| Plan Review Stops For Permit 18071047 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-09-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-25 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-25 |
Time |
16:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-08-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-25 |
Time |
18:40 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-25 |
Time |
18:40 |
Sent To |
|
|
| Notes |
| 2018-08-25 18:40:44 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. A000 REFERS TO INCORRECT GOVERNING CODES, FS553 - | | | SHOULD BE FBC 2017. PLAN ALSO REFERS TO IMC, 2010 | | | ACCESSIBILITY CODE, IPC, IFC, INTERNATIONAL ENERGY | | | CODE. PLEASE CORRECT ALL. | | | | | | 2. D-A301, IT APPEARS THAT THE FITTING ROOM HOOKS ARE | | | TO COMPLY WITH FBC A 803.5, REACH RANGE 308.2. | | | ARCHITECT'S INTENT IS NOT CLEAR. THE D ELEVATION | | | LABELED "FITTING ROOM" HAS HOOKS AT 4'10", THE ONE | | | LABELED "H.C. FITTING ROOM" HAS HOOKS AT 5'6", BUT THE | | | REQUIREMENT IS BETWEEN 15" AND 48". | | | | | | 3. FBC A 803.4, A301, REVISE BENCH DETAILS TO SHOW | | | COMPLIANCE. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-09-26 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-09-26 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-09-26 |
Time |
11:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-08-10 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-08-10 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-08-10 |
Time |
14:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-07-26 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-07-26 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-07-26 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2018-07-26 10:52:48 | PERMIT # 18071047 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | 1) UPDATE THE CODE LIST TO REFERENCE THE 6TH EDITION OF | | | THE FLORIDA FIRE PREVENTION CODE WHICH CONTAINS THE | | | 2015 EDITION OF BOTH NFPA 1 AND NFPA 101 WITH FLORIDA | | | AMENDMENTS. | | | | | | 2) FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING | | | DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A | | | FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN | | | 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE | | | PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST | | | BE SUBMITTED BY EMAIL ([email protected]) | | | ([email protected]) OR IN WRITING (FAX: 561-804-4774) AND | | | APPROVED BY THE OFFICE OF THE FIRE MARSHAL LOCATED AT | | | 500 NORTH DIXIE HIGHWAY. | | | | | | 3) ENTRY DOORS: THUMB-TURN LOCK TO BE EQUIPPED WITH A | | | LOCK/UNLOCK INDICATOR. | | | | | | 4) PROVIDE 44 INCH WIDE STRIPING (DEMARCATION) IN | | | STOREROOM TO ENSURE EGRESS PATH REQUIREMENTS ARE | | | MAINTAINED AT ALL TIMES. (AS MARKED ON SHEET A103) | | | | | | 5) SUB-PERMITS REQUIRED FOR ALL WORK DONE RELATED TO | | | THE FIRE ALARM AND SPRINKLER SYSTEM. | | | | | | 6) WHERE MUSIC SYSTEMS ARE BEING INSTALLED IN TENANT | | | SPACES: THE SPEAKER SYSTEM WILL NEED TO BE TESTED | | | AGAINST THE FIRE ALARM SYSTEM TO ENSURE THAT THE | | | MINIMUM REQUIRED DECIBEL LEVELS OF THE FIRE ALARM | | | SYSTEM ARE BEING MET. PENDING RESULTS OF FIELD | | | INSPECTION/FIRE ALARM TEST, ADDITIONAL REQUIREMENTS MAY | | | BE NEEDED. | | | | | | | | | SUE ELLEN CALDERON | | | ASSISTANT FIRE MARSHAL | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 804-4751 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-09-28 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-09-28 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-08-30 |
Time |
09:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-08-27 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-08-27 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-07-24 |
Time |
10:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2018-08-14 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-08-14 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-08-14 |
Time |
14:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2018-08-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-08-26 |
Time |
|
Rev Time |
|
| Received By |
gjohnson |
Date |
2018-08-26 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-08-28 06:35:28 | 1ST REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. NO PLUMBING WORK SHOWN ON PLAN SEPARATE PERMIT AND | | | PLANS REQUIRED FOR ANY PLUMBING WORK BEING DONE. | | | | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | 2018-08-27 09:47:47 | REVIEW BY GJOHNSON. COMMENTS TO BE ADDED ON 8/28/18. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2018-09-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-25 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-25 |
Time |
16:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2018-08-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-25 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-25 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2018-08-25 14:02:29 | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. PAGES SUBMITTED ARE NOT DIGITALLY SIGNED. FS481, | | | FS471. | | | | | | THIS COMMENT CAN BE RESOLVED BY PROVIDING DIGITALLY | | | SIGNED AND SEALED PAGES OR BY SUBMITTING A PAPER | | | ORIGINAL AFTER ALL REVIEWS HAVE PASSED. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-09-28 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2018-09-28 |
Time |
16:23 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2018-09-28 |
Time |
16:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-08-06 |
|
|
Cont ID |
|
| Sent By |
ES |
Date |
2018-08-06 |
Time |
15:59 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2018-08-06 |
Time |
15:45 |
Sent To |
|
|
| Notes |
|
|