|
 |
 |
 |
 |
 |
Plan Review Details - Permit 18070507
| Plan Review Stops For Permit 18070507 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2018-08-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-12 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-12 |
Time |
15:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-08-27 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-08-27 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-08-27 |
Time |
16:17 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-08-09 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-08-09 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-08-09 |
Time |
11:59 |
Sent To |
|
|
| Notes |
| 2018-08-09 13:45:55 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND | | | SEALED BY A LICENSED DESIGN PROFESSIONAL OR THE | | | ELECTRICAL CONTRACTOR QUALIFIER. FS 471.003(2)(H); | | | 471.025; WPB FBC 107.2.1, 107.3.5 | | | 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | | 408.4 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD | | | SHEETS?. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-07-17 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-07-17 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-07-17 |
Time |
10:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-09-04 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-09-04 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-08-24 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2018-08-27 11:44:32 | RESUB ROUTED TO JPEARSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-08-13 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-08-13 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-07-12 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2018-08-12 15:28:16 | ON SH DESK, REMOVED FROM BOARD | | | | | | | | | | | 2018-07-13 16:10:29 | B06 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-09-04 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-09-04 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-09-04 |
Time |
09:47 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2018-07-30 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-07-30 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-08-13 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2018-08-13 10:04:05 | IF MECHANICAL WORK IS ENCOUNTERED, A SEPARATE PERMIT IS | | | REQUIRED. | | 2018-07-30 14:44:54 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #18070507 | | | 7/30/18 | | | | | | CODES IN EFFECT: | | | | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE MECHANICAL PLANS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2018-08-13 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-08-13 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-08-13 |
Time |
09:24 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |