| Plan Review Stops For Permit 18070409 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2018-07-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-07-18 |
Time |
19:07 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-07-18 |
Time |
18:51 |
Sent To |
|
|
| Notes |
| 2018-07-18 19:07:37 | FBC-R4501.19 FINAL INSPECTION. FINAL ELECTRICAL AND | | | BARRIER CODE INSPECTION SHALL BE COMPLETED PRIOR TO | | | FILLING THE POOL WITH WATER. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-07-19 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-07-19 |
Time |
17:33 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-07-19 |
Time |
17:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2018-07-23 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-07-23 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-07-23 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2018-07-23 08:51:35 | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | | THIS TIME. A SEPARATE GAS PERMIT IS REQUIRED FOR A | | | CONTRACTOR TO PERFORM THE RELATED WORK. PROVIDE | | | COMPLETE PLANS THAT REFLECT THE ENTIRE SCOPE OF GAS | | | WORK TO BE DONE. WPB AMEND. TO FBC SEC.107.2.1. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-08-06 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-08-06 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-08-06 |
Time |
11:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-08-01 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-08-01 |
Time |
06:07 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-07-30 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2018-07-31 14:03:05 | RESUB ROUTED TO TKLARGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-07-23 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-07-23 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-07-10 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2018-07-12 10:43:10 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-08-06 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-08-06 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-08-06 |
Time |
11:09 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-08-01 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-08-01 |
Time |
06:06 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-08-01 |
Time |
05:22 |
Sent To |
I |
|
| Notes |
| 2018-08-01 06:06:43 | 1) THE POOL PLANS SHOW TDH CALCULATIONS BASED ON THE | | | SIMPLIFIED TDH CALCULATION METHOD. THIS METHOD IS | | | ALLOWED IN THE 2006 VERSION OF APSP 7 BUT IS NO LONGER | | | ALLOWED IN THE 2013 EDITION OF APSP 7 WHICH HAS BEEN | | | ADOPTED BY THE 2017. | | | FBC. TOTAL DYNAMIC HEAD CALCULATIONS SHALL BE DONE IN | | | ACCORDANCE WITH 2013 APSP 7 SEC.4.4.9.1. | | | 2) THE GAS POOL HEATER SHALL HAVE A MINIMUM THERMAL | | | EFFICIENCY OF 82% PER THE 2017 FBC-ENERGY | | | SEC.R403.10.4. | | | 3) TWO PUMP CURVES HAVE BEEN PROVIDED BUT THERE IS NO | | | INDICATION ON EITHER CURVE WHICH CURVE KEY IS SPECIFIC | | | TO THE TDH CALCULATIONS. THERE ARE DIFFERENT RPM'S ON | | | THE CURVES. CLARRIFY WHICH ONE. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-07-23 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-07-23 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-07-23 |
Time |
08:15 |
Sent To |
I |
|
| Notes |
| 2018-07-23 08:50:20 | 1) SUBMIT TOTAL DYNAMIC HEAD CALCULATIONS FOR THE | | | MAXIMUM SYSTEM FLOW FOR THE POOL, THE SPA AND THE POOL | | | FEATURE. THE MAXIMUM FLOW OF THE PUMP FROM ITS PUMP | | | CURVE IS NO LONGER ALLOWED TO BE USED IN DETERMINING | | | MAXIMUM SYSTEM FLOW RATE PER ANSI/APSP/ICC 7 - 2013 | | | SECS. 4.4.9, 4.4.9.1. THE 2013 EDITION ADDRESSES FLOW | | | RATE IN GALLONS PER MINUTE (GPM). IT REQUIRES THAT | | | MAXIMUM SYSTEM FLOW RATE DOES NOT EXCEED THE LISTED | | | MAXIMUM FLOW RATE OF THE SUCTION OUTLET FITTING | | | ASSEMBLY (DRAIN COVER).THE TDH CALCULATIONS MUST | | | INCLUDE ALL OF THE SYSTEM COMPONENTS IN THE PIPING | | | SYSTEM INCLUDING THE FILTER. | | | 2) SUBMIT TWO COPIES OF THE POOL PUMP CURVE FOR THE | | | POOL, THE SPA AND POOL FEATURE. IDENTIFY ON THE PUMP | | | CURVE WHICH CURVE KEY IS SPECIFIC TO THE PUMP BEING | | | INSTALLED ON THESE ITEMS. THIS IS NEEDED TO CONFIRM THE | | | MAXIMUM SYSTEM FLOW FROM THE TDH CALCULATIONS. | | | 3) INDICATE ON THE POOL PUMP SPECS WHICH PUMP IS BEING | | | INSTALLED. WPB AMEND. TO FBC SEC. 107.2.1. | | | 4) BACKFLOW PREVENTERS MAY BE REQUIRED ON THE | | | WATER/FIRE BOWL UNITS. | | | 5) THE GAS HEATER SHALL HAVE A MINIMUM OF 82% | | | EFFICIENCY PER THE 2017 FBC-ENERGY TABLE C404.2. SUBMIT | | | VERIFICATION. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-07-17 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-07-17 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-07-17 |
Time |
15:20 |
Sent To |
|
|
| Notes |
|
|