| Plan Review Stops For Permit 18061155 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-08-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-25 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-25 |
Time |
14:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2018-07-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-07-08 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-08 |
Time |
11:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-08-11 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-08-11 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-08-11 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2018-08-11 11:17:30 | THIS PLAN HAS PASSED PROVISIONALLY: | | | | | | SUBMIT ACCURATE PANEL SCHEDULE WITH OCP LABELED AND | | | PROPER WATTAGES BEFORE FINAL INSPECTION. | | | | | | PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4; WPB FBC | | | 107.3.5; FBC RE E3706.2, E3902 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-07-11 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-07-11 |
Time |
06:20 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-07-11 |
Time |
05:52 |
Sent To |
|
|
| Notes |
| 2018-07-11 06:19:28 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE CLEAR LOCATION OF ELECTRICAL PANEL. PANEL | | | APPEARS TO BE IN CLOSET ALONG WITH W/H AND AHU. PANEL | | | APPEARS TO NOT HAVE THE REQUIRED WORKING CLEARANCE TO | | | MEET NEC 110.26A1 & A2. | | | | | | 2. PROVIDE RISER DIAGRAM OF EXISTING SERVICE. | | | OVERCURRENT PROTECTION, WIRE AND CONDUIT SIZE FOR | | | EXISTING PANEL IN UNIT. NEC 215.5; WPB FBC 107.2.1 | | | VOLTAGE AT TRUMP TOWER IS BELIEVED TO BE 208V NOT 240V, | | | WHICH WOULD CHANGE THE LOAD CALCULATION FROM 132.45AMPS | | | TO 153AMPS | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WPB | | | [email protected] | | | CELL: 561-657-1653 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-06-27 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-06-27 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-06-27 |
Time |
10:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-08-28 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-08-28 |
Time |
05:38 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-08-08 |
Time |
15:32 |
Sent To |
|
|
| Notes |
| 2018-08-25 14:14:27 | TO TL DESK | | | | | 2018-08-09 15:32:55 | RESUB ROUTED TO FGIAQUINTO |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-07-31 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-07-31 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-06-25 |
Time |
13:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2018-06-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-06-29 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-06-29 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2018-06-29 16:45:09 | SHEET 01 CALLS OUT SEPARATE PERMIT AND PLANS FOR | | | MECHANICAL | | | CCOLE- 6/29/18 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-08-28 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-08-28 |
Time |
05:37 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-08-28 |
Time |
05:24 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-07-31 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-07-31 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-07-31 |
Time |
10:24 |
Sent To |
|
|
| Notes |
| 2018-07-31 10:43:52 | 1ST REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PROVIDE SANITARY ISOMETRIC FOR GUEST BATHROOM FOR | | | THE TOILET AND VANITY ARE BEING RELOCATED. PER WPB | | | AMEND TO FBC 107.3.5.1.3(13) | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|