 |
Plan Review Details - Permit 18061371
| Plan Review Stops For Permit 18061371 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-10-19 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-10-19 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-10-19 |
Time |
13:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-08-01 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-08-01 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-08-01 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2018-08-01 16:25:10 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 18061371 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. [FBC 107.3.4.1]PROVIDE PRODUCT APPROVALS FOR | | | WINDOWS, DOORS AND SHUTTER SYSTEMS, OR INDICATE THAT | | | YOU WOULD LIKE THEM DEFFERED. | | | | | | 2. [FBC 107.3.5.3]PROVIDE +/- PRESSURES FOR ALL | | | OPENINGS BASED ON DESIGN CRITERIA . | | | | | | 3. IS THE ROOF BEING REPLACED. IF SO, PROVIDE PRODUCT | | | APPROVALS. | | | | | | NOTE: | | | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | | OF MATERIALS REQUESTED. | | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-12-10 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-12-11 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-12-10 |
Time |
13:20 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-09-26 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-09-26 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-09-25 |
Time |
16:30 |
Sent To |
|
|
| Notes |
| 2018-09-26 08:29:04 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. CORRECTED. | | | 2. CORRECTED. | | | 3. CORRECTED. | | | 4. CORRECTED, SHOWN ON PERMIT 15070145. | | | 5. CORRECTED, SHOWN ON PERMIT 15070145. | | | 6. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 (NOTE 3 | | | ON SHEET E-3 STATES THAT RECEPTACLES SHALL BE TAMPER | | | RESISTANT PER NEC 406.11. THIS CODE SECTION DOES NOT | | | APPLY TO TAMPER RESISTANT RECEPTACLES. PROVIDE | | | CORRECTION. NEC 406.12; FBC RE E4002.14) | | | 7. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. PROVIDE | | | CORRECTION. NEC 210.12; FBC RE E3902.16 (NOTE 2 ON | | | SHEET E-3 DOES NOT INCLUDE THE ALL AREAS REQUIRED TO BE | | | AFCI PROTECTED. PROVIDE CORRECTION.) | | | 8. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | | FBC EC C405.1, R404.1 (THIS NOTE WAS ADDED TO SHEET | | | E-2, BUT A CONFLICTING NOTE EXIST ON SHEET E-3. CORRECT | | | DISCREPANCY. WPB FBC 107.2.1) | | | 9. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | (LOAD CALCULATION WAS PROVIDED ONLY FOR GARAGE PANEL, | | | NOT ENTIRE SERVICE. BE ADVISED THAT DEMAND FACTORS USED | | | CANNOT BE APPLIED TO THE GARAGE PANEL AS IT IS NOT FEED | | | BY A 100 AMP FEEDER. NEC 220.82; FBC RE3602.2.1. | | | ADDITIONALLY, UPON RESEARCHING PERMIT 15070145, I SEE | | | THAT THE STATED LOAD ON THE SERVICE IS 175 AMPS, WITH | | | 10 AMPS INCLUDED FOR THE GARAGE. NOW, WITH THE | | | ADDITIONAL LOAD OF THE GARAGE, BASED ON THESE NUMBERS | | | AND THE PROPER CALCULATION FOR THE GARAGE PANEL, THE | | | SERVICE WILL BE OVERLOADED. PROVIDE CORRECTION AND | | | PROVIDE ACCURATE LOAD CALCULATION AS PREVIOUSLY | | | REQUESTED. NEC 220; FBC RE 3602) | | | 10. CORRECTED. | | | | | | NEW COMMENT: | | | | | | 11. AN ARCHITECT HAS SIGNED AND SEALED THE "E" SHEETS. | | | PROVIDE CORRECTION. FS 471.003(2)(H), 471.025; WPB FBC | | | 107.1 | | | 12. THE CABANA MEETS THE DEFINITION OF A BEDROOM IN THE | | | FLORIDA STATUTES AND SHOULD HAVE A SMOKE ALARM | | | INSTALLED. FS 381.0065; FBC RE R314.3 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-07-26 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-07-26 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-07-26 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2018-07-26 14:15:34 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | | 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 | | | 2. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | | 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1, | | | E3609.3; WPB FBC 107.2.1 | | | 3. A BUILDING OR OTHER STRUCTURE THAT IS SERVED BY A | | | BRANCH CIRCUIT OR FEEDER ON THE LOAD SIDE OF A SERVICE | | | DISCONNECTING MEANS SHALL BE SUPPLIED BY ONLY ONE | | | FEEDER OR BRANCH CIRCUIT. NEC 225.30 | | | 4. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | | STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR | | | MAIN BREAKER AT THIS PANEL. NEC 225.31, 225.32 | | | 5. PROVIDE GROUNDING ELECTRODE SYSTEM AS REQUIRED FOR A | | | BUILDING OR STRUCTURE SUPPLIED BY A FEEDER OR BRANCH | | | CIRCUIT. NEC 250.32; FBC RE3607.3 | | | 6. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 | | | 7. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. PROVIDE | | | CORRECTION. NEC 210.12; FBC RE E3902.16 | | | 8. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | | FBC EC C405.1, R404.1 | | | 9. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | 10. PROVIDE GFCI PROTECTED OUTLET FOR SERVICING OF A/C | | | EQUIPMENT WITHIN 25 FEET OF THE EQUIPMENT PER CODE. NEC | | | 210.63; FBC RE E3901.12 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-10-19 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-10-19 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-10-19 |
