Plan Review Details - Permit 18061145
| Plan Review Stops For Permit 18061145 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-10-30 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-10-30 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-10-30 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2018-10-30 15:00:14 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 18061145 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. AN ADDRESS WILL NEED TO BE PROVIDED FOR LOT 42. | | | FOR ADDRESSING, PLEASE CONTACT (PREFERABLY VIA EMAIL): | | | MICHAEL ORIO | | | GIS SUPPORT SPECIALIST | | | [email protected] | | | CITY OF WEST PALM BEACH | | | INFORMATION TECHNOLOGY DEPARTMENT | | | 401 CLEMATIS STREET, WEST PALM BEACH, FLORIDA 33401 | | | P: 561.494.1080 | | | | | | 1-2. PROVIDE DOCUMENTATION THAT THE PROPERTY HAS BEEN | | | SUB DIVIDED WITH THE PALM BEACH COUNTY PROPERTY | | | APPRAISER?S OFFICE. | | | ALSO, PROVIDE THE NEW ADDRESS AND PUT IT ON THE | | | DRAWINGS IF CHANGED FROM 1113 22ND. | | | | | | 2. OK | | | | | | 3. OK | | | | | | 4. [FBC R401.3]PROVIDE SITE DRAINAGE PLAN. ALSO PROVIDE | | | THE LOWEST FLOOR ELEVATION ON RELEVANT DRAWINGS. THIS | | | SHOULD BE USED IN CONJUCTION WITH DRAINAGE PLAN TO SHOW | | | GRADE 4" LOWER THAN LOWEST FLOOR LEVEL AND HOW DRAINAGE | | | MEETS REQUIREMENTS IN [FBC R401.3] | | | | | | 4-2. SITE DRAINAGE PROVIDED DOESN?T KEEP THE DRAINAGE | | | WITHIN THE SITE. | | | [FBC R403.1.7.3] FOUNDATION ELEVATION. | | | ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION | | | SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER | | | AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED | | | DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2 | | | PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO | | | THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN | | | BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF | | | DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT | | | ALL LOCATIONS ON THE SITE. | | | | | | 5. OK | | | | | | 6. OK | | | | | | 7. [FBC ENERGY R401.2]PROVIDE ENERGY CALCULATIONS TO | | | MEET REQUIREMENTS IN R401.2 RESIDENTIAL ENERGY CODE. | | | CHOOSE METHOD IN R401.2 AND SUPPLY DOCUMENTATION. | | | | | | 7-2 ENERGY CODE COMPLIANCE NEEDS TO BE MET FOR BUILDING | | | AS WELL AS MECHANICAL. IF PERFORMANCE BASED ENERGY | | | CALCULATIONS AREN?T PROVIDED THAN INDICATE THE METHOD | | | USED TO COMPLY FOR ALL BUILDING ELEMENTS AS APPLICABLE | | | TO [FBC ENERGY R401.2] | | | | | | 8. OK | | | | | | 9. OK | | | | | | 10. PRODUCT APPROVALS WILL BE A PROVISO TO THE PERMIT. | | | | | | 11. PRODUCT APPROVALS FOR ROOFING TO BE SUBMITTED WITH | | | THE SUB-PERMIT FOR ROOFING. | | | | | | 12. OK | | | | | | 13. OK | | | | | | 14. OK | | | | | | PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | | | | NOTE: | | | ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | | OF MATERIALS REQUESTED. | | | WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-07-20 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-07-20 |
Time |
07:56 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-07-25 |
Time |
14:36 |
Sent To |
|
|
| Notes |
| 2018-07-20 07:57:17 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 18061145 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. AN ADDRESS WILL NEED TO BE PROVIDED FOR LOT 42. | | | FOR ADDRESSING, PLEASE CONTACT (PREFERABLY VIA EMAIL): | | | MICHAEL ORIO | | | GIS SUPPORT SPECIALIST | | | [email protected] | | | CITY OF WEST PALM BEACH | | | INFORMATION TECHNOLOGY DEPARTMENT | | | 401 CLEMATIS STREET, WEST PALM BEACH, FLORIDA 33401 | | | P: 561.494.1080 | | | | | | 2. IS THIS PROJECT BEING BUILT WITH FEDERAL FUNDS? | | | PLEASE VERIFY THAT ADDITIONAL ADA REQUIREMENTS DON'T | | | APPLY IF FEDERAL FUNDING IS BEING USED FOR THIS | | | PROJECT. | | | | | | 3. [FBC R401.4]PROVIDE SOIL REPORT TO SHOW BEARING | | | CAPACITY. | | | | | | 4. [FBC R401.3]PROVIDE SITE DRAINAGE PLAN. ALSO PROVIDE | | | THE LOWEST FLOOR ELEVATION ON RELEVANT DRAWINGS. THIS | | | SHOULD BE USED IN CONJUCTION WITH DRAINAGE PLAN TO SHOW | | | GRADE 4" LOWER THAN LOWEST FLOOR LEVEL AND HOW DRAINAGE | | | MEETS REQUIREMENTS IN [FBC R401.3] | | | | | | 5. [FBC 107.3.5.3] PROVIDE SEDIMENT CONTROL PLAN TO | | | KEEP CONSTRUCTION DEBRIS FROM ENTERING ADJACENT | | | PROPERTIES AND STORM DRAINS. | | | | | | 6. [FBC 107.3.5.3] PLEASE ADD PROJECT DESIGN DATA: | | | ZONING, OCCUPANCY, CONSTRUCTION TYPE AND MEAN ROOF | | | HEIGHT(MRH). | | | | | | 7. [FBC ENERGY R401.2]PROVIDE ENERGY CALCULATIONS TO | | | MEET REQUIREMENTS IN R401.2 RESIDENTIAL ENERGY CODE. | | | CHOOSE METHOD IN R401.2 AND SUPPLY DOCUMENTATION. | | | | | | 8. [FBC R302.10]PROVIDE CUT SHEET FOR ICYNENE(SEE | | | ICC-ES REPORT OR EQUAL) WITH THE TYPE SELECTED TO | | | ESTABLISH THICKNESS NEEDED TO MEET REQUIRED R-VALUE, | | | FLAME SPREAD INDEX AND SMOKE DEVELOPED INDEX. | | | IF THERE IS MECHANICAL EQUIPMENT IN THE SPACE THAN IT | | | REQUIRES IGNITION BARRIER. | | | | | | 9. [FBC R806.5]DETAIL 5/S-3 SHOWS CONTINOUS VENT AT | | | SOFFIT. WITH ICYNENE SPRAYED TO UNDERSIDE OF ROOF DECK. | | | THE ATTIC SPACE NEEDS TO BE CONTAINED WITHIN THE | | | BUILDING ENVELOPE. PLEASE INDICATE IF THIS IS AN | | | UNVENTED ATTIC OR EXPLAIN HOW THE VENTS WON'T BREAK THE | | | THERMAL ENVELOPE. | | | | | | 10. [FBC 107.2.1.2]PROVIDE PRODUCT APPROVALS FOR | | | WINDOWS, WINDOW MULL, DOORS, TRANSOMS, SLIDERS AND | | | SOLAR TUBES, OR INDICATE THAT YOU WOULD LIKE THEM | | | DEFFERED. THE DEFERRED SUBMITTAL DOCUMENTS SHALL BE | | | APPROVED BY THE BUILDING OFFICIAL PRIOR TO | | | INSTALLATION. | | | | | | 11. [FBC 107.2.1.2]PROVIDE PRODUCT APPROVALS FOR | | | ROOFING, OR INDICATE THAT YOU WOULD LIKE THEM DEFFERED. | | | THE DEFERRED SUBMITTAL DOCUMENTS SHALL BE APPROVED BY | | | THE BUILDING OFFICIAL PRIOR TO INSTALLATION. | | | | | | 12. [FBC R703.4]PROVIDE NOTE FOR TYPE OF WINDOW/DOOR | | | FLASHING TO BE USED TO MEET REQUIREMNETS OF [FBC | | | R703.4]. | | | | | | 13. [FBC R608.8]PROVIDE LINTEL SCHEDULE TO SHOW | | | BEARING. PROVIDE LINTEL DOCUMENTATION FOR SAFE LOADING. | | | | | | 14.[FBC R402.2]DETAIL 5/S3 SAYS CONCRETE COMPRESSIVE | | | STRENGTH IS 300. PLEASE UPDATE TO 3000 IF THAT WAS THE | | | INTENT. ALSO, ADD COMPRESSIVE STRENGTH FOR GROUT. | | | | | | PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | | | | NOTE: | | | ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | | OF MATERIALS REQUESTED. | | | WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-09-22 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-09-22 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-09-22 |
