| Plan Review Stops For Permit 18070063 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2018-07-31 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-07-31 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-07-31 |
Time |
11:37 |
Sent To |
|
|
| Notes |
| 2018-07-31 13:05:14 | | | | ****PROVISOS REMAINDER: | | | | | | | | | REVISION #18040403 PROVISO: | | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.001 FOR THE BEAD BOARD SOFFIT SPECIFIED ON | | | PLANS/SECTIONS. | | | | | | 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | ORIGINAL BUILDING REVIEW PROVISO: | | | 1- PROVIDE MANUFACTURER'S DETAILS & SPECS FOR FACTORY | | | BUILT FIREPLACE & CLAY FLUE SPECIFIED ON FLOOR PLANS | | | AND SHEET A.13. SHOW COMPLIANCE WITH UL 127. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-08-21 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-08-21 |
Time |
07:42 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-08-21 |
Time |
07:42 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-07-26 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-07-26 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-07-26 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2018-07-26 15:21:24 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. A GFCI PROTECTED RECEPTACLE OUTLET ON A 20 AMP | | | CIRCUIT IS REQUIRED WITHIN 3 FEET OF EACH BASIN. | | | PROVIDE CORRECTION FOR HER BATH. NEC 210.11(C)(3), | | | 210.52(D); FBC RE E3703.4, E3901.6 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2018-08-15 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-08-15 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-08-15 |
Time |
12:37 |
Sent To |
|
|
| Notes |
| 2018-08-15 12:38:11 | GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN | | | THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN | | | PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS | | | WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE | | | RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT | | | REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE. AT | | | THIS TIME. WPB AMENDMENTS TO FBC SEC. 107.2.1. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-08-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-08-16 |
Time |
15:36 |
Sent To |
|
|
| Notes |
| 2018-08-17 15:36:46 | RESUB ROUTED TO JPEARSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-08-15 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-08-15 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-07-02 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2018-08-15 08:22:34 | 8/15 TO LC DESK | | | | | 2018-07-03 15:11:26 | R03 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2018-08-15 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-08-15 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-08-15 |
Time |
13:46 |
Sent To |
|
|
| Notes |
| 2018-08-15 13:49:35 | 08/15/18 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVE PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
pgreilic |
Date |
2018-07-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2018-07-06 |
Time |
14:47 |
Sent To |
|
|
| Notes |
|
|