Plan Review Details - Permit 18070050
Plan Review Stops For Permit 18070050
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-09-02 Cont ID  
Sent By shill Date 2018-09-02 Time 10:03 Rev Time 0.00
Received By shill Date 2018-09-02 Time 10:03 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-07-21 Cont ID  
Sent By shill Date 2018-07-21 Time 14:28 Rev Time 0.00
Received By shill Date 2018-07-21 Time 14:28 Sent To  
Notes
2018-07-21 14:29:54****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. FBC R 301, A1.1, REVISE INFILL DETAIL TO INCLUDE
 MINIMUM EMBEDMENT. NO EMBEDMENT IS SHOWN GRAPHICALLY.
  
 2. FBC R 301, REVISE PLAN TO INCLUDE WIND DESIGN
 CRITERIA.
  
 3. FBC 107, PLAN PAGES WERE UPLOADED TO BOTH SUPPORTING
 DOCUMENTS AND DRAWINGS. PLAN PAGES SHOULD BE IN
 DRAWINGS ONLY, REMOVE THE DUPLICATED SHEETS IN
 SUPPORTING DOCUMENTS.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-08-28 Cont ID  
Sent By jpearson Date 2018-08-28 Time 08:16 Rev Time 0.00
Received By jpearson Date 2018-08-28 Time 08:16 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-07-23 Cont ID  
Sent By jpearson Date 2018-07-23 Time 14:38 Rev Time 0.00
Received By jpearson Date 2018-07-23 Time 14:38 Sent To  
Notes
2018-07-23 14:37:58CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. ELECTRICAL POWER WIRING NOTES STATE THAT #12 WIRE
 SHOULD BE USED FOR ALL CIRCUITS, NOTE # 2 STATES THAT
 ALL BREAKERS WILL BE 20 AMP. HOWEVER, IN EACH OF THESE
 LOCATIONS IT STATES THAT # 14 WIRE IS ACCEPTABLE.
 NUMBER 14 ROMEX IS NOT RATED FOR 20 AMPS. PROVIDE
 CORRECTION. NEC 310.15(B)(16), NEC 334.80; FBC RE
 E3705.4.4
 2. AFCI NOTE PROVIDED IS NOT CODE COMPLIANT. ALL BRANCH
 CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- AND
 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY ROOMS,
 DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS,
 BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS,
 HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS
 SHALL BE AFCI PROTECTED. PROVIDE CORRECTION. NEC
 210.12; FBC RE E3902.16
 3. PLAN SHOWS A CHANDELIER OVER TUB. NO PARTS OF
 CORD-CONNECTED LUMINAIRES, CHAIN-, CABLE-, OR
 CORD-SUSPENDED LUMINAIRES, LIGHTING TRACK, PENDANTS, OR
 CEILING-SUSPENDED (PADDLE) FANS SHALL BE LOCATED WITHIN
 A ZONE MEASURED 3 FEET HORIZONTALLY AND 8 FEET
 VERTICALLY FROM THE TOP OF THE BATHTUB RIM OR SHOWER
 STALL THRESHOLD. PROVIDE CORRECTION. NEC 410.10(D); FBC
 RE E4003.11
 4. A GFCI PROTECTED RECEPTACLE OUTLET ON A 20 AMP
 CIRCUIT IS REQUIRED WITHIN 3 FEET OF EACH BASIN.
 PROVIDE CORRECTION. NEC 210.11(C)(3), 210.52(D); FBC RE
 E3703.4, E3901.6
 5. GFCI PROTECTION IS REQUIRED FOR ALL RECEPTACLE
 OUTLETS IN BATHROOM. PROVIDE CORRECTION. NEC 210.8; FBC
 RE E3902.1
 6. GFCI AND AFCI PROTECTION IS IS REQUIRED FOR ALL
 RECEPTACLE OUTLETS IN LAUNDRY AREA. PROVIDE CORRECTION.
 NEC 210.8, 210.12; FBC RE E3902.9, 3902.16
 7. PLAN SHOWS A STANDARD RECESS LIGHT OVER SHOWER.
 LIGHTING IN BATHTUB OR SHOWER AREAS SHALL BE SUITABLE
 FOR DAMP LOCATIONS. PROVIDE CORRECTION. NEC 410.10(D);
 FBC RE E4003.11
 8. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED
 PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING
 ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS
 NEW INSTALLATIONS. FBC RE R314.3, R315.1; WPB FBC
 107.2.1
 9. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED
 CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS,
 AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY
 WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5,
 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2018-09-04 Cont ID  
Sent By gjohnson Date 2018-09-04 Time 11:01 Rev Time 0.00
Received By gjohnson Date 2018-09-04 Time 11:01 Sent To  
Notes
2018-09-04 11:02:37GAS PLAN REVIEW
 A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT
 THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE
 REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK.
 PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT
 SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE
 SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC.
 107.2.1.
  
