Plan Review Details - Permit 18061155
Plan Review Stops For Permit 18061155
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-08-25 Cont ID  
Sent By shill Date 2018-08-25 Time 14:14 Rev Time 0.00
Received By shill Date 2018-08-25 Time 14:14 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-07-08 Cont ID  
Sent By shill Date 2018-07-08 Time 11:42 Rev Time 0.00
Received By shill Date 2018-07-08 Time 11:42 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-08-11 Cont ID  
Sent By fgiaquin Date 2018-08-11 Time 11:17 Rev Time 0.00
Received By fgiaquin Date 2018-08-11 Time 11:06 Sent To  
Notes
2018-08-11 11:17:30THIS PLAN HAS PASSED PROVISIONALLY:
  
 SUBMIT ACCURATE PANEL SCHEDULE WITH OCP LABELED AND
 PROPER WATTAGES BEFORE FINAL INSPECTION.
  
 PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED
 CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS,
 AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY
 WITH CODE. NEC 210.8, 210.12, 215.5, 408.4; WPB FBC
 107.3.5; FBC RE E3706.2, E3902

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-07-11 Cont ID  
Sent By fgiaquin Date 2018-07-11 Time 06:20 Rev Time 0.00
Received By fgiaquin Date 2018-07-11 Time 05:52 Sent To  
Notes
2018-07-11 06:19:28ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE CLEAR LOCATION OF ELECTRICAL PANEL. PANEL
 APPEARS TO BE IN CLOSET ALONG WITH W/H AND AHU. PANEL
 APPEARS TO NOT HAVE THE REQUIRED WORKING CLEARANCE TO
 MEET NEC 110.26A1 & A2.
  
 2. PROVIDE RISER DIAGRAM OF EXISTING SERVICE.
 OVERCURRENT PROTECTION, WIRE AND CONDUIT SIZE FOR
 EXISTING PANEL IN UNIT. NEC 215.5; WPB FBC 107.2.1
 VOLTAGE AT TRUMP TOWER IS BELIEVED TO BE 208V NOT 240V,
 WHICH WOULD CHANGE THE LOAD CALCULATION FROM 132.45AMPS
 TO 153AMPS
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2017 6TH ED.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WPB
 [email protected]
 CELL: 561-657-1653
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2018-06-27 Cont ID  
Sent By scaldero Date 2018-06-27 Time 10:46 Rev Time 0.00
Received By scaldero Date 2018-06-27 Time 10:46 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-08-28 Cont ID  
Sent By tklarge Date 2018-08-28 Time 05:38 Rev Time 0.00
Received By tklarge Date 2018-08-08 Time 15:32 Sent To  
Notes
2018-08-25 14:14:27TO TL DESK
  
2018-08-09 15:32:55RESUB ROUTED TO FGIAQUINTO

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-07-31 Cont ID  
Sent By gjohnson Date 2018-07-31 Time 10:44 Rev Time 0.00
Received By gjohnson Date 2018-06-25 Time 13:59 Sent To  
Notes
2018-06-26 13:59:53B10

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2018-06-29 Cont ID  
Sent By ccole Date 2018-06-29 Time 16:44 Rev Time 0.00
Received By ccole Date 2018-06-29 Time 16:43 Sent To  
Notes
2018-06-29 16:45:09SHEET 01 CALLS OUT SEPARATE PERMIT AND PLANS FOR
 MECHANICAL
 CCOLE- 6/29/18

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-08-28 Cont ID  
Sent By tklarge Date 2018-08-28 Time 05:37 Rev Time 0.00
Received By tklarge Date 2018-08-28 Time 05:24 Sent To I
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-07-31 Cont ID  
Sent By gjohnson Date 2018-07-31 Time 10:40 Rev Time 0.00
Received By gjohnson Date 2018-07-31 Time 10:24 Sent To  
Notes
2018-07-31 10:43:521ST REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. PROVIDE SANITARY ISOMETRIC FOR GUEST BATHROOM FOR
 THE TOILET AND VANITY ARE BEING RELOCATED. PER WPB
 AMEND TO FBC 107.3.5.1.3(13)
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  