Plan Review Details - Permit 18070190
| Plan Review Stops For Permit 18070190 |
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2018-08-10 |
|
|
Cont ID |
|
| Sent By |
RRossano |
Date |
2018-08-10 |
Time |
00:00 |
Rev Time |
1.00 |
| Received By |
rrossano |
Date |
2018-08-10 |
Time |
00:00 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2018-07-20 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2018-07-20 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2018-07-20 |
Time |
|
Sent To |
I |
|
| Notes |
| 2018-07-20 17:26:46 | NO COMMENTS - ADDRESS FIRE DEPARTMENT COMMENTS. | | | | | | MANNY GONZALEZ | | | PROJECT COORDINATOR | | | (561) 494-1085 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-08-20 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-08-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-08-20 |
Time |
14:49 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2018-07-12 |
|
|
Cont ID |
|
| Sent By |
bwoods |
Date |
2018-07-12 |
Time |
00:00 |
Rev Time |
0.00 |
| Received By |
bwoods |
Date |
2018-07-12 |
Time |
00:00 |
Sent To |
M |
|
| Notes |
| 2018-07-12 13:59:47 | 1. NEED MORE DEFINED PLANS SPECIFED FROM POINT OF | | | SERVICE OF PLANS FOR THAT PERMIT | | | 2. DETAIL DRAWINGS OF HYDRANTS AND PIVS | | | 3. DETAIL OF ADDRESS OF BUILDING TO MATCH PERMIT | | | 4. NEEDS MANUFACTURAL SPECIFICATIONS ON PIPING AND | | | FITTINGS | | | 5. PROVIDE CONTRACTOR LICENSE | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-08-20 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-08-20 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-07-26 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2018-07-27 10:08:59 | RESUB ROUTED TO FIRE INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-07-23 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-07-23 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-07-05 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2018-07-06 14:19:43 | ROUTED TO FIRE INBOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-08-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-08-13 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-08-13 |
Time |
09:48 |
Sent To |
ENG |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-07-19 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-07-19 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-07-19 |
Time |
11:07 |
Sent To |
ENG |
|
| Notes |
| 2018-07-19 11:07:26 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #18070190 | | | 7/19/18 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE A PLAN THAT HAS THE ADDRESS OF THE | | | BUILDING, AND SITE SPECIFIC DETAILS FOR INSTALLATION OF | | | THE FIRE LINE. | | | | | | 2) PROVIDE A SUBMITTAL PACKAGE FOR THE FIRE LINE | | | MATERIALS THAT INCLUDES, BUT IS NOT LIMITED TO, | | | MANUFACTURER'S SPECIFICATIONS FOR THE UNDERGROUND | | | PIPING, PIPE FITTINGS, AND JOINT RESTRAINT SYSTEMS | | | INCLUDING MATERIAL DATA SHEETS INDICATING TORGUE WRENCH | | | SETTINGS, | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
|