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE
 FBC-R, SEC. G2404.3.
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL
 GAS SEC. 301.3.
  
 A SEPARATE PERMIT AND PLANS IS REQUIRED FOR THE GAS
 INSTALLATION OR MODIFICATION OF SYSTEM.
  
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-09-13 Cont ID  
Sent By cthroop Date 2018-09-13 Time 07:58 Rev Time 0.00
Received By cthroop Date 2018-09-07 Time 13:17 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-09-04 Cont ID  
Sent By gjohnson Date 2018-09-04 Time 11:03 Rev Time 0.00
Received By gjohnson Date 2018-08-13 Time 07:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-08-02 Cont ID  
Sent By gjohnson Date 2018-08-02 Time 12:05 Rev Time 0.00
Received By gjohnson Date 2018-07-03 Time 10:16 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2018-07-31 Cont ID  
Sent By hmoser Date 2018-07-31 Time 11:48 Rev Time 0.00
Received By hmoser Date 2018-07-31 Time 11:34 Sent To  
Notes
2018-07-31 11:50:44NO AIR CONDITIONING WORK BEING DONE AT THIS TIME HM.

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-09-04 Cont ID  
Sent By gjohnson Date 2018-09-04 Time 10:27 Rev Time 0.00
Received By gjohnson Date 2018-09-02 Time 11:02 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-08-02 Cont ID  
Sent By gjohnson Date 2018-08-02 Time 11:46 Rev Time 0.00
Received By gjohnson Date 2018-08-02 Time 11:46 Sent To  
Notes
2018-08-02 12:04:591ST REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. PLEASE PROVIDE A SANITARY ISOMETRIC FOR RECONFIGURED
 LAUNDRY ROOM WITH DOG WASH SHOWER. PER WPB AMEND TO FBC
 107.3.5.3(12)
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2018-09-13 Cont ID  
Sent By cthroop Date 2018-09-13 Time 07:58 Rev Time 0.00
Received By cthroop Date 2018-09-13 Time 07:52 Sent To  
Notes
2018-09-13 07:59:529/13/18 APPROVED AND SENT TO STORAGE. CT
2018-09-07 13:17:289/7/18 HARD COPIES ROUTED TO SHILL

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2018-08-28 Cont ID  
Sent By jpearson Date 2018-08-28 Time 08:17 Rev Time 0.00
Received By jpearson Date 2018-08-28 Time 08:17 Sent To  
Notes
2018-08-28 08:17:30****CORRECTIONS****
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. THE DOCUMENTS SUBMITTED ARE NOT DIGITALLY SIGNED AND
 SEALED IN ACCORDANCE WITH FS481.
  
 PLEASE EITHER UPLOAD DIGITALLY SIGNED AND SEALED
 DOCUMENTS OR PROVIDE ONE PAPER ORIGINAL. IF PROVIDING
 PAPER, THIS SHOULD BE DONE AFTER ALL OTHER REVIEWS HAVE
 PASSED.
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2018-07-21 Cont ID  
Sent By shill Date 2018-07-21 Time 14:33 Rev Time 0.00
Received By shill Date 2018-07-21 Time 14:33 Sent To  
Notes
2018-07-21 14:34:28****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. THE DOCUMENTS SUBMITTED ARE NOT DIGITALLY SIGNED AND
 SEALED IN ACCORDANCE WITH FS481.
  
 PLEASE EITHER UPLOAD DIGITALLY SIGNED AND SEALED
 DOCUMENTS OR PROVIDE ONE PAPER ORIGINAL. IF PROVIDING
 PAPER, THIS SHOULD BE DONE AFTER ALL OTHER REVIEWS HAVE
 PASSED.
  
  
  