| Plan Review Stops For Permit 18061156 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-08-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-25 |
Time |
12:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-25 |
Time |
12:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2018-07-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-07-08 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-08 |
Time |
11:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-08-11 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-08-11 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-08-11 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2018-08-11 11:36:40 | THIS PLAN HAS BEEN PASSED PROVISIONALLY: | | | | | | SUBMIT ACCURATE PANEL SCHEDULE SHOWING OCP AND PROPER | | | WATTAGE BEFORE FINAL. | | | | | | PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4; WPB FBC | | | 107.3.5; FBC RE E3706.2, E3902 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-07-11 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-07-11 |
Time |
06:51 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-07-11 |
Time |
06:41 |
Sent To |
|
|
| Notes |
| 2018-07-11 06:51:41 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE CLEAR LOCATION OF ELECTRICAL PANEL. PANEL | | | APPEARS TO BE IN CLOSET ALONG WITH W/H AND AHU. PANEL | | | APPEARS TO NOT HAVE THE REQUIRED WORKING CLEARANCE TO | | | MEET NEC 110.26A1 & A2. | | | | | | 2. PROVIDE RISER DIAGRAM OF EXISTING SERVICE. | | | OVERCURRENT PROTECTION, WIRE AND CONDUIT SIZE FOR | | | EXISTING PANEL IN UNIT. NEC 215.5; WPB FBC 107.2.1 | | | VOLTAGE AT TRUMP TOWER IS BELIEVED TO BE 208V NOT 240V, | | | WHICH WOULD CHANGE THE LOAD CALCULATION FROM 132.45AMPS | | | TO 153AMPS | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WPB | | | [email protected] | | | CELL: 561-657-1653 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-06-27 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-06-27 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-06-27 |
Time |
10:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-08-28 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-08-28 |
Time |
05:21 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-08-08 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2018-08-25 12:04:30 | 8/25 TO TL DESK | | | | | 2018-08-09 15:29:06 | RESUB ROUTED TO FGIAQUINTO |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-07-31 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-07-31 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-06-25 |
Time |
13:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2018-07-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-07-02 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-07-02 |
Time |
14:39 |
Sent To |
|
|
| Notes |
| 2018-07-02 14:43:43 | SEPARATE PERMIT FOR MECHANICAL- SEE NOTE ON SHEET 01. | | | CCOLE-7/2/18 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-08-28 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-08-28 |
Time |
05:21 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-08-28 |
Time |
05:02 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-07-31 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-07-31 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-07-31 |
Time |
13:10 |
Sent To |
I |
|
| Notes |
| 2018-07-31 14:36:30 | 1) THE MINIMUM SIZE OF THE HORIZONTAL AND VERTICAL | | | DRAIN FOR THE WASHING MACHINE SHALL BE A MINIMUM OF 3 | | | INCHES PER THE 2017 FBC-PLUMBING SEC.406.2. | | | 2) NEW TUB & SHOWER VALVES SHALL COMPLY WITH 2017 | | | FBC-PLUMBING SEC. 424.3. | | | | | | NOTE: THIS STRUCTURE WAS BUILT IN 1986 SO FAIR HOUSING | | | DOES NOT APPLY. | | | | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|