Plan Review Details - Permit 18071144
Plan Review Stops For Permit 18071144
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-08-27 Cont ID  
Sent By dbattles Date 2018-08-27 Time 11:51 Rev Time 0.00
Received By dbattles Date 2018-08-24 Time 08:49 Sent To  
Notes
2018-08-24 08:50:15FLOOD ZONE X
 OPENING PROTECTION PROVIDED.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2018-10-02 Cont ID  
Sent By jpearson Date 2018-10-02 Time 15:44 Rev Time 0.00
Received By jpearson Date 2018-10-02 Time 15:43 Sent To I
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2018-09-16 Cont ID  
Sent By jpearson Date 2018-09-16 Time 13:36 Rev Time 0.00
Received By jpearson Date 2018-09-16 Time 13:36 Sent To P
Notes
2018-09-16 13:36:11CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS
 COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY
 HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW
 COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS.
  
 1. CORRECTED.
 2. CORRECTED.
 3. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC
 210.8(D); FBC RE E3902.10 (NOT SHOWN ON PLAN OR PANEL
 SCHEDULE.)
 4. CORRECTED.
 5. CORRECTED.
 6. CORRECTED.
 7. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED
 PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING
 ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS
 NEW INSTALLATIONS. FBC RE R314.3, R315.1; WPB FBC
 107.2.1 (CO ALARMS MUST BE WITHIN 10 FEET OF SLEEPING
 ROOMS, THIS IS NOT PROVIDED IN SEVERAL LOCATIONS.
 MASTER BED AND GUEST BEDROOM DO NOT SHOW THE REQUIRED
 ALARMS INSIDE AND OUTSIDE OF ROOM.)
 8. CORRECTED.
 9. CORRECTED.
  
 NEW COMMENT:
  
 10. SINCE THE ELECTRICAL SERVICE IS BEING REPLACED,
 PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH
 PANEL INCLUDING INFORMATION FROM THE POWER COMPANY
 STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR
 THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE
 SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE.
 NEC 110.9, 110.10; FBC RE E3603.3
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED "OLD
 SHEETS".
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-08-17 Cont ID  
Sent By jpearson Date 2018-08-17 Time 10:40 Rev Time 0.00
Received By jpearson Date 2018-08-17 Time 10:40 Sent To  
Notes
2018-08-17 10:40:15CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. AFCI PROTECTION SHOWN IN NOT CODE COMPLIANT. ALL
 BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15-
 AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY
 ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES,
 DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS,
 HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS
 SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND
 POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH
 AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC
 210.8, 210.12; FBC RE E3902
 2. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE
 LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF
 THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE.
 FBC EC C405.1, R404.1
 3. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC
 210.8(D); FBC RE E3902.10
 4. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE
 EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE
 IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2
 5. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED
 CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS,
 AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY
 WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5,
 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902
 6. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF
 SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE,
 WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY
 SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW
 INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230,
 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1,
 E3609.3; WPB FBC 107.2.1
 7. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED
 PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING
 ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS
 NEW INSTALLATIONS. FBC RE R314.3, R315.1; WPB FBC
 107.2.1
 8. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A
 NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14
 9. PROVIDE LOCATION OF ELECTRICAL SERVICE AND
 ELECTRICAL PANELS ON PLAN. WPB FBC 107.2.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD
 SHEETS?.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2018-10-02 Time   Rev Time 0.00
Received By lmarchan Date 2018-09-26 Time 10:36 Sent To  
Notes
2018-09-28 10:36:32RESUB ROUTED TO JPEARSON

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-09-24 Cont ID  
Sent By gjohnson Date 2018-09-24 Time 15:05 Rev Time 0.00
Received By gjohnson Date 2018-09-07 Time 15:33 Sent To  
Notes
2018-09-11 15:33:37RESUB ROUTED TO JPEARSON

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-09-04 Cont ID  
Sent By shill Date 2018-09-04 Time 09:42 Rev Time 0.00
Received By shill Date 2018-07-25 Time 11:39 Sent To  
Notes
2018-07-27 11:39:17R41

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2018-08-08 Cont ID  
Sent By cmontell Date 2018-08-08 Time 13:59 Rev Time 0.00
Received By cmontell Date 2018-08-08 Time 13:56 Sent To  
Notes
2018-08-08 13:58:30NO MECHANICAL PLANS. PER PERMIT APP ONLY DOORS,WINDOWS
 & ELECTRIC
  
 CHRIS MONTELLO
 561-805-6733

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-09-24 Cont ID  
Sent By gjohnson Date 2018-09-24 Time 15:04 Rev Time 0.00
Received By gjohnson Date 2018-09-24 Time 15:04 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-09-04 Cont ID  
Sent By shill Date 2018-09-04 Time 09:41 Rev Time 0.00
Received By jesmith Date 2018-09-04 Time 09:40 Sent To  
Notes
2018-09-07 12:33:38REVIEW COMPLETED BY JERALD SMITH 0017-P
2018-09-04 09:41:371ST REVIEW: FBC 2017 6TH EDITION
  
 PLUMBING COMMENTS: DENIED
  
 1. PROVIDE SANITARY ISOMETRIC DRAWING. PER WPB AMEND TO
 FBC 107.3.5.3(12)
  
 2. HOT WATER SHALL BE SUPPLIED TO PLUMBING FIXTURES AND
 PLUMBING APPLIANCES PER FBC RES 2801.1.
 THERE IS A WATER HEATER BEING REMOVED ON PLAN SHEET
 D100 WHICH APPARENTLY SERVICED ENTIRE HOUSE WITH THE
 EXCEPTION OF THE MASTER BATH AND THERE IS NO
 REPLACEMENT INDICATED ON PLAN SHEET A103. PROVIDE ON
 PLANS INDICATING TYPE AND CAPACITY.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711

Review Stop Z ZONING
Rev No 1 Status N Date 2018-08-10 Cont ID  
Sent By awooten Date 2018-08-10 Time 16:06 Rev Time 0.00
Received By awooten Date 2018-08-10 Time 16:04 Sent To  
Notes
2018-08-10 16:06:29ZONING NOT REQUIRED. INTERIOR RENOVATIONS ONLY,
 REPLACEMENT OF EXTERIOR DOORS AND WINDOWS PER PLANS,