| Plan Review Stops For Permit 18070117 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-10-17 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-10-17 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-10-17 |
Time |
08:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-08-21 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-08-21 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-08-21 |
Time |
13:16 |
Sent To |
|
|
| Notes |
| 2018-08-21 13:17:48 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 18070117 | | | REVIEWED: AUGUST 20, 2018 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER I | | | [email protected] | | | 561-805-6718 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC EB = FBC EXISTING BUILDING | | | FBC R = FBC RESIDENTIAL | | | | | | 1. [FBC R107]PROVIDE SURVEY OF PROPERTY. | | | | | | 2. [FBC AMENDED 107]ADD ROOF PITCH TO PLANS. | | | | | | 3. [FBC AMENDEDWHAT IS EXISTING ROOFING MATERIAL, AND | | | WHAT IS PROPOSED? | | | | | | 4. WHAT ARE THE LOADS ON NEW ROOF? | | | | | | 5. [FBC R301.2.1] WIND DESIGN CRITERIA. PROVIDE DESIGN | | | PRESSURES FOR WINDOW AND DOOR. | | | PAGE 1 OF WINDOW AND DOOR PRODUCT APPROVALS ARE IN | | | PERMIT, BUT PLEASE PROVIDE THE FULL PRODUCT APPROVAL | | | FOR EACH. | | | | | | 6. [FBC R803.2.3.1]SHEATHING FASTENING. | | | SHEATHING NAILS TO BE RING SHANK RSRS01(2 3/8 X 0.113) | | | PROVIDE PRODUCT APPROVALS FOR ROOFING, OR INDICATE THAT | | | THEY WILL BE DEFFERED. | | | | | | 7. [FBC R318.1] TERMITE PROTECTION. | | | TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED | | | TERMITICIDES, INCLUDING SOIL APPLIED PESTICIDES, | | | BAITING SYSTEMS, AND PESTICIDES APPLIED TO WOOD, OR | | | OTHER APPROVED METHODS OF TERMITE PROTECTION LABELED | | | FOR USE AS A PREVENTATIVE TREATMENT TO NEW | | | CONSTRUCTION. SEE SECTION 202, ?REGISTERED | | | TERMITICIDE.? UPON COMPLETION OF THE APPLICATION OF THE | | | TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF | | | COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT | | | BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE | | | FOLLOWING STATEMENT: ?THE BUILDING HAS RECEIVED A | | | COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN | | | TERMITES. TREATMENT IS IN ACCORDANCE WITH RULES AND | | | LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF | | | AGRICULTURE AND CONSUMER SERVICES.? | | | | | | 8. [FBC R107]PROVIDE WALL TYPE DETAIL. I SEE 2X6 WALL | | | WITH 19/32 CDX, BUT WHAT ARE THE FINISHES ON INTERIOR | | | AND EXTERIOR OVER THE PLYWOOD? | | | | | | 9. [FBC R806]WHAT TYPE OF INSULATION IS BEING INSTALLED | | | IN THE NEW ATTIC, AND HOW IS IT VENTED? | | | | | | NOTE: | | | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | | OF MATERIALS REQUESTED. | | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-11-15 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-11-15 |
Time |
07:01 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-11-15 |
Time |
06:47 |
Sent To |
G |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-10-02 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-10-02 |
Time |
07:26 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-10-02 |
Time |
06:36 |
Sent To |
|
|
| Notes |
| 2018-10-02 07:27:12 | SUBMIT PANEL SCHEDULE BEFORE FINAL |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-08-01 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-08-01 |
Time |
06:59 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-08-01 |
Time |
06:33 |
Sent To |
|
|
| Notes |
| 2018-08-01 06:59:06 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE RISER DIAGRAM OF EXISTING RESIDENTIAL | | | SERVICE. NEC 220.16A1&2, 220.12, 220.14, FBC RE | | | E3602.1, FBC RE E3602.2 | | | | | | 2. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS. NEC 220; FBC RE E3602.2 | | | | | | 3. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4; WPB FBC | | | 107.3.5; FBC RE E3706.2, E3902 | | | | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WPB | | | [email protected] | | | CELL: 561-657-1653 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2018-11-21 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-11-19 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-11-19 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2018-11-19 15:04:12 | NO GAS, PER CUSTOMER THE GAS DRYER IS NOW ELECTRIC. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-10-16 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-10-16 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-10-16 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2018-10-16 15:29:51 | 10/16/2018 1ST GAS REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. SHOW THE TYPE OF PIPE MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE CORRESPONDING EHD NUMBER OF THE | | | CORRUGATED STAINLESS STEEL TUBING (IF APPLICABLE) FOR | | | EACH PIPE SIZE. WPB AMENDMENTS TO THE FBC SEC.107.2.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 2. SUBMIT COMPLETE MANUFACTURER'S SPECIFICATIONS FOR | | | THE GAS DRYER. THE GAS DRYER SHALL BE LISTED AND | | | LABELED PER THE 2017 FBC FUEL GAS SEC.301.3 OR 2017 FBC | | | FUEL GAS RES. SEC. G2404.3. THE MANUFACTURER'S | | | SPECIFICATIONS SHALL NOTE THE CFM'S THAT ARE BEING | | | EXHAUSTED BY THE DRYER. | | | | | | 3. SUBMIT COMBUSTION AIR CALCULATIONS FOR THE GAS | | | APPLIANCES. WHERE IS COMBUSTION AIR PROVIDED BY THE | | | BUILDING?S MECHANICAL VENTILATION SYSTEM, THE SYSTEM | | | SHALL PROVIDE THE SPECIFIED COMBUSTION AIR RATE IN | | | ADDITION TO THE REQUIRED VENTILATION AIR? 2017 FBC R | | | G2407.9.3. COMBINED COMBUSTION AIR AND VENTILATION AIR | | | SYSTEM. | | | | | | 4. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE, | | | TERMINATION POINT, HEIGHT ABOVE THE ROOF AND ANCHORING | | | DETAILS OF THE GAS VENT(S) PER 2017 FBC FUEL GAS SECS. | | | 502 THRU 505 OR 2017 FBC FUEL GAS RES. SECS. G2426 THRU | | | G2429.1. | | | | | | 5. SUBMIT TWO COPIES OF THE APPLICABLE SIZING TABLES | | | USED TO SIZE THE GAS SYSTEM OR PLACE A NOTE ON THE | | | PLANS/DRAWINGS SPECIFYING WHICH SIZING TABLE(S) FROM | | | THE GAS CODE OR ANOTHER STANDARD THAT WAS USED IN THE | | | DESIGN OF THIS GAS SYSTEM. REFER TO THE 2017 FBC FUEL | | | GAS RES. SEC. G2412.4, G2412.8, G2413.1, G2413.2, & | | | G2413.3. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | | [email protected] | | | 561-805-6720 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-10-12 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-10-12 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-10-12 |
Time |
16:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-07-19 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-07-19 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-07-19 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2018-07-19 10:20:32 | ADDITION AND WINDOW CHANGE REQUIRES SUBMITTAL OF COA. | | | QUESTIONS, CONTACT FRIEDERIKE MITTNER, CITY HISTORIC | | | PRESERVATION PLANNER AT (561) 822-1457 OR | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-11-19 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-11-19 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-11-06 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2018-11-07 15:34:21 | RESUB ROUTED TO FGIAQUINTO |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-10-17 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-10-17 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-09-13 |
Time |
15:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-08-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-30 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-03 |
Time |
16:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2018-10-17 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-10-17 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-10-17 |
Time |
08:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2018-08-21 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-08-21 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-08-21 |
Time |
13:26 |
Sent To |
|
|
| Notes |
| 2018-08-21 13:27:33 | [FBC AMENDED 109] PLANS REQUIRE REVIEW BY THE PBC | | | IMPACT FEE OFFICE. CALL (561) 233-5025. UPON APPROVAL, | | | YOU MAY CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE | | | FOR REVIEW. PLEASE RETURNED STAMPED AND WITH A COPY OF | | | THE RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE | | | OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO | | | V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN | | | AIRE.PDF |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-10-13 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-10-13 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-10-13 |
Time |
08:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-08-04 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-08-04 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-08-04 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2018-08-04 11:00:49 | NO AIR CONDITIONING PLAN SUBMITTED WITH PACKAGE HM. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-10-16 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-10-16 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-10-16 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2018-10-16 15:31:51 | 10/16/18 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVE PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-08-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-30 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-08-30 |
Time |
11:37 |
Sent To |
|
|
| Notes |
| 2018-08-30 11:53:37 | PERMIT 18070117 | | | PLUMBING | | | 1ST REVIEW 8/30/18 | | | | | | PROVIDE CODE COMPLIANT PLUMBING RISER DIAGRAM IN | | | ACCORDANCE WITH 2017 FBC 107.3.5.3 (12) WPB AMEND | | | INCUDE CONNECTION TO EXISTING SANITARY PIPING SHOWING | | | THAT IT WILL NOT CONNECT TO EXISTING VENTS IN | | | ACCORDANCE WITH 2017 FBC RESIDENTIAL CHAPTER 31 | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2018-10-17 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-10-17 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-10-17 |
Time |
08:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-08-21 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-08-21 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-08-21 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2018-08-21 13:29:57 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 18070117 | | | REVIEWED: AUGUST 20, 2018 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER I | | | [email protected] | | | 561-805-6718 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC EB = FBC EXISTING BUILDING | | | FBC R = FBC RESIDENTIAL | | | | | | 1. PROVIDE PRODUCT APPROVALS. | | | SEE BUILDING COMMENTS FOR ADDITIONAL COMMENTS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-10-04 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-10-04 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-10-04 |
Time |
10:50 |
Sent To |
HIST |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-07-13 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-07-13 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-07-13 |
Time |
08:46 |
Sent To |
|
|
| Notes |
|
|