Plan Review Details - Permit 18070665
| Plan Review Stops For Permit 18070665 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-08-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-08-20 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-08-20 |
Time |
09:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-07-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-07-24 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-07-24 |
Time |
09:19 |
Sent To |
|
|
| Notes |
| 2018-07-24 09:24:29 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE GENERATOR PAD ENGINEERING THAT WAS SUBMITTED | | | REQUIRES THE 16KW GENERATOR TO HAVE A MINIMUM WEIGHT OF | | | 448 POUNDS. THE GENERATOR THAT IS PROPOSED HAS A UNIT | | | WEIGHT OF 409 POUNDS WHICH DOES NOT MEET THE MINIMUM | | | REQUIRED. FBCR-G2404.6 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-07-27 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-07-27 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-07-27 |
Time |
13:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2018-07-27 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-07-27 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-07-27 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2018-07-27 15:46:14 | 07/27/18 REVIEWED FOR CODE COMPLIANCE (PLUMBING/GAS) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVE PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-08-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-08-20 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-08-16 |
Time |
13:29 |
Sent To |
|
|
| Notes |
| 2018-08-17 13:29:59 | RESUB ROUTED TO RMCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-07-27 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-07-27 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-07-16 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2018-07-17 13:40:02 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-07-19 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-07-19 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-07-19 |
Time |
14:12 |
Sent To |
B |
|
| Notes |
|
|
|