Plan Review Details - Permit 18061450
Plan Review Stops For Permit 18061450
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-07-25 Cont ID  
Sent By cthroop Date 2018-07-25 Time 08:37 Rev Time 0.00
Received By dbattles Date 2018-07-23 Time 14:53 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2018-07-23 Cont ID  
Sent By jleahy Date 2018-07-23 Time 13:42 Rev Time 0.00
Received By jpearson Date 2018-07-23 Time 11:13 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2018-08-08 Cont ID  
Sent By tklarge Date 2018-08-08 Time 11:00 Rev Time 0.00
Received By tklarge Date 2018-08-08 Time 10:59 Sent To I
Notes
2018-08-08 11:01:52A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT
 THIS TIME. A SEPARATE GAS PERMIT IS REQUIRED FOR A
 CONTRACTOR TO PERFORM THE RELATED WORK. PROVIDE
 COMPLETE PLANS THAT REFLECT THE ENTIRE SCOPE OF GAS
 WORK TO BE DONE. WPB AMEND. TO FBC SEC.107.2.1.
  
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE
 FBC-R, SEC. G2404.3.
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL
 GAS SEC. 301.3.
  
 A SEPARATE PERMIT IS REQUIRED FOR THE GAS INSTALLATION.
 NOTE: GAS PERMIT APPLICATION #18060877 HAS BEEN
 SUBMITTED AND FAILED PLAN REVIEW.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2018-07-05 Cont ID  
Sent By fmittner Date 2018-07-05 Time 15:47 Rev Time 0.00
Received By fmittner Date 2018-07-05 Time 15:47 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-08-15 Cont ID  
Sent By hmoser Date 2018-08-15 Time 14:59 Rev Time 0.00
Received By hmoser Date 2018-08-14 Time 14:44 Sent To  
Notes
2018-08-15 14:44:22RESUB ROUTED TO HMOSER

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-08-11 Cont ID  
Sent By hmoser Date 2018-08-11 Time 10:44 Rev Time 0.00
Received By hmoser Date 2018-08-08 Time 09:38 Sent To  
Notes
2018-08-10 09:38:46RESUB ROUTED TO HMOSER

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-08-08 Cont ID  
Sent By tklarge Date 2018-08-08 Time 11:01 Rev Time 0.00
Received By tklarge Date 2018-06-29 Time 16:11 Sent To  
Notes
2018-07-02 16:11:22R32

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2018-08-15 Cont ID  
Sent By hmoser Date 2018-08-15 Time 14:59 Rev Time 0.00
Received By hmoser Date 2018-08-15 Time 14:59 Sent To I
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2018-08-11 Cont ID  
Sent By hmoser Date 2018-08-11 Time 10:43 Rev Time 0.00
Received By hmoser Date 2018-08-11 Time 10:40 Sent To I
Notes
2018-08-11 10:43:44PLAN DENIED
 ENERGY CALCULATIONS MUST BE SIGNED BY OWNER AGENT
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-07-30 Cont ID  
Sent By hmoser Date 2018-07-30 Time 10:53 Rev Time 0.00
Received By hmoser Date 2018-07-30 Time 10:35 Sent To  
Notes
2018-07-30 10:53:32REVISION DENIED
 AIR CONDITIONING SYSTEM WAS CHANGED FROM SPLIT SYSTEM
 TO MINI SPLIT.
 ENERGY CALCULATIONS MUST BE REVISED. 107 FBC 2017
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2018-08-08 Cont ID  
Sent By tklarge Date 2018-08-08 Time 10:59 Rev Time 0.00
Received By tklarge Date 2018-08-08 Time 10:33 Sent To  
Notes
***NONE***