| Plan Review Stops For Permit 18071301 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-12-26 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-12-26 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-12-26 |
Time |
12:44 |
Sent To |
|
|
| Notes |
| 2018-12-26 12:59:33 | PROVISO: | | | OWNER TO SIGN ENERGY CALCULATIONS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-12-03 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-12-03 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-12-03 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2018-12-03 15:31:59 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 18071301 | | | REVIEWED: AUGUST 24, 2018 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FLOOD ZONE = X | | | | | | 2ND REVIEW | | | DECEMBER 03,2018 | | | | | | 1. [FBC R401.3]PROVIDE SITE DRAINAGE PLAN. | | | | | | 2ND REVIEW - DRAINAGE PLAN HAS NOT BEEN SUBMITTED. | | | IT SHOULD INCLUDE KEY ELEVATIONS SUCH AS BASE FLOOR | | | ELEVATION (B.F.E.) SINCE GRADE NEEDS TO BE 4 INCHES | | | BELOW SLAB YOU WOULD START DRAINAGE FROM FOUNDATION -4 | | | INCHES. | | | OTHER KEY POINTS ARE 2% GRADE FROM BACK YARD TO STORM | | | DRAIN AT STREET. | | | PLEASE CALL IF ANY QUESTIONS ABOUT DRAINAGE PLAN. | | | | | | [FBC R403.1.7.3] FOUNDATION ELEVATION. ON GRADED SITES, | | | THE TOP OF ANY EXTERIOR FOUNDATION SHALL EXTEND ABOVE | | | THE ELEVATION OF THE STREET GUTTER AT POINT OF | | | DISCHARGE OR THE INLET OF AN APPROVED DRAINAGE DEVICE A | | | MINIMUM OF 12 INCHES (305 MM) PLUS 2 PERCENT. ALTERNATE | | | ELEVATIONS ARE PERMITTED SUBJECT TO THE APPROVAL OF THE | | | BUILDING OFFICIAL, PROVIDED IT CAN BE DEMONSTRATED THAT | | | REQUIRED DRAINAGE TO THE POINT OF DISCHARGE AND AWAY | | | FROM THE STRUCTURE IS PROVIDED AT ALL LOCATIONS ON THE | | | SITE. | | | | | | [FBC AMENDED 107.2.5] 107.2.5 SITE PLAN. THE | | | CONSTRUCTION DOCUMENTS SUBMITTED WITH THE APPLICATION | | | FOR PERMIT SHALL BE ACCOMPANIED BY A SITE PLAN SHOWING | | | TO SCALE THE SIZE AND LOCATION OF NEW CONSTRUCTION AND | | | EXISTING STRUCTURES ON THE SITE, DISTANCES FROM LOT | | | LINES, THE ESTABLISHED STREET GRADES AND THE PROPOSED | | | FINISHED GRADES, DEPICTING THE PROPOSED LOT DRAINAGE | | | AND, AS APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND | | | DESIGN FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN | | | ACCORDANCE WITH AN ACCURATE AND INCLUDED ON A BOUNDARY | | | LINE SURVEY. | | | | | | 2. [FBC R401.4]PROVIDE SOIL REPORT TO SHOW BEARING | | | CAPACITY AND FOUNDATION RECOMMENDATIONS. | | | | | | 2ND REVIEW - SOIL REPORT NOT PROVIDED. ACCORDING TO | | | SOIL MAP WE MAINTAIN AT BLDG. DEPT. YOUR SITE IS IN AN | | | AREA THAT DOES REQUIRE SOIL REPORT. | | | PLEASE PROVIDE SOIL REPORT WITH RE-SUBMITTAL. | | | | | | 3. OK | | | | | | 4. OK | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-08-24 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-08-24 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-08-24 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2018-08-24 13:21:01 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 18071301 | | | REVIEWED: AUGUST 24, 2018 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FLOOD ZONE = X | | | | | | 1. [FBC R401.3]PROVIDE SITE DRAINAGE PLAN. | | | | | | [FBC R403.1.7.3] FOUNDATION ELEVATION. ON GRADED SITES, | | | THE TOP OF ANY EXTERIOR FOUNDATION SHALL EXTEND ABOVE | | | THE ELEVATION OF THE STREET GUTTER AT POINT OF | | | DISCHARGE OR THE INLET OF AN APPROVED DRAINAGE DEVICE A | | | MINIMUM OF 12 INCHES (305 MM) PLUS 2 PERCENT. ALTERNATE | | | ELEVATIONS ARE PERMITTED SUBJECT TO THE APPROVAL OF THE | | | BUILDING OFFICIAL, PROVIDED IT CAN BE DEMONSTRATED THAT | | | REQUIRED DRAINAGE TO THE POINT OF DISCHARGE AND AWAY | | | FROM THE STRUCTURE IS PROVIDED AT ALL LOCATIONS ON THE | | | SITE. | | | | | | [FBC AMENDED 107.2.5] 107.2.5 SITE PLAN. THE | | | CONSTRUCTION DOCUMENTS SUBMITTED WITH THE APPLICATION | | | FOR PERMIT SHALL BE ACCOMPANIED BY A SITE PLAN SHOWING | | | TO SCALE THE SIZE AND LOCATION OF NEW CONSTRUCTION AND | | | EXISTING