Time |
14:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-07-09 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2018-07-09 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2018-07-09 |
Time |
14:40 |
Sent To |
B |
|
| Notes |
| 2018-07-09 14:40:38 | 7/9/2018 - MEETS CONDITIONS OF APPROVAL OUTLINED IN HPB | | | CASE NO. 18-36. DLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2018-12-28 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-12-28 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-12-26 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2018-12-27 11:44:13 | IMPACT FEES ROUTED TO DBATTLES |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-12-11 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-12-11 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-12-07 |
Time |
11:27 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-10-19 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-10-19 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-09-11 |
Time |
11:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-08-21 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-08-21 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-06-28 |
Time |
16:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2018-12-28 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-12-28 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-12-28 |
Time |
08:17 |
Sent To |
|
|
| Notes |
| 2018-12-28 08:18:54 | PLANS STAMPED - OK | | | MU-2018-041791-0000 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2018-12-11 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-12-11 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-12-11 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2018-12-11 15:09:06 | PLEASE CHECK OUT ONE SET OF PLANS TO TAKE TO PALM BEACH | | | COUNTY FORI IMPACT REVIEW. | | | RETURN THE PLANS WITH PBC STAMP AND COPY OF RECEIPT. | | | | | | [FBC AMENDED 109] PLANS REQUIRE REVIEW BY THE PBC | | | IMPACT FEE OFFICE. CALL (561) 233-5025. UPON APPROVAL, | | | YOU MAY CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE | | | FOR REVIEW. PLEASE RETURNED STAMPED AND WITH A COPY OF | | | THE RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE | | | OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO | | | V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN | | | AIRE.PDF |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2018-08-21 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-08-21 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-08-21 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2018-08-21 15:01:23 | [FBC AMENDED 109] PLANS REQUIRE REVIEW BY THE PBC | | | IMPACT FEE OFFICE. CALL (561) 233-5025. UPON APPROVAL, | | | YOU MAY CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE | | | FOR REVIEW. PLEASE RETURNED STAMPED AND WITH A COPY OF | | | THE RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE | | | OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO | | | V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN | | | AIRE.PDF |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-10-11 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-10-11 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-10-11 |
Time |
13:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-08-03 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-08-03 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-08-03 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2018-08-03 14:41:26 | MECHANICAL PLAN REVIEW FAIL | | | | | | 1 - NEED MECHANICAL LOAD CALCULATIONS PER 2017 FLORIDA | | | BUILDING CODE - RESIDENTIAL SEC. M1401.3 EQUIPMENT AND | | | APPLIANCE SIZING |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-10-19 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-10-19 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-10-19 |
Time |
14:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-07-09 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2018-07-09 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2018-07-09 |
Time |
14:39 |
Sent To |
HIST |
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |