| Plan Review Stops For Permit 18070237 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2018-07-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-07-23 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-23 |
Time |
10:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-07-31 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-07-31 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-07-31 |
Time |
12:33 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-07-24 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-07-24 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-07-23 |
Time |
17:11 |
Sent To |
|
|
| Notes |
| 2018-07-24 09:26:55 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. THE NEC AND FBC SPECIFIED FOR DESIGN ON SHEET CS IS | | | NOT THE CURRENT CODE. PROVIDE CORRECTION. FBC PREFACE | | | (ALSO SEE CURRENT CODES ABOVE) | | | 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | | 408.4 | | | 3. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. SPECIFYING THAT THE CONTRACTOR IS REQUIRED | | | TO CONFIRM THE LOAD IS NOT SATISFACTORY. NEC 215.2, | | | 220, 408.30 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-07-31 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-07-31 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-07-31 |
Time |
14:27 |
Sent To |
I |
|
| Notes |
| 2018-07-31 14:32:57 | PERMIT # 18070237 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | APPROVED PROVISO, AS THE FOLLOWING COMMENTS WERE NOT | | | ADDRESSED IN THE RESUBMITTAL: | | | | | | 1) UPDATE THE CODE LIST TO REFERENCE THE 6TH EDITION OF | | | THE FLORIDA FIRE PREVENTION CODE WHICH CONTAINS THE | | | 2015 EDITION OF BOTH NFPA 1 AND NFPA 101 WITH FLORIDA | | | AMENDMENTS. | | | | | | 2) CS: OCCUPANT LOAD IS LISTED AS "EXISTING/UNCHANGED". | | | PLEASE PROVIDE THE OCCUPANT LOAD, AS THE EXISTING | | | OCCUPANT LOAD IS UNKNOWN. | | | | | | | | | SUE ELLEN CALDERON | | | ASSISTANT FIRE MARSHAL | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2018-07-12 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-07-12 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-07-12 |
Time |
11:13 |
Sent To |
|
|
| Notes |
| 2018-07-12 11:28:41 | PERMIT # 18070237 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | 1) UPDATE THE CODE LIST TO REFERENCE THE 6TH EDITION OF | | | THE FLORIDA FIRE PREVENTION CODE WHICH CONTAINS THE | | | 2015 EDITION OF BOTH NFPA 1 AND NFPA 101 WITH FLORIDA | | | AMENDMENTS. | | | | | | 2) SHEETS CS, A1.2, AND E2.0: SEATING LAYOUT CONFLICTS | | | ON THESE SHEETS. | | | SHEET CS: 2 ROWS OF 2-TOP TABLES/CHAIRS AND ACCESSIBLE | | | SEATING ON 1 END OF ROW OF BOOTHS. | | | SHEET A1.2: 1 ROW OF 2-TOP TABLES/CHAIRS AND ACCESSIBLE | | | SEATING ON 1 END OF ROW OF BOOTHS. | | | SHEET E2.0: 1 ROW OF T-TOP TABLES/CHAIRS AND ACCESSIBLE | | | SEATING ON BOTH ENDS OF ROW OF BOOTS. | | | PLEASE REVIEW AND PROVIDE ACCURATE SEATING ARRANGEMENT | | | ON ALL SHEETS. | | | | | | 3) CS: OCCUPANT LOAD IS LISTED AS "EXISTING/UNCHANGED". | | | PLEASE PROVIDE THE OCCUPANT LOAD, AS THE EXISTING | | | OCCUPANT LOAD IS UNKNOWN. | | | | | | | | | SUE ELLEN CALDERON | | | ASSISTANT FIRE MARSHAL | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-08-01 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-08-01 |
Time |
07:21 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-07-27 |
Time |
06:12 |
Sent To |
|
|
| Notes |
| 2018-07-31 14:18:02 | 7/30 TO FIRE BOX | | | | | | | | 2018-07-30 17:12:36 | 7/30 TO JP DESK | | | | | | | | 2018-07-30 06:12:33 | SENT EMAIL TO APPLICANT, DOES NOT APPEAR THAT FIRE | | | COMMENTS WERE ADDRESSED (ONLY ELECTRICAL); ELECTRICAL | | | SHEETS NOT SIGNED & SEALED | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-07-25 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-07-25 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-07-09 |
Time |
14:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2018-07-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-07-23 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-07-23 |
Time |
16:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2018-07-25 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-07-25 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-07-25 |
Time |
10:48 |
Sent To |
I |
|
| Notes |
| 2018-07-25 10:49:31 | EQUIPMENT SHOWN AS EXISTING TO REMAIN. PLUMBING PERMIT | | | NOT REQUIRED. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2018-08-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-01 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-01 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2018-08-01 14:26:43 | RECEIVED 1 SET S&S ELECTRICAL SHEETS | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2018-07-31 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-07-31 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-31 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2018-07-31 14:15:15 | NEED SIGNED AND SEALED ELECTRICAL SHEETS; APPLICANT TO | | | PROVIDE PRIOR TO ISSUANCE | | | |
|
|