| Plan Review Stops For Permit 18070248 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-10-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-10-01 |
Time |
07:40 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-10-01 |
Time |
07:40 |
Sent To |
P |
|
| Notes |
| 2018-10-01 07:42:02 | AE FLOOD ZONE, THE GENERATOR IS TO BE AT OR ABOVE THE | | | FLOOR ELEVATION OF THE DWELLING. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2018-07-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-07-16 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-07-16 |
Time |
13:27 |
Sent To |
P |
|
| Notes |
| 2018-07-16 13:33:57 | AE FLOOD ZONE, THE GENERATOR IS TO BE AT OR ABOVE THE | | | FLOOR ELEVATION OF THE DWELLING. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-09-28 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-09-28 |
Time |
17:17 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-09-28 |
Time |
17:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-07-19 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-07-19 |
Time |
17:49 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-07-19 |
Time |
17:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2018-11-01 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-11-01 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-11-01 |
Time |
11:56 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2018-10-03 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-10-03 |
Time |
06:18 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-10-03 |
Time |
05:12 |
Sent To |
I |
|
| Notes |
| 2018-10-03 05:54:52 | 1) SUBMIT TWO COPIES OF A SURVEY SHOWING THE LOCATION | | | OF THE GENERATOR IN RELATION TO BUILDING OPENINGS, | | | DISTANCE FROM THE STRUCTURE, ETC. 2017 FBC 107.2.1. | | | 2) THE 3/4 INCH PE TO THE EXISTING GAS LOADS IS | | | UNDERSIZED.THE ORIGINAL PLAN ON FILE WITH THE CITY | | | SHOWS THE LINE FROM THE OUTLET OF THE GAS METER GOING | | | INTO A TEE AND THE TOTAL LOAD BEING DISTRIBUTED BETWEEN | | | 2 - 3/4 INCH PE LINES WHICH MEETS CODE. ONE 3/4 INCH PE | | | LINE SERVING THE EXISTING BTU LOAD OF 1,697,000 WILL | | | NOT WORK PER TABLE 402..2 (22) OF THE FUEL GAS CODE.IF | | | ONE LINE IS TO SUPPLY THE EXISTING BTU LOAD, IT SHALL | | | BE 1 1/4 INCH PE. | | | 3) YOU HAVE SUBMITTED COPIESS OF AN EXISTING CITY | | | DRAWING TO WHICH YOU HAVE ADDED THE GENERATOR ONTO THE | | | DRWAING. THESE DOCUMENTS ARE FOR REFERENCE ONLY AND | | | CANNOT BE USED TO ADD APPLIANCES/ EQUIPMENT AND BE | | | SUBMITTED FOR PERMIT. REMOVE THESE DRAWINGS FROM THE | | | PERMIT PACKAGE. 2017 FBC SEC.107.2.1. | | | 4) THERE ARE COPIES OF 2 DIFFERENT GAS DRAWINGS IN THIS | | | SUBMITTAL. REMOVE ALL OLD GAS DRAWINGS AND COMBINE THE | | | DOCUMENTS INTO TWO FULL, COMPLETE SETS OF PLANS FOR | | | REVIEW. 2017 FBC SEC. 107.2.1. | | | 5) THE GENERATOR SHALL BE A MINIMUM OF 10 FEET FROM ANY | | | BUILDING OPENING INCLUDING SOFFIT VENTS. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-07-24 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-07-24 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-07-24 |
Time |
09:24 |
Sent To |
I |
|
| Notes |
| 2018-07-24 09:44:46 | 1) THE EXISTING GAS DRAWING SHOWS A 1 INCH LINE FOR THE | | | FUTURE GENERATOR AND THE THE DRAWING SUBMITTED BY | | | STATIC ELECTRIC SHOWS A 3/4 INCH LINE. CLARIFY. | | | 2) THE GAS LINE AT THE OUTLET OF THE GAS METER SHALL BE | | | 1 1/4 INCH SCH. 40 PIPE BASED ON GAS SIZING TABLE 402.4 | | | (5) AT 2 PSI AND A TOTAL DEVELOPED LENGTH OF 175 FEET | | | TO THE FARTHEST REGULATOR. | | | 3) SUBMIT TWO COPIES OF THE INSTALLATION INSTRUCTIONS | | | FOR THE REGULATOR. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-11-01 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-11-01 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-10-16 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2018-10-17 13:53:09 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-10-03 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-10-03 |
Time |
06:18 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-09-21 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2018-09-24 16:04:23 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-07-24 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-07-24 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-07-06 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2018-07-09 13:06:34 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2018-10-26 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-10-26 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-10-26 |
Time |
11:57 |
Sent To |
G |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-09-28 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-09-28 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-09-28 |
Time |
11:29 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-07-12 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-07-12 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-07-12 |
Time |
15:41 |
Sent To |
|
|
| Notes |
| 2018-07-12 15:46:51 | ZONING REVIEW FAILED, DUE TO THE FOLLOWING: | | | | | | 1) THE LOCATION OF THE PROPOSED GENERATOR DOES NOT MEET | | | SETBACK REQUIREMENTS. THE GENERATOR SHOULD BE AT LEAST | | | 11' FROM THE WEST PROPERTY LINE. | | | | | | NOTE: PURSUANT TO 94-305(B)(4) - MECHANICAL EQUIPMENT | | | MAY NOT PROJECT MORE THAN 4 FEET INTO A SETBACK. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ | | | ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: 561-822-1442 | | | E-MAIL: [email protected] |
|
|