Plan Review Details - Permit 18070139
Plan Review Stops For Permit 18070139
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2018-09-19 Cont ID  
Sent By shill Date 2018-09-19 Time 14:43 Rev Time 0.00
Received By shill Date 2018-09-19 Time 07:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2018-09-19 Cont ID  
Sent By shill Date 2018-09-18 Time 07:15 Rev Time 0.00
Received By shill Date 2018-09-18 Time 07:15 Sent To  
Notes
2018-09-19 07:16:05PREVIOUS COMMENTS WERE ADDRESSED, BUT REVISED PLAN
 (PRESCREEN AT FRONT COUNTER) NEEDS CLARIFICATION; SEE
 REVIEW #3.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-08-11 Cont ID  
Sent By shill Date 2018-08-11 Time 17:46 Rev Time 0.00
Received By shill Date 2018-08-11 Time 17:46 Sent To  
Notes
2018-08-11 17:48:19****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. SEE PLUMBING COMMENTS; THEY ARE APPLICABLE FOR
 BUILDING REVIEW.
  
 2. FBC 109, PROVIDE A COPY OF THE CONTRACT FOR THIS JOB
 AND A COST BREAKDOWN.
  
 3. NOTE THAT THE FOLLOWING ITEMS ARE EITHER EXPIRED OR
 SOON TO EXPIRE:
  
 GC LICENSE
 BROWARD BUSINESS TAX RECEIPT
  
 PLEASE UPDATE AT THIS TIME TO PREVENT PERMIT ISSUANCE
 DELAYS. THIS CAN BE FAXED TO 561-805-6676 OR SENT VIA
 EMAIL TO [email protected].
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2018-09-27 Cont ID  
Sent By jpearson Date 2018-09-27 Time 13:44 Rev Time 0.00
Received By jpearson Date 2018-09-27 Time 13:44 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2018-09-02 Cont ID  
Sent By jpearson Date 2018-09-02 Time 15:55 Rev Time 0.00
Received By jpearson Date 2018-09-02 Time 15:55 Sent To  
Notes
2018-09-02 15:55:05CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS
 COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY
 HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW
 COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS.
  
 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS
 LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND
 VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR FOR
 ENTIRE PROJECT. FBC 109.3 (CONTRACT PROVIDED DOES
 INCLUDE ALL WORK. PROVIDE TOTAL BREAKSOWN WITH ALL
 TRADES SHOWN. THIS MUST INCLUDE VALUE OF MATERIALS
 WHETHER THE CONTRACTOR SUPPLIES THEM OR THE OWNER
 PROVIDES.)
 2. ELECTRICAL NOTE STATES: "ALL WP OUTLETS SHALL BE
 WITH GFCI PROTECTION PER N.E.C.8.(B).3". THIS CODE
 SECTION DOES NOT EXIST. PROVIDE CORRECTION. NEC 210.8;
 WPB FBC 107.2.1 (NOTE STILL STATES WRONG CODE SECTION,
 AND THEN STATES PROPER CODE ARTICLE. CORRECT
 DISCREPANCY.)
 3. OTHER ELECTRICAL NOTE STATES: "PROSSIGERS ROOM IN
 MEDICAL FACILITIES AS PER 517.13 FBC 2017 6TH ED." THIS
 CODE SECTION DOES NOT EXIST IN THE FBC. DOES THIS NOTE
 RELATE TO PATIENT CARE AREAS AND THE REDUNDANT
 GROUNDING REQUIREMENTS OF NEC 517.13? PROVIDE
 CLARIFICAITON AND/OR CORRECTION. DO YOU MEAN PROCEDURE
 ROOMS? NOTE SHOULD CLEARLY REFLECT WHAT THE NEC STATES
 FOR THE REQUIREMENT. IDENTIFY THESE ROOMS ON PLAN. WPB
 FBC 107.2.1 (NOT CORRECTED. ROOMS NOT IDENTIFIED.)
 4. ELECTRICAL MAINS NEED TO BE GROUPED PER NEC 230.72.
 (AS THESE MAINS ARE EXISTING, PROVIDE SIGNAGE DETAILS
 TO IDENTIFY ALL MAIN LOACATIONS PER NEC 230.2(E) )
 5. IT APPEARS FROM THE RISER DIAGRAM AND PANEL
 SCHEDULES THAT THERE IS NOT A MAIN DISCONNECT FOR EACH.
 AN UNGROUNDED CONDUCTOR IS NOT PERMITTED TO ENTER A
 BUIDLING WITHOUT OVERCURRENT AND DISCONNECTING MEANS,
 GREATER THAN 8 FEET. PROVIDE CORRECTION. NEC 230.70
 (RISER DIAGRAM WAS REMOVED FROM PLAN. PROVIDE RISER
 DETAIL, SHOWING ALL ASPECTS OF EXISTING SERVICE. NEC
 215.5)
 6. CORRECTED, EXISTING SERVICE AND PANELS.
 7. CORRECTED, EXISTING SERVICE AND PANELS.
 8. PROVIDE CHART OF INTERIOR LIGHTING POWER ALLOWANCES
 EXPRESSED IN WATTAGE PER THE FBC ENERGY CODE IN
 RELATION TO THE WATTAGE OF THE CONNECTED INTERIOR
 LIGHTING PROPOSED TO COMPLY WITH CODE. FBC EC C405.4.2
 (NOT PROVIDED.)
 9. PROVIDE THE ADDITIONAL INTERIOR LIGHTING CONTROLS
 STIPULATED IN THE FBC ENERGY CODE. MANY AREAS DO NOT
 SHOW THE AUTOMATIC CONTROL REQUIRED. FBC EC C405.2 (NOT
 PROVIDED.)
 10. PROVIDE SHOW WINDOW RECEPTACLE OUTLETS PER NEC
 210.62. (DO NOT KNOW IF COMPLIED OR NOT BECAUSE PANEL
 SCHEDULES WERE REMOVED FROM PLAN.)
 11. CORRECTED.
 12. CORRECTED.
 13. CORRECTED.
 14. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE AND
 FOR EACH PANEL. DEMAND FACTORS PERMITTED IN RESIDENTIAL
 INSTALLATIONS ARE NOT PERMITTED FOR COMMERCIAL
 INSTALLATIONS. NEC 220 (NOT PROVIDED.)
  
 NEW COMMENTS:
  
 15. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR
 ALTERED CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE
 CIRCUITS, AND AFCI OR GFCI PROTECTION WHERE APPLICABLE
 TO COMPLY WITH CODE. NEC 210.8, 210.12, 210.19, 210.20,
 215.5, 408.4
 16. PLEASE BE ADVISED THAT SOME OF THESE COMMENTS HAVE
 NOT BEEN ADDRESSED FOR TWO REVIEWS. IF UPON THE THIRD
 REVIEW, IF IT IS NECESSARY TO REJECT THE SUBMITTED PLAN
 A THIRD TIME FOR THE SAME REASONS, AN ADDITIONAL PLAN
 REVIEW IS REQUIRED. FLORIDA STATUTES STATE: WITH
 RESPECT TO EVALUATION OF DESIGN PROFESSIONALS
 DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN
 ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING
 CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS
 REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO
 CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY
 NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO,
 EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY,
 ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL,
 MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER
 REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING
 COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL
 GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH
 REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION,
 A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE
 PERMIT FEE ATTRIBUTED TO PLANS REVIEW. FS 553.80(2)(B)
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD
 SHEETS?.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-07-30 Cont ID  
Sent By jpearson Date 2018-07-30 Time 12:53 Rev Time 0.00
Received By jpearson Date 2018-07-30 Time 10:21 Sent To  
Notes
2018-07-30 12:53:02CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS
 LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND
 VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR FOR
 ENTIRE PROJECT. FBC 109.3
 2. ELECTRICAL NOTE STATES: "ALL WP OUTLETS SHALL BE
 WITH GFCI PROTECTION PER N.E.C.8.(B).3". THIS CODE
 SECTION DOES NOT EXIST. PROVIDE CORRECTION. NEC 210.8;
 WPB FBC 107.2.1
 3. OTHER ELECTRICAL NOTE STATES: "PROSSIGERS ROOM IN
 MEDICAL FACILITIES AS PER 517.13 FBC 2017 6TH ED." THIS
 CODE SECTION DOES NOT EXIST IN THE FBC. DOES THIS NOTE
 RELATE TO PATIENT CARE AREAS AND THE REDUNDANT
 GROUNDING REQUIREMENTS OF NEC 517.13? PROVIDE
 CLARIFICAITON AND/OR CORRECTION. DO YOU MEAN PROCEDURE
 ROOMS? NOTE SHOULD CLEARLY REFLECT WHAT THE NEC STATES
 FOR THE REQUIREMENT. IDENTIFY THESE ROOMS ON PLAN. WPB
 FBC 107.2.1
 4. ELECTRICAL MAINS NEED TO BE GROUPED PER NEC 230.72.
 5. IT APPEARS FROM THE RISER DIAGRAM AND PANEL
 SCHEDULES THAT THERE IS NOT A MAIN DISCONNECT FOR EACH.
 AN UNGROUNDED CONDUCTOR IS NOT PERMITTED TO ENTER A
 BUIDLING WITHOUT OVERCURRENT AND DISCONNECTING MEANS,
 GREATER THAN 8 FEET. PROVIDE CORRECTION. NEC 230.70
 6. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH
 PANEL INCLUDING INFORMATION FROM THE POWER COMPANY
 STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR
 THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE
 SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE.
 NEC 110.9, 110.10
 7. PROVIDE AIC RATING OF SERVICE DISCONNECT AND PANEL.
 NEC 110.3, 110.9
 8. PROVIDE CHART OF INTERIOR LIGHTING POWER ALLOWANCES
 EXPRESSED IN WATTAGE PER THE FBC ENERGY CODE IN
 RELATION TO THE WATTAGE OF THE CONNECTED INTERIOR
 LIGHTING PROPOSED TO COMPLY WITH CODE. FBC EC C405.4.2
 9. PROVIDE THE ADDITIONAL INTERIOR LIGHTING CONTROLS
 STIPULATED IN THE FBC ENERGY CODE. MANY AREAS DO NOT
 SHOW THE AUTOMATIC CONTROL REQUIRED. FBC EC C405.2
 10. PROVIDE SHOW WINDOW RECEPTACLE OUTLETS PER NEC
 210.62.
 11. PROVIDE GFCI PROTECTED OUTLET FOR SERVICING OF A/C
 EQUIPMENT WITHIN 25 FEET OF THE EQUIPMENT PER CODE. NEC
 210.63
 12. PROVIDE THE REQUIRED SERVICE AREA RECEPTACLE PER
 CODE. NEC 210.64
 13. PROVIDE DEDICATED CIRCUIT AND CONTROL FOR SIGN. NEC
 600.5; FBC EC 405.2.4
 14. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE AND
 FOR EACH PANEL. DEMAND FACTORS PERMITTED IN RESIDENTIAL
 INSTALLATIONS ARE NOT PERMITTED FOR COMMERCIAL
 INSTALLATIONS. NEC 220
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD
 SHEETS?.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2018-08-27 Cont ID  
Sent By pleduc Date 2018-08-27 Time   Rev Time 0.00
Received By pleduc Date 2018-08-27 Time 12:12 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2018-07-10 Cont ID  
Sent By pleduc Date 2018-07-10 Time   Rev Time 0.00
Received By pleduc Date 2018-07-09 Time 11:58 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-10-02 Cont ID  
Sent By gjohnson Date 2018-10-02 Time 12:22 Rev Time 0.00
Received By gjohnson Date 2018-09-18 Time 15:24 Sent To  
Notes
2018-09-19 15:24:28B27

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-09-19 Cont ID  
Sent By shill Date 2018-09-18 Time 08:49 Rev Time 0.00
Received By shill Date 2018-08-23 Time 15:39 Sent To  
Notes
2018-08-24 15:39:40B09

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-08-11 Cont ID  
Sent By shill Date 2018-08-11 Time 17:51 Rev Time 0.00
Received By shill Date 2018-07-03 Time 13:14 Sent To  
Notes
2018-07-06 13:14:18B18

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2018-09-28 Cont ID  
Sent By ccole Date 2018-09-28 Time 15:02 Rev Time 0.00
Received By ccole Date 2018-09-28 Time 14:50 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2018-09-04 Cont ID  
Sent By ccole Date 2018-09-04 Time 16:38 Rev Time 0.00
Received By ccole Date 2018-09-04 Time 16:38 Sent To  
Notes
2018-09-04 16:55:402ND REVIEW FBC-2017 MECHANICAL
 PERMIT #18070139
 9/4/18
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC R- FLORIDA RESIDENTIAL CODE SIXTH EDITION 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M-1: REMOVE THE OUTDATED ASHRAE 62-89
 REFERENCE FROM THE OUTSIDE AIR CALCULATIONS.
  
 2) M-1: THE SQUARE FOOTAGE CALCULATIONS USED TO
 DETERMINE THE OUTSIDE AIR TO BE PROVIDED TO THE
 RECEPTION AND WAITING AREAS APPEAR TO BE LESS THAN THE
 ACTUAL SQ. FOOTAGES PER THE DIMENSIONS OF THE AREAS
 SHOWN ON SHEET A-1. PLEASE PROVIDE AN ACCURATE
 CALCULATION- TABLE 403.3.1.1
  
 3) M-1: CORRIDORS SHALL NOT BE USED AS A MEANS OF
 RETURNING AIR- SECTION 601.2 FBC M.
  
 4) M-1: CORRECT OR REMOVE THE AHU/CLOSET DETAIL- THE
 AHU IS SHOWN ABOVE THE CEILING ON THE PLAN.
  
 5) THE ENERGYGAUGE SUBMITTAL IS INCOMPLETE. ONLY THE
 INPUT DATA REPORT HAS BEEN PROVIDED. PLEASE PROVIDE THE
 COVER SHEETS, CERTIFICATIONS SHEETS, COMPLIANCE DATA
 SHEETS, AND THE CHECKLISTS WHICH COMPRISE THE 1ST PART
 OF THE SUBMITTAL.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-07-16 Cont ID  
Sent By ccole Date 2018-07-16 Time 17:29 Rev Time 0.00
Received By ccole Date 2018-07-16 Time 17:08 Sent To  
Notes
2018-07-16 17:45:461ST REVIEW FBC-2017 MECHANICAL
 PERMIT #18070139
 7/16/18
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC R- FLORIDA RESIDENTIAL CODE SIXTH EDITION 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) REFER TO SECTION 809.2 FBC-17 EXISTING BUILDING CODE
 AND PROVIDE MINIMUM VENTILATION CALCULATIONS FOR ALL
 ROOMS AND SPACES PER TABLE 403.3.1.1. FBC-17
 MECHANICAL. PROVIDE A SCHEDULE THAT INDICATES THE
 REQUIRED AND PROVIDED CFMS OF OUTDOOR AIR.
  
 2) NO RETURN AIR SYSTEM IS SHOWN ON THE PLANS, PLEASE
 PROVIDE A MEANS OF RETURN AIOR FROM THE ROOMS AND
 SPACES BACK TO THE AIR HANDLER- SECTION 601.6 FBC M.
  
 3) THE PROPOSED PROJECT IS CLASSIFIED AS A "CHANGE OF
 OCCUPANCY" AS DEFINED IN SECTION 202 FBC EX. PLEASE
 SUBMIT A COMPLETE ENERGY COMPLIANCE REPORT AS REQUIRED
 BY SECTION C505.1 FBC EC. THE CURRENT SUBMITTALS IS
 LACKING THE COVER SHEET, CERTIFICATIONS PAGE,
 COMPLIANCE REPORT, AND CHECKLISTS- SEE SECTION C101.5.1
 FBC EC.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2018-10-02 Cont ID  
Sent By gjohnson Date 2018-10-02 Time 12:22 Rev Time 0.00
Received By gjohnson Date 2018-10-02 Time 12:01 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2018-09-13 Cont ID  
Sent By gjohnson Date 2018-09-13 Time 12:03 Rev Time 0.00
Received By gjohnson Date 2018-09-13 Time 10:50 Sent To  
Notes
2018-09-13 12:26:302ND REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. DUE TO THE INCREASED OCCUPANT LOAD BY COMBINING THE
 TENANT SPACES IT IS REQUIRED TO HAVE A WATER FOUNTAIN
 COMPLYING WITH FBC ACC 211.2 AND A SERVICE SINK. PER
 FBC EX 810.1 AND FBC PL TABLE 403.1
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-08-09 Cont ID  
Sent By gjohnson Date 2018-08-09 Time 13:19 Rev Time 0.00
Received By gjohnson Date 2018-08-09 Time 11:20 Sent To  
Notes
2018-08-09 14:20:161ST REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. SHT. 5 OF 11 WHY IS THERE 3 DIFFERENT HANDICAP
 BATHROOM DETAILS I FOUND THE FOLLOWING CODE VIOLATIONS.
 A) THE BOTTOM 2 DETAILS SHOW THE TOILET SEAT AT 15" IT
 SHALL BE 17"- 19" PLEASE CLARIFY PER FBC ACC 604.4
 B) THE GRAB BARS SHALL BE MEASURED TO THE TOP OF THE
 GRIPPING SURFACE FROM FINISHED FLOOR AT 33"-36" PER FBC
 ACC 609.4
 C) THE DETAIL ON THE TOP OF THE PAGE FOR THE LAVATORY
 SHOWS THE TOP OF THE RIM AT 35" IT SHALL BE 34" PER FBC
 ACC 606.3
 D THE REAR WALL GRAB BAR SHALL BE 36 INCHES LONG
 MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER
 CLOSET 12 INCHES MINIMUM ON ONE SIDE AND 24 INCHES
 MINIMUM ON THE OTHER SIDE. PER FBC ACC 604.5.2
  
 2. SHOW THE LOCATIONOF THE NEW WATER HEATER SHOWN ON
 SHT. 7 OF 11. PER WPB AMEND TO FBC 107.2.1
  
 3. IS THE WATER HEATER REPACLING AN EXITING ONE OR IS
 IT A NEW INSTALLATION IF IT IS A NEW INSTALLATION IT
 SHALL COMPLY WITH FBC PL 416.5 TEMPERED WATER SHALL BE
 DELIVERED FROM LAVATORIES AND GROUP WASH FIXTURES
 LOCATED IN PUBLIC TOILET FACILITIES PROVIDED FOR
 CUSTOMERS, PATRONS AND VISITORS. TEMPERED WATER SHALL
 BE DELIVERED THROUGH AN APPROVED WATER-TEMPERATURE
 LIMITING DEVICE THAT CONFORMS TO ASSE 1070 OR CSA
 B125.3.
  
 4. SHT. 2 OF 11 HAS DETAIL FOR A SLAB REPAIR IS THERE
 NEW PLUMBING PIPES BEING INSTALLED PLEASE CLARIFY. PER
 WPB AMEND TO FBC 107.2.1
  
 5. SHT. 7 OF 11 HAS SEVERAL NOTES, TABLES AND DETAILS
 REFERENCING SEVERAL DIFFERENT PLUMBING FIXTURES AND
 PIPING THAT ARE NOT ON THE FLOOR PLAN AND NOT SHOWN ON
 THE SCOPE OF WORK IT IS UNCLEAR OF WHAT PLUMBING WORK
 IS BEING DONE PLEASE PROVIDE A DETAIL SCOPE OF PLUMBING
 WORK THAT IS BEING DONE AND PROVIDE PIPING ISOMETRICS
 FOR NEW PIPING. PLEASE CLARIFY. PER WPB AMEND TO FBC
 107.2.1
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  