Plan Review Details - Permit 18070442
| Plan Review Stops For Permit 18070442 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2018-10-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-10-29 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-10-29 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2018-10-29 08:48:50 | 1201 S FLAGLER | | | |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2018-08-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-27 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-27 |
Time |
10:26 |
Sent To |
|
|
| Notes |
| 2018-08-27 10:31:41 | FOR ADDRESSING, PLEASE CONTACT (PREFERABLY VIA EMAIL): | | | | | | MICHAEL ORIO | | | GIS SUPPORT SPECIALIST | | | [email protected] | | | CITY OF WEST PALM BEACH | | | INFORMATION TECHNOLOGY DEPARTMENT | | | 401 CLEMATIS STREET, WEST PALM BEACH, FLORIDA 33401 | | | P: 561.494.1080 | | | | | | |
|
|
| Review Stop |
AIPP |
ART IN PUBLIC PLACES |
| Rev No |
1 |
Status |
N |
Date |
2018-09-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-01 |
Time |
18:45 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-01 |
Time |
18:45 |
Sent To |
|
|
| Notes |
| 2018-09-01 18:46:19 | PER EMAIL FROM SYBILLE WELTER, AIPP IS NOT REQUIREC | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-10-29 |
|
|
Cont ID |
|
| Sent By |
rgathrig |
Date |
2018-10-29 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
rgathrig |
Date |
2018-10-29 |
Time |
11:25 |
Sent To |
|
|
| Notes |
| 2018-10-29 11:49:32 | 2ND REVIEW PASSED WITH PROVISOS | | | | | | RICHARD GATHRIGHT | | | [email protected] | | | 561-805-6679 | | | | | | 1ST REVIEW BY SAMANTHA HILL | | | 9/4/2018 THAT GENERATED THE FOLLOWING COMMENTS | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. SEE PLUMBING COMMENTS REGARDING ACCESSIBILITY; | | | APPLICABLE FOR BUILDING REVIEW. (PLUMBING APPROVED | | | COMMENT CLOSED REG) | | | | | | 2. SEE FIRE COMMENTS REGARDING FIRE SPRINKLERS; | | | APPLICABLE FOR BUILDING REVIEW. (FIRE APPROVED COMMENT | | | CLOSED REG) | | | | | | 3. SINCE THE PRODUCT APPROVALS ARE SPECIFIED ON THE | | | PLAN, PLEASE PROVIDE: | | | NOA 17?110602 | | | YKK 35H, FL 16554.1 & 16554.2 | | | YKK YES 50 FS, FL 14218.7 | | | (PRODUCT APPROVALS WERE PROVIDED COVER SHEETS PROVIDED | | | BY REVIEWER COMMENT CLOSED OK REG) | | | | | | 4. REVISE PLAN TO STATE TOTAL NUMBER OF PARKING SPACES, | | | TOTAL NUMBER OF ACCESSIBLE SPACES, FBC A 208.2, 502. | | | (THIS COMMENT NOT PROPERLY ADDRESSED, SPACES SHOWN ON | | | ALS1.1 MUST BE RELOCATED FOR THE OFFICE USE TO MEET THE | | | FLORIDA ACCESSIBILITY REQUIREMENT, | | | FAIR HOUSING REQUIREMENTS MUST ALSO BE MET. PROVIDE | | | TOTAL NUMBER OF PARKING SPACES PROVIDED FOR THE COVERED | | | UNITS IN THE BRISTOL AND PROVIDED LOCATIONS FOR THE | | | REQUIRED PARKING REG) | | | | | | 5. CONDENSING UNIT STAND SHOWN ON S4.0; EITHER PROVIDE | | | PRODUCT APPROVAL OR INDICATE THAT YOU WOULD LIKE THIS | | | ITEM DEFERRED, FBC 107. | | | (NOTE ADDED TO SUBMIT NOA FOR APPROVAL, ITEM WILL BE A | | | PROVISO REG) | | | | | | 6. S0.0, S6.1, THIS APPEARS TO BE LOCATED IN EXPOSURE | | | D, FBC B 1609. PLEASE NOTE THE FETCH OF OVER A MILE TO | | | THE SOUTH. IF SEOR DISAGREES, PLEASE SEND JUSTIFICATION | | | VIA EMAIL PRIOR TO RESUBMITTING. (ITEM HAS BEEN ADDED | | | COMMENT CLOSED REG) | | | | | | 7. S0.0 HAS TEXT WHICH IS NOT LEGIBLE (REINFORCED | | | MASONRY), PLEASE CORRECT. (COMMENT ON PLANS DELETED | | | (RESOLVED) COMMENTCLOSED REG) | | | | | | 8. OK (COMMENT MODIFIED IN FIRST REVIEW CLOSED REG) | | | | | | 9. S0.1, S6.1, PAGES INCLUDE REFERENCES TO FBC 2014. | | | PLEASE CHECK ALL PAGES AND UPDATE. (REFERENCES HAVE | | | BEEN UPDATED COMMENT CLOSED REG) | | | | | | 10. S0.1, ROOF PRESSURES APPEAR TOO LOW FOR A FLAT ROOF | | | (?38.5, ?67.1, ?67.1). PRESSURES ARE FOR 20SF. AT THIS | | | TIME I DO NOT KNOW THE FASTENING PROPOSED FOR THE | | | PITCHED AND FLAT ROOFS, BUT IT APPEARS THAT PRESSURES | | | FOR 10 SF ARE REQUIRED. | | | (ROOF PRESSURES HAVE BEEN REVISED COMMENT CLOSED REG) | | | | | | 11. CLARIFY PARAPET HEIGHT RELATIVE TO ROOF SURFACE. | | | PARAPET IS TO BE 3? OR GREATER TO UTILIZE ZONE 2 | | | PRESSURES IN ZONE 3, FBC B 1609, ASCE7?10. (ROOF | | | PRESSURES HAVE BEEN REVISED COMMENT CLOSED REG) | | | | | | 12. 6?S3.2 SHOWS WOOD TRUSSES, CDX PLYWOOD. SEE FBC B | | | 603 (COMBUSTIBLES IN TYPE I & II BUILDINGS), REVISE | | | PLAN TO SHOW COMPLIANCE (FRT OR STATE APPLICABLE | | | EXCEPTION); CHECK ALL DETAILS FOR COMBUSTIBLES. | | | (DETAILS 3 & 4 PG S3.2 STILL SAY CDX. THE REFERENCE ON | | | THE ARCHITECTURAL SUCH AS DETAIL 4 ON A4.0.1 DOES NOT | | | SAY FIRE RETARDANT LUMBER AS REQUIRED FOR A TYPE IIB AS | | | STATED ON ALS1.1. THESE CORRECTIONS CAN BE A PROVISO | | | REG) | | | | | | 13. PROVIDE A SITE PLAN WHICH SHOWS COMPLIANCE WITH FBC | | | B TABLES 602, 705.8 (IN PARTICULAR, THE DISTANCE FROM | | | PROPOSED STRUCTURE TO THE SOUTH PROPERTY LINE).(SITE | | | PLAN PROVIDE GC-001 AND SURVEY PROVIDE IN SUBMITTAL | | | 18100459 COMMENT CLOSED REG) | | | | | | 14. FBC B 107.2.5, PROVIDE A PLAN WHICH SHOWS LOCATION | | | OF STRUCTURE RELATIVE TO THE FLOOD ZONE LINES. THIS | | | PARCEL IS AFFECTED BY BOTH THE 6? AND 7? NAVD88 FLOOD | | | ZONES. ALTERNATIVELY, P | | | PLEASE ACKNOWLEDGE ON THE PLANS THAT THIS IS LOCATED IN | | | SFHA 7? NAVD88. (SURVEY PROVIDE IN SUBMITTAL 18100459 | | | THAT DEPICTS LOCATION OF BUILDING IN BOTH THE 6?AND 7? | | | NAVD88 FLOOD ZONES COMMENT CLOSED REG) | | | | | | 15. IF LOCATED IN A SFHA, FBC B 107.3.5.1.1(1), PROVIDE | | | A "CONSTRUCTION DOCUMENTS" ELEVATION CERTIFICATE. (AN | | | EC WAS PROVIDED WITH SURVEY PROVIDE IN SUBMITTAL | | | 18100459 THAT DEPICTS LOCATION OF BUILDING IN BOTH THE | | | 6?AND 7? NAVD88 FLOOD ZONES. | | | EC SUBMITTED WAS NOT CORRECT, EC WAS UNDER CONSTRUCTION | | | AND ONLY LOCATED TOP OF FOOTERS IT DID NOT KNOWLEDGE | | | PROPOSED FLOOR ELEVATION.EC ALSO HAD NOTATION OF FLOOD | | | VENTS. RICHARD DEAN OF DEAN SURVEYING WAS CONTACTED | | | CONCERNING THE FLOOD VENTS AND NOT HAVING A PROPOSED | | | EC. | | | HE STATED HE USED THE GARAGE DOOR OPENINGS AS FLOOD | | | OPENINGS. MR. DEAN SAID HE WOULD PROVIDE A PROPER | | | PROPOSED EC AND PROVIDE AN UNDER CONSTRUCTION EC | | | SHOWING FLOOR ELEVATION. THE EC DATED 10/01/18 HE SAID | | | IS NOT CORRECT AND HE WILL VOID THAT DOCUMENT. R DEAN | | | SAID HE WOULD HAVE THE CORRECTED EC BY 11/02/18. | | | COMMENT NOT CLOSED HOWEVER IT WILL BE A PROVISO REG) | | | | | | 16. FBC B 107.2.5, REVISE ARCHITECTURAL AND/OR | | | STRUCTURAL PLANS TO INCLUDE PROPOSED ELEVATION. C5.00 | | | APPEARS TO PROPOSE 10.52 NGVD29. THIS APPEARS TO COMPLY | | | WITH THE REQUIREMENT OF 9? NAVD88. ON A AND/OR SSHEETS, | | | PLEASE SPECIFY IN NAVD88 TO BE CONSISTENT WITH THE | | | FLOOD INSURANCE RATE MAPS OR SPECIFY CONVERSION. (FLOOR | | | ELEVATIONS WERE ADDED AND SURVEYOR WILL PROVIDE SURVEY | | | TO SUPPORT SUCH COMMENT CLOSED REG) | | | | | | 17. FBC B 1612, IF ANY PORTION OF THE PROPOSED | | | STRUCTURE IS LOCATED IN THE SPECIAL FLOOD HAZARD | | | AREA,DESIGN FLOOD ELEVATION IS BFE + 2? FREEBOARD.(THE | | | ENTIRE BUILDING IS AT ELEVATION 9.00 NAVD88 COMMENT | | | CLOSED REG) | | | | | | 18. ENERGY CALCS REQURIED, FBC EC C401. (ENERGY CALCS | | | SUBMITTED COMMENT CLOSED REG) | | | | | | 19. THIS PERMIT WILL BE ISSUED WITH PROVISO: | | | A. PRIOR TO CONCRETE POUR, A "BUILDING UNDER | | | CONSTRUCTION" ELEVATION CERTIFICATE IS REQUIRED. EC | | | THAT HAS BEEN SUBMITTED NEEDS CORRECTION. CORRECT EC | | | MAY BE SENT VIA EMAIL FOR PRELIMINARY REVIEW. | | | AN UNDER CONSTRUCTION EC IS REQUIRED TO ESTABLISH FLOOR | | | HEIGHT. PRIOR TO FINAL INSPECTION BUT AFTER ALL | | | MECHANICAL EQUIPMENT HAS BEEN INSTALLED AND FINAL | | | GRADES COMPLETED, | | | A "FINISHED CONSTRUCTION" ELEVATION CERTIFICATE WILL BE | | | REQUIRED. THIS MAY BE SENT VIA EMAIL FOR PRELIMINARY | | | REVIEW. | | | B. DEFERRED SUBMITTALS REQUESTED BY ARCHITECT ? | | | COMPONENT & CLADDING PRODUCT APPROVALS REVIEWED BY | | | DESIGNER OF | | | RECORD ARE TO BE SUBMITTED TO THE BUILDING DIVISION, | | | REVIEWED AND ISSUED PRIOR TO | | | INSTALLATION. CONFIRM COMPLIANCE WITH PRESSURES | | | SPECIFIED BY SEOR PRIOR TO SUBMITTAL. | | | IF PRODUCT APPROVAL OFFERS OPTIONS, INDICATE OPTION | | | PROPOSED, ESPECIALLY IF NOT ALL | | | OPTIONS COMPLY WITH MINIMUM DESIGN PRESSURES. | | | C. SEPARATE PERMITS (APPLICATIONS, PLANS, AND FEES) ARE | | | REQUIRED FOR | | | THE FOLLOWING ITEMS AS APPLICABLE: | | | LIGHT POLES/SITE LIGHTING | | | FIRE ALARM | | | FIRE SPRINKLER | | | LOW VOLTAGE | | | ACCESS CONTROL | | | LANDSCAPING | | | IRRIGATION | | | ALL OTHER ITEMS OTHER THAN BMEP | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-08-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-27 |
Time |
12:22 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-25 |
Time |
19:33 |
Sent To |
|
|
| Notes |
| 2018-08-27 12:22:47 | ****CORRECTIONS**** | | | REVISED 9/4/18 (REMOVED COMMENT #8) | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. SEE PLUMBING COMMENTS REGARDING ACCESSIBILITY; | | | APPLICABLE FOR BUILDING REVIEW. | | | | | | 2. SEE FIRE COMMENTS REGARDING FIRE SPRINKLERS; | | | APPLICABLE FOR BUILDING REVIEW. | | | | | | 3. SINCE THE PRODUCT APPROVALS ARE SPECIFIED ON THE | | | PLAN, PLEASE PROVIDE: | | | | | | NOA 17-8080.06 | | | YKK 35H, FL 16554.1 & 16554.2 | | | YKK YES 50 FS, FL 14218.7 | | | | | | 4. REVISE PLAN TO STATE TOTAL NUMBER OF PARKING SPACES, | | | TOTAL NUMBER OF ACCESSIBLE SPACES, FBC A 208.2, 502. | | | | | | 5. CONDENSING UNIT STAND SHOWN ON S4.0; EITHER PROVIDE | | | PRODUCT APPROVAL OR INDICATE THAT YOU WOULD LIKE THIS | | | ITEM DEFERRED, FBC 107. | | | | | | 6. S0.0, S6.1, THIS APPEARS TO BE LOCATED IN EXPOSURE | | | D, FBC B 1609. PLEASE NOTE THE FETCH OF OVER A MILE TO | | | THE SOUTH. IF SEOR DISAGREES, PLEASE SEND JUSTIFICATION | | | VIA EMAIL PRIOR TO RESUBMITTING. | | | | | | 7. S0.0 HAS TEXT WHICH IS NOT LEGIBLE (REINFORCED | | | MASONRY), PLEASE CORRECT. | | | | | | 8. OK | | | | | | 9. S0.1, S6.1, PAGES INCLUDE REFERENCES TO FBC 2014. | | | PLEASE CHECK ALL PAGES AND UPDATE. | | | | | | 10. S0.1, ROOF PRESSURES APPEAR TOO LOW FOR A FLAT ROOF | | | (-38.5, -67.1, -67.1). PRESSURES ARE FOR 20SF. AT THIS | | | TIME I DO NOT KNOW THE FASTENING PROPOSED FOR THE | | | PITCHED AND FLAT ROOFS, BUT IT APPEARS THAT PRESSURES | | | FOR 10 SF ARE REQUIRED. | | | | | | 11. CLARIFY PARAPET HEIGHT RELATIVE TO ROOF SURFACE. | | | PARAPET IS TO BE 3' OR GREATER TO UTILIZE ZONE 2 | | | PRESSURES IN ZONE 3, FBC B 1609, ASCE7-10. | | | | | | 12. 6-S3.2 SHOWS WOOD TRUSSES, CDX PLYWOOD. SEE FBC B | | | 603 (COMBUSTIBLES IN TYPE I & II BUILDINGS), REVISE | | | PLAN TO SHOW COMPLIANCE (FRT OR STATE APPLICABLE | | | EXCEPTION); CHECK ALL DETAILS FOR COMBUSTIBLES. | | | | | | 13. PROVIDE A SITE PLAN WHICH SHOWS COMPLIANCE WITH FBC | | | B TABLES 602, 705.8 (IN PARTICULAR, THE DISTANCE FROM | | | PROPOSED STRUCTURE TO THE SOUTH PROPERTY LINE). | | | | | | 14. FBC B 107.2.5, PROVIDE A PLAN WHICH SHOWS LOCATION | | | OF STRUCTURE RELATIVE TO THE FLOOD ZONE LINES. THIS | | | PARCEL IS AFFECTED BY BOTH THE 6' AND 7' NAVD88 FLOOD | | | ZONES. ALTERNATIVELY, PLEASE ACKNOWLEDGE ON THE PLANS | | | THAT THIS IS LOCATED IN SFHA 7' NAVD88. | | | | | | 15. IF LOCATED IN A SFHA, FBC B 107.3.5.1.1(1), PROVIDE | | | A "CONSTRUCTION DOCUMENTS" ELEVATION CERTIFICATE. | | | | | | 16. FBC B 107.2.5, REVISE ARCHITECTURAL AND/OR | | | STRUCTURAL PLANS TO INCLUDE PROPOSED ELEVATION. C5.00 | | | APPEARS TO PROPOSE 10.52 NGVD29. THIS APPEARS TO COMPLY | | | WITH THE REQUIREMENT OF 9' NAVD88. ON A AND/OR S | | | SHEETS, PLEASE SPECIFY IN NAVD88 TO BE CONSISTENT WITH | | | THE FLOOD INSURANCE RATE MAPS OR SPECIFY CONVERSION. | | | | | | 17. FBC B 1612, IF ANY PORTION OF THE PROPOSED | | | STRUCTURE IS LOCATED IN THE SPECIAL FLOOD HAZARD AREA, | | | DESIGN FLOOD ELEVATION IS BFE + 2' FREEBOARD. | | | | | | 18. ENERGY CALCS REQURIED, FBC EC C401. | | | | | | 19. THIS PERMIT WILL BE ISSUED WITH PROVISO: | | | | | | A. PRIOR TO CONCRETE POUR, A "BUILDING UNDER | | | CONSTRUCTION" ELEVATION CERTIFICATE WILL BE REQUIRED. | | | THIS MAY BE SENT VIA EMAIL FOR PRELIMINARY REVIEW. | | | PRIOR TO FINAL INSPECTION BUT AFTER ALL MECHANICAL | | | EQUIPMENT HAS BEEN INSTALLED AND FINAL GRADES | | | COMPLETED, A "FINISHED CONSTRUCTION" ELEVATION | | | CERTIFICATE WILL BE REQUIRED. THIS MAY BE SENT VIA | | | EMAIL FOR PRELIMINARY REVIEW. | | | | | | B. DEFERRED SUBMITTALS REQUESTED BY ARCHITECT - | | | COMPONENT & CLADDING PRODUCT APPROVALS REVIEWED BY | | | DESIGNER OF RECORD ARE TO BE SUBMITTED TO THE BUILDING | | | DIVISION, REVIEWED AND ISSUED PRIOR TO INSTALLATION. | | | CONFIRM COMPLIANCE WITH PRESSURES SPECIFIED BY SEOR | | | PRIOR TO SUBMITTAL. IF PRODUCT APPROVAL OFFERS OPTIONS, | | | INDICATE OPTION PROPOSED, ESPECIALLY IF NOT ALL OPTIONS | | | COMPLY WITH MINIMUM DESIGN PRESSURES. | | | | | | C. SEPARATE PERMITS (APPLICATIONS, PLANS, AND FEES) ARE | | | REQUIRED FOR THE FOLLOWING ITEMS AS APPLICABLE: | | | LIGHT POLES/SITE LIGHTING | | | FIRE ALARM | | | FIRE SPRINKLER | | | LOW VOLTAGE | | | ACCESS | | | LANDSCAPING | | | IRRIGATION | | | ALL OTHER ITEMS OTHER THAN BMEP | | | | | | D. AIPP COMPLIANCE MAY BE REQUIRED; VERIFICATION | | | REQUIRED PRIOR TO C.O. | | | | | | ******************************* | | | INTERNAL USE ONLY: | | | USC-404 321 - NEW: PARKING GARAGE | | | SQUARE FEET - 19,924 | | | | | | CONSTRUCTION TYPE: IIB | | | | | | FLOORS: 1 | | | BEDROOMS: | | | ROOMS: | | | SQ FT LIVABLE: 19924 | | | SQ FT FOOTPRINT: 19924 | | | SQ FT ROOF: 19924 | | | | | | SETBACKS FRONT (USE THIS TO ENTER VERTICAL DATUM IF | | | KNOWN): | | | SETBACKS BACK (USE THIS TO ENTER FIRST FLOOR IF KNOWN): | | | XX.XX | | | SETBACKS LEFT (USE THIS TO ENTER SECOND FLOOR IF KNOWN: | | | XX.XX | | | OCC LOAD: | | | PROP USE: APARTMENT | | | SPRINKLER SYS? Y | | | SPRK REQ'D? Y | | | BATHRMS: | | | | | | BLDG CODE: FL 2017 | | | OCC CLASS: 6TH ED S-1 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-10-10 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-10-10 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-10-10 |
Time |
12:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-08-13 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-08-13 |
Time |
17:03 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-08-13 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2018-08-13 16:59:20 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) PANEL "A" IS FEEDING COMMUNITY CENTER, PLEASE SHOW | | | LOCATION. | | | | | | 2) AIC RATINGS FOR THE SERVICE IS REQUIRED SHOW | | | CALCULATIONS | | | | | | PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE | | | AVAILABLE SHORT CIRCUIT CURRENT IS FOR THE SERVICE TO | | | CONFIRM THE STATED AIC RATING OF THE SERVICE EQUIPMENT | | | AND DOWNSTREAM | | | PANELS IS ADEQUATE. NEC 110.9, 110.10 | | | | | | 3) MAIN IS 1200A NEEDS TO COMPLY WITH 240.87 | | | | | | 240.87 ARC ENERGY REDUCTION | | | WHERE THE HIGHEST CONTINUOUS CURRENT TRIP SETTING FOR | | | WHICH THE ACTUAL OVERCURRENT DEVICE INSTALLED IN A | | | CIRCUIT BREAKER IS RATED | | | OR CAN BE ADJUSTED IS 1200 A OR HIGHER, 240.87(A) AND | | | (B) SHALL APPLY. | | | | | | (A) DOCUMENTATION. DOCUMENTATION SHALL BE AVAILABLE TO | | | THOSE AUTHORIZED TO DESIGN, INSTA LL, OPERATE, OR | | | INSPECT THE INSTALLATION | | | AS TO THE LOCATION OF THE CIRCUIT BREAKER(S) | | | . | | | (B) METHOD TO REDUCE CLEARING TIME. ONE OF THE | | | FOLLOWING OR APPROVED EQUIVALENT MEANS SH ALL BE | | | PROVIDED: | | | (1) ZONE-SELECTIVE INTERLOCKING | | | (2) DIFFERENTIAL RELAYING | | | (3) ENERGY-REDUCING MAINTENANCE SWITCHING WITH LOCAL | | | STATUS INDICATOR | | | (4) ENERGY-REDUCING ACTIVE ARC FLASH MITIGATION SYSTEM | | | (5) AN APPROVED EQUIVALENT MEANS |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2018-10-24 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2018-10-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2018-10-24 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2018-08-20 |
|
|
Cont ID |
|
| Sent By |
Mgonzale |
Date |
2018-08-20 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2018-08-20 |
Time |
|
Sent To |
I |
|
| Notes |
| 2018-08-20 10:54:01 | APPLICANT MUST POST A PERFORMANCE BOND FOR ENGINEERING | | | SERVICES EROSION CONTROL & LAND STABILIZATION BOND | | | (ORDINANCE 4060-07) | | | | | | BOND SHALL BE INCLUSIVE OF 110% OF ENGINEER'S OPINION | | | OF COST TO RESTORE SITE TO STABILIZED SODDED GRADE, | | | GOOD FOR A PERIOD OF 1 YEAR. | | | | | | TO: CITY OF WEST PALM BEACH, A MUNICIPAL CORPORATION OF | | | THE STATE OF FLORIDA, HAVING AN ADDRESS OF 401 CLEMATIS | | | STREET, WEST PALM BEACH, FLORIDA, 33402 | | | | | | UPON SUCCESFULLY PASSING 1ST VERTICAL INSPECTION THE | | | CONTRACTOR MAY REQUEST THE BOND TO BE TERMINATED. | | | | | | FOR MORE INFORMATION YOU MAY USE THE PERFORMANCE BOND | | | FORM ON OUR WEB PAGE OR SUBMIT EQUAL INTRUMENT DIRECTLY | | | TO: | | | | | | MANNY GONZALEZ | | | SENIOR ENGINEERING PROJECT COORDINATOR | | | PUBLIC WORKS DEPARTMENT \ ENGINEERING SERVICES | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 818-1322 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | EMAIL: [email protected] | | | HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS | | | /FORMS,-PERMITS-APPLICATIONS | | | | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-09-27 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-09-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-09-26 |
Time |
15:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2018-07-18 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-07-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-07-13 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2018-07-17 17:17:50 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) SHEET ALS 1 - THERE IS NO INDICATIONS OF REVIEW | | | AND/OR COMPLIANCE WITH ANY FIRE CODE. | | | | | | PLEASE REVIEW, ENSURE COMPLIANCE AND PROVIDE AN | | | APPLICABLE NOTE TO INCLUDE THE 6TH EDITION OF THE | | | FLORIDA FIRE PREVENTION CODE AND NFPA 88A, STANDARD FOR | | | PARKING STRUCTURES, 2015 EDITION. | | | | | | | | | | | | 2) SHEET ALS 1 - UNDER THE REQUIRED MEANS OF EGRESS | | | THERE IS TWO BUSINESS INDICATORS SHOWING NUMBER OF | | | EGRESSES. ONE INDICATES 2 EXITS HOWEVER THE DRAWING | | | SHOWS ONE EXIT. | | | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | | | | | | | | 3) SHEET ALS 1 - THERE IS AN INDICATION OF THIS STORAGE | | | OCCUPANCY AS LOW HAZARD. THIS IS A PARKING GARAGE AND | | | IS CLASSIFIED AND AN ORDINARY HAZARD. | | | | | | PER NFPA 101, CHAPTER 42, STORAGE OCCUPANCIES | | | | | | 42.8.1.5 CLASSIFICATION OF HAZARD OF CONTENTS. PARKING | | | STRUCTURES USED ONLY FOR THE STORAGE OF VEHICLES SHALL | | | BE CLASSIFIED | | | AS ORDINARY HAZARD IN ACCORDANCE WITH SECTION 6.2. | | | | | | PLEASE REVIEW AND CORRECT OR JUSTIFY WITH SPECIFIC CODE | | | REFERENCES. | | | | | | | | | | | | 4) THERE ARE INDICATIONS THAT THIS IS A FULLY SPRINKLED | | | BUILDING. THERE ARE NO INDICATIONS OR DOCUMENTS IN | | | COMPLAINCE WITH THE REQUIREMENTS FAC 61 G. | | | | | | PER FLORIDA ADMINISTRATIVE CODE SECTION 61G15-32.004, | | | FIRE PROTECTION ENGINEERING DOCUMENTS SHALL INCLUDE THE | | | POINT OF SERVICE FOR THE WATER SUPPLY, A LIST OF | | | APPLICABLE NFPA STANDARDS APPLICABLE TO THE PROJECT, | | | CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | | AREA, SUPPRESSION SYSTEM TYPE, DESIGN DENSITIES, WATER | | | SUPPLY DATA (FIRE PUMP DATA, HYDRANT FLOW TEST DATA) | | | AND ANY PERFORMANCE BASED INFORMATION SUCH AS | | | PRE-ENGINEERED SYSTEMS. | | | | | | 61G15-32.003 COMMON REQUIREMENTS TO ALL FIRE PROTECTION | | | ENGINEERING | | | DOCUMENTS. | | | (1) THE FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS | | | SHALL PROVIDE THE ENGINEERING REQUIREMENTS TO BE USED | | | IN THE PREPARATION OF THE FIRE PROTECTION SYSTEM LAYOUT | | | DOCUMENTS AND TO INDICATE THE NATURE AND SCOPE OF THE | | | WORK, AND TO DESCRIBE, DETAIL, DIMENSION, LABEL AND | | | DEFINE THE FIRE PROTECTION COMPONENTS, SYSTEM(S), | | | MATERIALS, ASSEMBLIES, EQUIPMENT AND ITS STRUCTURAL AND | | | UTILITY SUPPORT SYSTEM(S), INSOFAR AS THEY INVOLVE THE | | | SAFEGUARDING OF LIFE, HEALTH OR PROPERTY. | | | (2) THE FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS | | | SHALL SPECIFY THE APPLICABLE REQUIREMENTS FOR THE | | | ACCEPTANCE TESTING OF THE FIRE PROTECTION SYSTEM AND | | | COMPONENTS, WHICH SHALL BE BASED UPON APPLICABLE CODES | | | AND STANDARDS, WHERE AVAILABLE. | | | (3) THE OCCUPANCY OF THE AREA OR DESCRIPTION OF A | | | SPECIFIC HAZARD BEING PROTECTED BY THE FIRE PROTECTION | | | SYSTEM(S) SHALL BE SHOWN ON THE FIRE PROTECTION SYSTEM | | | ENGINEERING DOCUMENTS. | | | (4) THE APPLICABLE CODE AND STANDARD TO BE USED IN THE | | | PREPARATION OF THE FIRE PROTECTION SYSTEM LAYOUT | | | DOCUMENTS SHALL BE SHOWN ON THE FIRE PROTECTION SYSTEM | | | ENGINEERING DOCUMENTS. WHEN CODES AND STANDARDS ARE NOT | | | AVAILABLE OR APPLICABLE, AND SAID LAYOUT DOCUMENTS ARE | | | TO BE BASED ON ENGINEERING JUDGMENT, ANY REASONS AND | | | ASSUMPTIONS MADE TO DEVELOP THE FIRE PROTECTION CONCEPT | | | SHALL BE IDENTIFIED ON THE FIRE PROTECTION SYSTEM | | | ENGINEERING DOCUMENTS. | | | (5) STRUCTURAL SUPPORT AND STRUCTURAL OPENINGS REQUIRED | | | BY THE FIRE PROTECTION SYSTEM SHALL BE SHOWN ON THE | | | FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS AND SHALL | | | BE REFERENCED ON STRUCTURAL ENGINEERING DOCUMENTS. | | | (6) WHEN LAYOUT DOCUMENTS CONTAIN MATERIAL DEVIATION | | | FROM THE ENGINEER OF RECORD'S FIRE PROTECTION SYSTEM | | | ENGINEERING DOCUMENT, SUCH LAYOUT DOCUMENTS ARE NOT | | | COMPLIANT UNLESS THEY ARE ACCOMPANIED BY REVISED | | | ENGINEERING DOCUMENTS MADE AND SEALED BY THE ENGINEER | | | OF RECORD FOR THE FIRE PROTECTION SYSTEM. | | | (7) REQUIREMENTS FOR ACTIVATION CONTROL SYSTEMS, | | | SEQUENCE, OPERATING PARAMETERS, INTERLOCKS, SAFETY | | | RELATED DEVICES, INDICATORS AND ALARMS, SHALL BE SHOWN | | | ON THE FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS, | | | UNLESS SHOWN ON OTHER RELATED DOCUMENTS. | | | (8) ANY INFORMATION DEEMED APPROPRIATE BY THE ENGINEER | | | OF RECORD TO ASSIST THE AUTHORITY HAVING JURISDICTION | | | IN UNDERSTANDING THE OWNER?S INTENDED USE AND PROPOSED | | | PROTECTION OF THE BUILDING OR FACILITY AND TO PROVIDE | | | SUFFICIENT DIRECTION TO THE INSTALLATION CONTRACTOR OR | | | OTHER INTERESTED PARTIES REGARDING THE LAYOUT OF THE | | | SYSTEM(S), SHALL BE INCLUDED IN THE FIRE PROTECTION | | | SYSTEM ENGINEERING DOCUMENTS. | | | SPECIFIC AUTHORITY 471.008, 471.033(2), FS | | | LAW IMPLEMENTED 471.005(7), 471.033(2), FS | | | HISTORY?NEW 5-19-93, FORMERLY 21H-32.003, AMENDED | | | 4-2-2000, 6-26-01 | | | | | | 61G15-32.004 DESIGN OF WATER BASED FIRE PROTECTION | | | SYSTEMS. | | | (1) WATER BASED FIRE PROTECTION SYSTEMS INCLUDE, BUT | | | ARE NOT LIMITED TO, AUTOMATIC SPRINKLER SYSTEMS OF WET, | | | DRY, FINE WATER SPRAY (MIST), MANUAL, AND DELUGE VALVE | | | CONTROLLED TYPES, PUMPING SYSTEMS, STANDPIPES, FIRE | | | WATER MAINS AND DEDICATED FIRE PROTECTION WATER | | | SOURCES. | | | (2) TO ENSURE MINIMUM DESIGN QUALITY IN FIRE PROTECTION | | | SYSTEM ENGINEERING DOCUMENTS, SAID DOCUMENTS SHALL | | | INCLUDE AS A MINIMUM THE FOLLOWING INFORMATION WHEN | | | APPLICABLE: | | | (A) THE POINT OF SERVICE FOR THE FIRE PROTECTION WATER | | | SUPPLY AS DEFINED BY 633.021(18) F.S. | | | (B) APPLICABLE NFPA STANDARD TO BE APPLIED, OR IN THE | | | CASE WHERE NO SUCH STANDARD EXISTS, THE ENGINEERING | | | STUDY, JUDGMENTS, AND/OR PERFORMANCE BASED ANALYSIS AND | | | CONCLUSIONS. | | | (C) CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | | AREA. | | | (D) DESIGN APPROACH, WHICH INCLUDES SYSTEM TYPE, | | | DENSITIES, DEVICE TEMPERATURE RATING, AND SPACING FOR | | | EACH SEPARATE 42 HAZARD OCCUPANCY. | | | (E) CHARACTERISTICS OF WATER SUPPLY TO BE USED, SUCH AS | | | MAIN SIZE AND LOCATION, WHETHER IT IS DEAD-END OR | | | CIRCULATING; AND IF DEAD-END, THE DISTANCE TO THE | | | NEAREST CIRCULATING MAIN, AS WELL AS ITS MINIMUM | | | DURATION AND RELIABILITY FOR THE MOST HYDRAULICALLY | | | DEMANDING DESIGN AREA. | | | (F) WHEN PRIVATE OR PUBLIC WATER SUPPLIES ARE USED, THE | | | FLOW TEST DATA, INCLUDING DATE AND TIME OF TEST, WHO | | | CONDUCTED TEST OR SUPPLIED INFORMATION, TEST ELEVATION, | | | STATIC GAUGE PRESSURE AT NO FLOW, FLOW RATE WITH | | | RESIDUAL GAUGE PRESSURE, HYDRANT BUTT COEFFICIENT, AND | | | LOCATION OF TEST IN RELATION TO THE HYDRAULIC POINT OF | | | SERVICE. | | | (G) VALVING AND ALARM REQUIREMENTS TO MINIMIZE | | | POTENTIAL FOR IMPAIRMENTS AND UNRECOGNIZED FLOW OF | | | WATER. | | | (H) MICROBIAL INDUCED CORROSION (MIC). THE ENGINEER OF | | | RECORD SHALL MAKE REASONABLE EFFORTS TO IDENTIFY WATER | | | SUPPLIES THAT COULD LEAD TO MICROBIAL INDUCED CORROSION | | | (MIC). SUCH EFFORTS MAY CONSIST OF DISCUSSIONS WITH THE | | | LOCAL WATER PURVEYOR AND/OR FIRE OFFICIAL, FAMILIARITY | | | WITH CONDITIONS IN THE LOCAL AREA, OR LABORATORY | | | TESTING OF WATER SUPPLIES. WHEN CONDITIONS ARE FOUND | | | THAT MAY RESULT IN MIC CONTAMINATION OF THE FIRE | | | PROTECTION PIPING, THE ENGINEER SHALL DESIGN CORRECTIVE | | | MEASURES. | | | (I) BACKFLOW PREVENTION AND METERING SPECIFICATIONS AND | | | DETAILS TO MEET LOCAL WATER PURVEYOR REQUIREMENTS | | | INCLUDING MAXIMUM ALLOWABLE PRESSURE DROP. | | | (J) QUALITY AND PERFORMANCE SPECIFICATIONS OF ALL YARD | | | AND INTERIOR FIRE PROTECTION COMPONENTS. | | | (3) CONTRACTOR SUBMITTALS WHICH DEVIATE FROM THE ABOVE | | | MINIMUM DESIGN PARAMETERS SHALL BE CONSIDERED MATERIAL | | | DEVIATIONS AND REQUIRE SUPPLEMENTAL ENGINEERING | | | APPROVAL AND DOCUMENTATION. | | | (4) IN THE EVENT THE ENGINEER OF RECORD PROVIDES MORE | | | INFORMATION AND DIRECTION THAN IS ESTABLISHED ABOVE, HE | | | OR SHE SHALL BE HELD RESPONSIBLE FOR THE TECHNICAL | | | ACCURACY OF THE WORK IN ACCORDANCE WITH APPLICABLE | | | CODES, STANDARDS, AND SOUND ENGINEERING PRINCIPLES. | | | SPECIFIC AUTHORITY 471.008, 471.033(2), FS | | | LAW IMPLEMENTED 471.005(7), 471.033(2), FS | | | HISTORY?NEW 5-19-93, FORMERLY 21H-32.004, AMENDED | | | 4-2-2000, 6-26-01, 7-12-05 | | | | | | | | | PLEASE REVIEW AND PROVIDE THE REQUIRED DOCUMENTS WITH | | | THIS MASTER PERMIT. | | | | | | | | | | | | 5) SHEET E01 - THERE ARE NO INDICATIONS OF A MONITORED | | | FIRE SPRINKLER SYSTEM. THE CODE REQUIRES THAT THE FIRE | | | SPRINKLER SYSTEM BE MONITORED. | | | | | | PER NFPA 101, CHAPTER 9, FIRE PROTECTION SYSTEMS | | | | | | | | | 9.6 FIRE DETECTION, ALARM, AND COMMUNICATIONS SYSTEMS. | | | 9.6.1* GENERAL. | | | 9.6.1.1 THE PROVISIONS OF SECTION 9.6 SHALL APPLY ONLY | | | WHERE | | | SPECIFICALLY REQUIRED BY ANOTHER SECTION OF THIS CODE | | | OR WHERE | | | SUPERVISION OF A NEW FIRE SPRINKLER SYSTEM OR NEW FIRE | | | ALARM | | | SYSTEM IS REQUIRED BY THE FLORIDA BUILDING CODE. | | | | | | 2017 FLORIDA BUILDING CODE: | | | | | | 901.6 SUPERVISORY SERVICE. | | | | | | WHERE REQUIRED, FIRE PROTECTION SYSTEMS SHALL BE | | | MONITORED BY AN APPROVED SUPERVISING STATION IN | | | ACCORDANCE WITH NFPA 72. | | | | | | 901.6.1 AUTOMATIC SPRINKLER SYSTEMS. | | | | | | AUTOMATIC SPRINKLER SYSTEMS SHALL BE MONITORED BY AN | | | APPROVED SUPERVISING STATION. | | | | | | PLEASE PROVIDE AN APPLICABLE NOTE OF ACKNOWLEDGEMENT | | | AND COMPLIANCE | | | | | | | | | | | | 6) SHEET MO 1 - THERE ARE NO INDICATIONS OF CODE | | | REFERENCE TO NFPA 88A, PARKING STRUCTURES REGARDING | | | REQUIRED VENTILATION | | | | | | CHAPTER 6 BUILDING SERVICE AND FIRE PROTECTION | | | | | | 6.3 VENTILATION. | | | 6.3.1* ALL ENCLOSED PARKING STRUCTURES SHALL BE | | | VENTILATED BY | | | A MECHANICAL SYSTEM CAPABLE OF PROVIDING A MINIMUM OF | | | 300 L/MIN PER M2 OF FLOOR AREA (1 FT3/MIN PER FT2 OF | | | FLOOR | | | AREA) DURING HOURS OF NORMAL OPERATION. | | | | | | 6.3.3 MECHANICAL VENTILATING SYSTEMS SHALL BE INSTALLED | | | IN ACCORDANCE | | | WITH NFPA 90A. DUCTWORK SHALL BE CONSTRUCTED OF | | | NONCOMBUSTIBLE MATERIAL. | | | | | | PLEASE REVIEW, CORRECT AND PROVIDE SPECIFIC DETAIL OR | | | JUSTIFY. | | | | | | | | | | | | 7) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 8) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-10-29 |
|
|
Cont ID |
|
| Sent By |
rgathrig |
Date |
2018-10-29 |
Time |
12:28 |
Rev Time |
0.00 |
| Received By |
rgathrig |
Date |
2018-10-29 |
Time |
12:28 |
Sent To |
|
|
| Notes |
| 2018-10-29 12:29:14 | REVIEW COMPLETE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-10-29 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2018-10-29 |
Time |
12:34 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-09-25 |
Time |
10:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-08-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-27 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-11 |
Time |
17:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
P |
Date |
2018-08-24 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2018-08-24 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-08-24 |
Time |
08:20 |
Sent To |
|
|
| Notes |
| 2018-10-29 13:08:13 | MU-18-029910 | | 2018-08-24 08:20:40 | IMPACT STAMP ON THE SURVEY |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-10-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-10-23 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-10-23 |
Time |
14:37 |
Sent To |
|
|
| Notes |
| 2018-10-23 16:49:37 | MECHANICAL PROVISO | | | | | | SUBMIT THE MANUFACTURER'S SPECIFICATIONS AND | | | INSTALLATION INSTRUCTIONS FOR THE HONEYWELL CO AND NO2 | | | SENSORS, AND THE NOA'S FOR THE LOUVERS AND THE | | | CONDENSER STAND PRIOR TO FIRST MECHANICAL INSPECTION. | | | | | | ALL SUBMITTALS SHALL BEAR THE SHOP DRAWING STAMP OF | | | APPROVAL BY THE ENGINEER OF RECORD. | | | | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-08-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-08-15 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-08-15 |
Time |
08:47 |
Sent To |
|
|
| Notes |
| 2018-08-15 09:16:31 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #18070442 | | | 8/15/18 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE COOLING AND HEATING CALCULATIONS FOR THE NEW | | | AC SYSTEM- SECTION C403.2.1 FBC-17 ENERGY CONSERVATION. | | | . | | | | | | 2) ENERGY EFFICIENCY COMPLIANCE IS REQUIRED FOR THE | | | CONDITIONED OFFICE PORTION OF THE NEW PARKING GARAGE | | | BUILDING. PLEASE SEE SECTIONS C101.5 & C401.1 FBC EC | | | AND SUBMIT A COMPLIANCE REPORT. | | | | | | 3) M6.1: PLEASE PROVIDE MINIMUM VENTILATION | | | CALCULATIONS FOR THE PARKING GARAGE IN COMPLIANCE WITH | | | SECTION 404.2 FBC M. | | | | | | 404.2 MINIMUM VENTILATION. AUTOMATIC OPERATION OF THE | | | SYSTEM SHALL NOT REDUCE THE VENTILATION AIRFLOW RATE | | | BELOW 0.05 CFM PER SQUARE FOOT (0.00025 M3/S ? M2) OF | | | THE FLOOR AREA AND THE SYSTEM SHALL BE CAPABLE OF | | | PRODUCING A VENTILATION AIRFLOW RATE OF 0.75 CFM PER | | | SQUARE FOOT (0.0038 M3/S ? M2) OF FLOOR AREA. | | | | | | 4) SITE SPECIFIC WIND LOAD ENGINEERING AND FL. PRODUCT | | | APPROVALS AND/OR MIAMI-DADE NOA'S ARE REQUIRED FOR | | | INSTALLATION OF THE ROOF TOP EXHAUST FANS, CONDENSER | | | UNIT, AND THE GARAGE AIR INTAKE LOUVERS - SECTION | | | 301.15 FBC M, AND RULE 9N-3 FAC. | | | | | | 5) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE CO AND | | | NO2 SENSORS- SECTION 304.1 FBC M. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
2 |
Status |
P |
Date |
2018-10-29 |
|
|
Cont ID |
|
| Sent By |
rgathrig |
Date |
2018-10-29 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
rgathrig |
Date |
2018-10-29 |
Time |
10:12 |
Sent To |
|
|
| Notes |
| 2018-10-29 10:15:12 | (AN EC WAS PROVIDED WITH SURVEY PROVIDE IN SUBMITTAL | | | 18100459 THAT DEPICTS LOCATION OF BUILDING IN BOTH THE | | | 6?AND 7? NAVD88 FLOOD ZONES. EC SUBMITTED WAS NOT | | | CORRECT, EC WAS UNDER CONSTRUCTION AND ONLY LOCATED TOP | | | OF FOOTERS IT DID NOT KNOWLEDGE PROPOSED FLOOR | | | ELEVATION.EC ALSO HAD NOTATION OF FLOOD VENTS. RICHARD | | | DEAN OF DEAN SURVEYING WAS CONTACTED CONCERNING THE | | | FLOOD VENTS AND NOT HAVING A PROPOSED EC. HE STATED HE | | | USED THE GARAGE DOOR OPENINGS AS FLOOD OPENINGS. MR. | | | DEAN SAID HE WOULD PROVIDE A PROPER PROPOSED EC AND | | | PROVIDE AN UNDER CONSTRUCTION EC SHOWING FLOOR | | | ELEVATION. THE EC DATED 10/01/18 HE SAID IS NOT CORRECT | | | AND HE WILL VOID THAT DOCUMENT. R DEAN SAID HE WOULD | | | HAVE THE CORRECTED EC BY 11/02/18 COMMENT NOT CLOSED. | | | HOWEVER IT WILL BE A PROVISO REG) |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
F |
Date |
2018-08-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-27 |
Time |
12:05 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-27 |
Time |
12:05 |
Sent To |
|
|
| Notes |
| 2018-08-27 12:05:35 | SEE BUILDING REVIEW | | | THIS APPEARS TO BE LOCATED IN A SPECIAL FLOOD HAZARD | | | AREA | | | PROPOSED ELEVATION APPEARS TO COMPLY WITH 7'BFE + 2' | | | FREEBOARD | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-10-24 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-10-24 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-10-24 |
Time |
11:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-07-31 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-07-31 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-07-31 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2018-07-31 12:38:34 | 1) SUBMIT DOCUMENTATION AS TO HOW THE STORM DRAINAGE | | | WAS SIZED. THE SYSTEM SHALL BE SIZED IN ACCORDANCE WITH | | | THE 2017 FBC-PLUMBING SECS.1105.2, 1106.1, 1106.2, | | | 1106.3. | | | 2) SHT. A8.0.1 - DETAIL #1 - THE WATER CLOSET SHALL BE | | | LOCATED IN ACCORDANCE WITH THE 2017 FBC- ACCESSIBILITY | | | SEC.604.2. | | | 3) THE REAR GRAB BAR SHALL BE LOCATED IN ACCORDANCE | | | WITH 2017 FBC- ACCESS. SEC.604.5.2. | | | 4) SHOW THE CLEAR INSIDE LENGTH AND WIDTH DIMENSIONS OF | | | THE TOILET ROOM ON SHT. A8.0.1. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | 5) SHOW THE REQUIRED CLEAR FLOOR SPACE FOR THE WATER | | | CLOSET AND THE LAVATORY. COMPLY WITH 2017 FBC-ACCESS. | | | SECS. 604.3, 606.2. | | | 6) SHOW THE REQUIRED KNEE AND TOE CLEARANCES FFOR THE | | | LAVATORY PER THE 2017 FBC-ACCESS. SEC. 306. | | | 7) SHT. A8.0.1 - THE LOCATION OF THE MIRROR SHALL | | | COMPLY WITH 2017 FBC-SEC.603.3. | | | 8) SHOW THE LOCATION OF THE BABAY CHANGING STATION ON | | | THE FLOOR PLAN. | | | 9) THE DOOR FOR THE TOILET ROOM APPEARS TO SWING INTO | | | THE CLEAR FLOOR SPACE FOR THE LAVATORY. COMPLY WITH | | | 2017 FBC-ACCESS. SEC.603.2.3. | | | 10) SHT. P0.1 - THE ISOMETRIC OF THE ROOF DRAINAGE | | | SYSTEM DOES NOT CORRELATE WITH THE PLAN VIEW ON SHT. | | | P2.2. CLARIFY. | | | 11) A BACKFLOW PREVENTION DEVICE IS REQUIRED ON THE | | | DOMESTIC WATER AND THE IRRIGATION SYSTEM FOR THIS | | | STRUCTURE PER THE CITY OF WPB UTILITIES DEPT. CROSS | | | CONNECTION CONTROL MANUAL. | | | 12) A SEPARATE PLUMBING PERMIT WILL BE REQUIRED FOR THE | | | BACKFLOW DEVICES. | | | 13) SUBMIT A DETAIL FOR THE TERMINATION OF THE | | | CONDENSATE DRAIN. THE PLAN STATES THEY DISCHARGE TO A | | | GREEN AREA.WPB AMEND. TO FBC SEC. 107.2.1. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2018-10-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-10-29 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-10-29 |
