| Plan Review Stops For Permit 18070499 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2018-07-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-07-24 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-07-24 |
Time |
08:56 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-09-18 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-09-18 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-09-18 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2018-09-18 12:58:16 | BREAKER IN GENERATOR MAY HAVE TO COMPLY WITH 240.87 | | | JLEAHY |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-08-31 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-08-31 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-08-31 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2018-08-31 15:44:40 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | RISER DIAGRAM DOES NOT SHOW SIZE OF MAIN AT | | | GENERATOR??? 215.5 | | | | | | WIRE SIZES SHOWN ARE ONLY GOOD UP TO 800A???? 240.4(B) | | | | | | WHAT SIZE IS THE TRANSFER SWITCH? 215.5 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-07-19 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-07-19 |
Time |
17:34 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-07-19 |
Time |
17:34 |
Sent To |
I |
|
| Notes |
| 2018-07-19 17:37:59 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PLANS NEED TO BE SIGNED BY ENGINEER CONTRACTOR IS NOT | | | ALLOWED TO SIGN FOR 480 VOLT PROJECTS. 471.003 (J) | | | | | | VALUE IS TOO LOW FOR THIS AMOUNT OF WORK. PLEASE SUBMIT | | | A SIGNED CONTRACT WITH THE SOLID WASTE OR CITY WILL | | | PLACE THE VALUE ON PROJECT. | | | | | | VALUE SHALL INCLUDE ALL MATERIALS AND ALL LABOR. | | | | | | FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING | | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE | | | TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | | VALUATION SHALL BE SET BY THE BUILDING OFFICIA |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-07-26 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-07-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-07-25 |
Time |
10:45 |
Sent To |
I |
|
| Notes |
| 2018-07-26 15:19:16 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | 1) THERE ARE NO INDICATIONS THAT THIS GENERATOR | | | PROVIDES EMERGENCY POWER TO ANY LIFE SAFETY SYSTEM | | | | | | INSTALL AND TEST PER ALL APLLICABLE NFPA CODES. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-09-18 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-09-18 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-09-11 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2018-09-13 10:41:38 | RESUB ROUTED TO JLEAHY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-08-31 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-08-31 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-08-21 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2018-08-22 14:07:59 | RESUB ROUTED TO JLEAHY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-07-30 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-07-30 |
Time |
06:22 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-07-12 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2018-07-13 13:27:38 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2018-07-24 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-07-24 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-07-24 |
Time |
14:05 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-07-18 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-07-18 |
Time |
16:59 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-07-18 |
Time |
16:19 |
Sent To |
B |
|
| Notes |
| 2018-07-18 16:59:34 | REPLACING EXISTING, SAME DIMENSIONS,SAME LOCATION. | | | | | | MAGGIE CRUZ | | | ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: 561-822-1442 | | | E-MAIL: [email protected] |
|
|