| Plan Review Stops For Permit 18070421 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2018-11-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-11-02 |
Time |
12:08 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-11-02 |
Time |
12:08 |
Sent To |
|
|
| Notes |
| 2018-11-02 12:09:12 | DIGITALLY SIGNED PAGES RECEIVED VIA EMAIL | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2018-11-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-11-01 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-11-01 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2018-11-01 16:49:01 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. TWO PAGES (A2.1, A3.1) ARE NOT SEALED AND DATED IN | | | ACCORDANCE WITH FLORIDA STATUTE 481. IT APPEARS THAT | | | SOMEONE SIGNED THE PAGE. BUT NEGLECTED TO SEAL AND DATE | | | IT. | | | | | | DOES THE ARCHITECT HAVE A DIGITAL SIGNATURE? IF YES, | | | PLEASE SEND THESE TWO SHEETS TO ME VIA EMAIL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-10-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-10-15 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-10-15 |
Time |
12:39 |
Sent To |
|
|
| Notes |
| 2018-10-15 12:55:13 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FROM PREVIOUS LIST: | | | | | | SHEET CS, FBC B 1004, CLARIFY OCCUPANT LOAD OF 6 | | | EMPLOYEES, USE GROUP "KITCHEN". | | | | | | FBC B 302.1, DECLARE AN OCCUPANCY CLASSIFICATION. FBC B | | | TABLE 1004.1.2, DECLARE AN OCCUPANT LOAD. | | | | | | 2ND REVIEW - 17 SEATS AND 12 EMPLOYEES ARE NOTED. SEE | | | FBC B 1004.1.2, ARE THE SEATS FIXED? IF THEY ARE, | | | REVISE PLAN TO NOTE FIXED SEATING, PROVIDE DETAILS, AND | | | SHOW COMPLIANCE WITH FBC A 902. IF THEY ARE NOT FIXED, | | | REVISE IN ACCORDANCE WITH FBC B TABLE 1004.1.2. | | | | | | IT APPEARS THAT ARCHITECT IS CALCULATING OCCUPANTS AT | | | 60SF PER PERSON PLUS SEATS. IT APPEARS THAT 15SF PER | | | PERSON SHOULD BE UTILIZED, SEE TABLE B 1004.1.2, | | | ASSEMBLY WITHOUT FIXED SEATS. IF ARCHITECT DISAGREES, | | | PLEASE CONTACT ME PRIOR TO RESUBMITTING. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-08-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-14 |
Time |
06:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-14 |
Time |
06:41 |
Sent To |
|
|
| Notes |
| 2018-08-14 06:45:11 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. SHEET CS, FBC B 1004, CLARIFY OCCUPANT LOAD OF 6 | | | EMPLOYEES, USE GROUP "KITCHEN". | | | | | | FBC B 302.1, DECLARE AN OCCUPANCY CLASSIFICATION. FBC B | | | TABLE 1004.1.2, DECLARE AN OCCUPANT LOAD. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-10-29 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-10-29 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-10-29 |
Time |
08:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-09-28 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-09-28 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-09-28 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2018-09-28 14:34:16 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PER THE WPB AMENDMENTS TO THE FBC, PLAN (EACH SHEET | | | OF ALL COPIES) IS REQUIRED TO BEAR THE NAME AND BE | | | SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE | | | DESIGN. PROVIDE CORRECTION. WPB FBC 107.1, 107.2; FS | | | 471, 481 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-07-30 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-07-30 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-07-30 |
Time |
10:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
| Rev No |
1 |
Status |
P |
Date |
2018-10-29 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-10-29 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-10-29 |
Time |
08:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2018-10-30 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-10-30 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-10-30 |
Time |
11:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-09-26 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-09-26 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-09-26 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2018-09-26 10:04:27 | PERMIT #18070421 | | | FIRE PLAN REVIEW COMMENTS: | | | | | | APPROVED PROVISO: | | | | | | 1) SHEET CS: OCCUPANT LOAD CONTINUES TO BE INCORRECT. | | | PROPOSED NUMBER OF SEATS IS 17, HOWEVER IT STATES THAT | | | THE OCCUPANT LOAD IS 12. THE OCCUPANT LOAD SHOULD NOT | | | BE LESS THAN THE NUMBER OF SEATS. | | | THIS NEEDS TO BE REVIEWED AND CORRECTED. PLEASE PROVIDE | | | THE TOTAL OCCUPANT LOAD (EMPLOYEES, SEATED GUESTS, | | | WAITING AREA GUESTS, ETC.). | | | THIS WILL BE VERIFED IN THE FIELD AND AN OCCUPANT LOAD | | | SIGN ISSUED PRIOR TO FINAL INSPECTION. | | | | | | SUE ELLEN CALDERON | | | ASST. FIRE MARSHAL | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2018-07-25 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-07-25 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-07-25 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2018-07-25 11:27:32 | PERMIT # 18070421 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | 1) SHEET CS: UPDATE THE CODE LIST TO REFERENCE THE 6TH | | | EDITION OF THE FLORIDA FIRE PREVENTION CODE WHICH | | | CONTAINS THE 2015 EDITION OF BOTH NFPA 1 AND NFPA 101 | | | WITH FLORIDA AMENDMENTS. (2017 LISTED ON SHEET CS) | | | | | | 2) FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING | | | DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A | | | FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN | | | 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE | | | PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST | | | BE SUBMITTED BY EMAIL ([email protected]) OR IN WRITING | | | (FAX: 561-804-4774) AND APPROVED BY THE OFFICE OF THE | | | FIRE MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY. | | | | | | 3) ENTRY DOORS: THUMB-TURN LOCK TO BE EQUIPPED WITH A | | | LOCK/UNLOCK INDICATOR. | | | | | | 4) EACH FIRE BARRIER SHALL BE PERMANENTLY IDENTIFIED | | | WITH SIGNS OR STENCILING READING FIRE BARRIER-PROTECT | | | ALL OPENINGS. CHARACTERS SHALL BE AT LEAST 4-INCHES IN | | | HEIGHT AND HALF-INCH IN WIDTH. IDENTIFICATION SHALL BE | | | SPACED NOT MORE THAN 15 FEET ON CENTER. | | | | | | 5) PROVIDE 44 INCH WIDE STRIPING (DEMARCATION) IN | | | STOREROOM TO ENSURE EGRESS PATH REQUIREMENTS ARE | | | MAINTAINED AT ALL TIMES. | | | | | | 6) SUB-PERMITS REQUIRED FOR ALL WORK DONE RELATED TO | | | THE FIRE ALARM AND SPRINKLER SYSTEM. | | | | | | 7) WHERE MUSIC SYSTEMS ARE BEING INSTALLED IN TENANT | | | SPACES: THE SPEAKER SYSTEM WILL NEED TO BE TESTED | | | AGAINST THE FIRE ALARM SYSTEM TO ENSURE THAT THE | | | MINIMUM REQUIRED DECIBEL LEVELS OF THE FIRE ALARM | | | SYSTEM ARE BEING MET. PENDING RESULTS OF FIELD | | | INSPECTION/FIRE ALARM TEST, ADDITIONAL REQUIREMENTS MAY | | | BE NEEDED. | | | | | | 8) SHEET CS: OCCUPANT LOAD IS INCORRECT. ONLY ACCOUNTS | | | FOR EMPLOYEES (6). THE NUMBER OF SEATS PROVIDED, ALONE, | | | IS 17. PLEASE REVIEW AND PROVIDE ACCURATE OCCUPANT | | | LOAD, ACCOUNTING FOR SEATS, STAFF, AND QUEING AREA. | | | | | | SUE ELLEN CALDERON | | | ASSISTANT FIRE MARSHAL | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-11-09 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-11-09 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-10-17 |
Time |
13:58 |
Sent To |
|
|
| Notes |
| 2018-11-08 12:27:13 | TO ES | | 2018-10-19 13:58:46 | B25 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-10-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-10-15 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-18 |
Time |
15:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-08-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-14 |
Time |
06:45 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-10 |
Time |
10:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2018-11-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-11-07 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-11-07 |
Time |
15:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2018-09-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-09-28 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-09-28 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2018-09-28 16:49:02 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #18070421 | | | 9/28/18 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M2 WAS SIGNED, BUT NOT SEALED BY THE ENGINEER | | | OF RECORD- SECTION 61G15-23.002 FAC. | | | | | | 2) M1.0, NEW COMMENT: MINIMUM HEAT AND VENTILATION IS | | | REQUIRED FOR THE MANAGER'S OFFICE IN COMPLIANCE WITH | | | SECTION 309.1 AND TABLE 403.3.1.1 FBC M. PLEASE REVISE | | | THE PLAN TO SHOW COMPLAINCE. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-07-17 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-07-17 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-07-16 |
Time |
17:46 |
Sent To |
|
|
| Notes |
| 2018-07-17 11:37:49 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #18070421 | | | 7/17/18 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET A3.0: PLEASE SHOW THE LOCATION OF THE TURBO | | | CHEF OVEN ON THE EQUIPMENT FLOOR PLAN. IT IS #384 IN | | | THE SCHEDULE. | | | | | | 2) M1.0: A TYOE II HOOD IS REQUIRED FOR THE NEW TURBO | | | CHEF OVEN- SEE SECTION 507.3 FBC M BELOW: | | | | | | 507.3 TYPE II HOODS. | | | TYPE II HOODS SHALL BE INSTALLED ABOVE DISHWASHERS AND | | | APPLIANCES THAT PRODUCE HEAT OR MOISTURE AND DO NOT | | | PRODUCE GREASE OR SMOKE AS A RESULT OF THE COOKING | | | PROCESS, EXCEPT WHERE THE HEAT AND MOISTURE LOADS FROM | | | SUCH APPLIANCES ARE INCORPORATED INTO THE HVAC SYSTEM | | | DESIGN OR INTO THE DESIGN OF A SEPARATE REMOVAL SYSTEM. | | | TYPE II HOODS SHALL BE INSTALLED ABOVE ALL APPLIANCES | | | THAT PRODUCE PRODUCTS OF COMBUSTION AND DO NOT PRODUCE | | | GREASE OR SMOKE AS A RESULT OF THE COOKING PROCESS. | | | SPACES CONTAINING COOKING APPLIANCES THAT DO NOT | | | REQUIRE TYPE II HOODS SHALL BE PROVIDED WITH EXHAUST AT | | | A RATE OF 0.70 CFM PER SQUARE FOOT (0.00033 M3/S). FOR | | | THE PURPOSE OF DETERMINING THE FLOOR AREA REQUIRED TO | | | BE EXHAUSTED, EACH INDIVIDUAL APPLIANCE THAT IS NOT | | | REQUIRED TO BE INSTALLED UNDER A TYPE II HOOD SHALL BE | | | CONSIDERED AS OCCUPYING NOT LESS THAN 100 SQUARE FEET | | | (9.3 M2). SUCH ADDITIONAL SQUARE FOOTAGE SHALL BE | | | PROVIDED WITH EXHAUST AT A RATE OF 0.70 CFM PER SQUARE | | | FOOT [.00356 M3/(S ? M2)]. | | | | | | 3) M1.0: PROVIDE A DUCT SMOKE DETECTOR IN THE SUPPLY | | | SIDE OF THE RTU IN ACCORDANCE WITH SECTION 606.2.1 FBC | | | M. PLACE A SYMBOL AT THE REQUIRED LOCATION. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-11-06 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2018-11-06 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-11-06 |
Time |
07:42 |
Sent To |
|
|
| Notes |
| 2018-11-06 15:21:47 | PLUMBING COMMENTS: APPROVED | | | PROVISO | | | REGARDING THE WATER TREATMENT SYSTEM, ITEM #8 ON THE | | | EQUIPMENT/FIXTURE SCHEDULE, DEFERRED SUBMITTALS SHALL | | | BE PROVIDED TO THE BUILDING TO THE BUILDING OFFICIAL | | | AND APPROVED PRIOR TO FIRST PLUMBING INSPECTION IN | | | ACCORDANCE WITH WPB FBC 107.3.4.1. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-10-04 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2018-10-04 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-10-04 |
Time |
13:49 |
Sent To |
|
|
| Notes |
| 2018-10-04 13:52:44 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 2ND REVIEW: | | | PLUMBING COMMENTS: DENIED | | | | | | 1. RE: PLAN SHEET P4; SHEET WAS SIGNED, BUT NOT SEALED | | | BY THE ENGINEER OF RECORD- SECTION 61G15-23.002 FAC. | | | 2. RE: PLAN SHEET P2.1; PLEASE PROVIDE MANUFACTURE | | | SPECIFICATIONS FOR ITEM #8,THE WATER TREATMENT (RO) | | | SYSTEM (SECOND REQUEST). WPB FBC 107.2.1 | | | 3. RE: PLAN SHEET P2.1; PROVIDE NOTE AT RPZ INDICATING | | | THE RELIEF OUTLET SHALL DISCHARGE THROUGH AN AIR GAP TO | | | THE FLOOR SINK IN ACCORDANCE WITH FBC PL 608.13.2. WPB | | | FBC 107.2.1 | | | 4. RE: PLAN SHEET P2.1; SCHEMATIC AND FLOOR PLAN SHOWS | | | WHAT APPEAR SYMBOLS FOR A CHECK VALVE. ARE THESE CHECK | | | VALVES OR BACKFLOW PREVENTORS? IF BACKFLOW PREVENTORS | | | PLEASE INDICATE TYPE AND STANDARD SUCH AS ASSE 1022. IF | | | IT IS THE INTENT TO PROTECT THE WATER SUPPLY TO ITEMS | | | INCLUDING BUT NOT LIMITED TO THE CARBONATED BEVERAGE | | | DISPENSERS AND COFFEE MAKERS WITH AN AIR GAP, THEN | | | PROVIDE SPECS FOR THE UNIT THAT SHOW IT CAN BE DONE. | | | NOTES REQUIRING AN INDIRECT WASTE BE RUN TO A FLOOR | | | SINK THROUGH AN AIR GAP DOES NOT ADDRESS BACKFLOW | | | CONNECTIONS IN THE WATER SUPPLY. AIR GAPS THAT ADDRESS | | | SUCH CONNECTIONS ARE AS NOTED IN FPC PL 608.15.1. | | | PLEASE CLARIFY. WPB FBC 107.2.1 | | | 5. RE: PLAN SHEET P2.1; EQUIPMENT SCHEDULE, ITEM #204. | | | THE ENGINEER IS TO PROVIDE DETAILS AND SPECS FOR MIXING | | | VALVE AND BACKFLOW PREVENTOR INCLUDING PIPING | | | ARRANGEMENT AND VALVING IN ACCORDANCE WITH THE | | | REQUIREMENTS OF FBC PL AND WPB FBC. WPB FBC 107.2.1 | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED "VOID". | | | THE COMMENT RESPONSE LETTER NOTED ON THE TRANSMITTAL | | | DID NOT APPEAR WHEN THIS REVIEW TOOK PLACE. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-08-10 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-08-10 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-08-10 |
Time |
08:20 |
Sent To |
|
|
| Notes |
| 2018-08-10 13:04:07 | 1ST REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PROVIDE GREASEE TRAP SIZING CALCULATION INCLUDING | | | EXISTING GREAS LOAD AND NEW LOAD TO DETERMINE THAT THE | | | EXISTING GREASE INTERCEPTOR'S ARE LARGE ENOUGH. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | 2. SHT. P2.1 UNDER FIXTURE/EQUIPMENT SCHEDULE #10 IN | | | REMARKS IT IS REFERENCING A GAS GRIDDLE AND CLAMSHELL | | | PLEASE CLARIFY. PER WPB AMED TO FBC 107.2.1 | | | | | | 3.PLEASE PROVIDE MANUFACTURE SPECIFICATIONS FOR THE | | | WATERHEATER, WATER TREATMENT SYSTEM AND THE WATER | | | SOFTENER. . PER WPB AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2018-11-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-11-02 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-11-02 |
Time |
12:09 |
Sent To |
|
|
| Notes |
| 2018-11-02 12:09:55 | DIGITALLY SIGNED ARCHITECTURAL PAGES RECEIVED VIA | | | EMAIL, FORWARDED TO FILENET | | | (2 PAGES WERE NOT SEALED & DATED) | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2018-11-08 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2018-11-08 |
Time |
17:09 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2018-11-08 |
Time |
17:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-10-12 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2018-10-12 |
Time |
13:44 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2018-10-12 |
Time |
12:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-07-30 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2018-07-30 |
Time |
16:44 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2018-07-30 |
Time |
16:44 |
Sent To |
|
|
| Notes |
|
|