Time |
13:02 |
Sent To |
|
|
| Notes |
| 2018-10-24 12:02:06 | SIGNATURE ON PLUMBING SHEETS OK. T.LARGE |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2018-08-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-25 |
Time |
19:33 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-25 |
Time |
19:33 |
Sent To |
|
|
| Notes |
| 2018-08-25 19:33:28 | ALL DIGITAL SIGNATURES (PLANS) | | | | | | 9/14/18 - PAPER ORIGINAL SOILS REPORT SUBMITTED UNDER | | | 18081379 FOUNDATION PERMIT (ISSUED) | | | | | | NEW SHEETS SUBMITTED NEXT REVIEW CYCLE REQUIRE REVIEW | | | | | 2018-08-15 09:17:01 | 1ST REVIEW MECH SHEETS OK- CCOLE |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
2 |
Status |
P |
Date |
2018-09-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-22 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-22 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2018-09-22 11:44:24 | AGREEMENT SUBMITTED UNDER SUBMITTAL #18090636 | | | THRESHOLD INSPECTION CONSULTING ENGINEERS, LLC (TICE) | | | J.F. DESNOYERS, PE | | | JENNINGS L. HILL, BN 3142 | | | DAVID ANTOINE, BN 7367 | | | BURTON SILVER, BN 2171 | | | AUTOBUILDERS, INC. | | | |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
1 |
Status |
F |
Date |
2018-08-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-27 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-27 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2018-08-27 09:23:44 | **RESIDENT INSPECTOR REQUIRED** | | | TILT WALL, WELDS & BOLTS | | | | | | RESIDENT INSPECTOR PACKAGE REQUIRED | | | 1. RESIDENT INSPECTOR AGREEMENT SIGNED BY ALL PARTIES | | | (SENT VIA EMAIL TO JASON KRAUS) | | | 2. COPIES OF LICENSES FOR ENGINEER, INSPECTORS | | | 3. RESUMES FOR ENGINEER, INSPECTORS | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-10-11 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2018-10-11 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2018-10-11 |
Time |
16:37 |
Sent To |
|
|
| Notes |
| 2018-10-11 16:37:48 | REVIEW STATUS: PASSED WITH PROVISOS | | | ___________________________________________ | | | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | | PROVISOS: | | | | | | 1. LANDSCAPING SHALL BE SUBMITTED AND REVIEWED AS A | | | SEPARATE PERMIT APPLICATION. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-08-20 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2018-08-20 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2018-08-20 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2018-08-20 14:15:31 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 08.20.2018 | | | PERMIT NO.: 18070442 | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. A SITE PLAN SHALL BE PROVIDED WHICH INCLUDES THE | | | FOLLOWING: | | | | | | ? DATE, NORTH ARROW, AND A GRAPHIC SCALE. | | | | | | ? VICINITY MAP SHOWING THE PROPERTY IN RELATION TO THE | | | SURROUNDING AREA. | | | | | | ? LOCATION OF THE PROPERTY LINE, RIGHT-OF-WAY, | | | PROPOSED/EXISTING EASEMENTS, WATER COURSES AND OTHER | | | ESSENTIAL FEATURES. | | | | | | ? STREETS, DRIVEWAYS, INTERSECTIONS, CURBS CUTS AND | | | TURNING LANES ADJACENT TO OR ACROSS FROM THE SUBJECT | | | PROPERTY. | | | | | | ? THE OUTLINES OF ALL BUILDINGS SHOWING THEIR PROPOSED | | | USES, SETBACKS, DIMENSIONS, FLOOR AREA, NUMBER OF | | | STORIES, HEIGHT AND POINTS OF ACCESS. | | | | | | ? LOCATION AND DIMENSIONS OF ALL PERIMETER TREATMENT | | | (SIDEWALKS, FENCES, WALLS, OR BERMS). | | | | | | ? LOCATION, HEIGHT AND SIZE OF ALL FREESTANDING SIGNS | | | AND OTHER ACCESSORY STRUCTURES. | | | | | | ? MEANS OF VEHICULAR AND PEDESTRIAN ACCESS TO AND FROM | | | THE SITE. | | | | | | ? LAYOUT AND LOCATION OF ALL OFF-STREET PARKING, | | | LOADING AND OTHER VEHICULAR USE AREAS, INCLUDING WHERE | | | APPLICABLE, THE DISTANCE FROM THE PRINCIPLE USES. | | | | | | ? LOCATION OF ALL DISABLED SPACES, RAMPS AND SIGNS. | | | | | | ? LOCATION AND SCREENING OF ALL GARBAGE RECEPTACLES. | | | | | | ? STANDARD CITY DETAILS OF PARKING (SMALL CAR, | | | HANDICAP SPACE, STANDARD SPACE), HANDICAP RAMPS, | | | DRIVEWAYS, DUMPSTERS AND SIGNS. | | | | | | ? SUPPLY A DATA TABLE IN THE FOLLOWING FORMAT: | | | | | | O EXISTING/PROPOSED LAND USE AND ZONING. | | | O TOTAL ACRES OF THE PROJECT. | | | O TOTAL GROSS BUILDING SQUARE FOOTAGE. | | | O PERCENT OF OPEN SPACE, LANDSCAPING, BUILDING | | | COVERAGE & IMPERMEABLE SURFACE. | | | O ACRES AND PERCENT OF WATER BODIES. | | | O DENSITY AND NUMBER OF DWELLING UNITS (RESIDENTIAL). | | | O PARKING COMPUTATIONS (PARKING REQUIRED, PROVIDED, | | | ETC.) | | | O FLOOR AREA RATIO (FAR). | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy