Plan Review Details - Permit 18071331
| Plan Review Stops For Permit 18071331 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-04-25 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-04-25 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-04-25 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2019-06-07 15:26:29 | PROVIDE COPY OF REVISED S1 SHEET FOR THE SECOND SET. | | | | | | THANK YOU, | | | DYLAN BATTLES | | | 561-805-6718 | | | [email protected] | | | | | | THE CITY OF WEST PALM BEACH | | | BUILDING PLANS EXAMINER PX4191 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-09-12 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-09-12 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-09-12 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2018-09-12 09:57:06 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 18071331 | | | REVIEWED: SEPTEMBER 11, 2018 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER I | | | [email protected] | | | 561-805-6718 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC A = AMENDMENTS TO THE FLORIDA BUILDING CODE,6TH | | | EDITION (2017) | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. [FBC AMENDED 109]PLEASE HAVE ENGINEER PROVIDE COST | | | ESTIMATE BASED ON THE WORK AS IF IT WERE BEING | | | PERFORMED BY A GENERAL CONTRACTOR. EVEN THOUGH YOU ARE | | | OWNER/BUILDER THE BUILDING DEPARTMENT FEES ARE | | | GENERATED BY INDUSTRY COST FOR SIMILAR WORK. IF COST | | | ESTIMATE CANNOT BE PROVIDED WE WILL ADJUST THE VALUE | | | BASED ON THE SQUARE FOOTAGE ADDED. | | | | | | 2. [FBC R318]INDICATE THE MEANS OF TERMITE PROTECTION | | | PROPOSED AND HOW IT WILL BE ACCOMPLISHED WITH AN | | | EXISTING SLAB. | | | | | | A) [FBC A107.2.6]THE EXTISTING FOOTING WASN?T DESIGNED | | | TO HOLD A MASONRY WALL AND ROOF ABOVE. PLEASE PROVIDE | | | FOOTER THAT WILL MEET CODES BELOW. | | | [FBC R403.1.4]MINIMUM DEPTH. | | | EXTERIOR FOOTINGS SHALL BE PLACED NOT LESS THAN 12 | | | INCHES (305 MM) BELOW THE UNDISTURBED GROUND SURFACE. | | | WHERE APPLICABLE, THE DEPTH OF FOOTINGS SHALL ALSO | | | CONFORM TO SECTIONS R403.1.4.1 THROUGH R403.1.4.2. | | | | | | B) [FBC R404.1.6]CONCRETE AND MASONRY FOUNDATION WALLS | | | SHALL EXTEND ABOVE THE FINISHED GRADE ADJACENT TO THE | | | FOUNDATION AT ALL POINTS A MINIMUM OF 4 INCHES (102 MM) | | | WHERE MASONRY VENEER IS USED AND A MINIMUM OF 6 INCHES | | | (152 MM) ELSEWHERE. | | | | | | 3. [FBC 2121.1.6]MINIMUM NO. 9 GAUGE TRUSS-TYPE | | | HORIZONTAL JOINT REINFORCING AT EVERY ALTERNATE COURSE | | | (16-INCH (406 MM) SPACING], SHALL BE PROVIDED. THIS | | | REINFORCEMENT SHALL EXTEND 4 INCHES (102 MM) INTO TIE | | | COLUMNS OR BE TIED TO STRUCTURAL COLUMNS WITH APPROVED | | | METHODS WHERE STRUCTURAL COLUMNS REPLACE THE TIE | | | COLUMNS. IN ADDITION, HORIZONTAL JOINT REINFORCEMENT | | | SHALL COMPLY WITH TMS602/ACI530.1/ASCE 6 SECTIONS 2.4C | | | THRU 2.4F AND SECTION 3.4B.7. | | | | | | 4. FBC R301.4]&[FBC R301.5]PROVIDE DEAD LOAD AND LIVE | | | LOAD FROM EXISTING ROOF. | | | [FBC R806]ARE VENTS BEING REMOVED FROM THE OVERHANG? | | | PROVIDE HOW VENTING IS BEING SUPPLIED AND IF EXISTING | | | VENTS COVER THE WHOLE ATTIC SPACE. | | | | | | 5. [FBC ENERGY R502]WHAT IS EXISTING CEILING MATERIAL | | | AS IT IS CURRENTLY EXTERIOR PATIO? | | | HOW WILL R-30 BE INSTALLED IN EXISTING CEILING IF ROOF | | | AND CEILING ARE NOT BEING REPLACED. | | | | | | NOTE: | | | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | | OF MATERIALS REQUESTED. | | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-05-02 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2019-05-02 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2019-05-02 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2019-05-02 10:58:44 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. AFCI PROTECTION SHOWN IN NOT CODE COMPLIANT. ALL | | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | | SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND | | | POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH | | | AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC | | | 210.8, 210.12; FBC RE E3902 | | | 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | | 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 | | | 3. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | | 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1, | | | E3609.3; WPB FBC 107.2.1 | | | 4. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | 5. A MINIMUM OF TWO 20 AMPERE BRANCH CIRCUIT SHALL BE | | | PROVIDED TO SUPPLY KITCHEN COUNTERTOP RECEPTACLE | | | OUTLET(S). PROVIDE CORRECTION. NEC 210.11(C)(1) , FBC | | | RE E3703.2 | | | 6. OK | | | 7. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING | | | ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS | | | NEW INSTALLATIONS. FBC RE R314.3, R315.1; WPB FBC | | | 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD | | | SHEETS?. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-08-28 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-08-28 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-08-28 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2018-08-28 13:22:56 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. AFCI PROTECTION SHOWN IN NOT CODE COMPLIANT. ALL | | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | | SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND | | | POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH | | | AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC | | | 210.8, 210.12; FBC RE E3902 | | | 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | | 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 | | | 3. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | | 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1, | | | E3609.3; WPB FBC 107.2.1 | | | 4. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | 5. A MINIMUM OF TWO 20 AMPERE BRANCH CIRCUIT SHALL BE | | | PROVIDED TO SUPPLY KITCHEN COUNTERTOP RECEPTACLE | | | OUTLET(S). PROVIDE CORRECTION. NEC 210.11(C)(1) , FBC | | | RE E3703.2 | | | 6. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 | | | 7. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING | | | ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS | | | NEW INSTALLATIONS. FBC RE R314.3, R315.1; WPB FBC | | | 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD | | | SHEETS?. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2019-04-29 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-04-29 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-04-29 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2019-04-29 13:28:15 | GAS 2ND REVIEW**DENIED**THESE ARE THE SAME COMMENTS | | | FROM PERMIT#19010365. PLEASE NOTE FL ST 553.80 (B)2B | | | WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | IT IS RECOMMENDED FOR YOU TO COME IN AND MEET WITH THE | | | PLAN REVIEW STAFF BEFORE RESUBMITTING. | | | | | | NOTE:THE PLANS INDICATE AN EXISTING GAS METER. THE BTU | | | LOAD OF THE EXISTING GAS SYSTEM MUST BE ADDED INTO THE | | | TOTAL BTU LOAD ON THE SYSTEM TO ENSURE THE EXISTING | | | SYSTEM IS PROPERLY SIZED. IF UNDERSIZED, THE EXISTING | | | SYSTEM MUST BE REDONE TO ENSURE A SAFE OPERATING | | | SYSTEM. SUBMIT A GAS PIPING RISER DIAGRAM THAT SHOWS | | | THE TYPE OF EXISTING APPLIANCE, THE BTU LOAD OF EACH | | | APPLIANCE, THE PIPE SIZE AND TYPE OF PIPE TO EACH | | | APPLIANCE, AND THE DISTANCE OF THE LONGEST LENGTH OF | | | PIPING FROM THE POINT OF DELIVERY TO THE MOST REMOTE | | | OUTLET AND THE LOAD OF THE SECTION. NOTE: IF THE | | | EXISTING SYSTEM IS LESS THAN A 2 PSI SYSTEM AND THE | | | SYSTEM PRESSURE IS INCREASED TO 2 PSI, A LINE PRESSURE | | | REGULATOR IS REQUIRED AT ALL THE EXISTING APPLIANCES. | | | FGC SECS. 401.4, 401.8, 402.1, 402.2, 402.3 OR FBCR | | | SECS.G2412.4, G2412.8, G2413.1, G2413.2, G2413.3. | | | | | | | | | 1) SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS THE | | | LENGTH OF ALL CUT SECTIONS OF PIPE. GAS RANGE IS NOT | | | SHOWING ON GAS ISOMETRIC DRAWING BUT SHOWS AS BEING | | | RELOCATED. FBC-RES SEC. G2413.4.1, G2413.4.2. | | | | | | 2) SUBMIT COMBUSTION AIR CALCULATIONS FOR THE RANGE. | | | WHERE COMBUSTION AIR IS PROVIDED BY THE BUILDING?S | | | MECHANICAL VENTILATION SYSTEM, THE SYSTEM SHALL PROVIDE | | | THE SPECIFIED COMBUSTION AIR RATE IN ADDITION TO THE | | | REQUIRED VENTILATION AIR. 2017 FBCR G2407.9.3. | | | | | | 3) SUBMIT MANUFACTURER?S SPECIFICATION SHEETS / | | | INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY | | | COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | | FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2017 | | | FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED | | | AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS | | | APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF | | | INSPECTION.2017, FBC-RES. SEC.G2408.1 | | | | | | 4) SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE 2017 | | | FBC-RES. SEC. G 2407.1 AND G2439.4 (CLOTHES DRYERS) | | | | | | 5) SUBMIT TWO COPIES OF A HOUSE PLAN SHOWING THE | | | LOCATION OF THE TANKLESS WATER HEATER AND THE LOCATION | | | AND DISTANCE OF ANY OPERABLE DOORS OR WINDOWS IN | | | RELATION TO THE WATER HEATER. THE LOCATION OF THE WATER | | | HEATER SHALL COMPLY WITH THE MANUFACTURER'S | | | INSTALLATION INSTRUCTIONS. THE HOUSE PLAN CAN BE HAND | | | DRAWN. WPB AMEND. TO FBC SEC. 107.2. | | | | | | 6) PLANS SUBMITTED ARE NOT SIGNED BY THE PERSON | | | DESIGNING THE SYSTEM AS REQUIRED. FAC 471, 481 | | | | | | 7) VALUE OF JOB IS TOO LOW. $800.00 DOES NOT COVER THE | | | COST OF THE DRYER AND TANKLESS WATER HEATER ALONE. COST | | | MUST INCLUDE ALL MATERIAL AND LABOR. FOR OWNER BUILDER | | | IT SHOULD BE VALUED AS IF WAS CONTRACTED OUT. 109.3 | | | BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF THE | | | BUILDING OFFICIAL, THE CLAIMED VALUATION OF BUILDING, | | | ALTERATION, STRUCTURE, ELECTRICAL, GAS, MECHANICAL OR | | | PLUMBING SYSTEMS APPEARS TO BE UNDERESTIMATED ON THE | | | APPLICATION, THE PERMIT SHALL BE DENIED, UNLESS THE | | | APPLICANT CAN SHOW DETAILED, QUANTITY ESTIMATES, AND/OR | | | BONA FIDE SIGNED CONTRACTS (EXCLUDING LAND VALUE) TO | | | MEET THE APPROVAL OF THE BUILDING OFFICIAL. FOR | | | PERMITTING PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS | | | SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | | CITY OF WEST PALM BEACH | | | 561-248-2703 | | | [email protected] | | | [email protected] | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2018-09-07 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-09-07 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2018-09-07 12:54:19 | REVIEW COMPLETED BY JERALD SMITH 0017-P | | | | | | GAS PLAN REVIEW | | | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | | PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT | | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | | SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE | | | FBC-R, SEC. G2404.3. | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL | | | GAS SEC. 301.3. | | | | | | A SEPARATE PERMIT AND PLANS IS REQUIRED FOR THE GAS | | | INSTALLATION OR MODIFICATION OF SYSTEM. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-05-06 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-05-06 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2019-04-23 |
Time |
14:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-09-12 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-09-12 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-07-27 |
Time |
13:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2018-09-12 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-09-12 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-09-12 |
Time |
09:57 |
Sent To |
|
|
| Notes |
| 2018-09-12 09:58:06 | [FBC AMENDED 109]PLANS REQUIRE REVIEW BY THE PBC IMPACT | | | FEE OFFICE. CALL (561) 233-5025. UPON APPROVAL, YOU MAY | | | CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR | | | REVIEW. PLEASE RETURNED STAMPED AND WITH A COPY OF THE | | | RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE | | | OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO | | | V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN | | | AIRE.PDF |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-04-30 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-04-30 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-04-30 |
Time |
14:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2018-09-04 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-09-04 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-09-04 |
Time |
14:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2019-04-29 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-04-29 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-04-29 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2019-04-29 13:45:27 | PLUMBING 2ND REVIEW**DENIED** | | | | | | 1) ONLY 1 NEW SHT S1 WAS PROVIDE. 2 COPIES OF ALL PLANS | | | ARE REQUIRED. FBC 107.1 | | | | | | 2) PLUMBING ISOMETRIC PLAN DOES NOT MATCH FLOOR PLAN | | | LAY OUT OR 2ND ISOMETRIC DRAWING PROVIDED. PLEASE | | | CLARIFY AND REMOVE ALL PAGES NOT PART OF THE REVIEW | | | PROCESS. FBC 107.3.5 | | | | | | 3) SHT. S2 SHOWS GAS TANKLESS SHOWS INSIDE BUT SEPERATE | | | SHEET FLAT DRAWING IS SHOWING IT OUTSIDE. PLEASE | | | CLARIFY. FBC 107.2.1. PROVIDE DISTANCE FROM ALL DOORS | | | AND WINDOWS. | | | | | | | | | TIM HUNT | | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | | CITY OF WEST PALM BEACH | | | 561-248-2703 | | | [email protected] | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-09-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-06 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-09-06 |
Time |
11:34 |
Sent To |
|
|
| Notes |
| 2018-09-07 12:52:48 | REVIEW COMPLETED BY JERALD SMITH 0017-P | | 2018-09-06 11:38:35 | 1ST REVIEW: FBC 2017 6TH EDITION | | | PERMIT 18071331 | | | PLUMBING COMMENTS: DENIED | | | | | | 1. REGARDING SANITARY PLUMBING RISER ON PLAN SHEET S1: | | | (A) WHAT DOES THE TERM 2" STACK NOTED ON DIAGRAM | | | INDICATE? PLEASE CLARIFY. | | | (B) AUTOMATIC CLOTHES WASHERS REQUIRE A FIXTURE TRAP | | | PER 2017 FBC RES 3201.6 AND A VENT PER 2017 FBC RES | | | 3105.1. THIS IS NOTED ON A DETAIL ON PLAN SHEET S2 BUT | | | MUST ALSO BE SHOWN ON THE SANITARY RISER DIAGRAM ON | | | PLAN SHEET S1. | | | (C) PLEASE COORDINATE WITH STRUCTURAL TO INSURE THAT | | | STRUCTURAL INTEGRITY WILL NOT BE AFFECTED BY PIPING | | | (REFER TO 1/4" SCALE "NEW FLOOR PLAN" ON PLAN SHEET | | | S1). | | | | | | 2. (A) THERE IS A GAS FIRED TANKLESS WATER HEATER AND A | | | GAS DRYER NOTED ON PLAN SHEET S2. A GAS PLAN HAS NOT | | | BEEN INCLUDED IN THIS SUBMITTAL PACKAGE. A GAS PLAN | | | REVIEW HAS NOT BEEN PERFORMED AT THIS TIME. A SEPARATE | | | GAS PERMIT AND PLANS WILL BE REQUIRED FOR A CONTRACTOR | | | TO PERFORM THE RELATED WORK PER WPB AMEND. TO FBC SEC. | | | 105.1. PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT | | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | | SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC. | | | 107.2.1. GAS APPLIANCES SHALL BE LISTED AND LABELED PER | | | THE 2017 FBC RES, SEC. G2404.3. | | | (B) THE PLANS INDICATE AN EXISTING GAS RANGE. THE BTU | | | LOAD OF THE EXISTING GAS SYSTEM MUST BE ADDED INTO THE | | | TOTAL BTU LOAD ON THE SYSTEM TO ENSURE THE EXISTING | | | SYSTEM IS PROPERLY SIZED. IF UNDERSIZED, THE EXISTING | | | SYSTEM MUST BE REDONE TO ENSURE A SAFE OPERATING | | | SYSTEM. SUBMIT A GAS PIPING RISER DIAGRAM THAT SHOWS | | | THE TYPE OF EXISTING APPLIANCE, THE BTU LOAD OF EACH | | | APPLIANCE, THE PIPE SIZE AND TYPE OF PIPE TO EACH | | | APPLIANCE, AND THE DISTANCE OF THE LONGEST LENGTH OF | | | PIPING FROM THE POINT OF DELIVERY TO THE MOST REMOTE | | | OUTLET AND THE LOAD OF THE SECTION. NOTE: IF THE | | | EXISTING SYSTEM IS LESS THAN A 2 PSI SYSTEM AND THE | | | SYSTEM PRESSURE IS INCREASED TO 2 PSI, A LINE PRESSURE | | | REGULATOR IS REQUIRED AT ALL THE EXISTING APPLIANCES. | | | 2017 FBC RES SECS.G2412.4, G2412.8, G2413.1, G2413.2, | | | G2413.3. | | | (C) A SEPARATE PERMIT AND PLANS IS REQUIRED FOR THE GAS | | | INSTALLATION OR MODIFICATION OF SYSTEM. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-05-06 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2019-05-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2019-05-06 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-08-10 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2018-08-10 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2018-08-10 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2018-08-10 14:45:21 | **********************************ZONING REVIEW | | | FAILED****************************************** | | | | | | PROVIDE A SURVEY/SITEPLAN SHOWING THE SETBACKS (BOTH | | | CURRENT AND PROPOSED) FOR ENCLOSURE/RENOVATION. | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] | | | | | | |
|
|
|