Plan Review Details - Permit 18070210
| Plan Review Stops For Permit 18070210 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-08-13 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2018-08-13 |
Time |
17:33 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
| 2018-08-13 17:34:41 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | APPROVED PV | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-07-07 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2018-07-07 |
Time |
09:45 |
Rev Time |
|
| Received By |
pvalenti |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
| 2018-07-07 10:08:24 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | FBC 107. | | | | | | 1. PLEASE PROVIDE THE N.O.A. FOR THE MULLIONS TO BE | | | USED. | | | | | | NOTE: TYPICALLY IN THIS LOCATION, ATTACHING MULLIONS TO | | | KNEE WALLS BELOW THE WINDOWS, THE KNEE WALL STRUCTURE | | | IS NOT SUFFICIENT TO TRANSFER LOADS TO CONCRETE | | | STRUCTURE AS PER PRODUCT APPROVALS AND CODE | | | REQUIREMENTS. PLEASE CONSIDER SUBMITTING MULLIONS WITH | | | A LONGER LENGTH TO ATTACH DIRECTLY TO CONCRETE DECK | | | BELOW IF REQUIRED. | | | | | | 2. WORKERS COMP AND INSURANCE HAVE EXPIRED. PLEASE | | | UPDATE. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-08-13 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2018-08-13 |
Time |
17:34 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2018-08-10 |
Time |
14:13 |
Sent To |
I |
|
| Notes |
| 2018-08-13 14:14:02 | RESUB ROUTED TO PVALENTI |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-07-07 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2018-07-07 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2018-07-05 |
Time |
13:39 |
Sent To |
I |
|
| Notes |
| 2018-07-06 13:39:22 | BLDG <5K |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |