Plan Review Details - Permit 18071238
Plan Review Stops For Permit 18071238
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-08-11 Cont ID  
Sent By cthroop Date 2018-08-11 Time 10:36 Rev Time 0.00
Received By cthroop Date 2018-08-11 Time 10:25 Sent To P
Notes
2018-08-11 10:43:55OPENED MECH. & PLUMB. REVIEWS. CT

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-07-31 Cont ID  
Sent By cthroop Date 2018-07-31 Time 12:46 Rev Time 0.00
Received By cthroop Date 2018-07-31 Time 10:30 Sent To I
Notes
2018-07-31 12:57:33BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE SITE PLAN. IDENTIFY WHICH BLDG. IS AFFECTED
 BY SCOPE OF WORK.
 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED
 WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY
 A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF
 NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE,
 DISTANCES FROM LOT LINES, ...
  
 2. PROVIDE MECHANICAL PLAN FOR UNITS 200/201 AND UNIT
 202.
 FBC -107.3.5.1.4 MECHANICAL MINIMUM PLAN REVIEW
 CRITERIA: SHOW, EXHAUST SYSTEMS, CLOTHES DRYER EXHAUST,
 KITCHEN EQUIPMENT EXHAUST, SPECIALTY EXHAUST SYSTEMS,
 EQUIPMENT, EQUIPMENT LOCATION, MAKE-UP AIR,
 ROOF-MOUNTED EQUIPMENT, DUCT SYSTEMS, VENTILATION,
 COMBUSTION AIR, CHIMNEYS, FIREPLACES AND VENTS,
 APPLIANCES, BOILERS, REFRIGERATION, BATHROOM
 VENTILATION, LABORATORY, DESIGN FLOOD ELEVATION.
  
 3. WHAT IS THE SQUARE FOOTAGE OF UNIT 202? IS ONE WATER
 CLOSET SUFFICIENT?
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED AND MARK VOID.
  
  

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2018-08-17 Cont ID  
Sent By jpearson Date 2018-08-17 Time 10:43 Rev Time 0.00
Received By jpearson Date 2018-08-17 Time 10:43 Sent To M
Notes
2018-08-17 10:43:06NO ELECTRICAL SHOWN ON PLAN. NO ELECTRICAL WORK
 REVIEWED OR APPROVED. ANY ELECTRICAL WORK REQUIRES
 ELECTRICAL PERMIT AND PLANS. WPB FBC 105.1

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2018-08-23 Time   Rev Time 0.00
Received By lmarchan Date 2018-08-08 Time 15:24 Sent To  
Notes
2018-08-09 15:24:35RESUB ROUTED TO CTHROOP

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-07-31 Cont ID  
Sent By cthroop Date 2018-07-31 Time 12:46 Rev Time 0.00
Received By cthroop Date 2018-07-26 Time 11:02 Sent To  
Notes
2018-07-27 11:03:06BLDG MISC 1

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2018-08-23 Cont ID  
Sent By ccole Date 2018-08-23 Time 08:27 Rev Time 0.00
Received By ccole Date 2018-08-23 Time 08:27 Sent To I
Notes
2018-08-11 10:43:17PLEASE SEE MY COMMENTS UNDER BLDG. REVIEW. CT

Review Stop P PLUMBING
Rev No 1 Status N Date 2018-08-17 Cont ID  
Sent By gjohnson Date 2018-08-17 Time 09:21 Rev Time 0.00
Received By gjohnson Date 2018-08-17 Time 09:21 Sent To  
Notes
2018-08-17 09:24:18NO PLUMBING SHOWN ON PLAN, NUMBER OF PLUMBING FIXTURES
 COMPLIES WITH CODE. SEPARATE PLANS AND PERMIT FOR ANY
 PLUMBING WORK.
  
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  
2018-08-11 10:42:49PLEASE SEE MY COMMENTS UNDER BLDG. REVIEW. CT