Plan Review Details - Permit 18070941
| Plan Review Stops For Permit 18070941 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-08-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-08-11 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-08-11 |
Time |
09:22 |
Sent To |
I |
|
| Notes |
| 2018-08-11 09:27:18 | | | | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE ENGINEERING FOR DESIGN PRESSURES. | | | 2. ANCHOR KITS DO NOT PROVIDE ANY UPLIFT PRESSURES. | | | | | | YOU MAY NEED TO REQUEST THE ASSISTANCE OF A DESIGN | | | PROFESSIONAL. | | | | | | FBC 107.3.5.3 ? PROVIDE WIND DESIGN LOADS/DESIGN | | | PRESSURES PURSUANT TO FBC-R301.2. | | | | | | R301.2.1 WIND DESIGN CRITERIA. | | | BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN | | | ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING | | | THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED | | | FROM FIGURE R301.2(4). THE STRUCTURAL PROVISIONS OF | | | THIS CODE FOR WIND LOADS ARE NOT PERMITTED WHERE WIND | | | DESIGN IS REQUIRED AS SPECIFIED IN SECTION R301.2.1.1. | | | WHERE DIFFERENT CONSTRUCTION METHODS AND STRUCTURAL | | | MATERIALS ARE USED FOR VARIOUS PORTIONS OF A BUILDING, | | | THE APPLICABLE REQUIREMENTS OF THIS SECTION FOR EACH | | | PORTION SHALL APPLY. WHERE NOT OTHERWISE SPECIFIED, THE | | | WIND LOADS LISTED IN TABLE R301.2(2) ADJUSTED FOR | | | HEIGHT AND EXPOSURE USING TABLE R301.2(3) SHALL BE USED | | | TO DETERMINE DESIGN LOAD PERFORMANCE REQUIREMENTS FOR | | | WALL COVERINGS, CURTAIN WALLS, ROOF COVERINGS, EXTERIOR | | | WINDOWS, SKYLIGHTS AND EXTERIOR DOORS (OTHER THAN | | | GARAGE DOORS). | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-07-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-07-27 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-07-27 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2018-07-27 16:10:45 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | FOR A PRE-ENGINEERED SHED PROVIDE THE FOLLOWING: | | | | | | 1. PRE-ENGINEERED SHED | | | A. PROVIDE FOUNDATION PLAN. | | | B. PROVIDE PRE-ENGINEERED DESIGN. | | | C. IDENTIFY TYPE OF TIE-DOWN TO FOUNDATION. | | | D. PROVIDE SITE PLAN WITH LOCATION OF PROPOSED SHED. | | | | | | FOR A SITE BUILT SHED PROVIDE THE FOLLOWING: | | | | | | 2. SITE BUILT SHED | | | A. PROVIDE FOUNDATION PLAN ? FOOTINGS/SLAB ON | | | GRADE/REINFORCING | | | B. PROVIDE BUILDING PLANS ? | | | 1. FLOOR | | | 2. WALLS | | | 3. ROOF FRAMING | | | C. WINDOW AND/OR DOOR SCHEDULE WITH ROUGH OPENINGS AND | | | DESIGN WIND LOADS. | | | D. PRODUCT APPROVALS FOR ALL ROOFING, WINDOWS AND/OR | | | DOORS. >720 SQ. FT. | | | E. PROVIDE SITE PLAN WITH SETBACKS FROM PROPERTY LINES. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED AND MARK VOID. | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-08-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-08-11 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-08-08 |
Time |
15:10 |
Sent To |
|
|
| Notes |
| 2018-08-09 15:11:07 | RESUB ROUTED TO CTHROOP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-07-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-07-27 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-07-20 |
Time |
15:36 |
Sent To |
I |
|
| Notes |
| 2018-07-20 15:36:11 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-08-17 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-08-17 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-08-17 |
Time |
11:06 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-07-26 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-07-26 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-07-26 |
Time |
11:52 |
Sent To |
B |
|
| Notes |
|
|
|