| Plan Review Stops For Permit 18070635 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2018-07-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-07-19 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-07-19 |
Time |
09:33 |
Sent To |
|
|
| Notes |
| 2018-07-19 09:58:30 | | | | | | | | | | | | | ***VALUATION ADDD REPAIRS | | | - | | | | | | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1- REVISE INFILL DETAILS A, B, C AND E: | | | A) COORDINATE WOOD STUDS AND CONNECTORS. 2X10 WOOD | | | STUDS CAN NOT BE INSTALLED WITH SIMPSON SP6 CONNECTORS. | | | B) PROVIDE CLEAR SPECIFICATIONS FOR ATTACHMENT OF TOP | | | AND BOTTOM PLATES. TAPCON SIZE IS NOT CLEAR. ARCHITECT | | | OF RECORD TO VERIFY THAT ANCHOR SPACING IS ADEQUATE TO | | | RESIST THE WIND LOADS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-07-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-07-19 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-07-16 |
Time |
16:13 |
Sent To |
I |
|
| Notes |
| 2018-07-17 16:13:59 | REVISION ROUTED TO JGOMEZ |
|
|
|