| Plan Review Stops For Permit 18071281 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-09-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-27 |
Time |
19:01 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-27 |
Time |
19:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-08-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-27 |
Time |
17:51 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-27 |
Time |
17:29 |
Sent To |
|
|
| Notes |
| 2018-08-27 17:52:13 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC A FIGURE 404.2.4.1(A), A1.3, THE FE APPEARS TO | | | OBSTRUCT MANEUVERING CLEARANCE, PULL SIDE, FOR DOOR | | | A31. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-08-14 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-08-14 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-08-13 |
Time |
17:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-08-01 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-08-01 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-08-01 |
Time |
14:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-09-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-27 |
Time |
19:01 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-30 |
Time |
09:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-08-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-08-28 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-07-27 |
Time |
09:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2018-08-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-08-22 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-08-22 |
Time |
12:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-09-26 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-09-26 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-09-26 |
Time |
15:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-08-26 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
2018-08-26 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-08-28 08:29:56 | 1ST REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PLACE NOTE ON PLAN HARD CAP WATER AND SANITARY FROM | | | BREAK ROOM SINK THAT IS BEING DELETED. PER WPB AMEND TO | | | FBC 107.2.1 | | | | | | 2. A BACKFLOW IS REQUIRED ON THE WATER SUPPLY FOR | | | REFRIGERATOR AND ICEMACHINE. PER FBC PL 608.3 | | | | | | 3. PLEASE CLARIFY IS THE SANITARY AND WATER PIPING | | | BEING SHOWN ON THE PLAN NEW OR EXISTING. WPB AMEND TO | | | FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | 2018-08-27 09:47:01 | REVIEW BY GJOHNSON. COMMENTS TO BE ADDED ON 8/28/18. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2018-09-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-27 |
Time |
19:01 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-27 |
Time |
19:01 |
Sent To |
|
|
| Notes |
| 2018-09-26 15:54:48 | 9/26/18 DIG SIG ON PLUMB SHT OK/GPJ |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2018-08-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-27 |
Time |
17:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-27 |
Time |
17:52 |
Sent To |
|
|
| Notes |
| 2018-08-27 17:53:52 | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | DIGITAL SIGNATURES ARE OK | | | NEW SHEETS SUBMITTED FOR 2ND REVIEW CYCLE NEED | | | VERIFICATION | | 2018-08-22 12:47:56 | MECH SHEETS OK |
|
|