|
 |
 |
 |
 |
 |
Plan Review Details - Permit 18061278
| Plan Review Stops For Permit 18061278 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2018-07-24 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-07-24 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-07-24 |
Time |
13:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-07-24 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-07-24 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-07-24 |
Time |
13:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-07-23 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-07-23 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-07-23 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2018-07-23 15:28:25 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. A GFCI PROTECTED RECEPTACLE OUTLET ON A 20 AMP | | | CIRCUIT IS REQUIRED WITHIN 3 FEET OF EACH BASIN. | | | PROVIDE CORRECTION. NEC 210.11(C)(3), 210.52(D) | | | 2. GFCI PROTECTION IS REQUIRED FOR ALL RECEPTACLE | | | OUTLETS IN BATHROOM. PROVIDE CORRECTION. NEC 210.8 | | | 3. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | | FBC EC C405.1, R404.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-06-29 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-06-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-06-29 |
Time |
12:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-07-24 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-07-24 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-06-27 |
Time |
14:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2018-07-24 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-07-24 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-07-24 |
Time |
13:22 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |