 |
Time |
11:55 |
Sent To |
|
|
| Notes |
| 2018-08-06 12:07:24 | PERMIT # 18071384 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | 1) PROVIDE DRAWING NOTE INDICATING ALL CONSTRUCTION AND | | | DEMOLITION WORK SHALL CONFORM TO THE REQUIREMENTS OF | | | NFPA 241. TRASH AND CONSTRUCTION DEBRIS SHALL BE | | | REMOVED FROM THE SITE DAILY. SMOKING SHALL BE | | | PROHIBITED EXCEPT IN DESIGNATED EXTERIOR AREAS. ALL | | | OTHER DEMOLITION OR CONSTRUCTION AREAS SHALL HAVE "NO | | | SMOKING" SIGNS POSTED. WHERE SMOKING IS PERMITTED, SAFE | | | RECEPTACLES FOR SMOKING MATERIALS SHALL BE PROVIDED. | | | | | | 2) PROVIDE DRAWING NOTE INDICATING, ?FIRE PROTECTION | | | SYSTEMS SHALL REMAIN ACTIVE DURING DEMOLITION AND | | | RENOVATION ACTIVITIES. IN THE EVENT A FIRE PROTECTION | | | SYSTEM IS OUT OF SERVICE FOR MORE THAN 4-HOURS IN A | | | 24-HOUR PERIOD, THE BUILDING SHALL BE PLACED UNDER A | | | FIRE WATCH. ALL FIRE WATCH REQUESTS MUST BE SUBMITTED | | | BY EMAIL ([email protected]) OR IN WRITING (FAX: | | | 561-804-4774) AND APPROVED BY THE OFFICE OF THE FIRE | | | MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY.? | | | | | | 3) SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE | | | INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER | | | SYSTEM AND/OR FIRE ALARM SYSTEM. | | | | | | 4) SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE | | | INSTALLATION OR MODIFICATION OF THE HOOD SUPPRESSION | | | SYSTEM. | | | | | | | | | SUE ELLEN CALDERON | | | ASSISTANT FIRE MARSHAL | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2018-10-16 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2018-10-16 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-10-16 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2018-10-16 14:53:54 | 2ND REVIEW: | | | GAS COMMENTS: APPROVED | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-08-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-08-28 |
Time |
18:02 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-08-28 |
Time |
18:02 |
Sent To |
|
|
| Notes |
| 2018-08-28 18:02:57 | 1ST REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | GAS COMMENTS: | | | 1. OUR RECORDS SHOW THAT THERE IS EXITING LP GAS TANK | | | PROVIDING GAS FOR THE KITCHEN WITH A TOTAL BTU LOAD OF | | | 500,000 UNDER PERMIT #05090527 IT LIST NATURAL GAS ON | | | THE NEW PLANS PLEASE CLARIFY. PER WPB AMEND TO FBC | | | 107.2.1 | | | 2. PLEASE SHOW THE EXISTING BTU LOAD ON THE PLAN THE | | | PIPING FROM THE LP TANK TO THE BRANCH FOR THE NEW LOAD | | | BE NEED TO BE RESIZED. PER FBC FG 402.4 | | | 3. SHOW EXITING PIPING ON RISER WITH SIZE BACK TO THE | | | LP TANK. PER WPB AMEND TO FBC 107.2.1 | | | 4. THE TOTAL BTU LOAD SHOWN ON THE RISER ADDS UP TO | | | 493,000 BTU THE TOTAL LOAD LISTED ON SIZING TABLE NOTES | | | IS 547,000 BTU PLEASE CLARIFY. PER WPB AMEND TO FBC | | | 107.2.1 | | | 5. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE 2017 | | | FBC-FUEL GAS CODE SEC.304.1, 614.6 (CLOTHES DRYERS) OR | | | 2017 FBC-RES. SEC. G 2407.1 AND G2439.4 (. | | | 6. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS / | | | INSTALLATION MANUAL FOR ALL GAS EQUIPMENT AND | | | REGULATORS TO VERIFY COMPLIANCE WITH STANDARDS NFPA 54, | | | NFPA 58, AND FBC-2017 FUEL GAS CODE SEC. 402.2, AND | | | 301.3 OR 2017 FBC-RES. SEC. G2404.3. GAS APPLIANCES | | | SHALL BE LISTED AND LABELED. THE INSTALLATION MANUALS | | | FOR ALL GAS APPLIANCES / EQUIPMENT SHALL BE ONSITE AT | | | THE TIME OF INSPECTION. FGC SEC.305.1, FBC-RES. | | | SEC.G2408.1. | | | 7. THE DISTANCE ON YOUR .5LB SYSTEM IS LISTED AS 106? | | | PER FBC FG (1) THE PIPING SHALL BE 2? PLEASE CLARIFY. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-11-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-11-07 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2018-11-08 13:54:05 | RESUB ROUTED TO JESMITH |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-10-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-10-26 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-09-21 |
Time |
11:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-08-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-08-29 |
Time |
18:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-07-30 |
Time |
15:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2018-08-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-08-29 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-08-29 |
Time |
11:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2018-11-19 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-11-19 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-11-19 |
Time |
07:48 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2018-10-11 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-10-11 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-10-11 |
Time |
07:27 |
Sent To |
|
|
| Notes |
| 2018-10-11 09:24:09 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #18071384 | | | 10/12/18 | | | | | | CODES IN EFFECT: | | | | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) COMMENTS #3- 7 FROM THE 1ST REVIEW PRINTED BELOW | | | HAVE NOT BEEN COMPLETETY ADDRESSED AND STILL EXIST. | | | | | | 3) VERIFY COMPLIANCE WITH SECTION 508.1.1 FBC M- SEE | | | BELOW. | | | | | | 508.1.1 MAKEUP AIR TEMPERATURE. | | | THE TEMPERATURE DIFFERENTIAL BETWEEN MAKEUP AIR AND THE | | | AIR IN THE CONDITIONED SPACE SHALL NOT EXCEED 10 | | | DEGREES F (6 DEGREES C) EXCEPT WHERE THE ADDED HEATING | | | AND COOLING LOADS OF THE MAKEUP AIR DO NOT EXCEED THE | | | CAPACITY OF THE HVAC SYSTEM. | | | | | | (IN RESPONSE TO COMMENT #3 THE ENGINEER STATES IN HIS | | | RESPONSE THAT THE MAKEUP AIR IS LOCATED IN THE HOOD, | | | HOWEVER THIS IN NOT THE CASE AS THE MAKEUP AIR IS | | | DELIVERED VIA AN AIR CURTAIN AT THE FRONT FACE OF THE | | | HOOD. PLEASE CONSULT WITH CAPTIVEAIRE FOR THE | | | PERCENTAGE OF AIR THAT IS DIFFUSED INTO THE SPACE AND | | | HOW THAT HOT AIR IS BEING COOLED TO WITHIN 10 DEGREES | | | OF THE TEMPERATURE IN THE KITCHEN). | | | | | | 4) PROVIDE COOLING AND HEATING CALCULATIONS FOR THE NEW | | | AC SYSTEM- SECTION C403.2.1 FBC EC. PLEASE NOTE THAT IF | | | THE SYSTEM WILL BE USED TO SHOW COMPLIANCE WITH COMMENT | | | #3 ABOVE, THEN THE CALCS SHOULD SPECIFICALLY ADDRESS | | | THE HEAT LOAD IN BTUH GAINED FROM THE PERCENTAGE OF | | | UNCONDITIONED MAKE UP AIR THAT IS NOT EXHAUSTED BY THE | | | HOOD. | | | | | | ( NO AC CALCULATIONS WERE SUBMITTED. PLEASE NOTE THAT | | | THE CALCULATIONS SHALL INDICATE THE HEAT LOADS FOR | | | COOKING APPLIANCES, AND ANY OF THE LOAD FROM THE MAKEUP | | | AIR FOR THE HOOD THAT MAY BE IMPACTING THE KITCHEN | | | SPACE). | | | | | | 5) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR ALL | | | GAS-FIRED COOKING APPLIANCES- SECTION 623.1 FBC FG. | | | | | | (NOT SUBMITTED). | | | | | | 6) PROVIDE COMBUSTION AIR CALCULATIONS FOR THE | | | GAS-FIRED COOKING APPLIANCES AND INDICATE HOW THE AIR | | | IS BEING PROVIDED- SECTION 304.1 FBC FG. | | | | | | (NOT PROVIDED). | | | | | | 7) PROVIDE WIND LOAD ENGINEERING FOR INSTALLATION OF | | | THE EXTERIOR CONDENSER- SECTION 301.15 FBC M. | | | | | | (NOT PROVIDED). | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-08-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-08-23 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-08-23 |
Time |
10:11 |
Sent To |
|
|
| Notes |
| 2018-08-23 11:04:43 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #18071384 | | | 8/23/18 | | | | | | CODES IN EFFECT: | | | | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) ADVISORY: THE CITY OF WEST PALM BEACH BUILDING | | | DEPARTMENT REQUIRES SEPARATE PERMITS FOR KITCHEN | | | EXHAUST HOODS AND FIRE SUPPRESSION SYSTEMS- SEE SECTION | | | 107.2.1 WPB AMENDMENTS TO THE FBC HOWEVER COMMENTS #2 & | | | 3 BELOW PERTAINING TO THE HOOD SHOULD BE ADDRESSED NOW | | | TO AVOID CONFLICTS LATER WITH THE HOOD PERMIT. | | | | | | 2) THE LOCATION OF THE KEF EXHAUST FAN DOES NOT APPEAR | | | TO BE IN COMPLIANCE WITH SECTIONS 506.3.13.2 AND | | | 506.3.13.3 FBC M. PLEASE REVIEW THE CODE SECTIONS BELOW | | | AND VERIFY COMPLIANCE OR RELOCATE THE TERMINATION. | | | | | | 506.3.13.2 TERMINATION THROUGH AN EXTERIOR WALL. | | | EXHAUST OUTLETS SHALL BE PERMITTED TO TERMINATE THROUGH | | | EXTERIOR WALLS WHERE THE SMOKE, GREASE, GASES, VAPORS | | | AND ODORS IN THE DISCHARGE FROM SUCH TERMINATIONS DO | | | NOT CREATE A PUBLIC NUISANCE OR A FIRE HAZARD. SUCH | | | TERMINATIONS SHALL NOT BE LOCATED WHERE PROTECTED | | | OPENINGS ARE REQUIRED BY THE FLORIDA BUILDING CODE, | | | BUILDING. OTHER EXTERIOR OPENINGS SHALL NOT BE LOCATED | | | WITHIN 3 FEET (914 MM) OF SUCH TERMINATIONS. | | | | | | 506.3.13.3 TERMINATION LOCATION. | | | EXHAUST OUTLETS SHALL BE LOCATED NOT LESS THAN 10 FEET | | | (3048 MM) HORIZONTALLY FROM PARTS OF THE SAME OR | | | CONTIGUOUS BUILDINGS, ADJACENT BUILDINGS AND ADJACENT | | | PROPERTY LINES AND SHALL BE LOCATED NOT LESS THAN 10 | | | FEET (3048 MM) ABOVE THE ADJOINING GRADE LEVEL. EXHAUST | | | OUTLETS SHALL BE LOCATED NOT LESS THAN 10 FEET (3048 | | | MM) HORIZONTALLY FROM OR NOT LESS THAN 3 FEET (914 MM) | | | ABOVE AIR INTAKE OPENINGS INTO ANY BUILDING. | | | | | | 3) VERIFY COMPLIANCE WITH SECTION 508.1.1 FBC M- SEE | | | BELOW. | | | | | | 508.1.1 MAKEUP AIR TEMPERATURE. | | | THE TEMPERATURE DIFFERENTIAL BETWEEN MAKEUP AIR AND THE | | | AIR IN THE CONDITIONED SPACE SHALL NOT EXCEED 10 | | | DEGREES F (6 DEGREES C) EXCEPT WHERE THE ADDED HEATING | | | AND COOLING LOADS OF THE MAKEUP AIR DO NOT EXCEED THE | | | CAPACITY OF THE HVAC SYSTEM. | | | | | | 4) PROVIDE COOLING AND HEATING CALCULATIONS FOR THE NEW | | | AC SYSTEM- SECTION C403.2.1 FBC EC. PLEASE NOTE THAT IF | | | THE SYSTEM WILL BE USED TO SHOW COMPLIQNCE WITH COMMENT | | | #3 ABOVE, THEN THE CALCS SHOULD SPECIFICALLY ADDRESS | | | THE HEAT LOAD IN BTUH GAINED FROM THE PERCENTAGE OF | | | UNCONDITIONED MAKE UP AIR THAT IS NOT EXHAUSTED BY THE | | | HOOD. | | | | | | 5) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR ALL | | | GAS-FIRED COOKING APPLIANCES- SECTION 623.1 FBC FG. | | | | | | 6) PROVIDE COMBUSTION AIR CALCULATIONS FOR THE | | | GAS-FIRED COOKING APPLIANCES AND INDICATE HOW THE AIR | | | IS BEING PROVIDED- SECTION 304.1 FBC FG. | | | | | | 7) PROVIDE WIND LOAD ENGINEERING FOR INSTALLATION OF | | | THE EXTERIOR CONDENSER- SECTION 301.15 FBC M. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-11-08 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2018-11-08 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-11-08 |
Time |
14:22 |
Sent To |
|
|
| Notes |
| 2018-11-08 14:23:35 | APPROVED | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-10-16 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2018-10-16 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-10-16 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2018-10-16 14:13:15 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 2ND REVIEW: | | | PLUMBING COMMENTS: DENIED | | | | | | 1. RE: PLAN SHEET P-1; PLAN SHOWS CONNECTION OF NEW 3" | | | KITCHEN GREASY WASTE TO AN EXISTING 4" GREASY WASTE | | | BUILDING DRAIN WHICH IS CONNECTED TO AN EXISTING 2000 | | | GALLON GREASE INTERCEPTOR. WHERE IS 4" GREASY WASTE | | | COMING FROM? PROVIDE SIZING CALCULATIONS FOR EXISTING | | | FACILITY AS WELL AS SIZING CALCULATIONS FOR NEW WORK TO | | | DETERMINE THAT THE INTERCEPTOR IS SIZED TO ACCOMMODATE | | | ALL PER WPB FBC 107.2.1. | | | 2. RE: PLAN SHEET P-2; SANITARY ISOMETRIC SHOWS A | | | COMMON INDIRECT WASTE FROM TWO (2) ITEM #20 HOT FOOD | | | WELLS TO THE FLOOR SINK. PROVIDE INDEPENDENT INDIRECT | | | WASTE FOR EACH WELL IN ACCORDANCE WITH 802.1.1 . | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED "VOID". | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-08-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-08-28 |
Time |
18:03 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-08-28 |
Time |
18:03 |
Sent To |
|
|
| Notes |
| 2018-08-28 18:10:10 | 1ST REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PROVIDE SANITARY AND WATER ISOMETRIC. PER WPB AMEND | | | TO FBC 107.3.5.1.3(13) | | | 2. I THE PLUMBING FIXTURES ARE OVER 50' FROM HOT WATER | | | SOURCE A RECIRCULATION SYSTEM IS REQUIRED. PER FBC PL | | | 607.2 | | | 3. PROVIDE SIZING CALCULATIONS FOR GREASE INTERCEPTOR | | | FROM MANUFACTURE SCHIER PROVIDES THEM ON THEIR WEB | | | SITE. PER WPB AMEND TO FBC 107.2.1 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|