| Plan Review Stops For Permit 18061260 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-01-24 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-01-24 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-01-24 |
Time |
13:15 |
Sent To |
|
|
| Notes |
| 2019-01-24 13:25:23 | PROVISO: | | | SUBMITTAL FOR METAL STAIR, HANDRAIL AND GUARDS TO BE | | | PROVIDED . | | | | | | ASCE 7-10 SECTION 4.5.1 LOADS ON HANDRAIL AND GUARDRAIL | | | SYSTEMS. ALL HANDRAIL AND GUARDRAIL SYSTEMS SHALL BE | | | DESIGNED TO ESIST A SINGLE CONCENTRATED LOAD OF 200 LB | | | APPLIED IN ANY DIRECTION AT ANY POINT ON THE HANDRAIL | | | OR TOP RAIL AND TO TRANSFER THIS LOAD THROUGH THE | | | SUPPORTS TO THE STRUCTURE. FURTHER, ALL HANDRAILS AND | | | GUARDRAIL SYSTEMS SHALL BE DESIGNED TO RESIST A LOAD OF | | | 50 POUND-FORCE PER LINEAR FOOT APPLIED IN ANY DIRECTION | | | ALONG THE HANDRAIL OR TOP RAIL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-11-09 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-11-09 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-11-09 |
Time |
15:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-08-10 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-08-10 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-08-10 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2018-08-10 14:15:06 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 18061260 | | | REVIEWED: AUGUST 10, 2018 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. [FBC R401.4]PROVIDE SOIL REPORT TO SHOW BEARING | | | CAPACITY AND FOUNDATION RECOMMENDATION FOR 2 STORY | | | STRUCTURE. | | | | | | 2. [FBC ENERGY TABLE R402A]FLOOR BETWEEN GARAGE SHOULD | | | BE R13. PLEASE ADD TO ENERGY FORM R402-2017. | | | | | | 3. RE-PRINT 2 COPIES OF FL5684-R8. THE COPIES PROVIDED | | | AREN?T LEDGIBLE AFTER THE FIRST COUPLE OF PAGES. | | | | | | 4. [FBC R905.2.2] [FBC R905.1.1]FOR ROOF SLOPES FROM | | | TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL (2:12) AND | | | LESS THAN FOUR UNITS VERTICAL IN 12 UNITS HORIZONTAL | | | (4:12), DOUBLE UNDERLAYMENT APPLICATION IS REQUIRED. | | | | | | 5. [R302.6]GARAGE CEILING TO HAVE TYPE NOT LESS THAT | | | 5/8? TYPE X OR EQUIVELANT DRYWALL WHEN HABITABLE SPACE | | | IS PROVIDED ABOVE. | | | | | | 6. [FBC R506.2.3] A 6-MIL (0.006 INCH; 152 ?M) | | | POLYETHYLENE OR APPROVED VAPOR RETARDER WITH JOINTS | | | LAPPED NOT LESS THAN 6 INCHES. | | | | | | PROVISO: | | | PROVIDE ROOF TRUSS ENGINEERING SUBMITTAL PRIOR TO | | | INSTALLATION. | | | PROVIDE STAIR AND RAIL ENGINEERING SUBMITTAL PRIOR TO | | | INSTALLATION. | | | | | | NOTE: | | | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | | OF MATERIALS REQUESTED. | | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-02-03 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-02-03 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-02-03 |
Time |
11:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-10-26 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2018-10-26 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2018-10-26 |
Time |
09:13 |
Sent To |
|
|
| Notes |
| 2018-10-26 11:46:11 | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1.OK | | | 2.OK | | | 3. OK | | | 4.OK | | | 5.OK | | | 6.PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF SERVICE | | | EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, WIRE AND | | | BREAKER SIZES FOR SERVICE AND FEED TO ANY SUB-PANEL(S). | | | SHOW GEC SIZE AND SYSTEM, NEC 215.5, 230, 250.50, | | | 250.94, 408.30; FBC RE E3706.1, E3608.1, E3609.3; WPB | | | FBC 107.2.1. | | | 7.OK | | | 8.OK | | | 9. | | | FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | | STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR | | | MAIN BREAKER AT THE PANEL FOR PANEL A. NEC 225.31, | | | 225.32 | | | 10. PROVIDE DETAIL OF MAINS, GROUPED IN ONE LOCATION. | | | NEC 230.72 | | | 11.OK | | | 12.OK | | | 13.OK | | | 14.OK | | | 15.OK | | | 16.FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | | STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR | | | MAIN BREAKER AT THE PANEL FOR PANEL A. NEC 225.31, | | | 225.32 | | | 17.PARALLEL PATH IN SERVICE RACEWAYS 250.6 | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER,CHIEF ELECTRICAL INSPECTOR | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-07-30 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2018-07-30 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2018-07-30 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2018-07-30 13:19:54 | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1.ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. PROVIDE | | | CORRECTION. SOME AREAS REQUIRE AFCI AND GFCI | | | PROTECTION. NEC 210.8, 210.12; FBC RE E3902 | | | 2.PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10 | | | PROVIDE AIC RATING OF SERVICE DISCONNECT AND PANEL. NEC | | | 110.3, 110.9 | | | 3. PROVIDE GFCI PROTECTION FOR DISPOSAL RECEPTACLE | | | OUTLET WHEN INSTALLED WITHIN 6 FEET OF SINK. NEC | | | 210.8(A)(7); FBC RE E3902.73. | | | 4.A GROUNDING ELECTRODE SYSTEM IS REQUIRED TO BE | | | ESTABLISHED AT EACH SEPARATE BUILDING OR STRUCTURE AND | | | CONNECTED TOGETHER. PROVIDE DETAILS ON PLAN OF | | | GROUNDING ELECTRODE SYSTEM AND WIRING. NEC 250.32; FBC | | | RE E3607.3 | | | 5.PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS. NEC 220; FBC RE E3602.2 | | | 6.PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF SERVICE | | | EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, WIRE AND | | | BREAKER SIZES FOR SERVICE AND FEED TO ANY SUB-PANEL(S). | | | SHOW GEC SIZE AND SYSTEM, SHOW INTERSYSTEM BONDING | | | TERMINATION POINT. NEC 215.5, 230, 250.50, 250.94, | | | 408.30; FBC RE E3706.1, E3608.1, E3609.3; WPB FBC | | | 107.2.1. | | | 7. PROVIDE TAMPER RESISTANT RECEPTACLES. NEC 406.12 | | | 8.PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. SMALL APPLIANCE CIRCUITS SHOULD BE | | | CALCULATED AT 1500 VOLT AMPS EACH.NEC 215.2, 220, | | | 408.30; FBC RE E3602.2 | | | 9.A BUILDING OR OTHER STRUCTURE THAT IS SERVED BY A | | | BRANCH CIRCUIT OR FEEDER ON THE LOAD SIDE OF A SERVICE | | | DISCONNECTING MEANS SHALL BE SUPPLIED BY ONLY ONE | | | FEEDER OR BRANCH CIRCUIT. NEC 225.30 | | | PROVIDE GROUNDING ELECTRODE SYSTEM AS REQUIRED FOR A | | | BUILDING OR STRUCTURE SUPPLIED BY A FEEDER OR BRANCH | | | CIRCUIT. NEC 250.32; FBC RE3607.3 | | | FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | | STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR | | | MAIN BREAKER AT THE PANEL FOR PANEL A. NEC 225.31, | | | 225.32 | | | 10. PROVIDE DETAIL OF MAINS, GROUPED IN ONE LOCATION. | | | NEC 230.72 | | | 11. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE. | | | FBC EC R404.1 | | | 12. A MINIMUM OF ONE 20 AMPERE BRANCH CIRCUIT SHALL BE | | | PROVIDED TO SUPPLY BATHROOM RECEPTACLE OUTLET(S). SUCH | | | CIRCUITS SHALL HAVE NO OTHER OUTLETS. PROVIDE | | | CORRECTION. NEC 210.11(C)(3) , FBC RE E3703.4 | | | 13.W/H CIRCUT HAS 60A BKR ON #10 WIRE.PROVIDE | | | CORRECTION. NEC 310.15(B) (16). | | | 14. PROVIDE LOCATION OF PANEL ON PLAN.WPB FBC 107.2.1 | | | 15. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | | 210.8(D); FBC RE E3902.10 | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER,CHIEF ELECTRICAL INSPECTOR | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-02-25 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-02-25 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-02-25 |
Time |
10:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-02-19 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2019-02-19 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2019-01-15 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2019-02-16 10:00:31 | 2/16 IN HM OFFICE | | | | | 2019-01-16 15:52:52 | R15 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-12-02 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-12-02 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-10-02 |
Time |
10:19 |
Sent To |
|
|
| Notes |
| 2018-10-11 16:24:38 | R12 | | 2018-10-04 10:19:54 | LIBRARY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-08-22 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-08-22 |
Time |
19:55 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-06-26 |
Time |
14:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2019-02-25 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-02-25 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-02-25 |
Time |
10:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2018-08-10 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-08-10 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-08-10 |
Time |
14:23 |
Sent To |
|
|
| Notes |
| 2018-08-10 14:23:58 | [FBC 109] PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE | | | OFFICE. CALL (561) 233-5025. UPON APPROVAL, YOU MAY | | | CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR | | | REVIEW. PLEASE RETURNED STAMPED AND WITH A COPY OF THE | | | RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE | | | OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO | | | V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN | | | AIRE.PDF |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2019-02-19 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2019-02-19 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2019-02-19 |
Time |
15:50 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2018-10-29 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-10-29 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-10-29 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2018-10-29 11:26:31 | PLAN DENIED | | | REFER TO SECTION R403.7 HEATING AND COOLING EQUIPMENT. | | | 2017 FLORIDA ENERGY CODE ( PROVIDE ENERGY CALCULATIONS) | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-08-04 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-08-04 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-08-04 |
Time |
08:59 |
Sent To |
|
|
| Notes |
| 2018-08-04 09:53:32 | PLAN DENIED | | | 1) REFER TO SECTION M1401.3 EQUIPMENT AND APPLIANCE | | | SIZING | | | 2017 RESIDENTIAL CODE | | | 2) MISSING DUCT SIZE ON BATHROOM SUPPLY DUCT. SECTION | | | 107 FBC. | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2019-01-29 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-01-29 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-01-29 |
Time |
08:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-11-06 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2018-11-06 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-11-06 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2018-11-06 15:16:39 | PLUMBING COMMENTS: APPROVED | | | PROVISO | | | A SEPARATE PERMIT IS REQUIRED FOR THE BACKFLOW | | | PREVENTION DEVICE. BACKFLOW PREVENTER REQUIRED PER THE | | | CITY OF WEST PALM BEACH ORD #2853-95. PLEASE CONTACT | | | CITY OF WPB UTILITIES AT 561-822-2240 FOR FURTHER | | | DIRECTIONS. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | EMAIL: [email protected] | | | PHONE: 561-805-6715 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-08-22 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-08-22 |
Time |
19:54 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-08-22 |
Time |
19:54 |
Sent To |
|
|
| Notes |
| 2018-08-22 19:55:22 | 08/22/2018 1ST PLUMBING REVIEW **DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. ISOMETRIC SHOWS KITCHEN SINK TIED TO A BATHROOM | | | GROUP, IT SHALL RUN DOWNSTREAM OF THE BATHROOM GROUP. | | | WPB AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON | | | CONSTRUCTION DOCUMENTS. | | | 2. RELIEF LINE SHALL DUMP INTO PAN DRAIN AND PAN DRAIN | | | SHALL TERMINATE OUTSIDE. 2017 FBC R 2801.6.2 | | | 3. THE SHOWER PAN IS NOT RECEDED IT WILL REQUIRE LINING | | | FBC R 2709.2 LINING REQUIRED. | | | | | | NOTE: SHOWER PAN MUST HAVE A SLOPED MORTAR BED THAT IS | | | PRE-PITCHED BENEATH PRIOR TO LINER INSTALLATION OF 1/4" | | | IN PER FOOT TOWARD THE DRAIN, MUST HAVE DAM CORNER, | | | BACKING AROUND THE PERIMETER AND BEFORE FINAL MORTAR | | | APPLICATION PLACE SOME PEA GRAVEL OVER WEEP HOLES SO | | | THE MORTAR DOES NOT COVER THEM PER MANUFACTURES | | | SPECIFICATIONS. | | | | | | 4. THE WATER HEATER ON YOUR FLORIDA ENERGY EFFICIENCY | | | FORM R405-2017 IS SHOWING THE E.F AS .92. AS OF APRIL | | | 16, 2015, ALL RESIDENTIAL WATER HEATERS ARE REQUIRED TO | | | BE A MIN .95 E.F UP TO 55 GALLONS. THIS IS DEFINED IN | | | THE CODE OF FEDERAL REGULATION (CFR) 75 FR 2012. NEACA | | | HOT WATER REGULATION 2015 AND IT SHOULD BE AT EF 0.95, | | | PLEASE VISIT HTTP://WWW.CASHACME.COM/RESOURCES/NAECA-20 | | | 15-REGULATIONS/ FOR FURTHER DETAILS. | | | | | | 5. BACKFLOW PREVENTER REQUIRED PER THE CITY OF WEST | | | PALM BEACH ORD #2853-95. PLEASE CONTACT CITY OF WPB | | | UTILITIES AT 561-822-2240 FOR FURTHER DIRECTIONS. A | | | BACKFLOW DEVICE MAY BE REQUIRED BY THE CITY OF WEST | | | PALM BEACH UTILITY DEPARTMENT CROSS CONNECTION MANUAL. | | | A PERMIT REQUIRED BY A LICENSED CONTRACTOR AND | | | APPLICATION ALONG WITH CERTIFICATION BY UTILITIES WITH | | | A FINAL INSPECTION WILL BE REQUIRED. CALL THE UTILITY | | | DEPARTMENT FOR INFORMATION AT 561 822-2240. | | | | | | HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PUBLI | | | CATIONS/BACKFLOW-CROSS-CONNECTION-CONTROL-MANUAL | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2018-11-09 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-11-09 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-11-09 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2018-11-09 15:13:59 | PRODUCT APPROVAL-OK FOR SHINGLE ROOF | | | NOTE ADDED TO PLANS FOR DOUBLE LAYER UNDERLAYMENT FOR | | | 3:12 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-08-10 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-08-10 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-08-10 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2018-08-10 14:25:21 | DOUBLE LAYER UNDERLAYMENT REQUIRED FOR 3:12 | | | SHINGLE TILE PRODUCT APPROVAL OK. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2019-02-14 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2019-02-14 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2019-02-12 |
Time |
11:06 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-11-30 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-11-30 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-11-30 |
Time |
16:09 |
Sent To |
PC |
|
| Notes |
| 2018-11-30 16:27:05 | ZONING PASSED WITH PROVISO: KITCHEN AND 220 CONNECTIONS | | | TO BE REMOVED. THIS IS A BEDROOM ADDITION NOT AN | | | APARTMENT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-07-12 |
|
|
Cont ID |
|
| Sent By |
MC |
Date |
2018-07-12 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-07-12 |
Time |
12:56 |
Sent To |
|
|
| Notes |
| 2018-07-12 13:43:40 | ZONING REVIEW FAILED, DUE TO THE FOLLOWING: | | | | | | 1) GARAGE APARTMENT IS NOT PERMITTED. WHILE THE ZONING | | | DISTRICT ALLOWS FOR GARAGE APARTMENTS, THIS PROPERTY | | | DOES NOT MEET THE MINIMUM LOT AREA OF 6,000 SQ. FT. | | | REQUIRED TO ALLOW A GARAGE APARTMENT. | | | 2) INDICATE ON PLAN DIMENSION FROM PRINCIPAL STRUCTURE | | | TO GARAGE. MUST BE AT LEAST 6 FEET. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ | | | ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: 561-822-1442 | | | E-MAIL: [email protected] |
|
|