Time |
13:38 |
Sent To |
|
|
| Notes |
| 2018-09-22 13:38:33 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS. LOAD CALCULATION PROVIDED HAS SOME ITEMS NOT | | | INCLUDED AND DEMAND FACTOR APPLIED INCORRECTLY. SEE | | | FORMAT IN FBC RESIDENTIAL. NEC 220; FBC RE E3602.2 | | | (LOAD CALCULATION NOT CORRECT. A LAUNDRY CIRCUIT MUST | | | BE INCLUDED AT 1500 VA, AND THIS IS SEPARATE FROM THE | | | DRYER WHICH MUST BE CALCULATED AT A MINIMUM OF 5000 VA, | | | BREAKER SHOWN FOR DRYER IS 50 AMP WHICH IS MUCH MORE | | | THAN 4500 VA. NEC 220.52 AND 220.54) | | | 2. PROVIDE ACCURATE PANEL SCHEDULE INDICATING ALL | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. WATER HEATER IS NOT SHOWN. NEC 210.8, | | | 210.12, 210.19, 210.20, 215.5, 408.4; WPB FBC 107.3.5; | | | FBC RE E3706.2, E3902 (WATER HEATER NOT SHOWN IN PANEL | | | SCHEDULE, AFCI PROTECTION NOT SHOWN CORRECTLY.) | | | 3. AFCI PROTECTION SHOWN IN NOT CODE COMPLIANT. ALL | | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | | SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND | | | POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH | | | AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC | | | 210.8, 210.12; FBC RE E3902.16 (NOT CORRECTED, NOTE | | | STATES THAT RECEPTACLES SHALL BE AFCI PROTECTED WHICH | | | IS NOT CODE COMPLIANT.) | | | 4. CORRECTED. | | | 5. CORRECTED. | | | 6. TRANSFER SWITCH REMOVED. | | | 7. CORRECTED. | | | 8. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10; FBC RE E3603.3 (NOT PROVIDED) | | | 9. CORRECTED. | | | 10. PROVIDE ACCURATE RISER DIAGRAM. THE EQUIPMENT | | | GROUNDING CONDUCTOR (EGC) SHOULD NOT BE INCLUDED IN THE | | | CONDUIT FROM THE METER TO THE MANUAL TRANSFER SWITCH. | | | THE EGC FROM THE MANUAL TRANSFER SWITCH TO THE INTERIOR | | | PANEL IS NOT SIZED PROPERLY. INTERIOR PANEL STATES THAT | | | IS HAS A 125 AMP MAIN, AND BELOW THAT STATES THAT IT | | | HAS A 150 AMP MAIN. CORRECT DISCREPANCY. NEC 215.5, | | | 250.6, 250.122; WPB FBC 107.2.1; FBC RE E3704.6, | | | 3607.3.1 (RISER STILL NOT CORRECT. RISER DIAGRAM SHOWS | | | A FEED FROM THE METER TO THE INTERIOR PANEL WHICH IS | | | LOCATED IN THE DINING ROOM. CONDUCTORS THAT ARE NOT | | | PROTECTED BY A MAIN BREAKER OR DISCONNECT ARE NOT | | | PERMITTED TO RUN THROUGH THE HOUSE IN THIS FASHION. | | | PROVIDE EITHER A MAIN ON THE OUTSIDE OF THE HOME, OR | | | INSTALL THE CONDUCTORS UNDER THE SLAB. IF CONDUCTORS | | | ARE INSTALLED UNDER THE SLAB, THEN THERE SHOULD NOT BE | | | AN EQUIPMENT GROUNDING CONDUCTOR IN THIS CONDUIT. IF | | | THERE IS A MAIN BREAKER, THAN THE EGC IS NOT SIZED | | | PROPERLY. PROVIDE CORRECTIONS. NEC 230.70, 250.6; FBC | | | RE E3601.6) | | | 11. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | | SERVICE. SHOW ON PLAN. NEC 250.94; FBC RE E3609.3 (NOT | | | SHOWN ON RISER DIAGRAM) | | | 12. RISER DIAGRAM SHOWS A SINGLE GROUND ROD AS A | | | SUPPLEMENTAL GROUNDING ELECTRODE. THIS SUPPLEMENTAL | | | GROUNDING ELECTRODE NEEDS TO BE AUGMENTED BY AN | | | ADDITIONAL ELECTRODE AT LEAST 6 FEET AWAY OR PROVIDE | | | EVIDENCE OF RESISTANCE TO GROUND OF 25 OHMS OR LESS. | | | NEC 250.53(A)(2); FBC RE E3608.4 (NOT CORRECTED, ALSO | | | SIZE OF GROUNDING ELECTRODE CONDUCTOR IS NOT CODE | | | COMPLIANT. PROVIDE CORRECTION. NEC 250.66) | | | 13. CORRECTED. | | | 14. CORRECTED. | | | 15. CORRECTED. | | | | | | NEW COMMENT: | | | | | | 16. PROVIDE CARBON MONOXIDE ALARMS WITHIN 10 FEET OF | | | EACH ROOM USED FOR SLEEPING PURPOSES. FBC RE R315.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-07-20 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-07-20 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-07-20 |
Time |
08:28 |
Sent To |
|
|
| Notes |
| 2018-07-20 09:52:19 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS. LOAD CALCULATION PROVIDED HAS SOME ITEMS NOT | | | INCLUDED AND DEMAND FACTOR APPLIED INCORRECTLY. SEE | | | FORMAT IN FBC RESIDENTIAL. NEC 220; FBC RE E3602.2 | | | 2. PROVIDE ACCURATE PANEL SCHEDULE INDICATING ALL | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. WATER HEATER IS NOT SHOWN. NEC 210.8, | | | 210.12, 210.19, 210.20, 215.5, 408.4; WPB FBC 107.3.5; | | | FBC RE E3706.2, E3902 | | | 3. AFCI PROTECTION SHOWN IN NOT CODE COMPLIANT. ALL | | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | | SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND | | | POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH | | | AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC | | | 210.8, 210.12; FBC RE E3902.16 | | | 4. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE. | | | FBC EC C405.1, R404.1 | | | 5. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 | | | 6. PROVIDE SPEC SHEET FOR MANUAL TRANSFER SWITCH | | | SHOWING THAT IT IS SERVICE ENTRANCE RATED. NEC 110.3; | | | FBC RE E3606.4 | | | 7. PROVIDE AIC RATING OF SERVICE DISCONNECT AND PANEL. | | | NEC 110.3, 110.9; FBC RE E3603.3 | | | 8. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10; FBC RE E3603.3 | | | 9. PROVIDE LOCATION OF SERVICE EQUIPMENT ON PLAN. WPB | | | FBC 107.2.1 | | | 10. PROVIDE ACCURATE RISER DIAGRAM. THE EQUIPMENT | | | GROUNDING CONDUCTOR (EGC) SHOULD NOT BE INCLUDED IN THE | | | CONDUIT FROM THE METER TO THE MANUAL TRANSFER SWITCH. | | | THE EGC FROM THE MANUAL TRANSFER SWITCH TO THE INTERIOR | | | PANEL IS NOT SIZED PROPERLY. INTERIOR PANEL STATES THAT | | | IS HAS A 125 AMP MAIN, AND BELOW THAT STATES THAT IT | | | HAS A 150 AMP MAIN. CORRECT DISCREPANCY. NEC 215.5, | | | 250.6, 250.122; WPB FBC 107.2.1; FBC RE E3704.6, | | | 3607.3.1 | | | 11. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | | SERVICE. SHOW ON PLAN. NEC 250.94; FBC RE E3609.3 | | | 12. RISER DIAGRAM SHOWS A SINGLE GROUND ROD AS A | | | SUPPLEMENTAL GROUNDING ELECTRODE. THIS SUPPLEMENTAL | | | GROUNDING ELECTRODE NEEDS TO BE AUGMENTED BY AN | | | ADDITIONAL ELECTRODE AT LEAST 6 FEET AWAY OR PROVIDE | | | EVIDENCE OF RESISTANCE TO GROUND OF 25 OHMS OR LESS. | | | NEC 250.53(A)(2); FBC RE E3608.4 | | | 13. A GFCI PROTECTED RECEPTACLE OUTLET ON A 20 AMP | | | CIRCUIT IS REQUIRED WITHIN 3 FEET OF EACH BASIN. | | | PROVIDE CORRECTION FOR MASTER BATH. NEC 210.11(C)(3), | | | 210.52(D); FBC RE E3703.4, E3901.6 | | | 14. SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING | | | REQUIREMENTS FOR OUTLETS. RECEPTACLES SHALL BE | | | INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY ALONG | | | THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN 6 FEET | | | FROM A RECEPTACLE OUTLET. THE WALL SPACING REQUIREMENTS | | | FOR KITCHEN COUNTER SPACE STATE THAT RECEPTACLE OUTLETS | | | SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL LINE | | | IS MORE THAN 24 INCHES MEASURED HORIZONTALLY FROM A | | | RECEPTACLE OUTLET IN THAT SPACE. THE PLAN PROVIDED DOES | | | NOT MEET THIS CODE IN SOME AREAS. SEE MASTER BEDROOM | | | AND AREA LEFT OF RANGE AS EXAMPLES. PROVIDE CORRECTION. | | | NEC 210.52(C)(1); FBC RE E3901 | | | 15. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | | 210.8(D); FBC RE E3902.10 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-10-30 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-10-30 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-09-17 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2018-10-30 08:12:43 | 10/30 TO DB DESK | | | | | 2018-09-18 14:56:00 | R24 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-07-30 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-07-30 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-06-25 |
Time |
13:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2018-07-30 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-07-30 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-07-30 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2018-07-30 14:35:25 | [FBC 109]IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY IS | | | REQUIRED. THE PLANS ARE TO BE STAMPED AND THE RECEIPT | | | SHOWING THAT FEES DUE, IF APPLICABLE, PROVIDED. | | | AFTER ALL OTHER REVIEWS HAVE PASSED, CHECK OUT ONE SET | | | OF PLANS TO TAKE TO THE COUNTY. | | | 561-233-5025 FOR MORE INFORMATION | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2018-10-11 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-10-11 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2018-10-11 14:40:15 | MECHANCIAL PLAN REVIEW FAIL | | | | | | | | | 1 - HEAT LOAD CALCULATION REQUIRED, 2017 FLORIDA | | | BUILDING CODE - RESIDENTIAL SEC. M1401.3EQUIPMENT AND | | | APPLIANCE SIZING. | | | | | | 2 - ENERGY CALCULATION REQUIRED, 2017 FLORIDA BUILDING | | | CODE - ENERGY CONSERVATION SEC. R405.4.2 COMPLIANCE | | | REPORT. | | | | | | | | | CHRIS MONTELLO | | | 561-805-6733 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-07-25 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-07-25 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-07-25 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2018-07-25 14:58:49 | MECHANCIAL PLAN REVIEW FAIL | | | | | | | | | 1 - NO MECHANICAL PLANS, 2017 FLORIDA BUILDING CODE - | | | BUILDING SEC. 107.2.1INFORMATION ON CONSTRUCTION | | | DOCUMENTS. | | | | | | 2 - HEAT LOAD CALCULATION REQUIRED, 2017 FLORIDA | | | BUILDING CODE - RESIDENTIAL SEC. M1401.3EQUIPMENT AND | | | APPLIANCE SIZING. | | | | | | 3 - ENERGY CALCULATION REQUIRED, 2017 FLORIDA BUILDING | | | CODE - ENERGY CONSERVATION SEC. R405.4.2 COMPLIANCE | | | REPORT. | | | | | | | | | CHRIS MONTELLO | | | 561-805-6733 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-10-09 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2018-10-09 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-10-09 |
Time |
09:17 |
Sent To |
|
|
| Notes |
| 2018-10-09 09:33:21 | PLUMBING COMMENTS: APPROVED | | | CODE COMPLIANT ISO PROVIDED | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-07-30 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2018-07-30 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2018-07-30 |
Time |
14:23 |
Sent To |
|
|
| Notes |
| 2018-07-30 14:25:40 | 07/30/2018 1ST PLUMBING REVIEW**DENIED** | | | | | | 1) PROVIDE A CODE COMPLIANT ISOMETRIC DRAWING. BOTH | | | BATHROOM HAVE 2 WET VENTED FIXTURES BEYOND THE VENT. | | | ONLY 1 WET VENTED FIXTURE IS PERMITTED UPSTREAM FROM | | | THE VENT. FBC R P3108.2.1 | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2018-10-30 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-10-30 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-10-30 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2018-10-30 15:01:34 | ROOFER TO PROVIDE PRODUCT APPROVALS WITH SUB-PERMIT. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-07-30 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-07-30 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-07-30 |
Time |
14:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2018-10-04 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-10-04 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-10-04 |
Time |
11:03 |
Sent To |
PC |
|
| Notes |
| 2018-10-04 11:07:34 | ZONING REVIEW FAILED, DUE TO THE FOLLOWING: | | | | | | 1) PLEASE SUBMIT A SEPARATE LANDSCAPE AND IRRIGATION | | | PERMIT. SHOWING THE FOLLOWING: | | | RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM | | | BEACH | | | SECTION 94-442(C)(2)A. SINGLE FAMILY DWELLING UNITS | | | O GROSS LOT SQUARE FOOTAGE MINUS | | | O BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS | | | O OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA) | | | O ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE | | | OR PORTION THEREOF | | | O ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE | | | OR PORTION THEREOF | | | 2) SHOW SETBACK DIMENSION ON WEST SIDE OF PROPERTY. | | | REQUIRES A MINIMUM OF 4'. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ | | | ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: 561-822-1442 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-07-10 |
|
|
Cont ID |
|
| Sent By |
MC |
Date |
2018-07-10 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-07-10 |
Time |
11:03 |
Sent To |
PC |
|
| Notes |
| 2018-07-10 11:41:49 | ZONING REVIEW FAILED, DUE TO THE FOLLOWING: | | | | | | 1) PURSUANT TO 94-71, TABLE III-1 A SINGLE-FAMILY | | | DWELLING IS PERMITTED PER LOT IN A SF 11 ZONING | | | DISTRICT. A MINOR SUBDIVISION APPROVAL WILL BE REQUIRED | | | IN ORDER TO BUILD A SINGLE-FAMILY HOME AT THIS | | | LOCATION. PROPERTY DEVELOPMENT REGULATIONS HAVE BEEN | | | ENCLOSED FOR YOUR REVIEW. | | | 2) SEPERATE PERMITS ARE REQUIRED FOR: A/C EQUIMENT, | | | FENCES AND LANDSCAPING. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ | | | ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: 561-822-1442 | | | E-MAIL: [email protected] |
|
|
|