| Plan Review Stops For Permit 18070228 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-10-25 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-10-25 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-10-25 |
Time |
16:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-10-04 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-10-04 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-10-04 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2018-10-04 09:12:17 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 18070228-2 | | | REVISION 2ND REVIEW: OCTOBER 4, 2018 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER I | | | [email protected] | | | 561-805-6718 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC AMENDED = FLORIDA BUILDING CODE,6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC ENERGY = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. [FBC 107.2.1.2]PROVIDE PRODUCT APPROVALS FOR THE | | | CHANGE OF ROOFING OFF MASTER SUITE. | | | 1-2. [RAS 117]PROVIDE ENGINEERING FOR ENHANCED NAILING | | | AS STATED IN PRODUCT APPROVAL UNDER GENERAL LIMITATIONS | | | #7. | | | PLEASE PROVIDE THE MAXIMUM DESIGN PRESSURE, CHOOSE THE | | | SYSTEM TO BE INSTALLED AND PROVIDE ENHANCED NAILING IF | | | APPLICABLE TO THE SYSTEM BEING INSTALLED. | | | | | | 2. OK | | | | | | 3. OK | | | | | | NOTE: | | | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | | OF MATERIALS REQUESTED. | | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-08-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-08-08 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-08-08 |
Time |
15:13 |
Sent To |
|
|
| Notes |
| 2018-08-08 16:21:34 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 18070228 | | | REVIEWED: AUGUST 8, 2018 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC EB = FBC EXISTING BUILDING | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. [FBC 107.2.1.2]PROVIDE PRODUCT APPROVALS FOR THE | | | CHANGE OF ROOFING OFF MASTER SUITE. | | | | | | 2. PROVIDE ROOF DRAINAGE CALCULATION AND SCUPPER DETAIL | | | TO MEET [FBC R903.4]ROOF DRAINAGE AND SCUPPERS. | | | | | | 3. PLEASE PROVIDE DESCRIPTION OF CHANGES IN THE | | | REVISION. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-10-25 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-10-25 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-10-25 |
Time |
11:27 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-09-22 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-09-22 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-09-22 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2018-09-22 15:33:10 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. FEEDER F1 TO FPL IS NOT RATED FOR 600 AMPS. PROVIDE | | | CORRECTION. NEC 310.15(B)(16) | | | 2. FEEDER F2A IS NOT RATED FOR 600 AMPS. PROVIDE | | | CORRECTION. NEC 310.15(B)(16) | | | 3. FEEDER F2B IS NOT RATED FOR 600 AMPS. PROVIDE | | | CORRECTION. NEC 310.15(B)(16) | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-07-30 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-07-30 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-07-30 |
Time |
06:50 |
Sent To |
|
|
| Notes |
| 2018-07-30 10:19:41 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. NO REVISIONS ARE INDICATED ON PLAN. PROVIDE | | | NARRATIVE OF REVISIONS AND CLOUD THESE CHANGES ON PLAN. | | | WPB FBC 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD | | | SHEETS?. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2018-08-22 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-08-22 |
Time |
18:11 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-08-22 |
Time |
18:11 |
Sent To |
|
|
| Notes |
| 2018-08-22 18:12:10 | GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN | | | THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN | | | PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS | | | WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE | | | RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT | | | REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE. AT | | | THIS TIME. WPB AMENDMENTS TO FBC SEC. 107.2.1. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-10-25 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-10-25 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-10-16 |
Time |
11:36 |
Sent To |
|
|
| Notes |
| 2018-10-18 11:36:56 | RESUB ROUTED TO JPEARSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-10-04 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-10-04 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-09-11 |
Time |
11:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-08-22 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-08-22 |
Time |
18:12 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-07-06 |
Time |
10:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-10-04 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-10-04 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-10-04 |
Time |
14:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2018-07-30 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-07-30 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-07-30 |
Time |
11:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-10-02 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-10-02 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-10-02 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2018-10-02 09:11:07 | 2ND REVIEW: | | | PLUMBING COMMENTS: APPROVED | | | | | | PROVISO | | | | | | 1. THE VALVES FOR THE STACKABLE WASHING MACHINE(S) | | | SHALL BE ACCESSIBLE. FBC RES P2903.9.3 | | | A. PLEASE REVIEW RED LINED NOTES MADE ON SHEET P-2 REV | | | 1 FOR CLARIFICATION. | | | 2. A WATER-HAMMER ARRESTOR SHALL BE INSTALLED WHERE | | | QUICK-CLOSING VALVES ARE UTILIZED. FBC RES P2903.5 | | | A. PLEASE REVIEW RED LINED NOTES MADE ON SHEET P-1 REV | | | 1 FOR CLARIFICATION. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2018-08-22 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-08-22 |
Time |
18:12 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-08-22 |
Time |
18:12 |
Sent To |
|
|
| Notes |
| 2018-08-22 18:13:06 | 08/22/18 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVE PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
pgreilic |
Date |
2018-09-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2018-09-18 |
Time |
11:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
pgreilic |
Date |
2018-08-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2018-08-22 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2018-08-22 15:34:42 | 1.) PROVIDE A SURVEY OR SITE PLAN CLEARLY INDICATING | | | THE AREA OF THE STRUCTURE, AND LABEL SETBACKS | | | ACCORDINGLY | | | | | | PAUL GREILICH, SENIOR PLANNER | | | 561-822-1443 | | | [email protected] |
|
|