Plan Review Details - Permit 18070030
| Plan Review Stops For Permit 18070030 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2019-03-28 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-03-28 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-03-28 |
Time |
16:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2019-03-27 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-03-27 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-03-27 |
Time |
08:53 |
Sent To |
|
|
| Notes |
| 2019-03-27 09:06:59 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | APPROVED WITH PROVISOS AS NOTED BELOW IN ITEMIZED LIST: | | | | | | 1. APPROVED. | | | | | | 2.A. APPROVED WITH PROVISO: REVISE PLANS TO CORRECT | | | OCCUPANCY CAPACITY AS PER FBC B TABLE 1004.1.2. FOR 2ND | | | LEVEL STORAGE ROOMS AND 1ST FLOOR ROOM. (NOTE: PLUMBING | | | REVIEWER ACCEPTED NUMBER OF FIXTURES PER OCCUPANCY | | | LOAD). | | | C. APPROVED WITH PROVISO: PROVIDE LETTER STATING THAT | | | ADJACENT BUILDING IS COMPLYING WITH REQUIREMENT FOR | | | REMOVAL OF WINDOW. EXTERIOR STAIR AT WEST WALL NEEDS TO | | | BE 10? FROM ADJACENT BUILDING WINDOW. | | | | | | 3. THROUGH 6. APPROVED | | | | | | 7. APPROVED WITH PROVISO: SEPARATE SPRINKLER PERMIT | | | REQUIRED, LEVEL 2 APPEARS TO BE OK. LEVEL 1 EXCEEDS THE | | | ALLOWABLE QUANTITY (120 GALLONS) OF 1B, SO THIS CHANGES | | | FROM F1 TO H3. | | | | | | 8. THROUGH 14. APPROVED | | | | | | 15.(1) APPROVED WITH PROVISO: ARCHITECT NEEDS TO | | | PROVIDE NEW DETAIL FOR COUNTER TOP IN ACCORDANCE WITH | | | ACCESSIBILITY REQUIREMENTS. 1ST LEVEL CABINET BASE | | | DETAIL SHOWS TOP OF COUNTER AT 34?. THIS SHOULD BE NO | | | HIGHER THAN 30? AND NEEDS LEG ROOM FOR WHEEL CHAIR | | | FRONT APPROACH. | | | (2) THROUGH (4) APPROVED | | | | | | 16. APPROVED WITH PROVISO: A CLARIFICATION OF VALUATION | | | BREAK DOWN IS REQUIRED FROM CONTRACTOR. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2018-11-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-11-13 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-11-08 |
Time |
17:53 |
Sent To |
|
|
| Notes |
| 2018-11-13 10:13:43 | 3RD REVIEW FBC-2017 BUILDING | | | PERMIT #18070030 | | | 415 SOUTHERN BLVD. | | | TYPE OF CONSTRUCTION: II B | | | OCCUPANCY TYPE: F-1 | | | SPRINKLERED BLDG: NO | | | LEVEL OF ALTERATION: LEVEL III ALTERATION, CHANGE OF | | | OCCUPANCY | | | | | | CODES IN EFFECT: | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) COMPLIED. | | | | | | 2) PARTIALLY COMPLIED. SEE NEW COMMENTS REGARDING LIFE | | | SAFETY PLANS. | | | A) WHEN DETERMINING OCCUPANT LOADS PER FBC 1004.1, THE | | | DECIMALS OF A NUMBER ARE TO BE ROUNDED UP TO THE NEXT | | | HIGHER WHOLE NUMBER. NEW COMMENTS:THE OCCUPANT LOAD OF | | | 3.2 FOR THE SECOND FLOOR OFFICE #202 WILL BE 4 | | | OCCUPANTS, NOT 3. ON THE FIRST FLOOR THE 3.1 OCCUPANT | | | LOAD OF ROOM #102 WILL BE 4 OCCUPANTS AND THE 3.27 | | | OCCUPANTS OF ROOM #1 WILL ALSO BE 4 OCCUPANTS. | | | B) COMPLIES. | | | C) THE EXTERIOR EXIT STAIR IS REQUIRED BY FBC 1027.5 TO | | | HAVE A MINIMUM FIRE SEPARATION DISTANCE OF 10 FEET | | | MEASURED AT RIGHT ANGLES FROM THE EXTERIOR EDGE OF THE | | | STAIRWAY. THIS STAIRWAY DOES NOT HAVE 10 FEET TO THE | | | PROPERTY LINE OR TO THE BUILDING ON THE ADJACENT LOT. | | | NEW COMMENTS: THE BUILDING OFFICIAL HAS DETERMINED THAT | | | THE EXTERIOR EXIT STAIR WILL BE ALLOWED TO REMAIN AS | | | EXISTING, AS LONG AS, THE WALL OF THE ADJACENT BUILDING | | | IS CMU AND THE 4 X 4 WINDOW IN THE WALL IS NOT WITHIN | | | 10 FEET OF THE EXIT STAIRS. | | | | | | 3) COMPLIED. | | | | | | 4) COMPLIED. | | | | | | 5) ADDRESSED. | | | | | | 6) COMPLIED. | | | | | | 7) PARTIALLY COMPLIED. SPECIFY THE ITEMS AND QUANTITY | | | OF THEM THAT WILL BE STORED ON THE SECOND FLOOR IN ROOM | | | #204. NEW COMMENT: THE RESPONSE LETTER STATES THAT RUM | | | WILL BE STORED WITHIN THE BUILDING ON LEVEL TWO AND/OR | | | AS NEEDED ON LEVEL ONE. SINCE THERE WERE NO MSDS ( | | | MATERIAL SAFETY DATA SHEETS) SUBMITTED FOR THE RUM, I | | | WAS ABLE TO OBTAIN SOME INFORMATION ON RUM FROM THE | | | INTERNET. THE FLASH POINT FOR 80 % ETHANOL IS 20.0 | | | DEGREES CELCIUS (68 DEGREES F) AND THE BOILING POINT IS | | | 78.5 DEGREES CELCIUS (173.3 DEGREES F). THIS MAKES RUM | | | A CLASS IB FLAMABLE LIQUID. BASED ON FBC TABLE 307.1(1) | | | A MAXIMUM OF 120 GALLONS OF RUM CAN BE STORED PER | | | CONTROL AREA ON SITE WITHOUT BEING CONSIDERED AN H-3 | | | OCCUPANCY. FOOTNOTE B FOR THIS TABLE STATES THAT THE | | | AGGREGRATE QUANITY IN USE AND STORAGE SHALL NOT EXCEED | | | THE QUANITY LISTED FOR STORAGE. FOOTNOTE C ALLOWS THE | | | QUANTITY OF ALCOHOLIC BEVERAGES IN RETAIL AND WHOLESALE | | | SALE OCCUPANCIES TO NOT BE LIMITED, PROVIDED THE | | | LIQUIDS ARE PACKAGED IN INDIVIDUAL CONTAINERS NOT | | | EXCEEDING 1.3 GALLONS. THE BUILDING OFFICIAL WILL ALLOW | | | THE UNLIMITED STORAGE OF THE RUM IN INDIVIDUAL | | | CONTAINERS NOT EXCEEDING 1.3 GALLONS. WHEN THE | | | MATERIALS IN THE RUM PRODUCTION PROCESS REACH THE POINT | | | IT BECOMES A FLAMABLE LIQUID THEN NO MORE THAN 120 | | | GALLONS PER CONTROL AREA IS ALLOWED WITHOUT BEING | | | CONSIDERED A HAZARDOUS OCCUPANCY (H-3). FBC 307.1 THE | | | RUM DISTILLERY PROCESS OUTLINE THAT WAS SUBMITTED DOES | | | NOT STATE THE AMOUNT OF RUM ( CLASS IB FLAMABLE LIQUID) | | | THAT WILL BE IN THE PROCESS. THE PLANS SHOW A 1000 | | | GALLON AND A 600 GALLON SPIRIT SAFE. SO IT WOULD APPEAR | | | THAT THERE WILL BE AT LEAST 1600 GALLONS OF RUM IN THE | | | SPIRT SAFES. THIS EXCEEDS THE 120 GALLONS ALLOWED BY | | | FBC TABLE 307.1(1) AND WILL REQUIRE THIS AREA TO BE H-3 | | | RATHER THAN F-1. PLEASE ADVISE AS TO HOW THIS WILL BE | | | ADDRESSED. | | | | | | 8) ADDRESSED. | | | | | | 9) COMPLIED. | | | | | | 10) ADDRESSED. | | | | | | 11) ADDRESSED. | | | | | | 12) ADDRESSED. | | | | | | 13) ADDRESSED. | | | | | | 14) ADDRESSED. | | | | | | 15) 2017 FBC- ACCESSIBILITY - ADA | | | 201.1 SCOPE. | | | THIS CODE ESTABLISHES STANDARDS FOR ACCESSIBILITY TO | | | PLACES OF PUBLIC ACCOMMODATION AND COMMERCIAL | | | FACILITIES BY INDIVIDUALS WITH DISABILITIES. THIS CODE | | | SHALL ALSO APPLY: TO STATE AND LOCAL GOVERNMENT | | | FACILITIES PURSUANT TO SECTION 553.503, F.S.; TO | | | PRIVATE CLUBS PURSUANT TO SECTION 553.505, F.S.; AND TO | | | RESIDENTIAL BUILDINGS PURSUANT TO SECTION 553.504(2), | | | F.S., AND THE ADA STANDARDS FOR ACCESSIBLE DESIGN. ALL | | | NEW OR ALTERED PUBLIC BUILDINGS AND FACILITIES, PRIVATE | | | BUILDINGS AND FACILITIES, PLACES OF PUBLIC | | | ACCOMMODATION AND COMMERCIAL FACILITIES SUBJECT TO THIS | | | CODE SHALL COMPLY WITH THIS CODE. | | | THIS CODE APPLIES TO: ALL AREAS OF NEWLY DESIGNED AND | | | NEWLY CONSTRUCTED BUILDINGS AND FACILITIES AS | | | DETERMINED BY THE ADA STANDARDS FOR ACCESSIBLE DESIGN; | | | PORTIONS OF ALTERED BUILDINGS AND FACILITIES AS | | | DETERMINED BY THE ADA STANDARDS FOR ACCESSIBLE DESIGN; | | | A BUILDING OR FACILITY THAT IS BEING CONVERTED FROM | | | RESIDENTIAL TO NONRESIDENTIAL OR MIXED USE AS DEFINED | | | BY THE FLORIDA BUILDING CODE WHERE SUCH BUILDING OR | | | FACILITY MUST, AT A MINIMUM, COMPLY WITH S. 553.508, | | | F.S., AND THE REQUIREMENTS FOR ALTERATIONS AS | | | DETERMINED BY THE ADA STANDARDS FOR ACCESSIBLE DESIGN; | | | BUILDINGS AND FACILITIES WHERE THE ORIGINAL | | | CONSTRUCTION OR ANY FORMER ALTERATION OR RENOVATION WAS | | | CARRIED OUT IN VIOLATION OF APPLICABLE PERMITTING LAW. | | | | | | 15-1) CLARIFY. THE LETTER FROM THE OWNER MENTIONS | | | CUSTOMERS, WHICH WOULD BE THE PUBLIC. (IF ACCESS TO THE | | | PRIVATE RECEPTION TASTING AREA IS ALLOWED FOR PERSONS | | | OTHER THAN THE EMPLOYEES, THEN THE ADA REQUIREMENTS | | | APPLY. THE FBC ACCESSIBILTY ALSO APPLIES TO PRIVATE | | | BUILDINGS, CLUBS, ETC. IT APPEARS THAT YOUR DESIGN DOES | | | COMPLY WITH THE EXCEPTION OF VERTICAL ACCESSIBILTY.) | | | THE PLANS SHOW A RECEPTION/TASTING AREA THAT APPARENTLY | | | WILL BE OPEN TO THE PUBLIC. SPECIFY WHICH AREAS WILL BE | | | OPEN TO THE PUBLIC FOR TOURS, ETC. FBC 107.2.1 | | | | | | 15-2) NOT COMPLIANT. (THE RESPONSE TO THIS COMMENT | | | STATES THAT THE SECOND FLOOR IS PRIMARILY STORAGE WITH | | | ONE OFFICE WHICH HAS AN OCCUPANCY OF 3 PERSONS. THE | | | PLANS STILL SHOW TWO OFFICES AND AN OCCUPANCY OF 4 | | | PERSONS IN EACH FOR A TOTAL OF 8. THE CALCULATED | | | OCCUPANT LOAD FOR EACH SPACE IS REQUIRED TO BE ROUNDED | | | UP THE NEXT HIGHER WHOLE NUMBER. THE MECHANICAL ROOM | | | 206 SHOULD NOT HAVE AN OCCUPANT LOAD. THE OCCUPANT LOAD | | | FOR THE STORAGE AREA (3 PERSONS) DOES NOT COUNT TOWARD | | | ACCESSIBILITY. 201.1.1 VERTICAL ACCESSIBILITY. SECTIONS | | | 553.501-553.513, F.S., AND THE ADA STANDARDS FOR | | | ACCESSIBLE DESIGN DO NOT RELIEVE THE OWNER OF ANY | | | BUILDING, STRUCTURE OR FACILITY GOVERNED BY THOSE | | | SECTIONS FROM THE DUTY TO PROVIDE VERTICAL | | | ACCESSIBILITY TO ALL LEVELS ABOVE AND BELOW THE | | | OCCUPIABLE GRADE LEVEL REGARDLESS OF WHETHER THE | | | STANDARDS REQUIRE AN ELEVATOR TO BE INSTALLED IN SUCH | | | BUILDING, STRUCTURE OR FACILITY, EXCEPT FOR: | | | (1)ELEVATOR PITS, ELEVATOR PENTHOUSES, MECHANICAL | | | ROOMS, PIPING OR EQUIPMENT CATWALKS AND AUTOMOBILE | | | LUBRICATION AND MAINTENANCE PITS AND PLATFORMS. | | | (2)UNOCCUPIABLE SPACES, SUCH AS ROOMS, ENCLOSED SPACES | | | AND STORAGE SPACES THAT ARE NOT DESIGNED FOR HUMAN | | | OCCUPANCY, FOR PUBLIC ACCOMMODATIONS OR FOR WORK AREAS. | | | (3)OCCUPIABLE SPACES AND ROOMS THAT ARE NOT OPEN TO THE | | | PUBLIC AND THAT HOUSE NO MORE THAN FIVE PERSONS, | | | INCLUDING, BUT NOT LIMITED TO EQUIPMENT CONTROL ROOMS | | | AND PROJECTION BOOTHS. | | | (4)THEATERS, CONCERT HALLS, AND STADIUMS, OR OTHER | | | LARGE ASSEMBLY AREAS THAT HAVE STADIUM-STYLE SEATING OR | | | TIERED SEATING IF SECTIONS 221 AND 802 ARE MET. | | | (5)ALL PLAY AND RECREATION AREAS IF THE REQUIREMENTS OF | | | CHAPTER 10 ARE MET. | | | (6)ALL EMPLOYEE AREAS AS EXEMPTED BY 203.9. | | | (7)FACILITIES, SITES AND SPACES EXEMPTED BY SECTION | | | 203. | | | BUILDINGS, STRUCTURES AND FACILITIES MUST, AT A | | | MINIMUM, COMPLY WITH THE REQUIREMENTS OF THE ADA | | | STANDARDS FOR ACCESSIBLE DESIGN. | | | ADVISORY 201.1 SCOPE. THESE REQUIREMENTS ARE TO BE | | | APPLIED TO ALL AREAS OF A FACILITY UNLESS EXEMPTED, OR | | | WHERE SCOPING LIMITS THE NUMBER OF MULTIPLE ELEMENTS | | | REQUIRED TO BE ACCESSIBLE. FOR EXAMPLE, NOT ALL MEDICAL | | | CARE PATIENT ROOMS ARE REQUIRED TO BE ACCESSIBLE; THOSE | | | THAT ARE NOT REQUIRED TO BE ACCESSIBLE ARE NOT REQUIRED | | | TO COMPLY WITH THESE REQUIREMENTS. HOWEVER, COMMON USE | | | AND PUBLIC USE SPACES SUCH AS RECOVERY ROOMS, | | | EXAMINATION ROOMS, AND CAFETERIAS ARE NOT EXEMPT FROM | | | THESE REQUIREMENTS AND MUST BE ACCESSIBLE. | | | FLORIDA VERTICAL ACCESSIBILITY REQUIRES ALL LEVELS IN | | | ALL NEW BUILDINGS, STRUCTURES AND FACILITIES AND ALL | | | ALTERED AREAS OF EXISTING BUILDINGS, STRUCTURES AND | | | FACILITIES TO BE ACCESSIBLE TO PERSONS WITH | | | DISABILITIES. ALL NEW AND ALTERED AREAS MUST COMPLY | | | WITH THE ADA STANDARDS FOR ACCESSIBLE DESIGN INCLUDING | | | REQUIREMENTS FOR ACCESSIBLE ROUTES. WHERE THE ADA | | | STANDARDS DO NOT REQUIRE AN ACCESSIBLE ROUTE TO EACH | | | AND EVERY LEVEL, THE FLORIDA REQUIREMENT MAY BE WAIVED | | | DOWN TO THE REQUIREMENT OF THE ADA STANDARDS. | | | | | | 15-3) COMPLIED. | | | | | | 15-4) PARTIAL COMPLIANCE. (BATHROOM MUST BE ON AN | | | ACCESSIBLE ROUTE). NEW COMMENT: IF THE SECOND FLOOR IS | | | REQUIRED TO HAVE VERTICAL ACCESSIBILITY, THEN THE | | | BATHROOM ON THE SECOND LEVEL WILL HAVE TO COMPLY. | | | WHERE TOILET FACILITIES AND BATHING FACILITIES ARE | | | PROVIDED, THEY SHALL COMPLY WITH 213. WHERE TOILET | | | FACILITIES AND BATHING FACILITIES ARE PROVIDED IN | | | FACILITIES PERMITTED BY 206.2.3 EXCEPTIONS 1 AND 2 NOT | | | TO CONNECT STORIES BY AN ACCESSIBLE ROUTE, TOILET | | | FACILITIES AND BATHING FACILITIES SHALL BE PROVIDED ON | | | A STORY CONNECTED BY AN ACCESSIBLE ROUTE TO AN | | | ACCESSIBLE ENTRANCE. | | | 213.2 TOILET ROOMS AND BATHING ROOMS. | | | WHERE TOILET ROOMS ARE PROVIDED, EACH TOILET ROOM SHALL | | | COMPLY WITH 603. WHERE BATHING ROOMS ARE PROVIDED, EACH | | | BATHING ROOM SHALL COMPLY WITH 603. | | | | | | 16) PLEASE CLARIFY THE INTENT OF THE GENERAL | | | CONTRACTOR'S PRICING THAT WAS SUBMITTED. IS THE | | | $90,250.00 MEANT TO BE ADDED TO THE $320,000.00 PERMIT | | | VALUE? THE $320,000.00 PERMIT VALUE APPEARS TO BE LOW | | | FOR THE SCOPE OF THE PROPOSED PROJECT. PLEASE PROVIDE | | | CONTRACTS, INVOICES, ESTIMATES ETC. THAT SHOW THE TOTAL | | | COST OF THE PROJECT INCLUDING, LABOR, MATERIALS, | | | EQUIPMENT, APPLIANCES, FIXTURES, DESIGN FEES, SITE | | | WORK, OVERHEAD AND PROFIT- SECTION 109.3 WPB. | | | 109.3* BUILDING PERMIT VALUATION. | | | IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE | | | CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, | | | ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS | | | APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE | | | PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, | | | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL | | | REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND | | | SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE | | | STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR | | | FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR | | | BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING | | | COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | | (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS | | | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE | | | CONGRESS. | | | | | | THIS MAIN BUILDING PERMIT WILL INCLUDE THE FEES FOR THE | | | MECHANICAL, ELECTRICAL, PLUMBING & ROOFING PERMITS. | | | WHEN THE GENERAL CONTRACTOR COMES IN FOR A BUILDING | | | PERMIT WITH THE SIGNED PERMIT APPLICATION FORM BY THE | | | QUALIFIER AND OWNER AND BRINGS IN THE LISTED | | | SUB-PERMITS M-E-P & ROOFING PERMITS SIGNED BY THE | | | QUALIFIER OF EACH COMPANY, THEIR INSURANCES AND | | | LICENSURE UP TO DATE, THE M-E-P AND ROOFING PERMITS ARE | | | FREE OF CHARGE. IF THE M-E-P & ROOFING PERMITS COME IN | | | LATER THERE WILL BE AN $80.00 ADMINISTRATIVE FEE FOR | | | EACH PERMIT. | | | | | | ALL OTHER PERMITS FIRE SPRINKLER, FIRE ALARM, RACK | | | STORAGE, EXHAUST HOODS, ANSUL SYSTEMS OR ALTERNATIVE | | | AUTOMATIC FIRE-EXTINGUISHING SYSTEMS, WALK IN COOLERS & | | | FREEZERS, ALL LOW VOLTAGE PERMITS, GENERATORS & FUEL | | | TANKS, GAS PERMIT, POOL, JACUZZI AND ASSOCIATED | | | SUB-PERMITS, AWNING, SCREEN ENCLOSURES, CANOPY, FENCE, | | | LANDSCAPE, IRRIGATION, AUGER CAST PILE AND OR | | | FOUNDATION OR STRUCTURE ONLY PERMIT WILL BE SEPARATE | | | REVIEWS AND ASSOCIATED FEES WITH EACH PERMIT. | | | PLEASE PROVIDE AN ITEMIZED LIST AND SUBTRACT THESE LINE | | | ITEMS AND THEIR VALUE FROM THE OVERALL BUILDING VALUE | | | STATED ON THE PERMIT APPLICATION FOR THIS PROJECT. THE | | | REMAINING BALANCE WILL BE AFFECTIVELY THE VALUE OF THE | | | BUILDING YOU WILL BE PAYING FOR THIS PERMIT. THE | | | BUILDING DEPARTMENT DOES NOT WANT TO COLLECT TWICE FOR | | | THE VALUE OF THESE SUB-PERMITS NOT COVERED UNDER THE | | | PRIME OR MASTER PERMIT. | | | | | | 17) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A | | | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE | | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-09-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-09-27 |
Time |
19:34 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-09-24 |
Time |
08:24 |
Sent To |
|
|
| Notes |
| 2018-09-27 09:14:43 | 2ND REVIEW FBC-2017 BUILDING | | | PERMIT #18070030 | | | 415 SOUTHERN BLVD. | | | TYPE OF CONSTRUCTION: II B | | | OCCUPANCY TYPE: F-1 | | | SPRINKLERED BLDG: NO | | | LEVEL OF ALTERATION: LEVEL III ALTERATION, CHANGE OF | | | OCCUPANCY | | | | | | CODES IN EFFECT: | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) COMPLIED. | | | | | | 2) COMPLIED. SEE NEW COMMENTS REGARDING LIFE SAFETY | | | PLANS. | | | A) WHEN DETERMINING OCCUPANT LOADS PER FBC 1004.1, THE | | | DECIMALS OF A NUMBER ARE TO BE ROUNDED UP TO THE NEXT | | | HIGHER WHOLE NUMBER. | | | B) SHOW THAT THE TWO EXIT ACCESS STAIRWAYS FROM THE | | | SECOND FLOOR COMPLY WITH FBC1007.1 FOR THE REQUIRED | | | SEPARATION DISTANCE OF ONE-HALF THE LENGTH OF THE | | | MAXIMUM OVERALL DIAGONAL DIMENSION OF THE BUILDING OR | | | AREA TO BE SERVED MEASURED IN A STRAIGHT LINE BETWEEN | | | THEM. | | | C) THE EXTERIOR EXIT STAIR IS REQUIRED BY FBC 1027.5 TO | | | HAVE A MINIMUM FIRE SEPARATION DISTANCE OF 10 FEET | | | MEASURED AT RIGHT ANGLES FROM THE EXTERIOR EDGE OF THE | | | STAIRWAY. THIS STAIRWAY DOES NOT HAVE 10 FEET TO THE | | | PROPERTY LINE OR TO THE BUILDING ON THE ADJACENT LOT. | | | | | | 3) NOT COMPLIANT. (DESIGNER NEEDS TO REFERENCE 2017 FBC | | | EXISTING BUILDING AND CHANGE OF OCCUPANCY ON THE | | | PLANS.) IN ORDER TO PROVIDE A COMPLETE REVIEW, THE | | | ARCHITECT SHALL INDICATE THE CLASSIFICATION OF WORK AS | | | OUTLINED IN CHAPTER 5 FBC EXISTING BUILDING. THIS | | | APPEARS TO BE A CHANGE OF OCCUPANCY AS DEFINED IN | | | SECTION 202 FBC EX. PLEASE SEE SECTION 506 AND CHAPTER | | | 10 FOR ALL REQUIREMENTS. | | | | | | 4) NOT COMPLIANT. (DESIGNER NEEDS TO SPECIFY ON THE | | | PLANS THAT THIS BUILDING IS A NONSEPARATED MIXED USE | | | OCCUPANCY, F-1, B AND S-1.) SEE FBC 508.3 THE BUILDING | | | IS FUNCTIONING AS A MULTI-USE OCCUPANCY. INDICATE IF | | | THE BUILDING IS DESIGNED FOR MIXED USE (NON-SEPARATED) | | | OR SEPARATED USE PER SECTION 6.1.14.3 OF NFPA 101 | | | FLORIDA EDITION 2015. FOR NON-SEPARATED MIXED USE | | | OCCUPANCIES, THE MOST STRINGENT FIRE AND LIFE SAFETY | | | REQUIREMENTS OF EACH OCCUPANCY SHALL APPLY TO THE | | | BUILDING. | | | | | | 5) ADDRESSED. | | | | | | 6) COMPLIED. | | | | | | 7) SEE FIRE COMMENTS. NEW COMMENT: SPECIFY THE ITEMS | | | AND QUANTITY OF THEM THAT WILL BE STORED ON THE SECOND | | | FLOOR IN ROOM #204. SPECIFY THE REQUIRED UNIFORMLY | | | DISTRIBUTED LIVE LOAD FOR THIS STORAGE AREA AND THE | | | EXISTING FLOOR LIVE LOAD FOR THIS AREA. FBC 1607.1 | | | | | | 8) ADDRESSED. | | | | | | 9) PROVIDE WIND LOAD ENGINEERING AND INSTALLATION | | | DETAILS FOR THE CHILLER, BOILER, PUMPS, AND ALL OTHER | | | ASSOCIATED EXTERIOR EQUIPMENT AND SUPPORTS. 2017 FBC-B | | | 1603.1.4 WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | | STRUCTURE: | | | | | | 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | | MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED, | | | VASD, AS DETERMINED IN ACCORDANCE WITH SECTION | | | 1609.3.1. | | | | | | 2. RISK CATEGORY. | | | | | | 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | | THAN ONE WIND EXPOSURE IS UTILIZED. TABLE 1609.7.2. | | | HEIGHT AND EXPOSURE. | | | | | | 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | | | | | 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | | COMPONENTS AND CLADDING MATERIALS NOT SPECIFICALLY | | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL | | | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF. | | | | | | TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT & | | | EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE | | | BUILDING. | | | | | | 1609.3.1 WIND SPEED CONVERSION VULT TO VASD. | | | | | | 10) ADDRESSED. | | | | | | 11) ADDRESSED. | | | | | | 12) ADDRESSED. | | | | | | 13) ADDRESSED. | | | | | | 14) ADDRESSED. | | | | | | 15) 2017 FBC- ACCESSIBILITY - ADA | | | 201.1 SCOPE. | | | THIS CODE ESTABLISHES STANDARDS FOR ACCESSIBILITY TO | | | PLACES OF PUBLIC ACCOMMODATION AND COMMERCIAL | | | FACILITIES BY INDIVIDUALS WITH DISABILITIES. THIS CODE | | | SHALL ALSO APPLY: TO STATE AND LOCAL GOVERNMENT | | | FACILITIES PURSUANT TO SECTION 553.503, F.S.; TO | | | PRIVATE CLUBS PURSUANT TO SECTION 553.505, F.S.; AND TO | | | RESIDENTIAL BUILDINGS PURSUANT TO SECTION 553.504(2), | | | F.S., AND THE ADA STANDARDS FOR ACCESSIBLE DESIGN. ALL | | | NEW OR ALTERED PUBLIC BUILDINGS AND FACILITIES, PRIVATE | | | BUILDINGS AND FACILITIES, PLACES OF PUBLIC | | | ACCOMMODATION AND COMMERCIAL FACILITIES SUBJECT TO THIS | | | CODE SHALL COMPLY WITH THIS CODE. | | | THIS CODE APPLIES TO: ALL AREAS OF NEWLY DESIGNED AND | | | NEWLY CONSTRUCTED BUILDINGS AND FACILITIES AS | | | DETERMINED BY THE ADA STANDARDS FOR ACCESSIBLE DESIGN; | | | PORTIONS OF ALTERED BUILDINGS AND FACILITIES AS | | | DETERMINED BY THE ADA STANDARDS FOR ACCESSIBLE DESIGN; | | | A BUILDING OR FACILITY THAT IS BEING CONVERTED FROM | | | RESIDENTIAL TO NONRESIDENTIAL OR MIXED USE AS DEFINED | | | BY THE FLORIDA BUILDING CODE WHERE SUCH BUILDING OR | | | FACILITY MUST, AT A MINIMUM, COMPLY WITH S. 553.508, | | | F.S., AND THE REQUIREMENTS FOR ALTERATIONS AS | | | DETERMINED BY THE ADA STANDARDS FOR ACCESSIBLE DESIGN; | | | BUILDINGS AND FACILITIES WHERE THE ORIGINAL | | | CONSTRUCTION OR ANY FORMER ALTERATION OR RENOVATION WAS | | | CARRIED OUT IN VIOLATION OF APPLICABLE PERMITTING LAW. | | | | | | 15-1) CLARIFY. (IF ACCESS TO THE PRIVATE RECEPTION | | | TASTING AREA IS ALLOWED FOR PERSONS OTHER THAN THE | | | EMPLOYEES, THEN THE ADA REQUIREMENTS APPLY. THE FBC | | | ACCESSIBILTY ALSO APPLIES TO PRIVATE BUILDINGS, CLUBS, | | | ETC. IT APPEARS THAT YOUR DESIGN DOES COMPLY WITH THE | | | EXCEPTION OF VERTICAL ACCESSIBILTY.) THE PLANS SHOW A | | | RECEPTION/TASTING AREA THAT APPARENTLY WILL BE OPEN TO | | | THE PUBLIC. SPECIFY WHICH AREAS WILL BE OPEN TO THE | | | PUBLIC FOR TOURS, ETC. FBC 107.2.1 | | | | | | 15-2) NOT COMPLIANT. ( THE RESPONSE TO THIS COMMENT | | | STATES THAT THE SECOND FLOOR IS PRIMARILY STORAGE WITH | | | ONE OFFICE WHICH HAS AN OCCUPANCY OF 3 PERSONS. THE | | | PLANS SHOW TWO OFFICES AND AN OCCUPANCY OF 4 PERSONS IN | | | EACH FOR A TOTAL OF 8. THE CALCULATED OCCUPANT LOAD FOR | | | EACH SPACE IS REQUIRED TO BE ROUNDED UP THE NEXT HIGHER | | | WHOLE NUMBER. THE MECHANICAL ROOM 206 SHOULD NOT HAVE | | | AN OCCUPANT LOAD.) THE OCCUPANT LOAD FOR THE STORAGE | | | AREA (3 PERSONS) DOES NOT COUNT TOWARD ACCESSIBILITY. ) | | | 201.1.1 VERTICAL ACCESSIBILITY. SECTIONS | | | 553.501-553.513, F.S., AND THE ADA STANDARDS FOR | | | ACCESSIBLE DESIGN DO NOT RELIEVE THE OWNER OF ANY | | | BUILDING, STRUCTURE OR FACILITY GOVERNED BY THOSE | | | SECTIONS FROM THE DUTY TO PROVIDE VERTICAL | | | ACCESSIBILITY TO ALL LEVELS ABOVE AND BELOW THE | | | OCCUPIABLE GRADE LEVEL REGARDLESS OF WHETHER THE | | | STANDARDS REQUIRE AN ELEVATOR TO BE INSTALLED IN SUCH | | | BUILDING, STRUCTURE OR FACILITY, EXCEPT FOR: | | | (1)ELEVATOR PITS, ELEVATOR PENTHOUSES, MECHANICAL | | | ROOMS, PIPING OR EQUIPMENT CATWALKS AND AUTOMOBILE | | | LUBRICATION AND MAINTENANCE PITS AND PLATFORMS. | | | (2)UNOCCUPIABLE SPACES, SUCH AS ROOMS, ENCLOSED SPACES | | | AND STORAGE SPACES THAT ARE NOT DESIGNED FOR HUMAN | | | OCCUPANCY, FOR PUBLIC ACCOMMODATIONS OR FOR WORK AREAS. | | | (3)OCCUPIABLE SPACES AND ROOMS THAT ARE NOT OPEN TO THE | | | PUBLIC AND THAT HOUSE NO MORE THAN FIVE PERSONS, | | | INCLUDING, BUT NOT LIMITED TO EQUIPMENT CONTROL ROOMS | | | AND PROJECTION BOOTHS. | | | (4)THEATERS, CONCERT HALLS, AND STADIUMS, OR OTHER | | | LARGE ASSEMBLY AREAS THAT HAVE STADIUM-STYLE SEATING OR | | | TIERED SEATING IF SECTIONS 221 AND 802 ARE MET. | | | (5)ALL PLAY AND RECREATION AREAS IF THE REQUIREMENTS OF | | | CHAPTER 10 ARE MET. | | | (6)ALL EMPLOYEE AREAS AS EXEMPTED BY 203.9. | | | (7)FACILITIES, SITES AND SPACES EXEMPTED BY SECTION | | | 203. | | | BUILDINGS, STRUCTURES AND FACILITIES MUST, AT A | | | MINIMUM, COMPLY WITH THE REQUIREMENTS OF THE ADA | | | STANDARDS FOR ACCESSIBLE DESIGN. | | | ADVISORY 201.1 SCOPE. THESE REQUIREMENTS ARE TO BE | | | APPLIED TO ALL AREAS OF A FACILITY UNLESS EXEMPTED, OR | | | WHERE SCOPING LIMITS THE NUMBER OF MULTIPLE ELEMENTS | | | REQUIRED TO BE ACCESSIBLE. FOR EXAMPLE, NOT ALL MEDICAL | | | CARE PATIENT ROOMS ARE REQUIRED TO BE ACCESSIBLE; THOSE | | | THAT ARE NOT REQUIRED TO BE ACCESSIBLE ARE NOT REQUIRED | | | TO COMPLY WITH THESE REQUIREMENTS. HOWEVER, COMMON USE | | | AND PUBLIC USE SPACES SUCH AS RECOVERY ROOMS, | | | EXAMINATION ROOMS, AND CAFETERIAS ARE NOT EXEMPT FROM | | | THESE REQUIREMENTS AND MUST BE ACCESSIBLE. | | | FLORIDA VERTICAL ACCESSIBILITY REQUIRES ALL LEVELS IN | | | ALL NEW BUILDINGS, STRUCTURES AND FACILITIES AND ALL | | | ALTERED AREAS OF EXISTING BUILDINGS, STRUCTURES AND | | | FACILITIES TO BE ACCESSIBLE TO PERSONS WITH | | | DISABILITIES. ALL NEW AND ALTERED AREAS MUST COMPLY | | | WITH THE ADA STANDARDS FOR ACCESSIBLE DESIGN INCLUDING | | | REQUIREMENTS FOR ACCESSIBLE ROUTES. WHERE THE ADA | | | STANDARDS DO NOT REQUIRE AN ACCESSIBLE ROUTE TO EACH | | | AND EVERY LEVEL, THE FLORIDA REQUIREMENT MAY BE WAIVED | | | DOWN TO THE REQUIREMENT OF THE ADA STANDARDS. | | | | | | 15-3) NOT RESOLVED. PROVIDE AN ACCESSIBLE ROUTE TO AND | | | THROUGH THE PUBLIC AREAS. FBC-A 206.1 GENERAL. | | | ACCESSIBLE ROUTES SHALL BE PROVIDED IN ACCORDANCE WITH | | | 206 AND SHALL COMPLY WITH CHAPTER 4. | | | | | | 15-4) PARTICAL COMPLIANCE. ( BATHROOM MUST BE ON AN | | | ACCESSIBLE ROUTE.) PROVIDE AN ACCESSIBLE BATHROOM. | | | FBC-A 213 TOILET FACILITIES AND BATHING FACILITIES | | | 213.1 GENERAL. | | | WHERE TOILET FACILITIES AND BATHING FACILITIES ARE | | | PROVIDED, THEY SHALL COMPLY WITH 213. WHERE TOILET | | | FACILITIES AND BATHING FACILITIES ARE PROVIDED IN | | | FACILITIES PERMITTED BY 206.2.3 EXCEPTIONS 1 AND 2 NOT | | | TO CONNECT STORIES BY AN ACCESSIBLE ROUTE, TOILET | | | FACILITIES AND BATHING FACILITIES SHALL BE PROVIDED ON | | | A STORY CONNECTED BY AN ACCESSIBLE ROUTE TO AN | | | ACCESSIBLE ENTRANCE. | | | 213.2 TOILET ROOMS AND BATHING ROOMS. | | | WHERE TOILET ROOMS ARE PROVIDED, EACH TOILET ROOM SHALL | | | COMPLY WITH 603. WHERE BATHING ROOMS ARE PROVIDED, EACH | | | BATHING ROOM SHALL COMPLY WITH 603. | | | | | | 16) THE $320,000.00 PERMIT VALUE APPEARS TO BE LOW FOR | | | THE SCOPE OF THE PROPOSED PROJECT. PLEASE PROVIDE | | | CONTRACTS, INVOICES, ESTIMATES ETC. THAT SHOW THE TOTAL | | | COST OF THE PROJECT INCLUDING, LABOR, MATERIALS, | | | EQUIPMENT, APPLIANCES, FIXTURES, DESIGN FEES, SITE | | | WORK, OVERHEAD AND PROFIT- SECTION 109.3 WPB. | | | 109.3* BUILDING PERMIT VALUATION. | | | IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE | | | CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, | | | ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS | | | APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE | | | PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, | | | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL | | | REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND | | | SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE | | | STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR | | | FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR | | | BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING | | | COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | | (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS | | | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE | | | CONGRESS. | | | | | | THIS MAIN BUILDING PERMIT WILL INCLUDE THE FEES FOR THE | | | MECHANICAL, ELECTRICAL, PLUMBING & ROOFING PERMITS. | | | WHEN THE GENERAL CONTRACTOR COMES IN FOR A BUILDING | | | PERMIT WITH THE SIGNED PERMIT APPLICATION FORM BY THE | | | QUALIFIER AND OWNER AND BRINGS IN THE LISTED | | | SUB-PERMITS M-E-P & ROOFING PERMITS SIGNED BY THE | | | QUALIFIER OF EACH COMPANY, THEIR INSURANCES AND | | | LICENSURE UP TO DATE, THE M-E-P AND ROOFING PERMITS ARE | | | FREE OF CHARGE. IF THE M-E-P & ROOFING PERMITS COME IN | | | LATER THERE WILL BE AN $80.00 ADMINISTRATIVE FEE FOR | | | EACH PERMIT. | | | | | | ALL OTHER PERMITS FIRE SPRINKLER, FIRE ALARM, RACK | | | STORAGE, EXHAUST HOODS, ANSUL SYSTEMS OR ALTERNATIVE | | | AUTOMATIC FIRE-EXTINGUISHING SYSTEMS, WALK IN COOLERS & | | | FREEZERS, ALL LOW VOLTAGE PERMITS, GENERATORS & FUEL | | | TANKS, GAS PERMIT, POOL, JACUZZI AND ASSOCIATED | | | SUB-PERMITS, AWNING, SCREEN ENCLOSURES, CANOPY, FENCE, | | | LANDSCAPE, IRRIGATION, AUGER CAST PILE AND OR | | | FOUNDATION OR STRUCTURE ONLY PERMIT WILL BE SEPARATE | | | REVIEWS AND ASSOCIATED FEES WITH EACH PERMIT. | | | PLEASE PROVIDE AN ITEMIZED LIST AND SUBTRACT THESE LINE | | | ITEMS AND THEIR VALUE FROM THE OVERALL BUILDING VALUE | | | STATED ON THE PERMIT APPLICATION FOR THIS PROJECT. THE | | | REMAINING BALANCE WILL BE AFFECTIVELY THE VALUE OF THE | | | BUILDING YOU WILL BE PAYING FOR THIS PERMIT. THE | | | BUILDING DEPARTMENT DOES NOT WANT TO COLLECT TWICE FOR | | | THE VALUE OF THESE SUB-PERMITS NOT COVERED UNDER THE | | | PRIME OR MASTER PERMIT. | | | | | | 17) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A | | | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE | | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-08-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-08-02 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-08-01 |
Time |
13:12 |
Sent To |
|
|
| Notes |
| 2018-08-01 19:02:33 | 1ST REVIEW FBC-2017 BUILDING | | | PERMIT #18070030 | | | 415 SOUTHERN BLVD. | | | TYPE OF CONSTRUCTION: ? | | | OCCUPANCY TYPE: ? | | | SPRINKLERED BLDG: NO | | | LEVEL OF ALTERATION: LEVEL III ALTERATION, CHANGE OF | | | OCCUPANCY | | | | | | CODES IN EFFECT: | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) ASBESTOS: IN ACCORDANCE WITH SECTION 553.79 F. S. | | | THIS IS TO ADVISE YOU OF THE OWNERS OR OPERATORS? | | | RESPONSIBILITY TO COMPLY WITH THE STATE & FEDERAL | | | ASBESTOS REGULATIONS, INCLUDING SECTION 376.60 F. S. | | | AND CFR 61- NESHAP REQUIREMENTS. REQUIREMENTS INCLUDE- | | | ASBESTOS SURVEYS AND SUBMISSION OF WRITTEN NOTIFICATION | | | TO THE DEPARTMENT OF ENVIRONMENTAL PROTECTION PRIOR TO: | | | * DEMOLITION OF ALL REGULATED STRUCTURES; | | | * MOST RENOVATION ACTIVITIES IN REGULATED STRUCTURES | | | WHERE ASBESTOS IS DISTURBED OR REMOVED. | | | NON-COMPLIANCE MAY RESULT IN SEVERE MONETARY PENALTY. | | | | | | FOR FURTHER INFORMATION IN PALM BEACH COUNTY, CONTACT | | | THE DIVISION OF ENVIRONMENTAL HEALTH AND ENGINEERING | | | HRS/ PALM BEACH COUNTY PUBLIC HEALTH UNIT | | | (DIVISION OF ENGINEERING SCIENCE & ENGINEERING AIR | | | POLLUTION CONTROL SECTION) | | | | | | 901 EVERNIA STREET | | | WEST PALM BEACH, FL 33401 | | | (561) 355-3070 | | | | | | 2) A LIFE SAFETY PLAN (SHEET A250) IS IDENTIFIED ON THE | | | SHEET INDEX, HOWEVER IT WAS NOT PROVIDED WITH THIS | | | SUBMISSION. PLEASE PROVIDE A LIFE SAFETY PLAN SHOWING | | | TYPE OF CONSTRUCTION AND ALL OCCUPANCY TYPES, OCCUPANT | | | LOADS, FIRE RATED WALLS, EXIT SIGNS, EMERGENCY | | | LIGHTING, TRAVEL DISTANCES, COMMON PATH OF TRAVEL, FIRE | | | SPRINKLER CLASSIFICATION, LOCATION OF FIRE SEPARATIONS | | | AND HOURLY FIRE-RATINGS, FIRESTOPPING FOR PIPES, | | | CONDUITS, AND DUCTWORK, EGRESS PATHS AND TRAVEL | | | DISTANCES, ETC.- SECTION 107.2.1 WPB AMENDMENTS | | | | | | 3) IN ORDER TO PROVIDE A COMPLETE REVIEW, THE ARCHITECT | | | SHALL INDICATE THE CLASSIFICATION OF WORK AS OUTLINED | | | IN CHAPTER 5 FBC EXISTING BUILDING. THIS APPEARS TO BE | | | A CHANGE OF OCCUPANCY AS DEFINED IN SECTION 202 FBC EX. | | | PLEASE SEE SECTION 506 AND CHAPTER 10 FOR ALL | | | REQUIREMENTS. | | | | | | 4) THE BUILDING IS FUNCTIONING AS A MULTI-USE | | | OCCUPANCY. INDICATE IF THE BUILDING IS DESIGNED FOR | | | MIXED USE (NON-SEPARATED) OR SEPARATED USE PER SECTION | | | 6.1.14.3 OF NFPA 101 FLORIDA EDITION 2015. FOR | | | NON-SEPARATED MIXED USE OCCUPANCIES, THE MOST STRINGENT | | | FIRE AND LIFE SAFETY REQUIREMENTS OF EACH OCCUPANCY | | | SHALL APPLY TO THE BUILDING. | | | | | | 5) SUBMIT MANUFACTURER'S SPECIFICATIONS AND/OR CUT | | | SHEETS FOR ALL EQUIPMENT LISTED IN THE SCHEDULE | | | INCLUDING THE CHILLER, BOILER, STILLS ETC. THE SPECS | | | SHALL INDICATE THE LISTING AND LABELING, OR TESTING | | | STANDARD APPLIED TO EACH PIECE OF EQUIPMENT- SECTION | | | 107.2.1 WPB. | | | | | | 6) PLEASE PROVIDE AN OUTLINE DETAILING THE DISTILLING | | | AND/OR BREWING PROCESS THAT WILL OCCUR AT THIS | | | FACILITY. FBC 107.2.1 | | | | | | 7) PLEASE PROVIDE DETAILS REGARDING THE MANUFACTURE, | | | PROCESSING, GENERATION AND STORAGE OF HAZARDOUS | | | MATERIALS AT THIS SITE PER NFPA 101, CHAPTER 6 AND FBC | | | SECTION 307. | | | [F]307.1 HIGH-HAZARD GROUP H. | | | HIGH-HAZARD GROUP H OCCUPANCY INCLUDES, AMONG OTHERS, | | | THE USE OF A BUILDING OR STRUCTURE, OR A PORTION | | | THEREOF, THAT INVOLVES THE MANUFACTURING, PROCESSING, | | | GENERATION OR STORAGE OF MATERIALS THAT CONSTITUTE A | | | PHYSICAL OR HEALTH HAZARD IN QUANTITIES IN EXCESS OF | | | THOSE ALLOWED IN CONTROL AREAS COMPLYING WITH SECTION | | | 414, BASED ON THE MAXIMUM ALLOWABLE QUANTITY LIMITS FOR | | | CONTROL AREAS SET FORTH IN TABLES 307.1(1) AND | | | 307.1(2). HAZARDOUS OCCUPANCIES ARE CLASSIFIED IN | | | GROUPS H-1, H-2, H-3, H-4 AND H-5 AND SHALL BE IN | | | ACCORDANCE WITH THIS SECTION, THE REQUIREMENTS OF | | | SECTION 415 AND THE FLORIDA FIRE PREVENTION CODE. | | | HAZARDOUS MATERIALS STORED, OR USED ON TOP OF ROOFS OR | | | CANOPIES, SHALL BE CLASSIFIED AS OUTDOOR STORAGE OR USE | | | AND SHALL COMPLY WITH THE FLORIDA FIRE PREVENTION CODE. | | | SEE FBC B TABLE 307.1(1) | | | [F]307.1.2 HAZARDOUS MATERIALS. | | | HAZARDOUS MATERIALS IN ANY QUANTITY SHALL CONFORM TO | | | THE REQUIREMENTS OF THIS CODE, INCLUDING SECTION 414, | | | AND THE FLORIDA FIRE PREVENTION CODE. | | | | | | 8) SUBMIT TWO COPIES OF THE MATERIAL SAFETY DATA SHEETS | | | (MSDS) FOR THE HAZARDOUS MATERIALS (FLAMMABLE LIQUIDS, | | | ETC.) THAT WILL BE PRESENT AT THIS FACILITY. FBC B | | | 307.1.2 | | | | | | 9) PROVIDE WIND LOAD ENGINEERING AND INSTALLATION | | | DETAILS FOR THE CHILLER, BOILER, PUMPS, AND ALL OTHER | | | ASSOCIATED EXTERIOR EQUIPMENT AND SUPPORTS. 2017 FBC-B | | | 1603.1.4 WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | | STRUCTURE: | | | | | | 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | | MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED, | | | VASD, AS DETERMINED IN ACCORDANCE WITH SECTION | | | 1609.3.1. | | | | | | 2. RISK CATEGORY. | | | | | | 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | | THAN ONE WIND EXPOSURE IS UTILIZED. TABLE 1609.7.2. | | | HEIGHT AND EXPOSURE. | | | | | | 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | | | | | 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | | COMPONENTS AND CLADDING MATERIALS NOT SPECIFICALLY | | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL | | | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF. | | | | | | TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT & | | | EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE | | | BUILDING. | | | | | | 1609.3.1 WIND SPEED CONVERSION VULT TO VASD. | | | | | | 10) COMPONENTS & CLADDING | | | 2017 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | | OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, | | | RULE 9N-3 | | | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT | | | WILL REQUIRE PRODUCT APPROVALS: | | | (A) EXTERIOR DOORS ,MULLIONS & ROOF HATCHES. | | | (B) WINDOWS & MULLIONS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP | | | VENTILATORS | | | (E) SHUTTERS | | | (F) SKYLIGHTS | | | (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C | | | STANDS | | | | | | 11) W. P. B. 107.3.4.1 PRODUCT APPROVALS. THOSE | | | PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03 | | | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE | | | ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING | | | ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC. | | | | | | 12)W.P.B. 107.3.4.2 DEFERRED SUBMITTALS. FOR THE | | | PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS ARE | | | DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE NOT | | | SUBMITTED AT THE TIME OF THE APPLICATION AND THAT ARE | | | TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A | | | SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL | | | HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE | | | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | | SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION | | | DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | 13) CLARIFY IF THE EXISTING SLAB HAS BEEN EVALUATED FOR | | | THE INCREASED LOADS OF THE DISTILLERY TANKS, KETTLES, | | | STILLS ETC, AND PROVIDE ANCHORING DETAILS. FBC-B 1606 | | | AND 1607 | | | | | | 14) PLEASE PROVIDE A PLAN THAT SHOWS THE REQUIRED | | | WORKING CLEARANCES AROUND THE STILLS, KETTLES, AS | | | REQUIRED BY THE LISTING AGENCY OR THE MANUFACTURER, AND | | | CLARIFY IF THE EXISTING SLAB HAS BEEN EVALUATED FOR THE | | | INCREASED LOADS OF THE DISTILLERY EQUIPMENT- SECTION | | | 107.2.1 WPB. | | | | | | 15) 2017 FBC- ACCESSIBILITY - ADA | | | 201.1 SCOPE. | | | THIS CODE ESTABLISHES STANDARDS FOR ACCESSIBILITY TO | | | PLACES OF PUBLIC ACCOMMODATION AND COMMERCIAL | | | FACILITIES BY INDIVIDUALS WITH DISABILITIES. THIS CODE | | | SHALL ALSO APPLY: TO STATE AND LOCAL GOVERNMENT | | | FACILITIES PURSUANT TO SECTION 553.503, F.S.; TO | | | PRIVATE CLUBS PURSUANT TO SECTION 553.505, F.S.; AND TO | | | RESIDENTIAL BUILDINGS PURSUANT TO SECTION 553.504(2), | | | F.S., AND THE ADA STANDARDS FOR ACCESSIBLE DESIGN. ALL | | | NEW OR ALTERED PUBLIC BUILDINGS AND FACILITIES, PRIVATE | | | BUILDINGS AND FACILITIES, PLACES OF PUBLIC | | | ACCOMMODATION AND COMMERCIAL FACILITIES SUBJECT TO THIS | | | CODE SHALL COMPLY WITH THIS CODE. | | | THIS CODE APPLIES TO: ALL AREAS OF NEWLY DESIGNED AND | | | NEWLY CONSTRUCTED BUILDINGS AND FACILITIES AS | | | DETERMINED BY THE ADA STANDARDS FOR ACCESSIBLE DESIGN; | | | PORTIONS OF ALTERED BUILDINGS AND FACILITIES AS | | | DETERMINED BY THE ADA STANDARDS FOR ACCESSIBLE DESIGN; | | | A BUILDING OR FACILITY THAT IS BEING CONVERTED FROM | | | RESIDENTIAL TO NONRESIDENTIAL OR MIXED USE AS DEFINED | | | BY THE FLORIDA BUILDING CODE WHERE SUCH BUILDING OR | | | FACILITY MUST, AT A MINIMUM, COMPLY WITH S. 553.508, | | | F.S., AND THE REQUIREMENTS FOR ALTERATIONS AS | | | DETERMINED BY THE ADA STANDARDS FOR ACCESSIBLE DESIGN; | | | BUILDINGS AND FACILITIES WHERE THE ORIGINAL | | | CONSTRUCTION OR ANY FORMER ALTERATION OR RENOVATION WAS | | | CARRIED OUT IN VIOLATION OF APPLICABLE PERMITTING LAW. | | | | | | 15-1) THE PLANS SHOW A RECEPTION/TASTING AREA THAT | | | APPARENTLY WILL BE OPEN TO THE PUBLIC. SPECIFY WHICH | | | AREAS WILL BE OPEN TO THE PUBLIC FOR TOURS, ETC. FBC | | | 107.2.1 | | | | | | 15-2) 201.1.1 VERTICAL ACCESSIBILITY. SECTIONS | | | 553.501-553.513, F.S., AND THE ADA STANDARDS FOR | | | ACCESSIBLE DESIGN DO NOT RELIEVE THE OWNER OF ANY | | | BUILDING, STRUCTURE OR FACILITY GOVERNED BY THOSE | | | SECTIONS FROM THE DUTY TO PROVIDE VERTICAL | | | ACCESSIBILITY TO ALL LEVELS ABOVE AND BELOW THE | | | OCCUPIABLE GRADE LEVEL REGARDLESS OF WHETHER THE | | | STANDARDS REQUIRE AN ELEVATOR TO BE INSTALLED IN SUCH | | | BUILDING, STRUCTURE OR FACILITY, EXCEPT FOR: | | | (1)ELEVATOR PITS, ELEVATOR PENTHOUSES, MECHANICAL | | | ROOMS, PIPING OR EQUIPMENT CATWALKS AND AUTOMOBILE | | | LUBRICATION AND MAINTENANCE PITS AND PLATFORMS. | | | (2)UNOCCUPIABLE SPACES, SUCH AS ROOMS, ENCLOSED SPACES | | | AND STORAGE SPACES THAT ARE NOT DESIGNED FOR HUMAN | | | OCCUPANCY, FOR PUBLIC ACCOMMODATIONS OR FOR WORK AREAS. | | | (3)OCCUPIABLE SPACES AND ROOMS THAT ARE NOT OPEN TO THE | | | PUBLIC AND THAT HOUSE NO MORE THAN FIVE PERSONS, | | | INCLUDING, BUT NOT LIMITED TO EQUIPMENT CONTROL ROOMS | | | AND PROJECTION BOOTHS. | | | (4)THEATERS, CONCERT HALLS, AND STADIUMS, OR OTHER | | | LARGE ASSEMBLY AREAS THAT HAVE STADIUM-STYLE SEATING OR | | | TIERED SEATING IF SECTIONS 221 AND 802 ARE MET. | | | (5)ALL PLAY AND RECREATION AREAS IF THE REQUIREMENTS OF | | | CHAPTER 10 ARE MET. | | | (6)ALL EMPLOYEE AREAS AS EXEMPTED BY 203.9. | | | (7)FACILITIES, SITES AND SPACES EXEMPTED BY SECTION | | | 203. | | | BUILDINGS, STRUCTURES AND FACILITIES MUST, AT A | | | MINIMUM, COMPLY WITH THE REQUIREMENTS OF THE ADA | | | STANDARDS FOR ACCESSIBLE DESIGN. | | | ADVISORY 201.1 SCOPE. THESE REQUIREMENTS ARE TO BE | | | APPLIED TO ALL AREAS OF A FACILITY UNLESS EXEMPTED, OR | | | WHERE SCOPING LIMITS THE NUMBER OF MULTIPLE ELEMENTS | | | REQUIRED TO BE ACCESSIBLE. FOR EXAMPLE, NOT ALL MEDICAL | | | CARE PATIENT ROOMS ARE REQUIRED TO BE ACCESSIBLE; THOSE | | | THAT ARE NOT REQUIRED TO BE ACCESSIBLE ARE NOT REQUIRED | | | TO COMPLY WITH THESE REQUIREMENTS. HOWEVER, COMMON USE | | | AND PUBLIC USE SPACES SUCH AS RECOVERY ROOMS, | | | EXAMINATION ROOMS, AND CAFETERIAS ARE NOT EXEMPT FROM | | | THESE REQUIREMENTS AND MUST BE ACCESSIBLE. | | | FLORIDA VERTICAL ACCESSIBILITY REQUIRES ALL LEVELS IN | | | ALL NEW BUILDINGS, STRUCTURES AND FACILITIES AND ALL | | | ALTERED AREAS OF EXISTING BUILDINGS, STRUCTURES AND | | | FACILITIES TO BE ACCESSIBLE TO PERSONS WITH | | | DISABILITIES. ALL NEW AND ALTERED AREAS MUST COMPLY | | | WITH THE ADA STANDARDS FOR ACCESSIBLE DESIGN INCLUDING | | | REQUIREMENTS FOR ACCESSIBLE ROUTES. WHERE THE ADA | | | STANDARDS DO NOT REQUIRE AN ACCESSIBLE ROUTE TO EACH | | | AND EVERY LEVEL, THE FLORIDA REQUIREMENT MAY BE WAIVED | | | DOWN TO THE REQUIREMENT OF THE ADA STANDARDS. | | | | | | 15-3) PROVIDE AN ACCESSIBLE ROUTE TO AND THROUGH THE | | | PUBLIC AREAS. FBC-A 206.1 GENERAL. ACCESSIBLE ROUTES | | | SHALL BE PROVIDED IN ACCORDANCE WITH 206 AND SHALL | | | COMPLY WITH CHAPTER 4. | | | | | | 15-4) PROVIDE AN ACCESSIBLE BATHROOM. | | | FBC-A 213 TOILET FACILITIES AND BATHING FACILITIES | | | 213.1 GENERAL. | | | WHERE TOILET FACILITIES AND BATHING FACILITIES ARE | | | PROVIDED, THEY SHALL COMPLY WITH 213. WHERE TOILET | | | FACILITIES AND BATHING FACILITIES ARE PROVIDED IN | | | FACILITIES PERMITTED BY 206.2.3 EXCEPTIONS 1 AND 2 NOT | | | TO CONNECT STORIES BY AN ACCESSIBLE ROUTE, TOILET | | | FACILITIES AND BATHING FACILITIES SHALL BE PROVIDED ON | | | A STORY CONNECTED BY AN ACCESSIBLE ROUTE TO AN | | | ACCESSIBLE ENTRANCE. | | | 213.2 TOILET ROOMS AND BATHING ROOMS. | | | WHERE TOILET ROOMS ARE PROVIDED, EACH TOILET ROOM SHALL | | | COMPLY WITH 603. WHERE BATHING ROOMS ARE PROVIDED, EACH | | | BATHING ROOM SHALL COMPLY WITH 603. | | | | | | 16) THE $320,000.00 PERMIT VALUE APPEARS TO BE LOW FOR | | | THE SCOPE OF THE PROPOSED PROJECT. PLEASE PROVIDE | | | CONTRACTS, INVOICES, ESTIMATES ETC. THAT SHOW THE TOTAL | | | COST OF THE PROJECT INCLUDING, LABOR, MATERIALS, | | | EQUIPMENT, APPLIANCES, FIXTURES, DESIGN FEES, SITE | | | WORK, OVERHEAD AND PROFIT- SECTION 109.3 WPB. | | | 109.3* BUILDING PERMIT VALUATION. | | | IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE | | | CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, | | | ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS | | | APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE | | | PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, | | | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL | | | REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND | | | SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE | | | STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR | | | FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR | | | BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING | | | COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | | (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS | | | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE | | | CONGRESS. | | | | | | THIS MAIN BUILDING PERMIT WILL INCLUDE THE FEES FOR THE | | | MECHANICAL, ELECTRICAL, PLUMBING & ROOFING PERMITS. | | | WHEN THE GENERAL CONTRACTOR COMES IN FOR A BUILDING | | | PERMIT WITH THE SIGNED PERMIT APPLICATION FORM BY THE | | | QUALIFIER AND OWNER AND BRINGS IN THE LISTED | | | SUB-PERMITS M-E-P & ROOFING PERMITS SIGNED BY THE | | | QUALIFIER OF EACH COMPANY, THEIR INSURANCES AND | | | LICENSURE UP TO DATE, THE M-E-P AND ROOFING PERMITS ARE | | | FREE OF CHARGE. IF THE M-E-P & ROOFING PERMITS COME IN | | | LATER THERE WILL BE AN $80.00 ADMINISTRATIVE FEE FOR | | | EACH PERMIT. | | | | | | ALL OTHER PERMITS FIRE SPRINKLER, FIRE ALARM, RACK | | | STORAGE, EXHAUST HOODS, ANSUL SYSTEMS OR ALTERNATIVE | | | AUTOMATIC FIRE-EXTINGUISHING SYSTEMS, WALK IN COOLERS & | | | FREEZERS, ALL LOW VOLTAGE PERMITS, GENERATORS & FUEL | | | TANKS, GAS PERMIT, POOL, JACUZZI AND ASSOCIATED | | | SUB-PERMITS, AWNING, SCREEN ENCLOSURES, CANOPY, FENCE, | | | LANDSCAPE, IRRIGATION, AUGER CAST PILE AND OR | | | FOUNDATION OR STRUCTURE ONLY PERMIT WILL BE SEPARATE | | | REVIEWS AND ASSOCIATED FEES WITH EACH PERMIT. | | | PLEASE PROVIDE AN ITEMIZED LIST AND SUBTRACT THESE LINE | | | ITEMS AND THEIR VALUE FROM THE OVERALL BUILDING VALUE | | | STATED ON THE PERMIT APPLICATION FOR THIS PROJECT. THE | | | REMAINING BALANCE WILL BE AFFECTIVELY THE VALUE OF THE | | | BUILDING YOU WILL BE PAYING FOR THIS PERMIT. THE | | | BUILDING DEPARTMENT DOES NOT WANT TO COLLECT TWICE FOR | | | THE VALUE OF THESE SUB-PERMITS NOT COVERED UNDER THE | | | PRIME OR MASTER PERMIT. | | | | | | 17) A THOROUGH AND COMPLETE PLAN REVIEW CANNOT BE | | | COMPLETED AT THIS TIME DUE TO LACK OF INFORMATION | | | SUBMITTED ON THE PLANS. ADDITIONAL PLAN REVIEW COMMENTS | | | MAY BE GENERATED DURING PLAN RESUBMISSION. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2019-03-16 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-03-16 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-03-16 |
Time |
09:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2018-11-19 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-11-19 |
Time |
08:11 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-11-19 |
Time |
08:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2018-11-01 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-11-01 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-11-01 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2018-11-01 09:38:36 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. CORRECTED. | | | 2. CORRECTED. | | | 3. CORRECTED. | | | 4. CORRECTED. | | | 5. CORRECTED. | | | 6. CORRECTED. | | | 7. CORRECTED. | | | 8. CORRECTED. | | | 9. CORRECTED. | | | 10. CORRECTED. | | | 11. CORRECTED. | | | | | | NEW COMMENT: | | | | | | 12. NEW DESIGN PROVIDED SHOWS THE EXISTING 200 AMP | | | METER CAN FEEDING NEW MAIN 1 OF 2. THIS MAIN IS RATED | | | AT 225 AMPS, WHICH EXCEEDS THE CAPACITY OF THE METER | | | CAN. PROVIDE CORRECTION. NEC 110.3 | | | 13. PROVIDE DISONNECT WITHIN SIGHT OF TRANSFORMER | | | XFMR-1. NEC 450.14 | | | 14. REMOVE CLOUDS FROM PREVIOUSLY CORRECTED COMMENTS. | | | WPB FBC 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-09-18 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-09-18 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-09-18 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2018-09-18 15:57:32 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. CORRECTED. | | | 2. CORRECTED. | | | 3. CORRECTED. | | | 4. CORRECTED. | | | 5. CORRECTED. | | | 6. CORRECTED. | | | 7. CORRECTED. | | | 8. CORRECTED. | | | 9. PROVIDE ACCURATE LOAD CALCULATION FOR EACH PANEL AND | | | SERVICE. IT APPEARS THE LOAD FOR THE WATER HEATER IS | | | MISSING. NEC 220 (PANEL A AND B DO NOT HAVE TOTALS FOR | | | THE LOADS. PANEL SCHEDULE INCOMPLETE.) | | | 10. CORRECTED. | | | | | | NEW COMMENT: | | | | | | 11. RISER DIAGRAM SHOWS FEEDERS WITH A REDUCED NEUTRAL | | | TO EACH PANEL. HOWEVER, THE PANEL SCHEDULES CALL FOR | | | FULL SIZE NEUTRALS. CORRECT DISCREPANCY. IF REDUCED | | | NEUTRAL SIZE IS DESIRED, PROVIDE NEUTRAL DEMAND LOAD | | | CALCULATION. WPB FBC 107.2.1; NEC 220.61 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-07-08 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-07-08 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-07-08 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2018-07-08 12:46:07 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. THE INTERIOR LIGHTING POWER ALLOWANCE SCHEDULE ON | | | SHEET E101 SPECIFIES THE WRONG CODE FOR DESIGN. PROVIDE | | | CORRECTION. FBC PREFACE (ALSO SEE CURRENT CODES ABOVE) | | | 2. LIGHTING CONTROL IS NOT SHOWN IN DETAILS OR ON PLAN. | | | PROVIDE THE ADDITIONAL AUTOMATIC LIGHTING CONTROLS | | | STIPULATED IN THE FBC ENERGY CODE. FBC EC C405.2 | | | 3. SHEET E102, SERVICE KEY NOTE 2 STATES THAT A NEW 600 | | | AMP SERVICE IS PROPOSED, WHILE THE RISER DIAGRAM SHOWS | | | AN 800 AMP SERVICE. PROVIDE CLARIFICATION AND/OR | | | CORRECTION. WPB FBC 107.2.1 | | | 4. PROVIDE COMPLETE RISER DIAGRAM, SHOWING ALL DETAILS | | | OF SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. PLAN CURRENTLY | | | ONLY SHOWS THE NEW PROPOSED SERVICE, NOT THE EXISTING | | | THAT IS TO REMAIN. NEC 215.5, 230, 250.50, 250.94, | | | 408.30; WPB FBC 107.2.1 | | | 5. PER NEC 230.2, ONLY ONE SERVICE IS PERMITTED UNLESS | | | PERMITTED IN 230.2(A) THROUGH (D). EOR HAS NOT DETAILED | | | WHY THE ADDITIONAL SERVICE IS REQUESTED. PROVIDE | | | DETAILS OF WHY THE EXISTING SERVICE IS NOT ADEQUATE. | | | 6. MAINS MUST BE GROUPED PER NEC 230.72. PROVIDE | | | CORRECTION. NEC 230.72 | | | 7. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | PLAN CURRENTLY ONLY SHOWS CALCULATION FOR SERVICE | | | DISCONNECT. NEC 110.9, 110.10 | | | 8. PROVIDE AIC RATING OF EACH PANEL. NEC 110.3, 110.9; | | | WPB FBC 107.2.1 | | | 9. PROVIDE ACCURATE LOAD CALCULATION FOR EACH PANEL AND | | | SERVICE. IT APPEARS THE LOAD FOR THE WATER HEATER IS | | | MISSING. NEC 220 | | | 10. PROVIDE PANEL SCHEDULE FOR EXISTING PANELS | | | INDICATING ANY NEW OR ALTERED CIRCUITS, THE WIRE AND | | | BREAKER SIZE FOR THESE CIRCUITS, AND GFCI PROTECTION OR | | | LIGHTING CONTROL WHERE APPLICABLE TO COMPLY WITH CODE. | | | NEC 210.8, 210.19, 210.20, 215.2, 215.5, 408.4; FBC EC | | | C405 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2019-03-15 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2019-03-15 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2019-03-15 |
Time |
09:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2018-10-29 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-10-29 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-10-29 |
Time |
13:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2018-09-11 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-09-11 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-09-05 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2018-09-11 13:35:28 | PERMIT # 18070030 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | 2ND REVIEW: | | | | | | 1) SHEET A250: PER SECTION 8.7, ANY AREA HAVING A | | | DEGREE OF HAZARD GREATER THAN NORMAL TO THE GENERAL | | | OCCUPANCY OF THE BUILDING, SHALL BE SEPARATED FROM | | | NON-STORAGE AREAS WITH A 1-HOUR FIRE-RATED BARRIER OR | | | BE PROTECTED WITH AN AUTOMATIC SPRINKLER SYSTEM. DOORS | | | SHALL BE SELF CLOSING, POSITIVE LATCHING, AND | | | FIRE-RATED FOR AT LEAST 45-MINUTES. | | | HAZARD OF CONTENTS SEPARATION IS REQUIRED BETWEEN THE | | | INDUSTRIAL USE AREAS AND THE ASSEMBLY AREA | | | (RECEPTION/TASTING). ADDITIONALLY, THE OFFICE USE SPACE | | | OF THE SECOND FLOOR REQUIRES FIRE-RATED PROTECTION FROM | | | THE MODERATE/ORDINARY HAZARD INDUSTRIAL USE AREA | | | DIRECTLY BELOW. | | | | | | NFPA 101: 8.7 SPECIAL HAZARD PROTECTION. | | | 8.7.1 GENERAL. | | | 8.7.1.1* PROTECTION FROM ANY AREA HAVING A DEGREE OF | | | HAZARD GREATER THAN THAT NORMAL TO THE GENERAL | | | OCCUPANCY OF THE BUILDING OR STRUCTURE SHALL BE | | | PROVIDED BY ONE OF THE FOLLOWING MEANS: | | | (1) ENCLOSING THE AREA WITH A FIRE BARRIER WITHOUT | | | WINDOWS THAT HAS A 1-HOUR FIRE RESISTANCE RATING IN | | | ACCORDANCE WITH SECTION 8.3 | | | (2) PROTECTING THE AREA WITH AUTOMATIC EXTINGUISHING | | | SYSTEMS IN ACCORDANCE WITH SECTION 9.7 | | | (3) APPLYING BOTH 8.7.1.1(1) AND (2) WHERE THE HAZARD | | | IS SEVERE OR WHERE OTHERWISE SPECIFIED BY CHAPTERS 11 | | | THROUGH 43 | | | | | | 2) INTERIOR STAIR APPEARS TO BE "OPEN", LEADING DOWN | | | FROM AN AREA OF LOWER HAZARD TO AN AREA OF HIGHER | | | HAZARD. AS THIS STAIR IS PART OF THE MEANS OF EGRESS, | | | IT ALSO NEEDS TO BE REVIEWED AND PROVIDED WITH THE | | | PROPER SEPARATION. | | | | | | 3) PER YOUR NARRATIVE RESPONSE, YOU INDICATE THAT THE | | | RECEPTION/TASTING AREA WILL BE FOR "PRIVATE USE" AS A | | | "WORK AREA". HOWEVER, YOU HAVE PROVIDED AN OCCUPANCY | | | LOAD CALCULATION THAT EQUATES TO AN AREA THAT WILL BE | | | USED AS AN ASSEMBLY SPACE (1:15). PLEASE CLARIFY | | | COMMENTS. | | | WILL THIS AREA BE IN ANY WAY ACCESSIBLE TO PERSONS | | | OTHER THAN STAFF AND/OR DELIVERY PERSONNEL? IN OTHER | | | WORDS, WILL THE GENERAL PUBLIC HAVE ACCESS TO IT FOR | | | ANY REASON (I.E. PRIVATE EVENTS, SPECIAL EVENTS, | | | PURCHASE OF GOODS, TOURS, ETC.) | | | | | | 4) PROVIDE AN EXTERIOR KEY SAFE TO ALLOW EMERGENCY | | | RESPONDERS NON-FORCIBLE ENTRY INTO THE BUILDING DURING | | | NON-BUSINESS HOURS. A KEY SAFE CAN BE ORDERED FROM | | | WWW.KNOXBOX.COM. | | | | | | 5) SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE | | | INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER | | | SYSTEM AND/OR FIRE ALARM SYSTEM. | | | | | | 6) SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE | | | DELAYED EGRESS INSTALLATION. | | | | | | 7) ADDITIONAL PLAN REVIEW COMMENTS MAY BE GENERATED | | | DURING PLAN RESUBMISSION. | | | | | | SUE ELLEN CALDERON | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2018-07-05 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-07-05 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-07-05 |
Time |
08:34 |
Sent To |
|
|
| Notes |
