Plan Review Details - Permit 18070766
Plan Review Stops For Permit 18070766
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-07-30 Cont ID  
Sent By rmcdouga Date 2018-07-30 Time 09:04 Rev Time 0.00
Received By rmcdouga Date 2018-07-30 Time 09:01 Sent To I
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-08-24 Cont ID  
Sent By jleahy Date 2018-08-24 Time 07:44 Rev Time 0.00
Received By jleahy Date 2018-08-24 Time 07:44 Sent To I
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2018-07-26 Cont ID  
Sent By jleahy Date 2018-07-26 Time 15:33 Rev Time 0.00
Received By jleahy Date 2018-07-26 Time 15:32 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2018-07-28 Cont ID  
Sent By tklarge Date 2018-07-28 Time 03:09 Rev Time 0.00
Received By tklarge Date 2018-07-28 Time 03:08 Sent To  
Notes
2018-07-28 03:10:11A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT
 THIS TIME. A SEPARATE GAS PERMIT IS REQUIRED FOR A
 CONTRACTOR TO PERFORM THE RELATED WORK. PROVIDE
 COMPLETE PLANS THAT REFLECT THE ENTIRE SCOPE OF GAS
 WORK TO BE DONE. WPB AMEND. TO FBC SEC.107.2.1.
  
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE
 FBC-R, SEC. G2404.3.
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL
 GAS SEC. 301.3.
  
 A SEPARATE PERMIT IS REQUIRED FOR THE GAS INSTALLATION.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-08-24 Cont ID  
Sent By jleahy Date 2018-08-24 Time 07:44 Rev Time 0.00
Received By jleahy Date 2018-08-10 Time 14:43 Sent To  
Notes
2018-08-13 14:43:49RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-07-30 Cont ID  
Sent By rmcdouga Date 2018-07-30 Time 09:05 Rev Time 0.00
Received By rmcdouga Date 2018-07-17 Time 14:28 Sent To  
Notes
2018-07-18 14:28:37ROUTED TO ZONING INBOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-08-20 Cont ID  
Sent By lcrespo Date 2018-08-20 Time 16:08 Rev Time 0.00
Received By lcrespo Date 2018-08-20 Time 16:08 Sent To  
Notes
2018-08-20 16:09:3708/20/18 REVIEWED FOR CODE COMPLIANCE (PLUMBING/POOL)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVE PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-07-28 Cont ID  
Sent By tklarge Date 2018-07-28 Time 03:16 Rev Time 0.00
Received By tklarge Date 2018-07-28 Time 03:10 Sent To  
Notes
2018-07-28 03:16:341) GAS FIRED POOL HEATERS SHALL HAVE A MINIMUM THERMAL
 EFFICIENCY OF 82% PER THE 2017 FBC-ENERGY SEC.
 R403.10.4. THE SUBMITTED SPECS DO NOT SHOW THIS.
 2) SUBMIT TOTAL DYNAMIC HEAD CALCULATIONS FOR THE
 MAXIMUM SYSTEM FLOW. THE MAXIMUM FLOW OF THE PUMP FROM
 ITS PUMP CURVE IS NO LONGER ALLOWED TO BE USED IN
 DETERMINING MAXIMUM SYSTEM FLOW RATE PER ANSI/APSP/ICC
 7 - 2013 SECS. 4.4.9, 4.4.9.1. THE 2013 EDITION
 ADDRESSES FLOW RATE IN GALLONS PER MINUTE (GPM). IT
 REQUIRES THAT MAXIMUM SYSTEM FLOW RATE DOES NOT EXCEED
 THE LISTED MAXIMUM FLOW RATE OF THE SUCTION OUTLET
 FITTING ASSEMBLY (DRAIN COVER).THE TDH CALCULATIONS
 MUST INCLUDE ALL OF THE SYSTEM COMPONENTS IN THE PIPING
 SYSTEM INCLUDING THE FILTER.
 3) SUBMIT TWO LEGIBLE COPIES OF THE POOL PUMP CURVE.
 IDENTIFY ON THE PUMP CURVE WHICH CURVE KEY IS SPECIFIC
 TO THE PUMP BEING INSTALLED ON THIS POOL. THIS IS
 NEEDED TO CONFIRM THE MAXIMUM SYSTEM FLOW FROM THE TDH
 CALCULATIONS.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  

Review Stop Z ZONING
Rev No 3 Status P Date 2018-08-24 Cont ID  
Sent By mcruz Date 2018-08-24 Time 12:22 Rev Time 0.00
Received By mcruz Date 2018-08-24 Time 12:22 Sent To PC
Notes
2018-08-24 12:22:56APPLICANT HAND DELIVERED PERMIT TO PERMIT CLERK.

Review Stop Z ZONING
Rev No 2 Status F Date 2018-08-17 Cont ID  
Sent By mcruz Date 2018-08-17 Time 10:12 Rev Time 0.00
Received By mcruz Date 2018-08-17 Time 10:11 Sent To P
Notes
2018-08-17 10:12:11ZONING REVIEW FAILED, DUE TO THE FOLLOWING:
  
 REPEAT COMMENT-
 1) INDICATE SETBACK FROM POOL EQUIPMENT TO REAR
 PROPERTY LINE. MUST BE AT LEAST 6 FEET.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ
 ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: 561-822-1442
 E-MAIL: [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2018-07-23 Cont ID  
Sent By mcruz Date 2018-07-23 Time 15:28 Rev Time 0.00
Received By mcruz Date 2018-07-23 Time 15:18 Sent To  
Notes
2018-07-23 15:28:48ZONING REVIEW FAILED, DUE TO THE FOLLOWING:
  
 1) INDICATE SETBACK FROM POOL EQUIPMENT TO REAR
 PROPERTY LINE. MUST BE AT LEAST 6 FEET.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