STRUCTURES ON THE SITE, DISTANCES FROM LOT | | | LINES, THE ESTABLISHED STREET GRADES AND THE PROPOSED | | | FINISHED GRADES, DEPICTING THE PROPOSED LOT DRAINAGE | | | AND, AS APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND | | | DESIGN FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN | | | ACCORDANCE WITH AN ACCURATE AND INCLUDED ON A BOUNDARY | | | LINE SURVEY. | | | | | | 2. [FBC R401.4]PROVIDE SOIL REPORT TO SHOW BEARING | | | CAPACITY AND FOUNDATION RECOMMENDATIONS. | | | | | | 3. [FBC AMENDED 107.3.4.1]SUBMIT TRUSS SHOP DRAWINGS, | | | OR INDICATE THAT THE SUBMITTAL WILL BE DEFERRED. | | | DEFERRED SUBMITTALS TO BE REVIEWED PRIOR TO | | | INSTALLATION. | | | | | | 4. [FBC TABLE R301.2(4)]THE ELEVATION FOR GARAGE DOOR | | | ON 2-4 SHOWS PRESSURES OF +37.08/-50.61. THIS EXCEEDS | | | THE ALLOWED PRESSURE IN PRODUCT APPROVAL. HOWEVER, IF | | | YOU USE TABLE R301.2(4)THE GARAGE DOOR PRESSURE CAN BE | | | ADJUSTED AND WILL MEET THE DESIGN PRESSURE IN NOA | | | 17-1010.16. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-11-29 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-11-29 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-11-29 |
Time |
09:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-08-17 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-08-17 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-08-17 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2018-08-17 16:03:57 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. AFCI PROTECTION SHOWN IN NOT CODE COMPLIANT. ALL | | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | | SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND | | | POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH | | | AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC | | | 210.8, 210.12; FBC RE E3902 | | | 2. PROVIDE AIC RATING OF SERVICE DISCONNECT AND PANEL. | | | NEC 110.3, 110.9; FBC RE E3603.3 | | | 3. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10; FBC RE E3603.3 | | | 4. LOAD CALCULATION ONLY SHOWS ONE SMALL APPLIANCE | | | CIRCUIT INCLUDED IN CALCULATION, THERE MUST BE A | | | MINIMUM OF TWO AND EACH LISTED IN PANEL SCHEDULE SHOULD | | | BE INCLUDED. PROVIDE CORRECTION. NEC 215.2, 220, | | | 408.30; FBC RE E3602.2 | | | 5. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | | 210.8(D); FBC RE E3902.10 | | | 6. GFCI PROTECTION IS REQUIRED FOR ALL RECEPTACLE | | | OUTLETS IN GARAGE, INCLUDING GARAGE DOOR OPENER. | | | PROVIDE CORRECTION. NEC 210.8; FBC RE E3902.2 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD | | | SHEETS?. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-01-11 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-01-11 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-01-10 |
Time |
09:42 |
Sent To |
|
|
| Notes |
| 2019-01-11 09:42:47 | ROUTED TO DBATTLES |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-01-07 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-01-07 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-12-19 |
Time |
13:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-12-11 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2018-12-11 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-12-11 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2018-12-08 10:40:06 | 12/8 REMOVED FROM BOARD, TO JESMITH DESK | | | | | | | | 2018-11-07 15:28:50 | R05 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-09-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-04 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-27 |
Time |
11:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2019-01-11 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-01-11 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-01-11 |
Time |
16:57 |
Sent To |
|
|
| Notes |
| 2019-01-11 16:58:20 | STAMP ON PLANS - OK | | | MU-2019-000852-0000 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2018-08-24 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-08-24 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-08-24 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2018-12-26 13:01:53 | UPON ZONING REVIEW CHECK OUT ONE SET OF PLANS TO TAKE | | | TO PBC IMPACT REVIEW. | | | RETURN THE SET WITH STAMP ON PLANS. | | | PROVIDE A COPY OF RECEIPT TO SHOW MU NUMBER. | | | | | 2018-08-24 09:13:02 | [FBC AMENDED 109]PLANS REQUIRE REVIEW BY THE PBC IMPACT | | | FEE OFFICE. CALL (561) 233-5025. UPON APPROVAL, YOU MAY | | | CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR | | | REVIEW. PLEASE RETURNED STAMPED AND WITH A COPY OF THE | | | RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE | | | OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO | | | V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN | | | AIRE.PDF |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-12-21 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-12-21 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-12-21 |
Time |
14:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2018-08-08 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-08-08 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-08-08 |
Time |
14:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-12-11 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2018-12-11 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-12-11 |
Time |
14:23 |
Sent To |
|
|
| Notes |
| 2018-12-11 14:24:23 | APPROVED | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-09-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-04 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-09-04 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2018-09-07 12:32:20 | REVIEW COMPLETED BY JERALD SMITH 0017-P | | 2018-09-04 10:36:53 | 1ST REVIEW: FBC 2017 6TH EDITION | | | | | | PLUMBING COMMENTS: DENIED | | | | | | 1. EACH WET VENTED FIXTURE DRAIN SHALL CONNECT | | | INDEPENDENTLY TO THE HORIZONTAL WET VENT PER FBC RES | | | P3108.1. THE TUB AND THE SHOWER FIXTURE DRAINS IN | | | BATHROOMS ARE CONNECTED TO WATER CLOSET FIXTURE DRAIN; | | | THE RESULTING FIXTURE BRANCH IS CONNECTED TO THE WET | | | VENT; THIS IS NOT ACCEPTABLE. | | | | | | 2. WATER HEATER IS ON RAISED FLOOR AT SAME ELEVATION AS | | | LIVING AREA ADJACENT TO LIVING AREA FLOOR. IF STORAGE | | | TYPE THEN PROVIDE PAN PER FBC RES 2801.6. | | | | | | 3. ADDITIONAL INFO/DATA REQUIRED FOR WATER HEATER (FBC | | | 107.2.1) TO INCLUDE TYPE AND CAPACITY; WATER HEATER | | | SHALL COMPLY WITH ENERGY CODE. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2018-08-24 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-08-24 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-08-24 |
Time |
13:18 |
Sent To |
|
|
| Notes |
| 2018-08-24 13:18:58 | SHINGLE ROOF PRODUCT APPROVAL OK FOR 5:12 PITCH. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
N |
Date |
2019-01-04 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2019-01-04 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
awooten |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
awotten |
Date |
2018-12-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2018-12-06 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-08-13 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
2018-08-13 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-08-13 14:33:46 | **************************************ZONING REVIEW FAI | | | LED**************************************************** | | | | | | PLEASE SUBMIT A SEPARATE LANDSCAPE AND IRRIGATION | | | PERMIT. SHOWING THE FOLLOWING: | | | RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM | | | BEACH | | | SECTION 94-442(C)(2)A. SINGLE FAMILY DWELLING UNITS | | | | | | O GROSS LOT SQUARE FOOTAGE MINUS | | | O BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS | | | O OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA) | | | O ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE | | | OR PORTION THEREOF | | | O ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE | | | OR PORTION THEREOF | | | | | | PROPOSED DRIVEWAY REQUIRES A SEPARATE PERMIT. | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | PLANNING DIVSION | | | 561-822-1449 | | | [email protected] | | | |
|
|