| 2018-07-05 10:34:07 | PERMIT #18070030 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | 1) A LIFE SAFETY PLAN (SHEET A250) IS IDENTIFIED ON THE | | | SHEET INDEX, HOWEVER IT WAS NOT PROVIDED WITH THIS | | | SUBMISSION. | | | PLEASE PROVIDE A LIFE SAFETY PLAN SHOWING ALL OCCUPANCY | | | TYPES, OCCUPANT LOADS, FIRE RATED WALLS, EXIT SIGNS, | | | EMERGENCY LIGHTING, TRAVEL DISTANCES, COMMON PATH OF | | | TRAVEL ETC. | | | | | | 2) THE BUILDING IS FUNCTIONING AS A MULTIUSE OCCUPANCY. | | | INDICATE IF THE BUILDING IS DESIGNED FOR MIXED USE | | | (NON-SEPARATED) OR SEPARATED USE PER SECTION 6.1.14.3 | | | OF NFPA 101 FLORIDA EDITION 2015. FOR NON-SEPARATED | | | MIXED USE OCCUPANCIES, THE MOST STRINGENT FIRE AND LIFE | | | SAFETY REQUIREMENTS OF EACH OCCUPANCY SHALL APPLY TO | | | THE BUILDING. | | | | | | 3) PLEASE PROVIDE DETAILS REGARDING THE HAZARD OF | | | CONTENTS, AS DEFINED BY NFPA 101, CHAPTER 6. | | | 6.2 HAZARD OF CONTENTS. | | | 6.2.1 GENERAL. | | | 6.2.1.1 FOR THE PURPOSE OF THIS CODE, THE HAZARD OF | | | CONTENTS SHALL BE THE RELATIVE DANGER OF THE START AND | | | SPREAD OF FIRE, THE DANGER OF SMOKE OR GASES GENERATED, | | | AND THE DANGER OF EXPLOSION OR OTHER OCCURRENCE | | | POTENTIALLY ENDANGERING THE LIVES AND SAFETY OF THE | | | OCCUPANTS OF THE BUILDING OR STRUCTURE. | | | 6.2.1.2 HAZARD OF CONTENTS SHALL BE CLASSIFIED BY THE | | | REGISTERED DESIGN PROFESSIONAL (RDP) OR OWNER AND | | | SUBMITTED TO THE AUTHORITY HAVING JURISDICTION FOR | | | REVIEW AND APPROVAL ON THE BASIS OF THE CHARACTER OF | | | THE CONTENTS AND THE PROCESSES OR OPERATIONS CONDUCTED | | | IN THE BUILDING OR STRUCTURE. | | | 6.2.1.3* FOR THE PURPOSE OF THIS CODE, WHERE DIFFERENT | | | DEGREES OF HAZARD OF CONTENTS EXIST IN DIFFERENT PARTS | | | OF A BUILDING OR STRUCTURE, THE MOST HAZARDOUS SHALL | | | GOVERN THE CLASSIFICATION, UNLESS HAZARDOUS AREAS ARE | | | SEPARATED OR PROTECTED AS SPECIFIED IN SECTION 8.7 AND | | | THE APPLICABLE SECTIONS OF CHAPTERS 11 THROUGH 43. | | | | | | 6.2.2 CLASSIFICATION OF HAZARD OF CONTENTS. | | | 6.2.2.1* GENERAL. THE HAZARD OF CONTENTS OF ANY | | | BUILDING OR STRUCTURE SHALL BE CLASSIFIED AS LOW, | | | ORDINARY, OR HIGH IN ACCORDANCE WITH 6.2.2.2, 6.2.2.3, | | | AND 6.2.2.4. | | | 6.2.2.2* LOW HAZARD CONTENTS. LOW HAZARD CONTENTS SHALL | | | BE CLASSIFIED AS THOSE OF SUCH LOW COMBUSTIBILITY THAT | | | NO SELFPROPAGATING FIRE THEREIN CAN OCCUR. | | | 6.2.2.3* ORDINARY HAZARD CONTENTS. ORDINARY HAZARD | | | CONTENTS SHALL BE CLASSIFIED AS THOSE THAT ARE LIKELY | | | TO BURN WITH MODERATE RAPIDITY OR TO GIVE OFF A | | | CONSIDERABLE VOLUME OF SMOKE. | | | 6.2.2.4* HIGH HAZARD CONTENTS. HIGH HAZARD CONTENTS | | | SHALL BE CLASSIFIED AS THOSE THAT ARE LIKELY TO BURN | | | WITH EXTREME RAPIDITY OR FROM WHICH EXPLOSIONS ARE | | | LIKELY. (FOR MEANS OF EGRESS REQUIREMENTS, SEE SECTION | | | 7. 11.) | | | | | | 4) PLEASE PROVIDE THE MANUFACTURER'S | | | SPECIFICATIONS/DATA SHEET FOR ALL DISTILLNG AND BREWING | | | EQUIPMENT BEING USED. | | | | | | 5) PLEASE PROVIDE AN OUTLINE DETAILING THE DISTILLING | | | AND/OR BREWING PROCESS. | | | | | | 6) PLEASE BE ADVISED: WHERE A FIRE SPRINKLER AND/OR | | | FIRE ALARM SYSTEM IS REQUIRED PER THE FLORIDA FIRE | | | CODE, ENGINEERED FIRE ALARM AND FIRE SPRINKLER | | | CONSTRUCTION DOCUMENTS ARE REQUIRED FOR A GENERAL | | | BUILDING PERMIT. (SEE FLORIDA ADMINISTRATIVE CODE 61G15 | | | FOR FULL DETAIL REQUIREMENTS.) | | | AFTER THE BUILDING PERMIT HAS BEEN ISSUED, THE | | | SUBCONTRACTORS CAN THEN SUBMIT SHOP DRAWINGS | | | (CONFORMING TO THE ENGINEERED CONSTRUCTION DOCUMENTS) | | | FOR A SUB-PERMIT. | | | | | | 7) A THOROUGH AND COMPLETE PLAN REVIEW CANNOT BE | | | COMPLETED AT THIS TIME DUE TO LACK OF INFORMATION | | | SUBMITTED ON THE PLANS. ADDITIONAL PLAN REVIEW COMMENTS | | | MAY BE GENERATED DURING PLAN RESUBMISSION. | | | | | | | | | SUE ELLEN CALDERON | | | ASSISTANT FIRE MARSHAL | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 804-4751 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2018-11-29 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-11-29 |
Time |
16:59 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-11-29 |
Time |
16:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2018-09-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-09-28 |
Time |
06:41 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-09-27 |
Time |
08:01 |
Sent To |
|
|
| Notes |
| 2018-09-28 07:04:49 | 2ND REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | GAS COMMENTS: | | | | | | 1. PLEASE CLARIFY THE SYSTEM PRESSURE SHT. P103A UNDER | | | THE GAS CALCULATIONS LIST THE PRESSURE AT 2PSIOR LESS | | | IS IT 2 PSI OR IS IT LESS THAN 2 PSI. PER WPB AMEND TO | | | FBC 107.2.1 | | | | | | 2. SHT. P103A THE PLAN IS SHOWING THE METER AND | | | REGULATOR OUT SIDE THE NEW FENCE RIGHT IN FRONT OF THE | | | PARKING STOP PLEASE SHOW ON THE THE PLAN THAT THE GAS | | | RISER, METER AND REGULATOR ARE PROTECTED FROM DAMAGE | | | FROM VEHICLES WITH A SUBSTANTIAL TRAFFIC BALLARD. PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | 3. IT WILL BE REQUIRED TO SUBMIT BEFORE PERMIT ISSUE | | | TWO COPY'S OF THE MANUFACTURE SPECIFICATIONS AND | | | INSTALLATION GUIDE FOR THE BOILER AND REGULATOR THE | | | BOILER SPECS THAT WHERE PROVIDED DID NOT GIVE | | | INFORMATION ON THE STANDARDS THAT IT MEETS OR CLEARLY | | | SHOW INSTALLATION OUT DOORS. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-08-09 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-08-09 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-08-09 |
Time |
08:44 |
Sent To |
|
|
| Notes |
| 2018-08-09 09:10:57 | 1ST REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. HOW WILL THE GAS PIPING BE SECURED IT DOES NOT | | | APPEAR TO BE ANY WALLS OR OTHER SUPPORTS TO STRAP THE | | | PIPING TO PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | AND FBC FG 404.9 - 404.11.2 | | | | | | 3. PLEASE PROVIDE DETAILS OF HOW THE BOILER IS TIED | | | DOWN. PER FBC FG 301.10 AND COMPLIANCE WITH FBCFG | | | 301.11 | | | | | | 4. PROVIDE DOCUMENTATION THAT THE BOILER IS RATED FOR | | | EXTERIOR USE IN A WET LOCATION. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 5. SUBMIT A DETAIL SHOWING THE TYPE OF VENT, LOCATION, | | | SIZE, TERMINATION POINT, HEIGHT ABOVE THE ROOF AND | | | ANCHORING DETAILS OF THE GAS VENT(S) PER 2017 FBC-FUEL | | | GAS SECS. 502 THRU 505 OR 2017 FBC-RES. SEC.G2426 | | | THROUGH G2439. | | | | | | 6. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS / | | | INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY | | | COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | | FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2017 | | | FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED | | | AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS | | | APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF | | | INSPECTION. FGC SEC.305.1, FBC-RES. SEC.G2408.1. | | | | | | 7. PROVIDE SITE PLAN SHOWING LOCATION OF THE GAS METER | | | AND PIPING. PER WPB AMEND TO FBC 107.2.1 | | | | | | 8. PROVIDE DETAIL SHOW HOW THE GAS METER WILL BE | | | PROTECTED FROM VEHICULAR TRAFFIC. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2019-04-02 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-04-02 |
Time |
06:59 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-03-27 |
Time |
14:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-03-27 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-03-27 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-03-14 |
Time |
08:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-11-29 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-11-29 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-10-26 |
Time |
14:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-09-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-09-28 |
Time |
07:05 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-09-04 |
Time |
11:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-08-09 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-08-09 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-07-03 |
Time |
09:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2019-03-29 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-03-29 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-03-27 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2019-03-29 09:57:33 | RECEIPT MU-2019-9469 - $0.00 MONEY OWED | | 2019-03-27 15:22:32 | 3/27/19 EMAILED IMPACT FEE OFFICE. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2018-08-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-08-02 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-08-02 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2018-08-02 09:57:56 | THIS IS A CHANGE OF OCCUPANCY WHICH WILL REQUIRE THE | | | PLANS TO BE REVIEWED BY PALM BEACH COUNTY TO DETERMINE | | | IF ANY IMPACT FEES ARE REQUIRED TO BE PAID. | | | | | | IMPACT FEES - DIGITAL SUBMITTALS | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2019-03-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-03-28 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-03-28 |
Time |
10:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2019-03-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-03-21 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-03-21 |
Time |
08:58 |
Sent To |
|
|
| Notes |
| 2019-03-21 11:18:49 | 4TH REVIEW FBC-2017 MECHANICAL | | | PERMIT #18070030 | | | 9/19/18 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M-102: VERIFY THE DESIGN AND OPERATION OF THE | | | HAZARDOUS EXHAUST VENTILATION SYSTEM (AHU-1 AND EF-1) | | | IN THE DISTILLERY SHALL BE SUCH THAT FLAMMABLE | | | CONTAMINANTS ARE DILUTED IN NONCONTAMINATED AIR TO | | | MAINTAIN CONCENTRATIONS IN THE EXHAUST FLOW BELOW 25 | | | PERCENT OF THE CONTAMINANT'S LOWER FLAMMABILITY LIMIT. | | | HAS CAPTURE AND CONTAINMENT OF FLAMABLE VAPORS IN THEIR | | | HEAVIEST CONCENTRATIONSAROUND THE STILLS AND TANKS BEEN | | | TAKING INTO CONSIDERATION?- SECTION 502.1.1 FBC M. | | | | | | A) DESCRIBE THE SEQUENCE OF OPERATION FOR THE SYSTEM. | | | WILL THE SYSTEM RUN CONTINUOUSLY, OR INTERMITTENTLY | | | WHEN DISTILLERY OPERATIONS ARE BEING CONDUCTED? HOW | | | WILL THE NEW GAS SENSORS AFFECT THE OPERATION OF THE | | | VENTILATION SYSTEM. WILL THESE SENSORS BE LINKED TO THE | | | SYSTEM AND ALSO TO THE FIRE ALARM? | | | | | | 2) SUBMIT A REVISED ENERGY COMPLIANCE REPORT THAT | | | INLCUDES THE NEW AC SYSTEM AND THE CHANGES TO THE | | | BUILDING ENVELOPE. | | | | | | 3) PLEASE ADJUST THE TOTAL VALUE OF THE PROPOSED | | | PROJECT TO INCLUDE THE INCREASED COSTS ASSOCIATED WITH | | | THE NEW EXHAUST VENTILATION SYSTEM AND SENSORS IN THE | | | DISTILLERY- SECTION 109.3 FBC M. | | | | | | 4) PLEASE NOTE THE LIST OF PROVISOS FROM THE PREVIOUS | | | REVIEW. | | | | | | MECHANICAL PROVISOS. | | | 11/13/28 | | | | | | 1) PRESSURE TESTS FOR CHILLED WATER AND STEAM PIPING | | | REQUIRED. REQUIRED TEST PRESSURES SHALL BE PROVIDED BY | | | THE DISTILLERY SYSTEM MANUFACTURER AND THE ENGINEER OF | | | RECORD. | | | | | | 2) PROVIDE A LETTER FROM THE DISTILLERY SYSTEM | | | MANUFACTURER (CORSON) CERTIFYING THE EQUIPMENT- STILLS, | | | TANKS, PROCESS PIPINGS ETC.- ARE INSTALLED AND | | | FUNCTIONING IN ACCORDANCE WITH THE MANUFACTURER'S | | | GUIDELINES AND SPECIFICATIONS. THE LETTER SHALL BEAR | | | THE APPROVAL STAMPS OF THE ENGINEER AND ARCHITECT OF | | | RECORD. | | | | | | 3) SITE SPECIFIC WIND LOAD ENGINEERING FOR INSTALLATION | | | OF THE GLYCOL CHILLER AND OUTDOOR BOILER AND ASSOCIATED | | | EQUIPMENT SHALL BE SUBMITTED PRIOR TO INSPECTION. | | | | | | 6) MANUFACTURER'S SPECIFICATIONS AND INSTALLATION | | | INSTRUCTIONS FOR THE CHILLER, BOILER, AND THE CORSON | | | DISTILLERY SYSTEM SHALL BE ONSITE AT TIME OF | | | INSPECTION. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2018-11-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-11-13 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-11-05 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2018-11-13 09:49:42 | MECHANICAL PROVISOS. | | | 11/13/28 | | | | | | 1) PRESSURE TESTS FOR CHILLED WATER AND STEAM PIPING | | | REQUIRED. REQUIRED TEST PRESSURES SHALL BE PROVIDED BY | | | THE DISTILLERY SYSTEM MANUFACTURER AND THE ENGINEER OF | | | RECORD. | | | | | | 2) PROVIDE A LETTER FROM THE DISTILLERY SYSTEM | | | MANUFACTURER (CORSON) CERTIFYING THE EQUIPMENT- STILLS, | | | TANKS, PROCESS PIPINGS ETC.- ARE INSTALLED AND | | | FUNCTIONING IN ACCORDANCE WITH THE MANUFACTURER'S | | | GUIDELINES AND SPECIFICATIONS. THE LETTER SHALL BEAR | | | THE APPROVAL STAMPS OF THE ENGINEER AND ARCHITECT OF | | | RECORD. | | | | | | 3) SITE SPECIFIC WIND LOAD ENGINEERING FOR INSTALLATION | | | OF THE GLYCOL CHILLER AND OUTDOOR BOILER AND ASSOCIATED | | | EQUIPMENT SHALL BE SUBMITTED PRIOR TO INSPECTION. | | | | | | 4) A REVISED AC DUCT LAYOUT PLAN SHALL BE SUBMITTED FOR | | | ALL REQUIRED ALTERATIONS MADE TO THE EXISTING SYSTEMS. | | | | | | 5) THE RUM DISTILLERY PROCESS AND RUM STORAGE SHALL BE | | | IN ACCORDANCE WITH HAZARDOUS LIQUID GUIDELINES- | | | SECTIONS 307.1.2 & 414 FLORIDA BUILDING CODE SIXTH | | | EDITION- 2017, AND NFPA 30-2018. PLEASE NOTE THAT A | | | REVISION TO THE APPROVED MECHANICAL PLANS MAY BE | | | REQUIRED BASED ON ANY REQUIRED CHANGES TO THE | | | ARCHITECTURAL PLANS. | | | | | | 6) MANUFACTURER'S SPECIFICATIONS AND INSTALLATION | | | INSTRUCTIONS FOR THE CHILLER, BOILER, AND THE CORSON | | | DISTILLERY SYSTEM SHALL BE ONSITE AT TIME OF | | | INSPECTION. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2018-09-19 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-09-19 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-09-19 |
Time |
09:57 |
Sent To |
|
|
| Notes |
| 2018-09-19 13:19:05 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #18070030 | | | 9/19/18 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) BASED ON THE NOTES ON SHEET M-102 ABOUT THE | | | RELOCATION OF THE EXISTING AIR HANDLERS, A COMPLETE | | | REVIEW OF THE MECHANICAL PLANS CANNOT BE ACCOMPLISHED | | | WITHOUT THE NEW AIR HANDLER LOCATIONS SHOWN, AND A | | | COMPLETE AC LAYOUT PLAN PROVIDED FOR BOTH THE 1ST AND | | | 2ND FLOORS. MANY OF THE ROOMS AND SPACES ARE UNDERGOING | | | A CHANGE OF USE FROM THEIR PREVIOUS USES, AND | | | RECIRCULATION OF AIR FROM SOME OF THESE ROOMS AND | | | SPACES IS NOW PROHIBITED I.E THE LAB, AND THE | | | DISTILLERY- SEE TABLE 403.3.1.1. | | | | | | 2) SHEET M-102: THE EXHAUST VENTILATION CALCULATIONS | | | ARE INCOMPLETE. CALCULATIONS FOR THE LAB, AND THE 2ND | | | FLOOR OFFICES AND STORAGE ROOM WERE NOT PROVIDED. | | | CONCERNING THE LAB, PLEASE PROVIDE A NARRATIVE THAT | | | CLARIFIES THE PROCESSES THAT WILL TAKE PLACE IN THE LAB | | | AND WHAT CHEMICALS OR MATERIALS ARE USED AND STORED IN | | | THE LAB. PLEASE SEE SECTION 510.1 FBC M. CONCERNING THE | | | 2ND FLOOR STORAGE ROOM, CLARIFY WHAT MATERIALS WILL BE | | | STORED IN THE ROOM AND HOW IT WILL BRE VENTILATED. | | | | | | 3) M-102: REFER TO SECTION 510.9 FBC M AND INDICATE THE | | | TYPE OF EXHAUST DUCTWORK TO BE INSTALLED FOR THE LAB | | | AND THE BOTTLING ROOM. | | | | | | 4) M-102: IT APPEARS THE TERMINATIONS OF THE LAB AND | | | BOTTLING EXHAUST ARE NOT IN COMPLIANCE WITH REQUIRED | | | 10' CLEARANCE TO THE DOOR AND TO GRADE- SECTION 501.3.1 | | | FBC M. | | | | | | 5) M-102: A SURVEY WILL BE NEEDED TO DETERMINE IF THE | | | O/A INLET AND EXHAUST OUTLET ON THE WEST SIDE OF THE | | | BUILDING ARE 10' CLEAR OF THE PROPERTY LINE- SECTIONS | | | 401.4 AND 501.3.1 FBC M. | | | | | | 6) M-102: THE VENTILATION CALCULATION FOR THE TASTING | | | ROOM IS NOT IN COMPLIANCE WITH TABLE 403.3.1.1. THE | | | APPROPRIATE RATE SHALL BE BASED ON AN OCCUPANT DENSITY | | | OF 100 PERSONS PER S.F. X 7.5 CFMS PER PERSON + 0.18 | | | CFMS PER SQ. FT. PLEASE CORRECT. | | | | | | 7) THE LOUVER NOA SUBMITTAL IS MISSING PAGE 1. | | | | | | 8) THE SUBMIITED SPECS FOR THE RITE BOILER DO NOT | | | PROVIDE ANY LISTING INFORMATION AS REQUIRED BY SECTION | | | 631.1 FBC FG, OR INDICATE THE UNIT CAN BE INSTALLED ON | | | THE EXTERIOR OF THE BUILDING. THE SPECS ARE INDICATING | | | AN INTERIOR INSTALLATION. | | | | | | 9) NO ADDITIONAL INFORMATION HAS BEEN SUBMITTED AS | | | REQUESTED FOR THE DISTILLERY TANKS, KETTLES, AND | | | STILLS. IT IS STILL NOT CLEAR IF THE EQUIPMENT HAS BEEN | | | TESTED IN ACCORDANCE WITH ANY LISTING AGENCY OR TESTING | | | STANDARD- PLEASE PROVIDE ADDITIONAL INFORMATION. | | | | | | 10) CLARIFY IF VENTING OF THE STILLS, TANKS, AND | | | KETTLES IS REQUIRED, AND REVISE THE PLANS ACCORDINGLY | | | TO SHOW LOCATIONS AND VENTING DETAILS. | | | | | | 11) THE SUBMITTED SPECS FOR THE BOTTLING MACHINE | | | INDICATE THE USE OF CO2 AND OXYGEN TANKS. CLARIFY IF | | | TANKS WILL BE STORED AT THE FACILITY AND SHOW WHERE AND | | | HOW THEY WILL BE STORED IF APPLICABLE. | | | | | | LISTED BELOW ARE COMMENTS FROM THE FIRST REVIEW THAT | | | STILL EXIST- PLEASE COMPLY. | | | | | | 8) PROVIDE WIND LOAD ENGINEERING AND INSTALLATION | | | DETAILS FOR THE CHILLER, BOILER, PUMPS, AND ALL OTHER | | | ASSOCIATED EXTERIOR EQUIPMENT AND SUPPORTS SHOWN ON | | | SHEET M-100- SECTION 301.15 FBC M. | | | | | | 10) PLEASE PROVIDE A PLAN THAT SHOWS THE REQUIRED | | | WORKING CLEARANCES AROUND THE STILLS, KETTLES, AS | | | REQUIRED BY THE LISTING AGENCY OR THE MANUFACTURER, AND | | | CLARIFY IF THE EXISTING SLAB HAS BEEN EVALUATED FOR THE | | | INCREASED LOADS OF THE DISTILLERY EQUIPMENT- SECTION | | | 107.2.1 WPB. | | | | | | 11) CLARIFY IF THE EXISTING SLAB HAS BEEN EVALUATED FOR | | | THE INCREASED LOADS OF THE DISTILLERY TANKS, KETTLES, | | | STILLS ETC, AND PROVIDE ANCHORING DETAILS. | | | | | | 12) THE $320,000.00 PERMIT VALUE APPEARS TO BE LOW FOR | | | THE SCOPE OF THE PROPOSED PROJECT. PLEASE PROVIDE | | | CONTRACTS, INVOICES, ESTIMATES ETC. THAT SHOW THE TOTAL | | | COST OF THE PROJECT INCLUDING, LABOR, MATERIALS, | | | EQUIPMENT, APPLIANCES, FIXTURES, DESIGN FEES, SITE | | | WORK, OVERHEAD AND PROFIT- SECTION 109.3 WPB. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-07-17 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-07-17 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-07-17 |
Time |
17:10 |
Sent To |
|
|
| Notes |
| 2018-07-17 17:36:07 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #18070030 | | | 7/17/18 | | | | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) IN ORDER TO PROVIDE A COMPLETE REVIEW, THE ARCHITECT | | | OF RECORD SHALL PROVIDE A LIFE SAFETY PLAN WHICH SHALL | | | INCLUDE THE OCCUPANCY CLASSIFCATION(S) OF THE FACILITY, | | | OCCUPANT LOAD, FIRE SPRINKLER CLASSIFICATION, LOCATION | | | OF FIRE SEPARATIONS AND HOURLY FIRE-RATINGS, | | | FIRESTOPPING FOR PIPES, CONDUITS, AND DUCTWORK, EGRESS | | | PATHS AND TRAVEL DISTANCES, ETC.- SECTION 107.2.1 WPB. | | | | | | 2) IN ORDER TO PROVIDE A COMPLETE REVIEW, THE ARCHITECT | | | SHALL INDICATE THE CLASSIFCATION OF WORK AS OUTLINED IN | | | CHAPTER 5 FBC EX. THIS APPEARS TO BE A CHANGE OF | | | OCCUPANCY AS DEFINED IN SECTION 202 FBC EX. PLEASE SEE | | | SECTION 506 AND CHAPTER 10 FOR ALL REQUIREMENTS. | | | | | | 3) M-100: SUBMIT MANUFACTURER'S SPECIFICATIONS AND/OR | | | CUT SHEETS FOR ALL EQUIPMENT LISTED IN THE SCHEDULE | | | INCLUDING THE CHILLER, BOILER, STILLS ETC. THE SPECS | | | SHALL INDICATE THE LISTING AND LABELING, OR TESTING | | | STANDARD APPLIED TO EACH PIECE OF EQUIPMENT- SECTION | | | 107.2.1 WPB. | | | | | | 4) M-101: SHOW PIPING RUN FROM MAKEUP WATER UNIT TO THE | | | CHILLER. | | | | | | 5) SHEET M-102: PLEASE INCLUDE VENTILATION CALCULATIONS | | | FOR THE LAB, BOTTLING ROOM, AND RECEPTION/TASTING ROOM- | | | SEE SECTION 809.2 FBC EX, AND TABLE 403.1.1 FBC M. | | | PLEASE NOTE THAT THE LAB ROOM REQUIRES EXHAUST | | | VENTILATION PER TABLE 403.1.1. | | | | | | 6) M-102: THE LOUVER SCHEDULE INDICATES "CART STORAGE | | | AREA" WHICH APPEARS TO BE AN INCORRECT IDENTIFCATION OF | | | THE DISTILLING AND PROCESSING AREA. PLEAE PROVIDE A | | | FLORIDA PRODUCT APPROVAL OR MIAMI-DADE NOA FOR THE | | | LOUVER. | | | | | | 7) M-103: PROVIDE COMBUSTION AIR CALCULATIONS FOR THE | | | GAS-FIRED STILLS, AND INDICATE HOW THE COMBUSTION AIR | | | WILL BE PROVIDED- SECTION 304 FBC FG. | | | | | | 8) PROVIDE WIND LOAD ENGINEERING AND INSTALLATION | | | DETAILS FOR THE CHILLER, BOILER, PUMPS, AND ALL OTHER | | | ASSOCIATED EXTERIOR EQUIPMENT AND SUPPORTS SHOWN ON | | | SHEET M-100- SECTION 301.15 FBC M. | | | | | | 9) M-003 & M-104: INCLUDE THE TRYMER PIPE INSULATION IN | | | THE SPECIFICATIONS, AND ON WHICH PIPING SYSTEMS THE | | | INSULATION IS TO BE INSTALLED- CHILLER OR BOILER | | | PIPING, OR BOTH. INDICATE THE THICKNESS OF INSULATION | | | TO BE INSTALLED AND CLARIFY IF THE INSULATION IS TESTED | | | AND RATED FOR EXTERIOR USE, OR IF ANOTHER PRODUCT WILL | | | BE USED FOR THE EXTERIOR PIPING- SEE SECTION C403.2.10 | | | FBC EC. | | | | | | 10) PLEASE PROVIDE A PLAN THAT SHOWS THE REQUIRED | | | WORKING CLEARANCES AROUND THE STILLS, KETTLES, AS | | | REQUIRED BY THE LISTING AGENCY OR THE MANUFACTURER, AND | | | CLARIFY IF THE EXISTING SLAB HAS BEEN EVALUATED FOR THE | | | INCREASED LOADS OF THE DISTILLERY EQUIPMENT- SECTION | | | 107.2.1 WPB. | | | | | | 11) CLARIFY IF THE EXISTING SLAB HAS BEEN EVALUATED FOR | | | THE INCREASED LOADS OF THE DISTILLERY TANKS, KETTLES, | | | STILLS ETC, AND PROVIDE ANCHORING DETAILS. | | | | | | 12) THE $320,000.00 PERMIT VALUE APPEARS TO BE LOW FOR | | | THE SCOPE OF THE PROPOSED PROJECT. PLEASE PROVIDE | | | CONTRACTS, INVOICES, ESTIMATES ETC. THAT SHOW THE TOTAL | | | COST OF THE PROJECT INCLUDING, LABOR, MATERIALS, | | | EQUIPMENT, APPLIANCES, FIXTURES, DESIGN FEES, SITE | | | WORK, OVERHEAD AND PROFIT- SECTION 109.3 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2019-04-02 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-04-02 |
Time |
06:59 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-04-02 |
Time |
06:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-11-29 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-11-29 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-11-29 |
Time |
17:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-09-27 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-09-27 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-09-27 |
Time |
08:01 |
Sent To |
|
|
| Notes |
| 2018-09-27 17:43:11 | 2ND REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. GRAB BARS SHALL BE SHOWN TO BE MEASURED TO THE TOP | | | OF THE GRIPPING SURFACE FROM FINISH FLOOR. PER FBC ACC | | | 609.4 | | | | | | 2. TOILET PAPER DISPENSERS SHALL BE 7 INCHES MINIMUM | | | AND 9 INCHES MAXIMUM IN FRONT OF THE WATER CLOSET | | | MEASURED TO THE CENTERLINE OF THE DISPENSER. PER FBC | | | ACC 604.7 | | | | | | 3. THE SINK NEXT TO THE BATHROOM APPEARS TO BE NEW IT | | | DOES NOT APPEARS ON PREVIOUS PLANS IN OUR PERMIT | | | RECORDS IT SHALL COMPLY WITH FBC ACC 212.2, 212.3 | | | 606.2 CLEAR FLOOR SPACE.A CLEAR FLOOR SPACE COMPLYING | | | WITH 305, POSITIONED FOR A FORWARD APPROACH, AND KNEE | | | AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE PROVIDED. | | | 606.3 HEIGHT.LAVATORIES AND SINKS SHALL BE INSTALLED | | | WITH THE FRONT OF THE HIGHER OF THE RIM OR COUNTER | | | SURFACE 34 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR | | | GROUND. | | | | | | 4. SHT P-102 UNDER THE FIXTURE SCHEDULE FS-1 NEEDS TO | | | BE REMOVED IF THE OUTDOOR FLOOR SINK WAS DELETED , WC | | | HAS THE SPECIFICATIONS FOR THE LAVATORY PLEASE COMPLY. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | 5. YOU ARE MISSING THE MANUFACTURE SPECIFICATIONS FOR | | | THE ETP PLEASE PROVIDE SPECS FOR THE ZURN Z1020LF AND | | | THE BACFLOW FEBCO 850 ALL VALVES AND DEVICES FITTINGS | | | AND PIPE CONNECT TO THE POTABLE WATER SYSTEM SHALL BE | | | LEAD FREE PER FBC PL 605.2.1 PLACE NOTE ON PLAN | | | | | | 6. BACKFLOW REQUIRED ON CW CONNECTION TO THE CHILLED | | | WATER SYSTEM. PER FBC PL 608.3 | | | | | | 7. THE PREVIOUS PLANS IN OUR PERMIT RECORDS SHOWS A | | | SRVICE SINK ON THE BACKSIDE OF THE LAVATORY AND A WATER | | | COOLER IF THESE HAVE BEEN REMOVED AT SOME POINT IT IS | | | REQUIRED TO HAVE THEM PER THE FBC PL TABLE 308.5 AND | | | SHALL COMPLY WITH CURRENT CODE. | | | | | | 8. SHT P -103 APPEARS TO HAVE BEEN REPLACED BY SHEET | | | P-103A PLEASE REMOVE ALL OLD SHEETS. PER WPB AMEND TO | | | FBC 107.2.1 | | | | | | 9. SEE MECHANICALLY COMMENTS FOR DISTILLING EQUIPMENT | | | COMMENTS SHALL COMPLY PER WPB AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-08-09 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-08-09 |
Time |
06:30 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-08-07 |
Time |
16:01 |
Sent To |
|
|
| Notes |
| 2018-08-09 08:37:36 | 1ST REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PLEASE INDICATE THE TYPE OF OCCUPANCY ON THE PLAN. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | 2. PLEASE INDICATE ON THE PLAN THE LEVEL OF ALTERATION | | | IT APPEARS TO BE A CHANGE OF OCCUPANCY FROOM A BUSINESS | | | TO AN F-1 AND THERE FOR SHALL COMPLY WITH FBC EX CH 10 | | | | | | 3. LIST OCCUPANT LOAD ON PLAN. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 4. THIS ALTERATION SHALL COMPLY WITH FBC ACC 202.4 | | | PLEASE PROVIDE A COST BREAK DOWN TO SHOW COMPLIANCE. | | | PER FBC ACC 202.4.1, 202.4.2 | | | | | | 5. PROVIDE MANUFACTURE SPECIFICATIONS FOR ETP, WATER | | | SOFTENER AND THE CONDENSATE RETURN WATER SYSTEM. PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | 6. PLEASE PROVIDE MANUFACTURE SIZING CALCULATIONS FROM | | | SCHIER FOR THE GREASE INTERCEPTOR. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 7. THE FLOOR DRAIN NEXT TO THE BOILER IS NOT VENTED. | | | PER FBC PL 901.2.1 | | | | | | 8. THE FLOOR DRAIN NEXT TO THE BOILER APPEARS TO BE ON | | | THE EXTERIOR OF THE BUILDING THE SANITARY SHALL NOT | | | RECEIVE RAIN WATER HOW WILL THIS FLOOR DRAINBE | | | PROTECTED FROM RECEIVING RAIN WATER. PER CITY OF WEST | | | PALM BEACH CODE O ORDINANCE SEC. 90-126.(5) | | | | | | 9. SHT PP-101 THE BOILER IS MISSING THE WATER | | | CONNECTION ON THE FLOOR PLAN AND THE WATER ISOMETRIC | | | PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 10. A BACK FLOW IS REQUIRED ON THE EPT AND THE | | | CONDENSATE RETURN FEED WATER SYSTEM. PER FBC PL 608.3 | | | | | | 11. SHT P-104 DETAIL B SHOWS A SHELF BRACKET WITH A | | | RATING OF 150LBS A 45GAL WATER HEATER WEIGHS OVER | | | 400LBS WHEN IT IS FULL PLEASE PROVIDE A PLATFORM SYSTEM | | | THAT EXCEEDS THIS WEIGHT. PER WPB AMEND TO FBC 107.2.1 | | | | | | 12. SHT. P-104 DETAIL G AND M SHOW A SINGLE TRAP PRIMER | | | VALVE THE WATER ISOMETRIC SHOWS A LARGE MULTI PORT | | | ELECTRONIC TRAP PRIMER VALVE PLEASE CLARIFY. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2019-03-28 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2019-03-28 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2019-03-28 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2019-03-28 10:55:36 | MECH SHEETS GOOD |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2019-03-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-03-26 |
Time |
18:05 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-03-21 |
Time |
08:27 |
Sent To |
|
|
| Notes |
| 2019-03-26 18:06:25 | BLDG SHEETS OK | | | NEW SHEETS SUBMITTED NEXT REVIEW REQUIRE VERIFICATION | | | | | 2019-03-21 08:27:40 | MECH SHEETS OK | | 2019-03-16 09:07:00 | ELECTRICAL SHEETS OK. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2018-11-01 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-11-01 |
Time |
08:02 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-11-01 |
Time |
08:02 |
Sent To |
|
|
| Notes |
| 2018-11-01 08:02:20 | PLAN IS REQUIRED TO BE SIGNED AND SEALED BY THE PERSON | | | RESPONSIBLE FOR THE DESIGN. A DIGITAL PLAN REQUIRES A | | | DIGITAL SIGNATURE. PROVIDE CORRECTION. WPB FBC 107.1; | | | FS 471/481 | | | | | | THE FOLLOWING SHEETS HAVE A CORRUPTED SIGNATURE: | | | | | | E002, E003, E100, E101, E105, FA100, FA101, M002, M003, | | | M101, M104, M105, M106, M107, M108, M109, M110, M111, | | | M112, P001, P002, P003, P004, P103, P103B, P104, P105. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2018-09-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-05 |
Time |
18:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-05 |
Time |
18:21 |
Sent To |
|
|
| Notes |
| 2018-09-05 18:28:53 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | ENERGY CALCS OK | | | A SHEETS OK | | | | | | ALL MEP SHEETS EXCEPT FOR E001 HAVE AN INVALID | | | SIGNATURE (ALTERED OR CORRUPTED SINCE THE SIGNATURE WAS | | | APPLIED) | | | | | | AFTER ALL PLAN REVIEWS HAVE PASSED, SEND A CORRECTLY | | | SIGNED PDF WITH ALL MEP PAGES VIA EMAIL TO: | | | | | | [email protected] | | | [email protected] | | | | | | IN THE SUBJECT LINE OF THE EMAIL INCLUDE THE PERMIT | | | NUMBER AND "SIGNATURE DOCUMENTS" | | | | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2019-03-27 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-03-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2019-03-27 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-03-27 16:57:07 | ZONING PROVISO: | | | | | | 1.) SEPARATE PERMITS REQUIRED FOR: LANDSCAPING, PARKING | | | LOT PAVEMENT STRIPING, WALL/FENCE, PRIOR TO THE | | | ISSUANCE OF A CERTIFICATE OF OCCUPANCY (C.O.). | | | | | | | | | NOTES: | | | | | | * TOTAL VALUE OF PROJECT (TO DATE): INTERIOR BUILDOUT | | | (#18070030) $410, 250 + INTERIOR DEMO (#18071011) | | | $2,350 = $412,600. | | | | | | * CURRENT VALUE OF EXISTING STRUCTURE = $698,684 (2018 | | | PAPA). VALUE OF THE PROJECT EXCEEDS 50% VALUE OF THE | | | STRUCTURE. THEREFORE, UPGRADE TO LANDSCAPING (TO MEET | | | ZLDRS), TO THE GREATEST EXTENT POSSIBLE, IS REQUIRED. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2019-03-27 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-03-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2019-03-27 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-03-27 10:21:10 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) FLOOR PLANS DO NOT MATCH ELEVATIONS. PLEASE | | | CORRECT. | | | | | | NOTES: | | | | | | * SEPARATE PERMITS REQUIRED FOR: LANDSCAPING, PARKING | | | LOT/PAVEMENT STRIPING, WALL/FENCE. | | | | | | * NO STRUCTURES (I.E. WALL/FENCE) SHALL BE BUILT WITHIN | | | THE 6 FT. WIDE FPL EASEMENT, UNLESS A HOLD HARMLESS | | | AGREEMENT IS PROVIDED TO THE CITY. | | | | | | * TOTAL VALUE OF PROJECT (TO DATE): INTERIOR BUILDOUT | | | (#18070030) $410, 250 + INTERIOR DEMO (#18071011) | | | $2,350 = $412,600. | | | | | | * CURRENT VALUE OF EXISTING STRUCTURE = $698,684 (2018 | | | PAPA). VALUE OF THE PROJECT EXCEEDS 50% VALUE OF THE | | | STRUCTURE. THEREFORE, UPGRADE TO LANDSCAPING (TO MEET | | | ZLDRS), TO THE GREATEST EXTENT POSSIBLE, IS REQUIRED. | | | | | | * REVISIONS MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * ZONE: I | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-11-13 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2018-11-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2018-11-13 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-11-13 15:47:58 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) UPDATED SIGNED AND SEALED SURVEY IS MISSING FROM | | | THE PERMIT PACKET. PLEASE PROVIDE. | | | | | | 2.) PROPOSED NEW STRUCTURES AT THE REAR OF THE PROPERTY | | | (CHILLER/BOILER) SHALL BE SETBACK AT LEAST 5 FT. FROM | | | THE PROPERTY LINE(S) | | | | | | 3.) EXISTING FLOOR PLAN OF THE SECOND LEVEL IS MISSING. | | | PLEASE PROVIDE SO THAT STAFF CAN COMPARE THE EXISTING | | | SECOND FLOOR LAYOUT TO THE PROPOSED SECOND FLOOR | | | LAYOUT. | | | | | | 4.) PROPOSED BUILDING ELEVATIONS SEEM TO BE MISSING | | | FROM THE PERMIT SUBMITTAL. PLEASE PROVIDE. | | | | | | | | | NOTES: | | | | | | * SEPARATE PERMITS REQUIRED FOR: LANDSCAPING, PARKING | | | LOT/PAVEMENT STRIPING, WALL/FENCE. | | | | | | * NO STRUCTURES (I.E. WALL/FENCE) SHALL BE BUILT WITHIN | | | THE 6 FT. WIDE FPL EASEMENT, UNLESS A HOLD HARMLESS | | | AGREEMENT IS PROVIDED TO THE CITY. | | | | | | * TOTAL VALUE OF PROJECT (TO DATE): INTERIOR BUILDOUT | | | (#18070030) $410,250 + INTERIOR DEMO (#18071011) $2,350 | | | = $412,600. | | | | | | * CURRENT VALUE OF EXISTING STRUCTURE = $698,684 (2018 | | | PAPA). VALUE OF PROJECT EXCEEDS 50% VALUE OF THE | | | STRUCTURE. THEREFORE, UPGRADE TO LANDSCAPING (TO MEET | | | ZLDRS), TO THE GREATEST EXTENT POSSIBLE, IS REQUIRED. | | | | | | * REVISION MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * ZONE: I | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | |
|
|
|