Plan Review Details - Permit 18070817
Plan Review Stops For Permit 18070817
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-08-28 Cont ID  
Sent By rmcdouga Date 2018-08-28 Time 11:16 Rev Time 0.00
Received By rmcdouga Date 2018-08-28 Time 11:05 Sent To I
Notes
2018-08-28 12:57:16FBC-R4501.19 FINAL INSPECTION. FINAL ELECTRICAL AND
 BARRIER CODE INSPECTION SHALL BE COMPLETED PRIOR TO
 FILLING THE POOL WITH WATER.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-07-30 Cont ID  
Sent By rmcdouga Date 2018-07-30 Time 10:13 Rev Time 0.00
Received By rmcdouga Date 2018-08-28 Time 10:14 Sent To I
Notes
2018-07-30 10:27:48PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) VALUATION OF POOL ON THE APPLICATION APPEARS TO BE
 UNDER VALUED. SUBMIT A COPY OF THE SIGNED CONTRACT TO
 VERIFY VALUATION. FBC 109.3 BUILDING PERMIT VALUATION.
 FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL, INTERIOR
 FINISH, RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN
 FEES, MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING
 ONLY LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE
 LATEST PUBLISHED DATA OF NATIONAL CONSTRUCTION COST
 ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS
 PUBLISHED BY INTERNATIONAL CODE CONGRESS. FINAL
 BUILDING PERMIT VALUATION SHALL BE SET BY THE BUILDING
 OFFICIAL.
  
 2) FBC-R4501.19 FINAL INSPECTION. FINAL ELECTRICAL AND
 BARRIER CODE INSPECTION SHALL BE COMPLETED PRIOR TO
 FILLING THE POOL WITH WATER.
  
 3) NOTE: A POOL ELECTRICAL SUB-PERMIT IS REQUIRED TO BE
 SUBMITTED BEFORE THE POOL PERMIT WILL BE ISSUED.
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2018-07-26 Cont ID  
Sent By jleahy Date 2018-07-26 Time 15:33 Rev Time 0.00
Received By jleahy Date 2018-07-26 Time 15:33 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2018-07-28 Cont ID  
Sent By tklarge Date 2018-07-28 Time 05:38 Rev Time 0.00
Received By tklarge Date 2018-07-28 Time 05:38 Sent To  
Notes
2018-07-28 05:39:08THERE IS NO GAS ASSOCIATED WITH THIS POOL.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-08-28 Cont ID  
Sent By rmcdouga Date 2018-08-28 Time 12:57 Rev Time 0.00
Received By rmcdouga Date 2018-08-21 Time 14:11 Sent To  
Notes
2018-08-22 14:11:49RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-07-30 Cont ID  
Sent By rmcdouga Date 2018-07-30 Time 10:28 Rev Time 0.00
Received By rmcdouga Date 2018-07-18 Time 14:19 Sent To  
Notes
2018-07-19 14:19:48ROUTED TO ZONING INBOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-08-28 Cont ID  
Sent By tklarge Date 2018-08-28 Time 10:01 Rev Time 0.00
Received By tklarge Date 2018-08-28 Time 06:07 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-07-28 Cont ID  
Sent By tklarge Date 2018-07-28 Time 05:47 Rev Time 0.00
Received By tklarge Date 2018-07-28 Time 05:33 Sent To  
Notes
2018-07-28 05:25:431) SUBMIT TOTAL DYNAMIC HEAD CALCULATIONS FOR THE
 MAXIMUM SYSTEM FLOW. THE MAXIMUM FLOW OF THE PUMP FROM
 ITS PUMP CURVE IS NO LONGER ALLOWED TO BE USED IN
 DETERMINING MAXIMUM SYSTEM FLOW RATE PER ANSI/APSP/ICC
 7 - 2013 SECS. 4.4.9, 4.4.9.1. THE 2013 EDITION
 ADDRESSES FLOW RATE IN GALLONS PER MINUTE (GPM). IT
 REQUIRES THAT MAXIMUM SYSTEM FLOW RATE DOES NOT EXCEED
 THE LISTED MAXIMUM FLOW RATE OF THE SUCTION OUTLET
 FITTING ASSEMBLY (DRAIN COVER).THE TDH CALCULATIONS
 MUST INCLUDE ALL OF THE SYSTEM COMPONENTS IN THE PIPING
 SYSTEM INCLUDING THE FILTER.
  
 2) SUBMIT TWO LEGIBLE COPIES OF THE POOL PUMP CURVE.
 IDENTIFY ON THE PUMP CURVE WHICH CURVE KEY IS SPECIFIC
 TO THE PUMP BEING INSTALLED ON THIS POOL. THIS IS
 NEEDED TO CONFIRM THE MAXIMUM SYSTEM FLOW FROM THE TDH
 CALCULATIONS.
  
 3) THE VALUE LISTED FOR THE POOL ON THE APPLICATION
 APPEARS LOW. SUBMIT A COPY OF A BONA FIDE SIGNED
 CONTRACT FOR THGIS WORK. WPB AMEND. TO FBC SEC.
 107.2.1.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status P Date 2018-07-24 Cont ID  
Sent By mcruz Date 2018-07-24 Time 14:20 Rev Time 0.00
Received By mcruz Date 2018-07-24 Time 13:43 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved